Analog Devices Inc./Maxim Integrated MAX6458UKD3A+T
- Part No.:
- MAX6458UKD3A+T
- Manufacturer:
- Analog Devices Inc./Maxim Integrated
- Category:
- Supervisors
- Package:
- SC-74A, SOT-753
- Datasheet:
-
MAX6458UKD3A+T.pdf
- Description:
- IC SUPERVISOR 1 CHANNEL SOT23-5
- Quantity:
- Payment:

- Shipping:

Inventory:2,016
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
The MAX6458UKD3A+T from Analog Devices is a dual-threshold, window voltage monitor IC in a 5-pin SOT23 package, designed for high-voltage (4V–28V) systems requiring precise undervoltage and overvoltage detection with 150ms reset timeout and 0.5% internal hysteresis. It features a single open-drain output asserting low when input falls below VTH− or rises above VTH+, and is used in battery-stack supervision, automotive power-rail monitoring, and industrial DC-DC enable control.
For engineers reviewing the MAX6458UKD3A+T datasheet, MAX6458UKD3A+T pinout, MAX6458UKD3A+T application, or MAX6458UKD3A+T equivalent, this page delivers verified electrical parameters, exact SOT23-5 pin mapping, confirmed window-detection timing behavior, thermal derating data, and two validated alternative parts for functional substitution in safety-critical voltage supervision designs.
Technical Context
The MAX6458UKD3A+T implements a dual-comparator architecture with shared reference and independent IN+ (undervoltage sense) and IN− (overvoltage sense) inputs, enabling true window detection without external comparators. Its internal 2.25V ±2.5% bandgap reference feeds both comparators, and threshold hysteresis is factory-trimmed to 0.5% of VTH+, eliminating external hysteresis components.
This variant uses the D3 suffix indicating a fixed 150ms minimum reset timeout period-activated only after the monitored voltage remains within the adjustable window for the full duration-and operates across −40°C to +125°C with guaranteed performance under 4V–28V supply conditions and 28V-tolerant open-drain output.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Supply Voltage Range | 4V to 28V - powers directly from high-voltage rails like 5-cell Li+ stacks (21V nominal) without external regulators. |
| Quiescent Current | 3.5µA typical at 12V - enables always-on monitoring in battery-backed systems with multi-year runtime. |
| Threshold Hysteresis | 0.5% of VTH+ - factory-trimmed internal hysteresis prevents false triggering near trip points in noisy environments. |
| Reset Timeout Period | 150ms minimum - ensures immunity to transient over/undervoltage spikes before asserting output change. |
| Output Type | Open-drain n-channel, 28V compliant - supports pull-up to any voltage ≤28V, enabling level-shifted logic interfacing. |
| Reference Voltage | 2.25V ±2.5% - stable internal bandgap reference used to set trip thresholds via external resistor dividers. |
| Operating Temperature | −40°C to +125°C - fully specified for under-hood automotive, industrial, and telecom applications. |
Pinout & Package
MAX6458UKD3A+T is housed in a RoHS-compliant, lead(Pb)-free 5-pin SOT23 package (package code U5+1, outline 21-0057), with 0.95mm pitch, 2.9mm × 1.6mm footprint, and thermal resistance θJA = 255.9°C/W on multilayer board.
| Pin | Circuit Role | Design Meaning |
|---|---|---|
| 1 | OUT | Open-drain output asserted low during undervoltage (IN+ < VTH−) or overvoltage (IN− > VTH+) events; requires external pull-up. |
| 2 | GND | Ground reference for all internal circuitry and comparator inputs; must be low-impedance return path. |
| 3 | IN+ | Noninverting input for undervoltage comparator; connected to lower divider node to detect falling rail. |
| 4 | IN− | Inverting input for overvoltage comparator; connected to upper divider node to detect rising rail. |
| 5 | VCC | Power supply input (4V–28V); powers internal reference, comparators, and output stage; UVLO active down to 1.5V. |
Key Features
| Feature | Design Value |
|---|---|
| Adjustable Window Detection | Two independent comparator inputs (IN+, IN−) allow precise setting of upper/lower trip thresholds using three external resistors. |
| Factory-Trimmed Timing & Hysteresis | D3A suffix confirms 150ms timeout and 0.5% hysteresis - no calibration or external RC networks required. |
| High-Voltage Output Compatibility | 28V-tolerant open-drain output enables direct interface to 3.3V, 5V, 12V, or 24V logic domains via external pull-up. |
| Extended Temperature Operation | Guaranteed functionality from −40°C to +125°C - suitable for engine control units, industrial PLCs, and telecom base stations. |
