Analog Devices Inc./Maxim Integrated MAX6855UK30D6+T
- Part No.:
- MAX6855UK30D6+T
- Manufacturer:
- Analog Devices Inc./Maxim Integrated
- Category:
- Supervisors
- Package:
- SC-74A, SOT-753
- Datasheet:
-
MAX6855UK30D6+T.pdf
- Description:
- IC SUPERVISOR 1 CHANNEL SOT23-5
- Quantity:
- Payment:

- Shipping:

Inventory:2,254
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
The MAX6855UK30D6+T from Maxim Integrated is a nanopower microprocessor supervisory circuit in a 5-pin SOT23 package, featuring ultra-low 170nA typical supply current, factory-trimmed 3.000V reset threshold (suffix "30"), and 600ms–1200ms minimum reset timeout (suffix "D6"). It provides active-low push-pull reset output, manual reset input (MR), and operates across –40°C to +85°C for battery-powered medical and portable electronics.
For engineers reviewing the MAX6855UK30D6+T datasheet, MAX6855UK30D6+T pinout, MAX6855UK30D6+T application, or MAX6855UK30D6+T equivalent, key selection criteria include guaranteed reset validity down to VCC = +1.1V, immunity to short VCC transients (<40µs at 100mV overdrive), no external components required, and compatibility with CMOS-level MR signaling.
Technical Context
This device integrates voltage monitoring, manual reset assertion, and reset timing control - but excludes watchdog timer functionality (absent in MAX6855 family members). Its internal 10kΩ MR pullup enables direct switch-to-GND implementation without external biasing.
The reset output remains asserted for ≥600ms after VCC rises above 3.000V and MR deasserts, with tRD < 40µs during VCC fall and tMRD = 250ns from MR low-to-reset assertion. Reset threshold hysteresis is ±0.5% of VTH, ensuring stable release under noisy supply conditions.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Reset Threshold | 3.000V ±2.5% (factory-trimmed; ensures reliable brownout detection at nominal 3.0V rail) |
| Reset Timeout Period | 600ms–1200ms min (D6 option; guarantees µP initialization completes before release) |
| Supply Current | 170nA typ at +25°C (enables >10-year battery life in glucose monitors and pagers) |
| VCC Operating Range | 1.2V to 5.5V (supports single-cell Li-ion, 2xAA, and 3.3V/5V logic rails) |
| Reset Validity Limit | Guaranteed to VCC = +1.1V (ensures deterministic reset state during deep brownout) |
| MR Input Logic | Active-low, internally pulled up to VCC via 10kΩ (allows direct momentary switch interface) |
| Output Type | Push-pull active-low RESET (drives directly into µP reset pin; no external pullup needed) |
Pinout & Package
Package: 5-pin SOT23-5, lead-free, surface-mount. Compact footprint (2.9mm × 1.6mm × 1.1mm) suitable for space-constrained portable designs.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 | RESET | Active-low push-pull reset output; sinks current when asserted, drives high-impedance when deasserted |
| 2 | GND | Ground reference for all internal circuitry and reset timing generator |
| 3 | MR | Active-low manual reset input; internally pulled up to VCC; 250ns delay to RESET assertion |
| 4 | GND | Second ground terminal; must be connected to same potential as Pin 2 for noise immunity |
| 5 | VCC | Supply voltage input and monitored rail; requires 0.1µF bypass capacitor to GND per datasheet |
Key Features
| Feature | Design Value |
|---|---|
| Ultra-low ICC | 170nA typical supply current enables multi-year operation on coin cells in patient monitors |
| No external components | Eliminates BOM cost and board area for RC timing networks or pullup resistors |
| VCC transient immunity | Immune to ≤40µs supply glitches at 100mV overdrive - prevents spurious resets in noisy environments |
| Guaranteed reset at low VCC | Valid RESET signal asserted down to VCC = +1.1V - critical for orderly shutdown in brownout |
| CMOS-compatible MR | Internal 10kΩ pullup allows direct connection to open-drain logic or mechanical switches |
Applications
| Portable Medical Devices | Battery-Powered Test Equipment |
|---|---|
|
