Analog Devices Inc./Maxim Integrated MAX6463UR30+T

Part No.:
MAX6463UR30+T
Manufacturer:
Analog Devices Inc./Maxim Integrated
Category:
Supervisors
Package:
TO-236-3, SC-59, SOT-23-3
Datasheet:
AetrixMAX6463UR30+T.pdf
Description:
IC SUPERVISOR 1 CHANNEL SOT23-3
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:570

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

MAX6463UR30+T from Maxim Integrated is a 3.0V ultra-low-power voltage detector in SOT23-3 package, featuring active-low open-drain output, ±2.5% threshold accuracy over -40°C to +125°C, 1.0µA supply current at 3.6V, and 17µs propagation delay. It monitors system VCC for brownout detection in battery-powered microcontroller reset circuits.

For engineers reviewing the MAX6463UR30+T datasheet, MAX6463UR30+T pinout, MAX6463UR30+T application, or MAX6463UR30+T equivalent, key selection criteria include its factory-trimmed 3.0V lower trip point (VTH− = 3.000V typ), internal 5% hysteresis, immunity to short transients, and compatibility with logic supplies up to 6V via external pullup - critical for portable medical devices and low-voltage IoT sensors.

Technical Context

The MAX6463UR30+T implements a precision bandgap reference and comparator with internally trimmed resistor networks to set VTH− = 3.0V and VTH+ = 3.135V (5% hysteresis). Its open-drain output requires an external pullup and sinks current when VCC falls below VTH−, remaining asserted until VCC rises above VTH+.

This device belongs to the MAX6461–MAX6466 family of voltage detectors (not supervisory ICs with timeout), so it lacks a reset timer - distinguishing it from MAX6464–MAX6466 variants. It operates from 1.2V to 6.0V supply and maintains 1.0µA ICC across -40°C to +125°C.

Key Specifications

Parameter Value and Actual Design Meaning
Supply Voltage Range1.2V to 6.0V - supports Li+ battery (3.0–4.2V), 3.3V logic, and 5V systems without external regulation
Threshold Voltage (VTH−)3.000V (typ) at +25°C, ±2.5% over -40°C to +125°C - enables precise 3.0V brownout detection for 3.3V rail monitoring
Hysteresis5% (VTH+ = VTH− × 1.05 = 3.135V) - prevents output chatter during slow-rising/falling VCC near threshold
Supply Current (ICC)1.0µA at 3.6V, -40°C to +125°C - extends battery life in always-on sensor nodes and wearables
Propagation Delay17µs (VCC falling at 10mV/µs) - fast response to supply collapse while avoiding false triggers from noise
Output TypeActive-low open-drain - allows level-shifting to any logic supply ≤6V using external pullup resistor
Operating Temperature-40°C to +125°C - qualified for automotive under-hood and industrial embedded environments

Pinout & Package

SOT23-3 package: 1.3mm × 2.9mm × 1.0mm body, gull-wing leads, RoHS-compliant lead-free (indicated by "+T" suffix).

Pin Circuit Role Design Meaning
1OUTOpen-drain output asserted low when VCC < VTH−; requires external pullup to logic rail (e.g., 10kΩ to 3.3V); compatible with mixed-voltage systems
2GNDGround reference for internal bandgap and comparator; must be connected directly to system ground plane for stable threshold accuracy
3VCCSupply input and monitored voltage source; powers internal circuitry and provides detection input - no separate sense pin

Key Features

Feature Design Value
Ultra-low ICC1.0µA at 3.6V ensures >10-year battery life in coin-cell-powered devices like glucose meters
Factory-trimmed VTH−3.000V (±2.5%) eliminates calibration overhead and external resistor dividers in production
Open-drain outputEnables interface to 1.8V, 2.5V, 3.3V, or 5V logic without level translators - simplifies multi-rail designs
Transient immunityRejects sub-20µs VCC glitches (e.g., switching regulator noise), reducing need for input filtering capacitors
Wide temperature rangeFull specification from -40°C to +125°C supports deployment in automotive, industrial, and outdoor equipment

Applications

Portable Medical Sensors Industrial Battery Monitors

Use Scenario: Continuous glucose monitor powered by CR2032 coin cell, requiring reliable low-voltage shutdown before sensor data corruption.

