Analog Devices Inc./Maxim Integrated MAX6863UK225+T
- Part No.:
- MAX6863UK225+T
- Manufacturer:
- Analog Devices Inc./Maxim Integrated
- Category:
- Supervisors
- Package:
- SC-74A, SOT-753
- Datasheet:
-
MAX6863UK225+T.pdf
- Description:
- IC MPU SUPERVISOR SOT23-5
- Quantity:
- Payment:

- Shipping:

Inventory:4,365
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
The MAX6863UK225+T from Maxim Integrated is a nanopower microprocessor supervisory circuit in a 5-pin SOT23 package, featuring a factory-trimmed 2.235V reset threshold, pin-selectable 10ms/150ms (min) reset timeout, manual reset input (MR), and no watchdog timer. It asserts an active-low open-drain RESET output during VCC brownout, power-up, or MR assertion, and guarantees valid reset down to VCC = +1.1V. It targets ultra-low-power portable medical and consumer devices requiring reliable, low-current supervision.
For engineers reviewing the MAX6863UK225+T datasheet, MAX6863UK225+T pinout, MAX6863UK225+T application, or MAX6863UK225+T equivalent, key selection criteria include its 170nA typical supply current, 2.235V reset threshold tolerance (±2.5%), CT-pin configurable timeout, immunity to short VCC transients (<40µs at 100mV overdrive), and guaranteed operation across –40°C to +85°C.
Technical Context
The MAX6863UK225+T implements a precision voltage monitor with hysteresis (0.5% of VTH) and a digital timeout generator controlled by the CT pin-low selects D1 (10ms min), high selects D3 (150ms min). Its internal 10kΩ MR pullup enables direct switch-to-GND manual reset without external components.
It uses BiCMOS process technology (2848 transistors) to achieve ultra-low ICC (170nA typ at 2.5V) while maintaining robust noise immunity: MR glitch rejection is 200ns, and it remains immune to VCC transients ≤40µs when overdriven by 100mV below VTH. RESET output is open-drain, requiring external pullup, and sinks ≥50µA at VOL ≤0.3V (VCC ≥1.1V).
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Supply Current | 170nA typical at VCC = 1.8V; enables multi-year battery life in glucose monitors and wearables. |
| Reset Threshold | 2.235V ±2.5%; factory-trimmed for accuracy without calibration-matches common 2.2V/2.25V system rails. |
| Reset Timeout | Pin-selectable: 10ms (min) or 150ms (min); CT = GND → D1, CT = VCC → D3-no firmware or external RC needed. |
| Operating Voltage Range | VCC = 1.2V to 5.5V; valid reset asserted down to VCC = 1.1V-ensures supervision through deep brownout. |
| Reset Output Type | Active-low open-drain; supports level-shifting to µP logic supplies up to 5.5V via external pullup. |
| MR Input Logic | Active-low with 10kΩ internal pullup to VCC; accepts CMOS levels; 1µs minimum pulse width; 200ns glitch rejection. |
| Package | 5-pin SOT23-5; footprint-compatible with TPS3836/TPS3837/TPS3838-enables drop-in replacement in existing designs. |
Pinout & Package
MAX6863UK225+T is housed in a lead-free 5-pin SOT23-5 package (2.9mm × 1.6mm × 1.1mm), optimized for space-constrained portable PCBs. Pin 1 is CT (Reset Timeout Select), Pin 2 is GND, Pin 3 is MR (Manual Reset), Pin 4 is RESET (open-drain active-low), and Pin 5 is VCC.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 - CT | Reset Timeout Select Input | Logic level sets timeout: GND → 10ms (min), VCC → 150ms (min); no external components required. |
| 2 - GND | Ground Reference | Common return path for all internal circuits; must connect to system ground plane for noise immunity. |
| 3 - MR | Active-Low Manual Reset Input | Pull low to force reset; internally pulled up to VCC (10kΩ); compatible with momentary switches or logic drivers. |
| 4 - RESET | Open-Drain Active-Low Reset Output | Sinks current when asserted; requires external pullup resistor to target logic rail (e.g., 10kΩ to 3.3V). |
| 5 - VCC | Supply Voltage Input | Monitored rail input; bypass with 0.1µF ceramic capacitor to GND near pin for transient suppression. |
Key Features
| Feature | Design Value |
|---|---|
| Ultra-low supply current | 170nA typical at 2.5V-extends battery life in single-cell coin-cell applications like patient monitors. |
| Factory-trimmed reset threshold | 2.235V ±2.5%-eliminates need for external resistive dividers or calibration in production test. |
| Pin-selectable reset timeout | D1 (10ms min) or D3 (150ms min) via CT pin-supports both fast-boot and long-hold reset requirements in one BOM item. |
