Analog Devices Inc./Maxim Integrated MAX6380UR37
- Part No.:
- MAX6380UR37
- Manufacturer:
- Analog Devices Inc./Maxim Integrated
- Category:
- Supervisors
- Package:
- TO-236-3, SC-59, SOT-23-3
- Datasheet:
-
MAX6380UR37.pdf
- Description:
- IC SUPERVISOR UL LO PWR VOLT DET
- Quantity:
- Payment:

- Shipping:

Inventory:5,160
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MAX6380UR37 from Maxim Integrated is an ultra-low-power, open-drain, active-low voltage detector designed for precision power-supply monitoring in battery-powered systems. It features a factory-trimmed 3.700V threshold (±2.5% over temperature), 500nA supply current at +25°C, and guaranteed operation down to VCC = 1V. It asserts OUT low when VCC falls below VTH and is used in portable equipment reset supervision and load-switch control.
For engineers reviewing the MAX6380UR37 datasheet, MAX6380UR37 pinout, MAX6380UR37 application, or MAX6380UR37 equivalent, key selection criteria include its 3.70V trip point, SOT23-3 open-drain output configuration, ±2.5% threshold accuracy across -40°C to +85°C, immunity to sub-100µs VCC transients, and compatibility with 1.2V–5.5V supply rails.
Technical Context
The MAX6380UR37 implements a precision bandgap reference and comparator with internally trimmed resistors to set its 3.700V detection threshold. Its open-drain output requires an external pull-up and sinks ≥100µA when asserted, supporting interface with diverse logic families up to 5.5V.
It ignores fast negative-going VCC transients - maximum allowable glitch duration is ≤120µs at 100mV overdrive (VTH − VCC = 100mV) - and maintains correct output state down to 1V supply, enabling reliable brownout detection in deep-sleep microcontroller systems.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Reset Threshold Voltage | 3.700V nominal, ±2.5% over -40°C to +85°C - ensures accurate 3.7V brownout detection across industrial temperature range |
| Supply Current | 500nA at +25°C - enables multi-year battery life in coin-cell–powered IoT sensors and wearables |
| Output Type | Active-low open-drain - allows wired-OR reset buses and level-shifting via external pull-up to any rail ≤5.5V |
| VCC Operating Range | 1.2V to 5.5V - supports direct monitoring of Li+ cells, 3.3V/5V supplies, and low-voltage MCUs |
| Propagation Delay | 9.5µs typical (falling edge) - provides fast response to supply collapse without false triggering on noise |
| Threshold Hysteresis | 100mV - prevents output oscillation during slow VCC recovery near trip point |
| Output Leakage (OFF) | 0.8µA max at VCC = 5.5V - minimizes standby current in high-impedance reset networks |
Pinout & Package
MAX6380UR37 is housed in a 3-pin SOT23-3 package (JEDEC MO-178AA), footprint-compatible with SC70-3 but with higher power dissipation rating (320mW at +70°C).
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 | GND | Ground reference for internal bandgap and comparator - must be low-impedance connection to system ground plane |
| 2 | OUT | Open-drain active-low output - sinks current when VCC < 3.700V; requires external pull-up resistor for logic-level assertion |
| 3 | VCC | Supply input - monitors this rail directly; operates from 1.2V to 5.5V with full specification compliance |
Key Features
| Feature | Design Value |
|---|---|
| Ultra-low 500nA supply current | Enables >10-year battery life in always-on monitoring applications using CR2032 cells |
| Factory-trimmed 3.700V threshold | Eliminates external resistor divider and calibration, reducing BOM count and layout area |
| ±2.5% threshold accuracy over temperature | Guarantees reliable reset assertion across full -40°C to +85°C industrial range without derating |
| Open-drain output with 5.5V-tolerant OFF-state | Permits flexible reset bus design with mixed-voltage systems (e.g., 1.8V MCU + 3.3V peripheral) |
| Transient immunity (≤120µs glitches rejected) | Prevents spurious resets during switching regulator noise or hot-plug events |
Applications