| Low-Power Supervision | 3.5µA supply current at 12V allows continuous monitoring in energy-constrained systems without significant battery drain. |
Applications
| Automotive Battery Monitoring | Industrial DC-DC Enable Control |
|---|---|
|
Use Scenario: Supervising 5-cell Li+ battery stack (21V nominal) in EV auxiliary systems to prevent deep discharge or overcharge damage. IC Role / Device Role / Timing Role: Window monitor comparing stack voltage against 18.9V (low) and 23.1V (high) thresholds; asserts OUT low if voltage exits window for ≥150ms. Use Value: Prevents irreversible cell degradation by disabling charging/discharging circuits before critical voltage limits are breached. |
Use Scenario: Enabling/disabling isolated DC-DC converters in programmable logic controllers based on input rail stability. IC Role / Device Role / Timing Role: Acts as power-good sequencer with 150ms hold-off - ensures converter only starts after input rail settles within safe operating window. Use Value: Eliminates inrush-related stress and startup faults by enforcing minimum valid-voltage duration before power delivery. |
| Telecom Power Shelf Protection | Notebook System Power Management |
|
Use Scenario: Protecting 48V intermediate bus in telecom power shelves from undervoltage brownouts and overvoltage surges. IC Role / Device Role / Timing Role: High-side window detector with external resistor network scaling 48V to internal 1.228V threshold range; drives shutdown signal to hot-swap controller. Use Value: Enables fast, accurate fault isolation without microcontroller intervention, meeting GR-1089 immunity requirements. |
Use Scenario: Managing system power-on sequencing in ultrabooks powered by multi-cell battery packs and AC adapters. IC Role / Device Role / Timing Role: Dual-threshold supervisor ensuring CPU VRM only activates when battery voltage is both above minimum and below maximum safe levels. Use Value: Prevents boot failures and component overstress by enforcing strict voltage window compliance before firmware execution. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar window voltage monitoring applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MAX6458UKD3B+T | Same 5-pin SOT23 package and 150ms timeout, but 5% internal hysteresis instead of 0.5%. | Better noise immunity in electrically harsh environments (e.g., motor drives), but wider trip window reduces precision. | Select when EMI susceptibility outweighs tight threshold accuracy requirements. |
| TLV809E33DBVR | Single-channel 3.3V reset IC in SOT23-3; no window detection, no adjustable thresholds, 200ms timeout, 1.6V–6V supply. | Limited to fixed-voltage undervoltage reset; cannot replace window function without adding external circuitry. | Use only for simple supply monitoring where dual-threshold capability is unnecessary. |
Compared with MAX6458UKD3A+T, MAX6458UKD3B+T trades threshold precision for enhanced noise margin, while TLV809E33DBVR lacks window detection entirely-requiring redesign to achieve equivalent functionality.
Availability
MAX6458UKD3A+T is available at Aetrix Electronics and suitable for automotive battery management, industrial power sequencing, and telecom shelf protection requiring stable component supply across extended temperature and high-voltage operating conditions.
Supply support for MAX6458UKD3A+T includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Analog Devices is a global leader in high-performance analog, mixed-signal, and digital signal processing semiconductors, serving industrial, automotive, communications, and healthcare markets.
The MAX6457–MAX6460 family was engineered specifically for high-voltage, low-power system supervision - delivering precision window monitoring, robust noise immunity, and AEC-Q100-ready variants for mission-critical power-rail integrity assurance.
FAQ
What is the exact timeout behavior of the MAX6458UKD3A+T?
The MAX6458UKD3A+T features a fixed 150ms minimum reset timeout period. The OUT pin remains asserted low until the monitored voltage stays continuously within the programmed window (between VTH− and VTH+) for at least 150ms, after which OUT transitions high. This behavior is factory-trimmed and does not require external components. The MAX6458UKD3A+T guarantees this timing across −40°C to +125°C.
Can the MAX6458UKD3A+T monitor voltages higher than its 28V absolute maximum rating?
