Send an Inquiry

To receive a quote for your project, please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Part Number*
Quantity*
Message
Submit Inventory List

Please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Upload My List
Message

Analog Devices Inc./Maxim Integrated MAX71071+T

Part No.:
MAX71071+T
Manufacturer:
Analog Devices Inc./Maxim Integrated
Category:
Analog to Digital Converters (ADC)
Package:
10-TFSOP, 10-MSOP (0.118", 3.00mm Width)
Datasheet:
AetrixMAX71071+T.pdf
Description:
IC ADC 24BIT 10UMAX
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:4,201

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

MAX71071+T from Maxim Integrated is a dual-channel isolated metrology ADC designed for high-accuracy current and voltage measurement in energy metering systems. It features 24-bit resolution per channel, 0.1% accuracy over 2000:1 current range, and operates with shunt resistors as low as 50µΩ. The device interfaces with a compatible MAX71xxx host via pulse-transformer-isolated data, clock, and power paths, eliminating external isolation components.

For engineers reviewing the MAX71071+T datasheet, MAX71071+T pinout, MAX71071+T application, or MAX71071+T equivalent, key selection considerations include its IEC 62053/ANSI C12.20 compliance, on-chip temperature sensor for localized digital compensation, 1.4mA typical supply current, industrial temperature range (–40°C to +85°C), and µMAX-10 package footprint compatibility.

Technical Context

The MAX71071+T implements two independent 24-bit sigma-delta ADCs with simultaneous sampling, enabling synchronized current and voltage acquisition for active/reactive energy calculation. Its isolation architecture relies entirely on a pulse transformer for galvanic separation of data, clock, and power - no external isolators or DC-DC converters required.

Power is derived solely from the host MAX71xxx via transformer-coupled pulses; the device includes on-chip power monitoring and an integrated temperature sensor calibrated for use with host-based digital compensation algorithms. All timing and control signals are generated and interpreted by the host, making the MAX71071+T a slave-only metrology front-end.

Key Specifications

ParameterValue and Actual Design Meaning
ADC Resolution24-bit per channel, enabling >110dB dynamic range for precise energy quantization
Current Measurement Accuracy±0.1% over 2000:1 input range, meeting IEC 62053 Class 0.2 and ANSI C12.20 Class 0.2 requirements
Shunt SupportCompatible with 50µΩ shunts, allowing high-current, low-loss sensing without CTs
Supply Current1.4mA typical, reducing thermal drift and simplifying host-side power budgeting
Operating Temperature–40°C to +85°C, supporting deployment in uncontrolled industrial and outdoor meter enclosures
Isolation MethodPulse-transformer-coupled data/clock/power, providing reinforced isolation without optocouplers or isolated DC-DC

Pinout & Package

MAX71071+T is housed in a 10-pin µMAX® package (3mm × 3mm, 0.5mm pitch), optimized for compact energy meter PCB layouts. The package supports reflow soldering and meets JEDEC MO-187AC standards.

Pin/TerminalCircuit RoleDesign Meaning
VDDIsolated-side power inputReceives regulated power via transformer pulses from host; no local regulator required
GNDIsolated-side ground referenceSeparate ground domain from host side; critical for accurate shunt-based current sensing
INP1 / INN1Channel 1 differential analog inputAccepts voltage across shunt or potential transformer secondary for current measurement
INP2 / INN2Channel 2 differential analog inputAccepts voltage across shunt or potential transformer secondary for voltage measurement
TEMPTemperature sensor outputAnalog voltage proportional to die temperature; used by host for real-time gain/offset compensation
CLKINIsolated clock inputReceives synchronous clock pulses from host via transformer; defines ADC sampling rate
SDOSerial data outputTransmits 24-bit conversion results for both channels in time-multiplexed format
SDISerial data inputReceives host commands (e.g., reset, configuration) via transformer-coupled serial interface
NCNo connectPin 9 is internally unused; must be left floating or tied to GND per layout guidelines
NCNo connectPin 10 is internally unused; must be left floating or tied to GND per layout guidelines

Key Features

FeatureDesign Value
Dual 24-bit sigma-delta ADCsEnables simultaneous current/voltage sampling for accurate watt-hour and VAR-hour computation without phase error
Pulse-transformer isolationEliminates need for discrete isolators, reducing BOM count, board area, and certification complexity
On-chip temperature sensorProvides direct die-temperature feedback to host for real-time correction of ADC gain/offset drift
50µΩ shunt compatibilitySupports high-current, low-power-loss sensing in residential and industrial meters without current transformers
IEC 62053/ANSI C12.20 complianceValidated accuracy performance enables direct use in revenue-grade meter designs without additional calibration overhead

Applications

Industrial Energy MetersResidential Energy Meters

Use Scenario: Three-phase industrial meter measuring line current and phase voltage under variable load conditions up to 1000A.