| Portable Medical Sensor | Industrial PLC I/O Module |
|---|---|
Use Scenario: A handheld glucose meter uses a CR2032 coin cell and enters deep sleep between measurements. IC Role / Device Role / Timing Role: MAX6380UR37 monitors the 3.0V regulated rail and asserts reset to the MCU if voltage drops below 3.7V due to battery aging or cold-temperature derating. Use Value: Prevents corrupted EEPROM writes and sensor initialization failures by ensuring MCU only wakes under valid supply conditions. |
Use Scenario: An isolated digital input module powers its microcontroller and optocouplers from a 5V DC/DC converter. IC Role / Device Role / Timing Role: MAX6380UR37 supervises the 5V rail and triggers a hardware reset if input undervoltage occurs during field wiring faults or supply sag. Use Value: Guarantees deterministic startup and eliminates lockup states caused by marginal 5V operation in harsh EMI environments. |
| Smart Home Smoke Detector | Asset Tracking Beacon |
Use Scenario: A battery-powered smoke detector uses a low-quiescent LDO to generate 3.3V for its MCU and analog front-end. IC Role / Device Role / Timing Role: MAX6380UR37 watches the LDO output and forces a controlled shutdown sequence when battery voltage decays below 3.7V. Use Value: Ensures end-of-life alert transmission completes before power loss, meeting UL 217 compliance requirements. |
Use Scenario: A GPS-enabled logistics tag sleeps for 12 hours between transmissions, powered by a 3.6V Li-SOCl₂ cell. IC Role / Device Role / Timing Role: MAX6380UR37 detects early battery depletion (3.7V threshold) and signals the MCU to enter permanent low-power mode. Use Value: Avoids unexpected field failure by proactively retiring units before capacity falls below critical operational margin. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar voltage detector applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| TLV803EB37DBZR | 3.7V open-drain detector, 350nA ICC, SOT23-3, but ±3% threshold accuracy over temperature | Lacks guaranteed 1V operation; minimum VCC = 1.5V - unsuitable for ultra-low-VCC brownout detection | Choose when lower supply current is prioritized and 1.5V+ operation suffices |
| APX803S-37SA-7 | 3.7V open-drain detector, 600nA ICC, SOT23-3, ±2% accuracy, but no transient immunity spec provided | No published maximum transient rejection time - risk of false reset in noisy switch-mode environments | Choose when tighter threshold tolerance is required and system has clean power rails |
Compared with TLV803EB37DBZR and APX803S-37SA-7, the MAX6380UR37 uniquely combines guaranteed 1V operation, documented 120µs transient immunity at 100mV overdrive, and ±2.5% accuracy - making it the preferred choice for robust brownout detection in battery-critical and EMI-prone designs.
Availability
MAX6380UR37 is available at Aetrix Electronics and suitable for portable medical sensors, industrial I/O modules, smart home safety devices, and asset tracking beacons requiring stable component supply and long-term manufacturability.
Supply support for MAX6380UR37 includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Maxim Integrated (now part of Analog Devices) is a U.S.-based semiconductor company specializing in high-performance analog, mixed-signal, and power-management ICs for industrial, automotive, and communications markets.
The MAX6375–MAX6380 family was designed specifically for ultra-low-power voltage monitoring in space-constrained, battery-operated systems - delivering precision reset functionality without external components or trimming.
FAQ
What is the exact reset threshold voltage of the MAX6380UR37?
The MAX6380UR37 has a factory-trimmed nominal reset threshold of 3.700V, with guaranteed accuracy of ±2.5% over the full operating temperature range of -40°C to +85°C. At +25°C, the typical threshold is 3.700V, and the min/max limits are 3.607V and 3.792V respectively - confirmed in Table 1 of the official datasheet.
Does the MAX6380UR37 require an external pull-up resistor on its OUT pin?
