Analog Devices Inc./Maxim Integrated MAX6863UK22+T
- Part No.:
- MAX6863UK22+T
- Manufacturer:
- Analog Devices Inc./Maxim Integrated
- Category:
- Supervisors
- Package:
- SC-74A, SOT-753
- Datasheet:
-
MAX6863UK22+T.pdf
- Description:
- IC SUPERVISOR 1 CHANNEL SOT23-5
- Quantity:
- Payment:

- Shipping:

Inventory:3,108
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MAX6863UK22+T from Maxim Integrated is a nanopower microprocessor supervisory circuit in 5-pin SOT23 package, featuring pin-selectable 10ms/150ms (min) reset timeout, active-low open-drain reset output, and manual reset input. It monitors VCC with factory-trimmed 2.235V reset threshold, guarantees valid reset down to VCC = +1.1V, and draws only 170nA typical supply current - ideal for battery-powered glucose monitors and portable medical devices.
For engineers reviewing the MAX6863UK22+T datasheet, MAX6863UK22+T pinout, MAX6863UK22+T application, or MAX6863UK22+T equivalent, key selection criteria include its 2.235V threshold accuracy, CT-pin programmable reset delay, immunity to short VCC transients (<40µs at 100mV overdrive), and compatibility with low-voltage µP systems operating down to 1.2V.
Technical Context
The MAX6863UK22+T implements a precision voltage monitor with ±2.5% threshold tolerance over -40°C to +85°C, coupled with a digital reset timeout generator controlled by the CT pin. Its internal 10kΩ MR pullup enables direct switch interfacing without external components.
Unlike watchdog-equipped variants (e.g., MAX6864–MAX6869), the MAX6863UK22+T omits WDI functionality and instead provides CT-based reset delay selection between D1 (10ms min) and D3 (150ms min) timeout options - confirmed in Table 1 and Pin Description for MAX6861/MAX6862/MAX6863.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Reset Threshold | 2.235V (factory-trimmed, ±2.5% tolerance) - ensures reliable brownout detection at nominal 2.2V rail |
| Supply Current | 170nA typical at VCC = 1.8V - enables multi-year operation on coin-cell batteries |
| Reset Timeout Options | 10ms or 150ms (min), selected via CT pin - supports fast recovery or extended hold-off in safety-critical boot sequences |
| Valid Reset Voltage Range | VCC ≥ 1.1V - guarantees reset assertion integrity during deep brownout conditions |
| Output Type | Active-low open-drain RESET - allows level-shifting to µP logic supplies up to 5.5V using external pullup |
| MR Input Behavior | Internally pulled up to VCC (10kΩ), accepts CMOS logic levels - eliminates need for external pullup in manual reset switch circuits |
Pinout & Package
MAX6863UK22+T is housed in a RoHS-compliant 5-pin SOT23-5 package (2.9mm × 1.6mm × 1.1mm), optimized for space-constrained portable designs.
| Pin | Circuit Role | Design Meaning |
|---|---|---|
| 1 | CT | Reset timeout select input: logic low → 10ms (min) timeout; logic high (VCC) → 150ms (min) timeout |
| 2 | GND | Ground reference for all internal circuitry and reset timing accuracy |
| 3 | MR | Active-low manual reset input; internally pulled up to VCC (10kΩ); 1µs minimum pulse width |
| 4 | RESET | Active-low open-drain reset output; requires external pullup resistor; sinks 50µA at VCC ≥ 1.1V |
| 5 | VCC | Supply voltage input (1.2V to 5.5V); monitored for reset assertion; bypass with 0.1µF capacitor to GND |
Key Features
| Feature | Design Value |
|---|---|
| Ultra-low supply current | 170nA typical enables >10-year battery life in always-on patient monitors |
| Pin-selectable reset delay | CT pin toggles between 10ms and 150ms timeout - no firmware or external RC network required |
| Guaranteed reset validity | RESET remains functional down to VCC = +1.1V - critical for Li-ion battery discharge monitoring |
| Transient immunity | Immune to VCC glitches ≤40µs at 100mV overdrive - prevents spurious resets in noisy ECG environments |
| No external components | Integrated MR pullup (10kΩ) and precision voltage reference eliminate BOM cost and layout area |
Applications