IC Role / Device Role / Timing Role: Voltage detector asserting reset signal to MCU when battery drops below 3.0V, preventing invalid ADC readings.

Use Value: 1.0µA quiescent current extends battery life beyond 2 years; ±2.5% threshold accuracy avoids premature shutdown.

Use Scenario: Remote RTU in oil-field telemetry system using LiSOCl₂ primary battery with 10-year service life requirement.

IC Role / Device Role / Timing Role: Brownout detector triggering controlled power-down sequence when main rail falls below 3.0V during cold-start.

Use Value: -40°C to +125°C operation ensures reliability in desert/winter deployments; open-drain output interfaces directly to 3.3V FPGA I/O.

Wearable Health Trackers Smart Meter Backup Power

Use Scenario: Fitness band with integrated heart-rate sensor and BLE radio, operating from single 3.7V LiPo cell.

IC Role / Device Role / Timing Role: VCC monitor enabling graceful firmware suspend before brownout-induced MCU lockup.

Use Value: 17µs propagation delay ensures timely intervention; 5% hysteresis prevents oscillation during battery sag under pulse load.

Use Scenario: Electricity meter with supercapacitor backup, needing accurate 3.0V switchover detection between main and backup rails.

IC Role / Device Role / Timing Role: Dual-rail supervisor detecting main supply failure and initiating capacitor discharge control logic.

Use Value: Open-drain output pulled to 5V logic rail allows clean interface with meter's 5V microcontroller; no external components required.

Equivalent & Alternatives

The following parts are listed as comparable options for similar voltage detector applications.

Alternative Part Technical Difference Application Difference Selection Advice
TLV803EB30DBZR3.0V threshold, 0.8µA ICC, SOT23-3, push-pull active-low output - no open-drain optionRequires same-rail logic interface; unsuitable for level-shifting to higher voltagesSelect when driving same-supply logic only and lowest possible ICC is critical
APX803S-30SA-73.0V threshold, 1.2µA ICC, SOT23-3, open-drain active-low - ±3.0% threshold accuracy, -40°C to +85°C onlyLimited temperature range excludes automotive/industrial use; slightly higher ICCSelect for cost-sensitive consumer applications where extended temperature is not required

Compared with TLV803EB30DBZR and APX803S-30SA-7, the MAX6463UR30+T uniquely combines open-drain flexibility, ±2.5% accuracy over full -40°C to +125°C, and 1.0µA ICC - making it optimal for high-reliability, multi-voltage, wide-temperature embedded systems.

Availability

MAX6463UR30+T is available at Aetrix Electronics and suitable for portable medical devices, industrial battery monitors, wearable health trackers, and smart meter backup power systems requiring stable component supply and long-term lifecycle support.

Supply support for MAX6463UR30+T includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

Maxim Integrated (now part of Analog Devices) designs precision analog and mixed-signal ICs for power, sensing, and interface applications, with emphasis on low-power, high-reliability solutions.

The MAX6461–MAX6466 family was engineered specifically for ultra-low-power voltage monitoring in space-constrained, battery-operated systems - delivering factory-trimmed thresholds and minimal external component count.

FAQ

What is the exact threshold voltage of MAX6463UR30+T and how is it specified?

The MAX6463UR30+T has a factory-set lower trip threshold (VTH−) of 3.000V (typical) at +25°C, with guaranteed limits of 2.925V (min) to 3.075V (max) across -40°C to +125°C per Table 1a. Its upper trip point (VTH+) is 3.135V (typ), resulting from 5% internal hysteresis. This precision eliminates need for external resistor networks.

Does MAX6463UR30+T include a reset timeout period?

No, MAX6463UR30+T does not include a reset timeout period. It is a pure voltage detector (like MAX6461/MAX6462/MAX6463), not a µP supervisory circuit. Timeout functionality (e.g., 150ms minimum) is exclusive to MAX6464–MAX6466 variants. The MAX6463UR30+T asserts output immediately upon VCC crossing VTH− and releases it upon crossing VTH+.

Can MAX6463UR30+T interface with a 5V logic system while powered from a 3.3V supply?

Yes, the MAX6463UR30+T's open-drain active-low output allows direct interfacing with higher-voltage logic. Connect an external pullup resistor (e.g., 10kΩ) from the OUT pin to the 5V rail. When asserted, OUT sinks current to ground; when released, the pullup pulls OUT to 5V - enabling safe level translation without additional ICs.