Yes, the MAX6380UR37 features an open-drain active-low output, so an external pull-up resistor is mandatory for proper logic-level assertion. The resistor connects between OUT and any supply rail up to 5.5V. Typical values range from 10kΩ to 100kΩ, selected to ensure VOL ≤0.4V at ISINK = 100µA while minimizing standby current.
Can the MAX6380UR37 operate reliably below 1.2V supply voltage?
No - the absolute minimum specified VCC for functional operation is 1.2V. Although the device guarantees correct output logic state down to 1V, electrical characteristics including propagation delay, threshold accuracy, and output drive are only guaranteed within the 1.2V to 5.5V operating range per the datasheet's Electrical Characteristics table.
What package type is used for the MAX6380UR37, and is it RoHS-compliant?
The MAX6380UR37 is supplied in a 3-pin SOT23-3 package (JEDEC MO-178AA). It is available in both leaded and lead-free versions; the standard -T suffix denotes leaded packaging, while replacing -T with +T specifies RoHS-compliant lead-free construction - explicitly confirmed in the Ordering Information section.
How does the MAX6380UR37 handle short voltage transients on the VCC line?
The MAX6380UR37 rejects fast negative-going VCC transients up to 120µs in duration when the overdrive (VTH − VCC) is 100mV, as shown in Figure MAX6375-04. This built-in immunity prevents false resets during switching regulator noise, hot-plug events, or ESD-induced supply dips - a key differentiator versus basic comparators without transient filtering.
MAX6380UR37 Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Analog Devices Inc./Maxim Integrated
- Series:
- -
- Package/Case:
- TO-236-3, SC-59, SOT-23-3
- Packaging:
- Bulk
- Product Status:
- Active
- Programmable:
- Not Verified
- Type:
- Voltage Detector
- Number of Voltages Monitored:
- 1
- Voltage - Threshold:
- 3.7V
- Output:
- Open Drain or Open Collector
- Reset:
- Active Low
- Reset Timeout:
- -
- Operating Temperature:
- -40°C ~ 85°C (TA)
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- SOT-23-3
MAX6380UR37 FAQ
1.How can I place an order for MAX6380UR37 through Aetrix?
Please submit a Request for Quotation (RFQ) for MAX6380UR37 on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MAX6380UR37 reliable?
The price and inventory of MAX6380UR37 are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MAX6380UR37 is usually 5 days.
3.What payment methods are accepted for MAX6380UR37?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MAX6380UR37 transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MAX6380UR37?
MAX6380UR37 orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MAX6380UR37 order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MAX6380UR37?
For technical support, including MAX6380UR37 datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MAX6380UR37 requirements.
6.How does Aetrix verify that MAX6380UR37 is sourced from the original manufacturer or authorized distributors?
All MAX6380UR37 products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MAX6380UR37 meets industry standards.
7.What is the process for return or replacement of MAX6380UR37?
All MAX6380UR37 units undergo pre-shipment inspection (PSI). If there is an issue with MAX6380UR37, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MAX6380UR37 part is unused and in its original packaging.
Return procedure for MAX6380UR37:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MAX6380UR37 Tags

-
MIC826SYMT-TR
Microchip Technology

-
APX803S-31SA-7
Diodes Incorporated

-
APX803L20-29SA-7
Diodes Incorporated
-
TPS3828-33DBVR
Texas Instruments

-
V6340RSP3B+
EM Microelectronic

-
EM6325CXSP5B-2.9+
EM Microelectronic

-
MCP120T-300I/TT
Microchip Technology

-
MCP130T-315I/TT
Microchip Technology

-
MCP120T-475I/TT
Microchip Technology

-
MCP111T-300E/TT
Microchip Technology

-
MCP120T-315I/TT
Microchip Technology

-
MCP809T-315I/TT
Microchip Technology
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…