| Open-drain RESET with wide voltage compatibility | RESET sinks ≥50µA at VOL ≤0.3V (VCC ≥1.1V) and interfaces to logic rails up to 5.5V-simplifies mixed-voltage system design. |
| Guaranteed reset validity to VCC = 1.1V | Ensures deterministic reset behavior during deep brownout-critical for data integrity in memory-backed medical devices. |
Applications
| Glucose Monitors | Portable ECG Devices |
|---|---|
|
Use Scenario: Battery-powered handheld glucose meters operating from a single 3V CR2032 coin cell with intermittent sensor activation. IC Role / Device Role / Timing Role: Supervises 3.0V system rail and triggers hardware reset on brownout or user-initiated recalibration. Use Value: 170nA ICC extends battery life beyond 2 years; 2.235V threshold aligns precisely with ADC reference stability margin; CT pin allows timeout optimization for sensor warm-up timing. |
Use Scenario: Wearable single-lead ECG patch transmitting data via BLE, powered by rechargeable Li-ion with tight voltage regulation. IC Role / Device Role / Timing Role: Monitors 3.3V LDO output and asserts reset if voltage dips below safe operating range during RF transmission bursts. Use Value: Immunity to 40µs VCC transients prevents spurious resets during high-current BLE transmit events; open-drain RESET interfaces cleanly to BLE SoC's 1.8V reset input. |
| Smart Inhalers | Wireless Pulse Oximeters |
|
Use Scenario: Disposable Bluetooth-enabled inhaler tracking actuation count and environmental exposure using a 1.5V alkaline cell. IC Role / Device Role / Timing Role: Supervises stepped-up 2.2V rail powering MCU and sensor; CT pin configured for 10ms timeout to support rapid wake-from-sleep cycles. Use Value: Valid reset down to VCC = 1.1V ensures fail-safe shutdown before cell depletion; 10kΩ MR pullup enables direct push-button reset without added passives. |
Use Scenario: Clip-on fingertip pulse oximeter with OLED display, running on two AAA batteries with boost converter outputting 3.3V. IC Role / Device Role / Timing Role: Monitors 3.3V rail and provides 150ms reset hold time (CT = VCC) to ensure stable initialization of optical sensor and display driver. Use Value: Factory-trimmed 2.235V threshold avoids false resets during boost converter ripple; 150ms timeout exceeds typical OLED controller startup delay. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar microprocessor supervisory applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MAX6861UK225+T | Same 2.235V threshold and CT-selectable timeout, but features push-pull active-low RESET instead of open-drain. | Requires VCC-referenced RESET load; unsuitable where level-shifting to higher logic rails is needed. | Select MAX6861UK225+T only when driving a VCC-synchronous reset input and board layout prohibits external pullup. |
| TPS3836K23DBVR | Fixed 2.32V threshold, 200ms fixed timeout, push-pull active-low RESET, 1.5µA ICC-higher current, no CT pin. | Lacks timeout configurability and ultra-low ICC; not suitable for multi-year battery life requirements. | Choose TPS3836K23DBVR only for cost-sensitive, non-battery-critical industrial controls where 1.5µA ICC is acceptable. |
Compared with MAX6863UK225+T, MAX6861UK225+T offers identical supervision accuracy and timeout flexibility but trades open-drain versatility for lower BOM count in VCC-synchronous systems; TPS3836K23DBVR provides TI-qualified supply chain continuity but sacrifices nanopower operation and pin-level timeout control.
Availability
MAX6863UK225+T is available at Aetrix Electronics and suitable for glucose monitors, portable ECG devices, smart inhalers, and wireless pulse oximeters requiring stable component supply, long-term lifecycle support, and lead-free compliance.
Supply support for MAX6863UK225+T includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Maxim Integrated (now part of Analog Devices) designs precision analog and mixed-signal ICs for power, sensing, and interface applications in industrial, medical, and consumer markets.
The MAX6854–MAX6869 family delivers nanopower µP supervision with configurable timing and robust noise immunity-engineered specifically for battery-constrained portable medical and wearable electronics.
FAQ
What is the exact reset threshold voltage of the MAX6863UK225+T?
