Analog Devices Inc./Maxim Integrated MAX700EPA+
- Part No.:
- MAX700EPA+
- Manufacturer:
- Analog Devices Inc./Maxim Integrated
- Category:
- Supervisors
- Package:
- 8-DIP (0.300", 7.62mm)
- Datasheet:
-
MAX700EPA+.pdf
- Description:
- IC SUPERVISOR 1 CHANNEL 8DIP
- Quantity:
- Payment:

- Shipping:

Inventory:2,743
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MAX700EPA+ from Maxim Integrated is a precision power-supply supervisory circuit designed to monitor +5V systems and generate reliable reset signals during power-up, power-down, and brownout conditions. It features factory-trimmed 4.65V reset threshold, ≥200ms reset pulse width, manual-reset debouncing, and operates across -40°C to +85°C in 8-pin PDIP packaging. Used for critical µP power monitoring in industrial controllers and intelligent instruments.
For engineers reviewing the MAX700EPA+ datasheet, MAX700EPA+ pinout, MAX700EPA+ application, or MAX700EPA+ equivalent, key selection factors include guaranteed reset assertion down to VCC = 1V, adjustable voltage detection via SENSE/CTL pins, internal hysteresis control, and compatibility with lead-free PCB assembly due to the "+" suffix.
Technical Context
The MAX700EPA+ implements dual-comparator supervision: one monitors VCC directly (when CTL = GND), while another monitors external voltage via SENSE (when CTL = VCC) with 1.29V reference. Its internal oscillator and RC timing network ensure minimum 200ms reset pulse width independent of supply ramp rate.
Reset assertion occurs when VCC falls below 4.65V (±150mV over temperature) or when SENSE drops below 1.29V (±40mV). HYST pin enables programmable hysteresis by connecting an external resistor to ground, reducing noise-induced false resets during marginal supply conditions.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Reset Threshold | 4.65V ±150mV - ensures reliable reset activation for standard +5V systems across full -40°C to +85°C range |
| Reset Pulse Width | 200–500ms - guarantees sufficient duration to fully initialize microprocessors before release |
| VCC Valid Reset Range | 1.0V minimum - maintains correct RESET state even during deep brownout or slow power ramp-down |
| Supply Current | 100–200µA - enables low-power operation without compromising supervision accuracy |
| Manual-Reset Input | Debounced with 5µA internal pullup - eliminates switch bounce without external RC filtering |
| SENSE Threshold | 1.29V ±40mV - supports precise external voltage monitoring using resistor-divider networks |
| Hysteresis Control | Adjustable via HYST pin - allows user-defined hysteresis to suppress noise on monitored rails |
Pinout & Package
MAX700EPA+ uses an 8-pin plastic dual-inline package (PDIP) with 0.3-inch body width and through-hole mounting. Pin spacing conforms to JEDEC MS-001.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 MR | Manual Reset Input | Active-low debounced input with 5µA internal pullup; initiates reset when pulled below 0.7V |
| 2 SENSE | Voltage Sense Input | Monitors external voltage when CTL = VCC; threshold = 1.29V; high-impedance (0.1nA leakage) |
| 3 HYST | Hysteresis Control | Connects to GND via resistor to set hysteresis width; on-resistance ≈1kΩ when active |
| 4 GND | Ground Reference | Primary return path for all internal comparators and output drivers |
| 5 RESET | Active-Low Reset Output | Open-drain output capable of sinking 16mA at VCC = 4.25V; logic low ≤0.4V |
| 6 RESET | Active-High Reset Output | Push-pull output sourcing up to 3.2mA; logic high ≥VCC − 0.4V |
| 7 CTL | Control Select | Selects monitoring mode: GND = VCC monitoring; VCC = SENSE monitoring |
| 8 VCC | Power Supply Input | Accepts +3V to +15.5V; powers internal circuitry and serves as reference for VCC monitoring |
Key Features
| Feature | Design Value |
|---|---|
| Preset 4.65V reset threshold | Factory-trimmed to ±150mV over -40°C to +85°C - eliminates calibration effort in +5V systems |
| Adjustable voltage detection | SENSE input with 1.29V reference enables custom thresholds (e.g., 3.3V, 2.5V) using external resistors |
| Programmable hysteresis | HYST pin allows user-defined hysteresis width - prevents chatter during noisy or slowly varying supply conditions |
| Guaranteed reset at low VCC | Valid RESET/RESET states maintained down to VCC = 1.0V - ensures deterministic behavior during deep undervoltage |
| Debounced manual reset | Internal hardware debounce removes switch bounce - no external RC components required |
Applications
| Industrial PLC Controllers | Medical Diagnostic Instruments |
|---|---|
Use Scenario: Monitoring 5V auxiliary power rail in programmable logic controller backplanes subject to transient load switching and EMI. IC Role / Device Role / Timing Role: Supervisory circuit asserting RESET until stable 5V is confirmed, then holding reset for ≥200ms before release. Use Value: Prevents firmware corruption during power transients by guaranteeing minimum reset pulse width and valid reset state down to 1V. | Use Scenario: Ensuring safe boot sequence in portable ultrasound units where battery voltage may dip during high-current transducer firing. IC Role / Device Role / Timing Role: Dual-mode supervisor using SENSE input to track regulated 3.3V rail derived from Li-ion battery, with hysteresis to reject ripple. Use Value: Enables accurate low-voltage detection at 3.3V using resistor divider on SENSE, avoiding reliance on less-stable VCC monitoring. |
| Telecom Line Cards | Energy Metering Modules |
Use Scenario: Power sequencing validation in carrier-grade Ethernet switches exposed to wide ambient temperature swings (-40°C to +85°C). IC Role / Device Role / Timing Role: Temperature-hardened reset generator ensuring µP initialization integrity across full industrial grade range. Use Value: Eliminates need for external temperature compensation or recalibration - 4.65V threshold remains within spec over entire operating range. | Use Scenario: Monitoring isolated DC-DC converter output powering metrology ASICs in smart electricity meters. IC Role / Device Role / Timing Role: Supervisory IC asserting RESET if isolated 5V rail falls below 4.5V, with manual override via front-panel button. Use Value: Debounced MR input allows field-service reset without adding external debounce circuitry or firmware overhead. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar power-supply supervision applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| TPS3808G33DBVR | Fixed 3.3V reset threshold; no SENSE/HYST pins; 200ms min pulse; 1.8–6V VCC range | Designed for 3.3V systems only; lacks adjustable threshold or hysteresis control | Choose for cost-sensitive 3.3V-only designs where external voltage monitoring is unnecessary |
| ADM6713ARZ-46 | 4.63V threshold; no manual reset; no adjustable hysteresis; 240ms min pulse; SOIC-8 | Single-output (RESET only); no SENSE capability; fixed hysteresis (~100mV) | Prefer when board space is constrained and dual reset outputs or external sensing are not required |
Compared with TPS3808G33DBVR and ADM6713ARZ-46, the MAX700EPA+ uniquely supports both VCC and external SENSE monitoring modes, offers user-adjustable hysteresis, and provides complementary RESET/RESET outputs - making it suitable for complex multi-rail systems requiring flexible supervision architecture.
Availability
MAX700EPA+ is available at Aetrix Electronics and suitable for industrial PLC controllers, medical diagnostic instruments, and telecom line cards requiring stable component supply across extended temperature ranges and RoHS-compliant manufacturing.
Supply support for MAX700EPA+ includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Maxim Integrated, now part of Analog Devices, designs precision analog, mixed-signal, and power-management ICs for industrial, automotive, communications, and computing applications.
The MAX700 family delivers highly reliable power-supply supervision with configurable monitoring modes and robust reset timing - engineered specifically for mission-critical embedded systems demanding fail-safe startup and brownout recovery.
FAQ
What is the guaranteed minimum reset pulse width for MAX700EPA+?
The MAX700EPA+ guarantees a minimum reset pulse width of 200ms during power-up, power-down, and low-voltage conditions. This timing is generated by an internal RC oscillator and is independent of VCC ramp rate. The actual pulse width ranges from 200ms to 500ms depending on process and temperature variation. This ensures microprocessors receive sufficient reset hold time before release, preventing premature execution.
Can MAX700EPA+ monitor voltages other than +5V?