| Glucose Monitoring Systems | Patient Vital Sign Monitors |
|---|---|
Use Scenario: Continuous glucose sensing with Bluetooth LE transmission powered by CR2032 coin cell. IC Role / Device Role / Timing Role: Supervises 2.2V analog front-end and BLE SoC power rails; asserts reset if battery drops below 2.1V. Use Value: 170nA quiescent current extends sensor runtime beyond 2 years; 150ms timeout ensures stable ADC initialization before data acquisition. |
Use Scenario: Portable ECG device with dual-supply (1.8V analog, 3.3V digital) and motion-artifact rejection firmware. IC Role / Device Role / Timing Role: Monitors 1.8V analog rail; triggers hard reset on brownout to prevent corrupted waveform capture. Use Value: Valid reset down to VCC = 1.1V catches deep discharge before analog front-end fails; CT pin enables field-upgradable timeout via firmware-controlled GPIO. |
| Wearable Health Trackers | Industrial Handheld Scanners |
Use Scenario: Optical heart-rate sensor with photodiode array and low-power MCU, powered by rechargeable LiPo. IC Role / Device Role / Timing Role: Provides power-on reset and manual reset via tactile button; CT pin tied to VCC for 150ms delay. Use Value: Open-drain RESET interfaces directly to 1.8V MCU reset pin using 10kΩ pullup to 1.8V rail - no level shifter needed. |
Use Scenario: Rugged barcode scanner with cold-temperature operation (-20°C) and intermittent Wi-Fi upload. IC Role / Device Role / Timing Role: Supervises 3.3V main rail; manual reset used for factory calibration mode entry. Use Value: Immunity to 30µs VCC transients prevents false resets during motor-driven scan actuation; guaranteed operation at -40°C to +85°C ensures reliability in warehouse environments. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar microprocessor supervisory applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MAX6861UK22+T | Same 2.235V threshold and CT-selectable timeout, but push-pull active-low RESET output | Requires VCC-referenced reset signaling; unsuitable where level-shifting to higher-voltage logic is needed | Select when driving µP reset pins directly from same supply rail and board space permits slightly higher ICC (210nA typ) |
| TPS3836K22DBVR | Pin-compatible 5-pin SOT23, 2.2V threshold, fixed 200ms timeout, 1.6µA ICC | Higher supply current limits battery life; no CT pin flexibility; lacks transient immunity specs | Choose for cost-sensitive industrial controls where 170nA ultra-low ICC is not required and fixed timeout suffices |
Compared with MAX6861UK22+T, the MAX6863UK22+T's open-drain output enables flexible logic-level interfacing, while versus TPS3836K22DBVR, its 170nA current and CT configurability deliver superior energy efficiency and design adaptability in portable medical electronics.
Availability
MAX6863UK22+T is available at Aetrix Electronics and suitable for glucose monitoring systems, patient vital sign monitors, wearable health trackers, and industrial handheld scanners requiring stable component supply across extended product lifecycles.
Supply support for MAX6863UK22+T includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Maxim Integrated (now part of Analog Devices) designs precision analog and mixed-signal ICs for power, sensing, and connectivity in demanding environments.
The MAX6854–MAX6869 family delivers nanopower supervisory functions for battery-critical applications - engineered specifically for medical wearables, portable diagnostics, and ultra-low-power IoT endpoints where runtime and reliability are non-negotiable.
FAQ
What is the exact reset threshold voltage of the MAX6863UK22+T?
The MAX6863UK22+T features a factory-trimmed reset threshold of 2.235V, with ±2.5% tolerance over the full -40°C to +85°C temperature range. This value is confirmed in Table 2 (Threshold Suffix Guide) where suffix "22" corresponds to 2.235V, and is guaranteed in the Electrical Characteristics table under VTH parameter.
How does the CT pin configure the reset timeout on the MAX6863UK22+T?