The MAX6863UK225+T has a factory-trimmed reset threshold of 2.235V, with guaranteed tolerance of ±2.5% over –40°C to +85°C. This value is confirmed in Table 2 (Threshold Suffix Guide) of the datasheet, where suffix "225" corresponds to VTH = 2.235V (min 2.180V, typ 2.235V, max 2.290V). The MAX6863UK225+T maintains this accuracy without external calibration.
How does the CT pin configure the reset timeout period on the MAX6863UK225+T?
On the MAX6863UK225+T, the CT pin selects between two minimum reset timeout periods: connecting CT to GND selects D1 (10ms min), and connecting CT to VCC selects D3 (150ms min). These values are specified in Table 1 and confirmed in the MAX6861/MAX6862/MAX6863 Pin Description section. The MAX6863UK225+T does not include a watchdog timer-CT exclusively controls timeout.
Is the MAX6863UK225+T pin-compatible with other supervisory ICs?
Yes-the MAX6863UK225+T is pin-compatible with the TPS3836/TPS3837/TPS3838 series per the datasheet's Features section. All share the same 5-pin SOT23-5 footprint and identical pin assignments (CT/MR/GND/RESET/VCC), enabling direct replacement in existing layouts where open-drain RESET and CT-based timeout selection are required.
What is the maximum supply voltage the MAX6863UK225+T can monitor?
The MAX6863UK225+T monitors VCC over a range of 1.2V to 5.5V, with guaranteed reset assertion down to VCC = 1.1V. Its absolute maximum rating for VCC is +6.0V (per Absolute Maximum Ratings table), but functional operation is only specified within 1.2V–5.5V. The MAX6863UK225+T is not rated for continuous operation above 5.5V.
Does the MAX6863UK225+T include a watchdog timer function?
No-the MAX6863UK225+T does not include a watchdog timer. It belongs to the MAX6861/MAX6862/MAX6863 subgroup, which features manual reset (MR) and pin-selectable timeout (CT) but omits WDI functionality. Watchdog capability is exclusive to MAX6864–MAX6869 variants (e.g., MAX6864UK225D3S+T), as confirmed in the Selector Guide and Pin Configurations sections.
MAX6863UK225+T Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Analog Devices Inc./Maxim Integrated
- Series:
- -
- Package/Case:
- SC-74A, SOT-753
- Packaging:
- Product Status:
- Active
- Programmable:
- Not Verified
- Type:
- Simple Reset/Power-On Reset
- Number of Voltages Monitored:
- 1
- Voltage - Threshold:
- 2.235V
- Output:
- Push-Pull, Totem Pole
- Reset:
- Active Low
- Reset Timeout:
- Adjustable/Selectable
- Operating Temperature:
- -40°C ~ 85°C (TA)
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- SOT-23-5
MAX6863UK225+T FAQ
1.How can I place an order for MAX6863UK225+T through Aetrix?
Please submit a Request for Quotation (RFQ) for MAX6863UK225+T on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MAX6863UK225+T reliable?
The price and inventory of MAX6863UK225+T are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MAX6863UK225+T is usually 5 days.
3.What payment methods are accepted for MAX6863UK225+T?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MAX6863UK225+T transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MAX6863UK225+T?
MAX6863UK225+T orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MAX6863UK225+T order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MAX6863UK225+T?
For technical support, including MAX6863UK225+T datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MAX6863UK225+T requirements.
6.How does Aetrix verify that MAX6863UK225+T is sourced from the original manufacturer or authorized distributors?
All MAX6863UK225+T products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MAX6863UK225+T meets industry standards.
7.What is the process for return or replacement of MAX6863UK225+T?
All MAX6863UK225+T units undergo pre-shipment inspection (PSI). If there is an issue with MAX6863UK225+T, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MAX6863UK225+T part is unused and in its original packaging.
Return procedure for MAX6863UK225+T:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MAX6863UK225+T Tags

-
MIC826SYMT-TR
Microchip Technology

-
APX803S-31SA-7
Diodes Incorporated

-
APX803L20-29SA-7
Diodes Incorporated
-
TPS3828-33DBVR
Texas Instruments

-
V6340RSP3B+
EM Microelectronic

-
EM6325CXSP5B-2.9+
EM Microelectronic

-
MCP120T-300I/TT
Microchip Technology

-
MCP130T-315I/TT
Microchip Technology

-
MCP120T-475I/TT
Microchip Technology

-
MCP111T-300E/TT
Microchip Technology

-
MCP120T-315I/TT
Microchip Technology

-
MCP809T-315I/TT
Microchip Technology
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…