Use Scenario: Glucose meter operating from CR2032 coin cell with intermittent sensor activation. IC Role / Device Role / Timing Role: Monitors 3.0V rail; asserts reset during power-up and brownout; holds µP in reset until stable voltage and software initialization complete. Use Value: Prevents corrupted EEPROM writes and false glucose readings caused by premature firmware execution. |
Use Scenario: Handheld multimeter with auto-power-down and button-initiated wake-up. IC Role / Device Role / Timing Role: Provides clean power-on reset and manual reset via front-panel button; ensures ADC and display controllers initialize synchronously. Use Value: Eliminates display artifacts and measurement drift due to partial initialization during wake-up transitions. |
| Wearable Health Sensors | Low-Power IoT Edge Nodes |
|
Use Scenario: ECG patch using BLE SoC and rechargeable LiPo battery with dynamic voltage scaling. IC Role / Device Role / Timing Role: Supervises 3.0V regulated rail; asserts reset if voltage drops below 3.000V during RF transmission bursts. Use Value: Maintains data integrity by forcing controlled reboot instead of silent firmware lockup during transient load-induced brownout. |
Use Scenario: Environmental sensor node powered by energy harvesting (solar + supercapacitor). IC Role / Device Role / Timing Role: Detects VCC ramp-up from harvested energy; delays µP release for ≥600ms to ensure stable LDO output and radio calibration. Use Value: Avoids repeated boot loops during marginal energy availability, extending functional uptime per charge cycle. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar microprocessor supervisory applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| TPS3836K33DBVR | 3.08V reset threshold, 200ms timeout, 1.6µA ICC, SOT23-5 | Higher supply current limits use in >5-year battery applications; fixed timeout less flexible than D6 option | Select when lower cost and TI ecosystem alignment outweigh nanopower requirements |
| STM6315RWX6F | 3.00V threshold, 1.2s timeout, 1.5µA ICC, SOT23-5 | 10× higher ICC reduces battery life in coin-cell devices; wider tolerance (±3%) vs. MAX6855's ±2.5% | Prefer for ST-based designs where 1.5µA ICC is acceptable and long-term supply continuity is prioritized |
Compared with TPS3836K33DBVR and STM6315RWX6F, the MAX6855UK30D6+T delivers 10× lower supply current and tighter threshold accuracy - making it uniquely suited for decade-long deployments in medical wearables and remote sensors where every nanoamp matters.
Availability
MAX6855UK30D6+T is available at Aetrix Electronics and suitable for portable medical devices, battery-powered test equipment, and low-power IoT edge nodes requiring stable component supply with full traceability and lifecycle management.
Supply support for MAX6855UK30D6+T includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Maxim Integrated (now part of Analog Devices) designs precision analog, mixed-signal, and power management ICs for demanding industrial, medical, and communications applications.
The MAX6854–MAX6869 family targets ultra-low-power supervisory functions in space- and energy-constrained systems - emphasizing nanopower operation, guaranteed reset behavior down to 1.1V, and robustness against supply transients.
FAQ
What is the exact reset threshold voltage of the MAX6855UK30D6+T?
The MAX6855UK30D6+T has a factory-trimmed reset threshold of 3.000V, with ±2.5% tolerance over –40°C to +85°C. This value is confirmed in Table 2 (Threshold Suffix Guide) of the datasheet, where suffix "30" corresponds to 2.925V (min), 3.000V (typ), and 3.075V (max). The MAX6855UK30D6+T uses this precise threshold to reliably monitor 3.0V rails in portable medical devices.
Does the MAX6855UK30D6+T include a watchdog timer?
No, the MAX6855UK30D6+T does not include a watchdog timer. Per the Selector Guide and Pin Description sections, only MAX6864–MAX6869 variants integrate WDI functionality. The MAX6855UK30D6+T provides voltage monitoring, manual reset (MR), and fixed reset timeout - making it ideal for applications requiring simplicity and lowest possible ICC without watchdog supervision.