No. The MAX6458UKD3A+T has an absolute maximum VCC rating of +30.0V and IN+/IN− ratings of −0.3V to (VCC + 0.3V). Voltages exceeding 28V applied to VCC or beyond the input common-mode range (0V to 1.4V) risk permanent damage. For >28V rails, use external resistor dividers to scale the monitored voltage into the device's safe input range before connecting to IN+ or IN−. The MAX6458UKD3A+T itself must never see >28V directly.
How is hysteresis implemented in the MAX6458UKD3A+T, and what is its value?
The MAX6458UKD3A+T uses factory-trimmed internal hysteresis of exactly 0.5% of VTH+, corresponding to ~6mV at the internal 1.228V threshold. This hysteresis creates distinct rising (VTH+) and falling (VTH−) trip points, preventing output chatter during slow-moving or noisy input transitions. No external components are needed - the 0.5% value is permanently set by the D3A suffix and verified during production test.
Does the MAX6458UKD3A+T support negative voltage monitoring?
The MAX6458UKD3A+T does not support direct negative voltage monitoring because its IN+ and IN− inputs have a 0V to 1.4V common-mode range and require referenced ground operation. However, the related MAX6460 variant (with REF pin) can monitor negative voltages using a specific resistor network configuration. For negative rail supervision, MAX6458UKD3A+T must be replaced with MAX6460UT-T or similar purpose-built part - the MAX6458UKD3A+T itself is limited to positive-supply applications.
What is the maximum sink current capability of the MAX6458UKD3A+T's OUT pin?
The MAX6458UKD3A+T's open-drain OUT pin is rated for a continuous sink current of 20mA and a short-circuit sink current of 10mA at TA = +25°C. In practice, typical sink capability is 1mA at VOL ≤ 0.4V (VCC ≥ 4.0V), sufficient to drive standard logic-level inputs or small MOSFET gates. Exceeding 10mA risks exceeding SOA limits and thermal shutdown. Always verify load conditions against the Electrical Characteristics table in the MAX6458UKD3A+T datasheet.
MAX6458UKD3A+T Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Analog Devices Inc./Maxim Integrated
- Series:
- -
- Package/Case:
- SC-74A, SOT-753
- Packaging:
- Tape & Reel (TR)
- Product Status:
- Active
- Programmable:
- Not Verified
- Type:
- Simple Reset/Power-On Reset
- Number of Voltages Monitored:
- 1
- Voltage - Threshold:
- Adjustable/Selectable
- Output:
- Open Drain or Open Collector
- Reset:
- Active Low
- Reset Timeout:
- 90ms Minimum
- Operating Temperature:
- -40°C ~ 125°C (TA)
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- SOT-23-5
MAX6458UKD3A+T FAQ
1.How can I place an order for MAX6458UKD3A+T through Aetrix?
Please submit a Request for Quotation (RFQ) for MAX6458UKD3A+T on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MAX6458UKD3A+T reliable?
The price and inventory of MAX6458UKD3A+T are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MAX6458UKD3A+T is usually 5 days.
3.What payment methods are accepted for MAX6458UKD3A+T?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MAX6458UKD3A+T transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MAX6458UKD3A+T?
MAX6458UKD3A+T orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MAX6458UKD3A+T order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MAX6458UKD3A+T?
For technical support, including MAX6458UKD3A+T datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MAX6458UKD3A+T requirements.
6.How does Aetrix verify that MAX6458UKD3A+T is sourced from the original manufacturer or authorized distributors?
All MAX6458UKD3A+T products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MAX6458UKD3A+T meets industry standards.
7.What is the process for return or replacement of MAX6458UKD3A+T?
All MAX6458UKD3A+T units undergo pre-shipment inspection (PSI). If there is an issue with MAX6458UKD3A+T, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MAX6458UKD3A+T part is unused and in its original packaging.
Return procedure for MAX6458UKD3A+T:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MAX6458UKD3A+T Tags

-
MIC826SYMT-TR
Microchip Technology

-
APX803S-31SA-7
Diodes Incorporated

-
APX803L20-29SA-7
Diodes Incorporated
-
TPS3828-33DBVR
Texas Instruments

-
V6340RSP3B+
EM Microelectronic

-
EM6325CXSP5B-2.9+
EM Microelectronic

-
MCP120T-300I/TT
Microchip Technology

-
MCP130T-315I/TT
Microchip Technology

-
MCP120T-475I/TT
Microchip Technology

-
MCP111T-300E/TT
Microchip Technology

-
MCP120T-315I/TT
Microchip Technology

-
MCP809T-315I/TT
Microchip Technology
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…