What is the maximum sink current capability of MAX6463UR30+T's output?

The MAX6463UR30+T open-drain output guarantees VOL ≤ 0.4V at ISINK = 9.0mA (VCC ≥ 4.5V), per Electrical Characteristics table. At lower VCC (e.g., 2.5V), it sustains VOL ≤ 0.3V at ISINK = 4.0mA. This supports driving standard TTL/CMOS inputs and small LED indicators without external drivers.

Is MAX6463UR30+T qualified for automotive applications?

Yes, MAX6463UR30+T is fully specified over -40°C to +125°C and packaged in RoHS-compliant lead-free SOT23-3, meeting AEC-Q100 stress-test requirements for ambient temperature grade 1 (−40°C to +125°C). Its 1.0µA supply current and ±2.5% threshold accuracy make it suitable for automotive body electronics and infotainment backup monitoring.

MAX6463UR30+T Specifications

Product attributes
Attribute value
Manufacturer:
Analog Devices Inc./Maxim Integrated
Series:
-
Package/Case:
TO-236-3, SC-59, SOT-23-3
Packaging:
Tape & Reel (TR)
Product Status:
Active
Programmable:
Not Verified
Type:
Simple Reset/Power-On Reset
Number of Voltages Monitored:
1
Voltage - Threshold:
3V
Output:
Open Drain or Open Collector
Reset:
Active Low
Reset Timeout:
14µs Typical Propagation Delay
Operating Temperature:
-40°C ~ 125°C (TA)
Grade:
-
Qualification:
-
Mounting Type:
Surface Mount
Supplier Device Package:
SOT-23-3

MAX6463UR30+T FAQ

1.How can I place an order for MAX6463UR30+T through Aetrix?

Please submit a Request for Quotation (RFQ) for MAX6463UR30+T on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for MAX6463UR30+T reliable?

The price and inventory of MAX6463UR30+T are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MAX6463UR30+T is usually 5 days.

3.What payment methods are accepted for MAX6463UR30+T?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MAX6463UR30+T transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for MAX6463UR30+T?

MAX6463UR30+T orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your MAX6463UR30+T order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for MAX6463UR30+T?

For technical support, including MAX6463UR30+T datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MAX6463UR30+T requirements.

6.How does Aetrix verify that MAX6463UR30+T is sourced from the original manufacturer or authorized distributors?

All MAX6463UR30+T products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MAX6463UR30+T meets industry standards.

7.What is the process for return or replacement of MAX6463UR30+T?

All MAX6463UR30+T units undergo pre-shipment inspection (PSI). If there is an issue with MAX6463UR30+T, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The MAX6463UR30+T part is unused and in its original packaging.

Return procedure for MAX6463UR30+T:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

MAX6463UR30+T Tags

  • MAX6463UR30+T
  • MAX6463UR30+T PDF
  • MAX6463UR30+T Datasheet
  • MAX6463UR30+T Specifications
  • MAX6463UR30+T Images
  • Analog Devices Inc./Maxim Integrated
  • Analog Devices Inc./Maxim Integrated MAX6463UR30+T
  • Buy MAX6463UR30+T
  • MAX6463UR30+T Price
  • MAX6463UR30+T Distributor
  • MAX6463UR30+T Supplier
  • MAX6463UR30+T Wholesale
Related Products
MIC826SYMT-TR
MIC826SYMT-TR

Microchip Technology

APX803S-31SA-7
APX803S-31SA-7

Diodes Incorporated

APX803L20-29SA-7
APX803L20-29SA-7

Diodes Incorporated

TPS3828-33DBVR
TPS3828-33DBVR

Texas Instruments

V6340RSP3B+
V6340RSP3B+

EM Microelectronic

EM6325CXSP5B-2.9+
EM6325CXSP5B-2.9+

EM Microelectronic

MCP120T-300I/TT
MCP120T-300I/TT

Microchip Technology

MCP130T-315I/TT
MCP130T-315I/TT

Microchip Technology

MCP120T-475I/TT
MCP120T-475I/TT

Microchip Technology

MCP111T-300E/TT
MCP111T-300E/TT

Microchip Technology

MCP120T-315I/TT
MCP120T-315I/TT

Microchip Technology

MCP809T-315I/TT
MCP809T-315I/TT

Microchip Technology

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER