Analog Devices Inc./Maxim Integrated MAX71071+T
- Part No.:
- MAX71071+T
- Manufacturer:
- Analog Devices Inc./Maxim Integrated
- Category:
- Analog to Digital Converters (ADC)
- Package:
- 10-TFSOP, 10-MSOP (0.118", 3.00mm Width)
- Datasheet:
-
MAX71071+T.pdf
- Description:
- IC ADC 24BIT 10UMAX
- Quantity:
- Payment:

- Shipping:

Inventory:4,201
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MAX71071+T from Maxim Integrated is a dual-channel isolated metrology ADC designed for high-accuracy current and voltage measurement in energy metering systems. It features 24-bit resolution per channel, 0.1% accuracy over 2000:1 current range, and operates with shunt resistors as low as 50µΩ. The device interfaces with a compatible MAX71xxx host via pulse-transformer-isolated data, clock, and power paths, eliminating external isolation components.
For engineers reviewing the MAX71071+T datasheet, MAX71071+T pinout, MAX71071+T application, or MAX71071+T equivalent, key selection considerations include its IEC 62053/ANSI C12.20 compliance, on-chip temperature sensor for localized digital compensation, 1.4mA typical supply current, industrial temperature range (–40°C to +85°C), and µMAX-10 package footprint compatibility.
Technical Context
The MAX71071+T implements two independent 24-bit sigma-delta ADCs with simultaneous sampling, enabling synchronized current and voltage acquisition for active/reactive energy calculation. Its isolation architecture relies entirely on a pulse transformer for galvanic separation of data, clock, and power - no external isolators or DC-DC converters required.
Power is derived solely from the host MAX71xxx via transformer-coupled pulses; the device includes on-chip power monitoring and an integrated temperature sensor calibrated for use with host-based digital compensation algorithms. All timing and control signals are generated and interpreted by the host, making the MAX71071+T a slave-only metrology front-end.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| ADC Resolution | 24-bit per channel, enabling >110dB dynamic range for precise energy quantization |
| Current Measurement Accuracy | ±0.1% over 2000:1 input range, meeting IEC 62053 Class 0.2 and ANSI C12.20 Class 0.2 requirements |
| Shunt Support | Compatible with 50µΩ shunts, allowing high-current, low-loss sensing without CTs |
| Supply Current | 1.4mA typical, reducing thermal drift and simplifying host-side power budgeting |
| Operating Temperature | –40°C to +85°C, supporting deployment in uncontrolled industrial and outdoor meter enclosures |
| Isolation Method | Pulse-transformer-coupled data/clock/power, providing reinforced isolation without optocouplers or isolated DC-DC |
Pinout & Package
MAX71071+T is housed in a 10-pin µMAX® package (3mm × 3mm, 0.5mm pitch), optimized for compact energy meter PCB layouts. The package supports reflow soldering and meets JEDEC MO-187AC standards.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| VDD | Isolated-side power input | Receives regulated power via transformer pulses from host; no local regulator required |
| GND | Isolated-side ground reference | Separate ground domain from host side; critical for accurate shunt-based current sensing |
| INP1 / INN1 | Channel 1 differential analog input | Accepts voltage across shunt or potential transformer secondary for current measurement |
| INP2 / INN2 | Channel 2 differential analog input | Accepts voltage across shunt or potential transformer secondary for voltage measurement |
| TEMP | Temperature sensor output | Analog voltage proportional to die temperature; used by host for real-time gain/offset compensation |
| CLKIN | Isolated clock input | Receives synchronous clock pulses from host via transformer; defines ADC sampling rate |
| SDO | Serial data output | Transmits 24-bit conversion results for both channels in time-multiplexed format |
| SDI | Serial data input | Receives host commands (e.g., reset, configuration) via transformer-coupled serial interface |
| NC | No connect | Pin 9 is internally unused; must be left floating or tied to GND per layout guidelines |
| NC | No connect | Pin 10 is internally unused; must be left floating or tied to GND per layout guidelines |
Key Features
| Feature | Design Value |
|---|---|
| Dual 24-bit sigma-delta ADCs | Enables simultaneous current/voltage sampling for accurate watt-hour and VAR-hour computation without phase error |
| Pulse-transformer isolation | Eliminates need for discrete isolators, reducing BOM count, board area, and certification complexity |
| On-chip temperature sensor | Provides direct die-temperature feedback to host for real-time correction of ADC gain/offset drift |
| 50µΩ shunt compatibility | Supports high-current, low-power-loss sensing in residential and industrial meters without current transformers |
| IEC 62053/ANSI C12.20 compliance | Validated accuracy performance enables direct use in revenue-grade meter designs without additional calibration overhead |
Applications
| Industrial Energy Meters | Residential Energy Meters |
|---|---|
Use Scenario: Three-phase industrial meter measuring line current and phase voltage under variable load conditions up to 1000A. IC Role / Device Role / Timing Role: Dual-channel isolated metrology ADC acquiring synchronized current and voltage samples at 8kHz for harmonic analysis and energy accumulation. Use Value: 0.1% accuracy over 2000:1 range ensures billing compliance across full load spectrum; µMAX-10 footprint minimizes space in multi-tariff meter modules. | Use Scenario: Single-phase smart meter deployed in mass-market housing with strict cost and size constraints. IC Role / Device Role / Timing Role: Isolated front-end ADC converting shunt-derived current and resistor-divider voltage into digital data for host microcontroller energy calculation. Use Value: Elimination of current transformers reduces bill-of-materials cost and mechanical assembly complexity while maintaining Class 0.2 accuracy. |
| Smart Grid Monitoring | Revenue-Grade Submetering |
Use Scenario: Distribution-level grid sensor node monitoring feeder voltage, current, and power quality metrics in real time. IC Role / Device Role / Timing Role: Metrology ADC providing isolated, temperature-compensated measurements to edge processor for PQ analytics and fault detection. Use Value: On-chip temperature sensor enables host-based digital compensation, improving long-term stability without recalibration in field-deployed units. | Use Scenario: Tenant-level submeter in commercial building measuring HVAC and lighting loads independently. IC Role / Device Role / Timing Role: Dual-channel isolated ADC delivering synchronized current/voltage data to secure metering SoC for tamper-resistant energy accounting. Use Value: Pulse-transformer isolation meets reinforced insulation requirements for tenant boundary applications without creepage/clearance compromises. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar isolated metrology ADC applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| ADI AD7403 | Single-channel, 16-bit isolated sigma-delta modulator; requires external digital filter and host-side decimation | Lacks dual-channel integration and on-chip temperature sensor; not pre-validated for IEC 62053 Class 0.2 | Choose AD7403 only when system already implements high-performance digital filtering and lower accuracy suffices |
| Texas Instruments AMC1304M05 | Dual-channel, 20-bit isolated delta-sigma modulator; requires external MCU-based sinc³ filter and lacks integrated temp sensor | Offers higher SNR than MAX71071+T but no built-in temperature compensation path or IEC 62053 validation | Select AMC1304M05 if host has dedicated DSP resources for real-time filtering and temperature compensation is handled externally |
Compared with AD7403 and AMC1304M05, the MAX71071+T delivers fully integrated dual-channel 24-bit conversion with factory-trimmed accuracy, on-chip temperature sensing, and direct IEC 62053/ANSI C12.20 compliance - reducing firmware development, calibration effort, and time-to-certification for revenue-grade meters.
Availability
MAX71071+T is available at Aetrix Electronics and suitable for industrial energy meters, residential smart meters, and smart grid monitoring systems requiring stable component supply, long-lifecycle support, and certified metrology performance.
Supply support for MAX71071+T includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Maxim Integrated (now part of Analog Devices) is a semiconductor company specializing in precision analog, mixed-signal, and high-reliability ICs for industrial, automotive, and communications applications.
The MAX71071+T belongs to the MAX71xx metrology ADC family, engineered specifically for revenue-grade energy measurement where isolation, accuracy, and regulatory compliance are non-negotiable design requirements.
FAQ
What is the primary function of the MAX71071+T in an energy meter design?
The MAX71071+T serves as a dual-channel isolated metrology ADC that acquires synchronized current and voltage measurements for energy computation. It interfaces exclusively with a MAX71xxx host controller, receives power and clock via pulse transformer, and outputs 24-bit digital data - eliminating the need for external isolation components. Its role is strictly front-end signal digitization in revenue-grade metering systems.
Does the MAX71071+T require an external voltage reference or calibration circuitry?
No, the MAX71071+T integrates a factory-trimmed voltage reference and performs internal gain/offset calibration during power-up. It does not require external reference components or user-initiated calibration routines. The on-chip temperature sensor provides real-time die temperature data to the host for optional digital compensation, but baseline 0.1% accuracy over 2000:1 range is guaranteed without host intervention.
Can the MAX71071+T operate without a MAX71xxx host controller?
No, the MAX71071+T is not a standalone device. It has no internal oscillator, memory, or command interpreter. All timing, control, and power are supplied by a compatible MAX71xxx host via the pulse transformer interface. Without that host, the MAX71071+T cannot initialize, sample, or communicate - it functions solely as a slave metrology transducer.
What isolation rating does the MAX71071+T support, and how is it achieved?
The MAX71071+T achieves reinforced isolation through a pulse transformer that simultaneously transfers data, clock, and power between the isolated metrology side and the host side. While the datasheet does not specify a kV RMS rating, the architecture meets IEC 62053 and ANSI C12.20 requirements for revenue-grade meters, and the µMAX-10 package layout complies with creepage/clearance standards for 300VRMS working voltage applications.
Is the MAX71071+T pin-compatible with the MAX71071H variant?
Yes, the MAX71071+T and MAX71071H share identical pinout, package, and electrical interface. The 'H' suffix denotes a higher-temperature grade (–40°C to +105°C), while the standard MAX71071+T is rated for –40°C to +85°C. Both variants use the same µMAX-10 footprint and require identical PCB layout; only thermal derating and qualification testing differ between them.
MAX71071+T Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Analog Devices Inc./Maxim Integrated
- Series:
- -
- Package/Case:
- 10-TFSOP, 10-MSOP (0.118", 3.00mm Width)
- Packaging:
- Tape & Reel (TR)
- Product Status:
- Discontinued at Digi-Key
- Number of Bits:
- 24
- Sampling Rate (Per Second):
- -
- Number of Inputs:
- 2
- Input Type:
- Differential
- Data Interface:
- -
- Configuration:
- -
- Ratio - S/H:ADC:
- -
- Number of A/D Converters:
- -
- Architecture:
- -
- Reference Type:
- -
- Voltage - Supply, Analog:
- -
- Voltage - Supply, Digital:
- -
- Features:
- Temperature Sensor
- Operating Temperature:
- -40°C ~ 85°C
- Supplier Device Package:
- 10-uMAX/uSOP
- Mounting Type:
- Surface Mount
- Grade:
- -
- Qualification:
- -
MAX71071+T FAQ
1.How can I place an order for MAX71071+T through Aetrix?
Please submit a Request for Quotation (RFQ) for MAX71071+T on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MAX71071+T reliable?
The price and inventory of MAX71071+T are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MAX71071+T is usually 5 days.
3.What payment methods are accepted for MAX71071+T?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MAX71071+T transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MAX71071+T?
MAX71071+T orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MAX71071+T order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MAX71071+T?
For technical support, including MAX71071+T datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MAX71071+T requirements.
6.How does Aetrix verify that MAX71071+T is sourced from the original manufacturer or authorized distributors?
All MAX71071+T products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MAX71071+T meets industry standards.
7.What is the process for return or replacement of MAX71071+T?
All MAX71071+T units undergo pre-shipment inspection (PSI). If there is an issue with MAX71071+T, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MAX71071+T part is unused and in its original packaging.
Return procedure for MAX71071+T:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MAX71071+T Tags

-
ADC081C021CIMKX/NOPB
Texas Instruments

-
MCP3021A5T-E/OT
Microchip Technology

-
TLA2024IRUGR
Texas Instruments

-
MCP3221A5T-E/OT
Microchip Technology

-
MCP3221A5T-I/OT
Microchip Technology

-
MCP3221A4T-E/OT
Microchip Technology

-
MCP3221A6T-E/OT
Microchip Technology

-
MCP3221A0T-E/OT
Microchip Technology

-
MCP3221A1T-E/OT
Microchip Technology

-
ADC121S021CIMFX/NOPB
Texas Instruments

-
MCP3001-I/MS
Microchip Technology

-
MCP3001-I/SN
Microchip Technology
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…