What is the function of Pin 4 on the MAX6855UK30D6+T?
Pin 4 on the MAX6855UK30D6+T is a second GND terminal, electrically tied to Pin 2 (GND). Both ground pins must be connected to the same low-impedance ground plane to ensure noise immunity and accurate reset timing. This dual-GND configuration reduces ground bounce effects during reset assertion and improves stability in high-noise portable environments where the MAX6855UK30D6+T is commonly deployed.
Can the MAX6855UK30D6+T operate from a 1.8V supply?
Yes, the MAX6855UK30D6+T operates from 1.2V to 5.5V, including 1.8V. Its reset output remains valid down to VCC = +1.1V, and supply current is specified at 170nA typical at VCC = 1.8V. This makes the MAX6855UK30D6+T suitable for modern ultra-low-voltage µPs and SoCs, such as those used in hearing aids and neural sensors, where 1.8V operation is standard.
Is the MAX6855UK30D6+T pin-compatible with other devices in the MAX68xx family?
The MAX6855UK30D6+T shares the same 5-pin SOT23-5 package and pinout (RESET–GND–MR–GND–VCC) with MAX6854, MAX6856, MAX6861–MAX6863, and MAX6864–MAX6869. However, output polarity and feature sets differ: MAX6855 offers active-high push-pull RESET, while MAX6855UK30D6+T is active-low. Always verify reset polarity and feature presence (e.g., CT, WDI) before substitution - the MAX6855UK30D6+T is not a drop-in replacement for MAX6855 variants with different suffixes.
MAX6855UK30D6+T Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Analog Devices Inc./Maxim Integrated
- Series:
- -
- Package/Case:
- SC-74A, SOT-753
- Packaging:
- Tape & Reel (TR)
- Product Status:
- Obsolete
- Programmable:
- Not Verified
- Type:
- Simple Reset/Power-On Reset
- Number of Voltages Monitored:
- 1
- Voltage - Threshold:
- 3V
- Output:
- Push-Pull, Totem Pole
- Reset:
- Active Low
- Reset Timeout:
- 600ms Minimum
- Operating Temperature:
- -40°C ~ 85°C (TA)
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- SOT-23-5
MAX6855UK30D6+T FAQ
1.How can I place an order for MAX6855UK30D6+T through Aetrix?
Please submit a Request for Quotation (RFQ) for MAX6855UK30D6+T on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MAX6855UK30D6+T reliable?
The price and inventory of MAX6855UK30D6+T are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MAX6855UK30D6+T is usually 5 days.
3.What payment methods are accepted for MAX6855UK30D6+T?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MAX6855UK30D6+T transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MAX6855UK30D6+T?
MAX6855UK30D6+T orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MAX6855UK30D6+T order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MAX6855UK30D6+T?
For technical support, including MAX6855UK30D6+T datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MAX6855UK30D6+T requirements.
6.How does Aetrix verify that MAX6855UK30D6+T is sourced from the original manufacturer or authorized distributors?
All MAX6855UK30D6+T products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MAX6855UK30D6+T meets industry standards.
7.What is the process for return or replacement of MAX6855UK30D6+T?
All MAX6855UK30D6+T units undergo pre-shipment inspection (PSI). If there is an issue with MAX6855UK30D6+T, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MAX6855UK30D6+T part is unused and in its original packaging.
Return procedure for MAX6855UK30D6+T:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MAX6855UK30D6+T Tags

-
MIC826SYMT-TR
Microchip Technology

-
APX803S-31SA-7
Diodes Incorporated

-
APX803L20-29SA-7
Diodes Incorporated
-
TPS3828-33DBVR
Texas Instruments

-
V6340RSP3B+
EM Microelectronic

-
EM6325CXSP5B-2.9+
EM Microelectronic

-
MCP120T-300I/TT
Microchip Technology

-
MCP130T-315I/TT
Microchip Technology

-
MCP120T-475I/TT
Microchip Technology

-
MCP111T-300E/TT
Microchip Technology

-
MCP120T-315I/TT
Microchip Technology

-
MCP809T-315I/TT
Microchip Technology
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…