Yes, the MAX700EPA+ can monitor non-5V supplies using its SENSE input. When CTL is tied to VCC, the internal 1.29V reference compares against the voltage applied to SENSE. By using an external resistor divider, users can scale any input voltage (e.g., 3.3V, 2.5V, or 12V) to match the 1.29V threshold. This enables flexible supervision of diverse system rails without changing the MAX700EPA+ itself.
Does MAX700EPA+ require external components for basic +5V supervision?
No, the MAX700EPA+ requires zero external components for standard +5V supervision. Its factory-trimmed 4.65V reset threshold, debounced MR input, and internal timing network eliminate the need for external resistors, capacitors, or diodes. Only VCC, GND, MR (optional), and RESET/RESET connections are needed - reducing BOM count, board area, and qualification effort in production designs.
What does the '+' suffix in MAX700EPA+ indicate?
The '+' suffix in MAX700EPA+ indicates lead(Pb)-free, RoHS-compliant packaging. It specifies that the 8-pin PDIP device meets JEDEC J-STD-609 Category 1 marking requirements and uses matte-tin plating instead of traditional lead-based finishes. This enables compliance with environmental regulations and compatibility with modern Pb-free solder reflow profiles without altering electrical or thermal performance.
How does hysteresis work on MAX700EPA+?
Hysteresis on the MAX700EPA+ is implemented via the HYST pin, which connects to ground through an external resistor when SENSE monitoring is enabled (CTL = VCC). The internal HYST switch turns on ~5µs before RESET activation and presents ~1kΩ resistance to GND. This creates a voltage offset at the SENSE comparator input, widening the gap between turn-on and turn-off thresholds - suppressing false resets caused by supply noise or ripple near the trip point.
MAX700EPA+ Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Analog Devices Inc./Maxim Integrated
- Series:
- -
- Package/Case:
- 8-DIP (0.300", 7.62mm)
- Packaging:
- Tube
- Product Status:
- Active
- Programmable:
- Not Verified
- Type:
- Simple Reset/Power-On Reset
- Number of Voltages Monitored:
- 1
- Voltage - Threshold:
- Adjustable/Selectable
- Output:
- Push-Pull, Push-Pull
- Reset:
- Active High/Active Low
- Reset Timeout:
- 200ms Minimum
- Operating Temperature:
- -40°C ~ 85°C (TA)
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Through Hole
- Supplier Device Package:
- 8-PDIP
MAX700EPA+ FAQ
1.How can I place an order for MAX700EPA+ through Aetrix?
Please submit a Request for Quotation (RFQ) for MAX700EPA+ on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MAX700EPA+ reliable?
The price and inventory of MAX700EPA+ are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MAX700EPA+ is usually 5 days.
3.What payment methods are accepted for MAX700EPA+?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MAX700EPA+ transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MAX700EPA+?
MAX700EPA+ orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MAX700EPA+ order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MAX700EPA+?
For technical support, including MAX700EPA+ datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MAX700EPA+ requirements.
6.How does Aetrix verify that MAX700EPA+ is sourced from the original manufacturer or authorized distributors?
All MAX700EPA+ products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MAX700EPA+ meets industry standards.
7.What is the process for return or replacement of MAX700EPA+?
All MAX700EPA+ units undergo pre-shipment inspection (PSI). If there is an issue with MAX700EPA+, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MAX700EPA+ part is unused and in its original packaging.
Return procedure for MAX700EPA+:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MAX700EPA+ Tags

-
MIC826SYMT-TR
Microchip Technology

-
APX803S-31SA-7
Diodes Incorporated

-
APX803L20-29SA-7
Diodes Incorporated
-
TPS3828-33DBVR
Texas Instruments

-
V6340RSP3B+
EM Microelectronic

-
EM6325CXSP5B-2.9+
EM Microelectronic

-
MCP120T-300I/TT
Microchip Technology

-
MCP130T-315I/TT
Microchip Technology

-
MCP120T-475I/TT
Microchip Technology

-
MCP111T-300E/TT
Microchip Technology

-
MCP120T-315I/TT
Microchip Technology

-
MCP809T-315I/TT
Microchip Technology
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…