On the MAX6863UK22+T, the CT pin selects between two minimum reset timeout periods: connecting CT to GND selects D1 (10ms min), while connecting CT to VCC selects D3 (150ms min). This behavior is explicitly defined in Table 1 and the MAX6861/MAX6862/MAX6863 Pin Description section of the datasheet.
Does the MAX6863UK22+T include a watchdog timer function?
No, the MAX6863UK22+T does not include a watchdog timer. It belongs to the MAX6861/MAX6862/MAX6863 subgroup, which provides only voltage monitoring and manual reset with CT-selectable timeout. Watchdog functionality is exclusive to MAX6864–MAX6869 variants, as confirmed in the Selector Guide and Functional Diagram.
What is the maximum supply voltage the MAX6863UK22+T can monitor?
The MAX6863UK22+T supports a supply voltage range of 1.2V to 5.5V on the VCC pin. Its reset function remains valid down to VCC = +1.1V, and absolute maximum rating allows VCC up to +6.0V - enabling safe use in 3.3V, 2.5V, and 1.8V systems with margin for transient overshoot.
Can the MAX6863UK22+T drive a reset input requiring active-high signaling?
No - the MAX6863UK22+T provides only an active-low open-drain RESET output. To interface with an active-high reset input, an external pullup resistor to the target logic supply must be used, and the host µP must interpret low-to-high transitions as reset deassertion. Active-high push-pull variants (e.g., MAX6862UK22+T) are separate part numbers.
MAX6863UK22+T Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Analog Devices Inc./Maxim Integrated
- Series:
- -
- Package/Case:
- SC-74A, SOT-753
- Packaging:
- Tape & Reel (TR)
- Product Status:
- Obsolete
- Programmable:
- Not Verified
- Type:
- Simple Reset/Power-On Reset
- Number of Voltages Monitored:
- 1
- Voltage - Threshold:
- 2.188V
- Output:
- Push-Pull, Totem Pole
- Reset:
- Active Low
- Reset Timeout:
- Adjustable/Selectable
- Operating Temperature:
- -40°C ~ 85°C (TA)
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- SOT-23-5
MAX6863UK22+T FAQ
1.How can I place an order for MAX6863UK22+T through Aetrix?
Please submit a Request for Quotation (RFQ) for MAX6863UK22+T on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MAX6863UK22+T reliable?
The price and inventory of MAX6863UK22+T are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MAX6863UK22+T is usually 5 days.
3.What payment methods are accepted for MAX6863UK22+T?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MAX6863UK22+T transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MAX6863UK22+T?
MAX6863UK22+T orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MAX6863UK22+T order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MAX6863UK22+T?
For technical support, including MAX6863UK22+T datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MAX6863UK22+T requirements.
6.How does Aetrix verify that MAX6863UK22+T is sourced from the original manufacturer or authorized distributors?
All MAX6863UK22+T products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MAX6863UK22+T meets industry standards.
7.What is the process for return or replacement of MAX6863UK22+T?
All MAX6863UK22+T units undergo pre-shipment inspection (PSI). If there is an issue with MAX6863UK22+T, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MAX6863UK22+T part is unused and in its original packaging.
Return procedure for MAX6863UK22+T:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MAX6863UK22+T Tags

-
MIC826SYMT-TR
Microchip Technology

-
APX803S-31SA-7
Diodes Incorporated

-
APX803L20-29SA-7
Diodes Incorporated
-
TPS3828-33DBVR
Texas Instruments

-
V6340RSP3B+
EM Microelectronic

-
EM6325CXSP5B-2.9+
EM Microelectronic

-
MCP120T-300I/TT
Microchip Technology

-
MCP130T-315I/TT
Microchip Technology

-
MCP120T-475I/TT
Microchip Technology

-
MCP111T-300E/TT
Microchip Technology

-
MCP120T-315I/TT
Microchip Technology

-
MCP809T-315I/TT
Microchip Technology
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…