IC Role / Device Role / Timing Role: Dual-channel isolated metrology ADC acquiring synchronized current and voltage samples at 8kHz for harmonic analysis and energy accumulation.

Use Value: 0.1% accuracy over 2000:1 range ensures billing compliance across full load spectrum; µMAX-10 footprint minimizes space in multi-tariff meter modules.

Use Scenario: Single-phase smart meter deployed in mass-market housing with strict cost and size constraints.

IC Role / Device Role / Timing Role: Isolated front-end ADC converting shunt-derived current and resistor-divider voltage into digital data for host microcontroller energy calculation.

Use Value: Elimination of current transformers reduces bill-of-materials cost and mechanical assembly complexity while maintaining Class 0.2 accuracy.

Smart Grid MonitoringRevenue-Grade Submetering

Use Scenario: Distribution-level grid sensor node monitoring feeder voltage, current, and power quality metrics in real time.

IC Role / Device Role / Timing Role: Metrology ADC providing isolated, temperature-compensated measurements to edge processor for PQ analytics and fault detection.

Use Value: On-chip temperature sensor enables host-based digital compensation, improving long-term stability without recalibration in field-deployed units.

Use Scenario: Tenant-level submeter in commercial building measuring HVAC and lighting loads independently.

IC Role / Device Role / Timing Role: Dual-channel isolated ADC delivering synchronized current/voltage data to secure metering SoC for tamper-resistant energy accounting.

Use Value: Pulse-transformer isolation meets reinforced insulation requirements for tenant boundary applications without creepage/clearance compromises.

Equivalent & Alternatives

The following parts are listed as comparable options for similar isolated metrology ADC applications.

Alternative PartTechnical DifferenceApplication DifferenceSelection Advice
ADI AD7403Single-channel, 16-bit isolated sigma-delta modulator; requires external digital filter and host-side decimationLacks dual-channel integration and on-chip temperature sensor; not pre-validated for IEC 62053 Class 0.2Choose AD7403 only when system already implements high-performance digital filtering and lower accuracy suffices
Texas Instruments AMC1304M05Dual-channel, 20-bit isolated delta-sigma modulator; requires external MCU-based sinc³ filter and lacks integrated temp sensorOffers higher SNR than MAX71071+T but no built-in temperature compensation path or IEC 62053 validationSelect AMC1304M05 if host has dedicated DSP resources for real-time filtering and temperature compensation is handled externally

Compared with AD7403 and AMC1304M05, the MAX71071+T delivers fully integrated dual-channel 24-bit conversion with factory-trimmed accuracy, on-chip temperature sensing, and direct IEC 62053/ANSI C12.20 compliance - reducing firmware development, calibration effort, and time-to-certification for revenue-grade meters.

Availability

MAX71071+T is available at Aetrix Electronics and suitable for industrial energy meters, residential smart meters, and smart grid monitoring systems requiring stable component supply, long-lifecycle support, and certified metrology performance.

Supply support for MAX71071+T includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

Maxim Integrated (now part of Analog Devices) is a semiconductor company specializing in precision analog, mixed-signal, and high-reliability ICs for industrial, automotive, and communications applications.

The MAX71071+T belongs to the MAX71xx metrology ADC family, engineered specifically for revenue-grade energy measurement where isolation, accuracy, and regulatory compliance are non-negotiable design requirements.

FAQ

What is the primary function of the MAX71071+T in an energy meter design?

The MAX71071+T serves as a dual-channel isolated metrology ADC that acquires synchronized current and voltage measurements for energy computation. It interfaces exclusively with a MAX71xxx host controller, receives power and clock via pulse transformer, and outputs 24-bit digital data - eliminating the need for external isolation components. Its role is strictly front-end signal digitization in revenue-grade metering systems.

Does the MAX71071+T require an external voltage reference or calibration circuitry?

No, the MAX71071+T integrates a factory-trimmed voltage reference and performs internal gain/offset calibration during power-up. It does not require external reference components or user-initiated calibration routines. The on-chip temperature sensor provides real-time die temperature data to the host for optional digital compensation, but baseline 0.1% accuracy over 2000:1 range is guaranteed without host intervention.

Can the MAX71071+T operate without a MAX71xxx host controller?

No, the MAX71071+T is not a standalone device. It has no internal oscillator, memory, or command interpreter. All timing, control, and power are supplied by a compatible MAX71xxx host via the pulse transformer interface. Without that host, the MAX71071+T cannot initialize, sample, or communicate - it functions solely as a slave metrology transducer.

What isolation rating does the MAX71071+T support, and how is it achieved?

The MAX71071+T achieves reinforced isolation through a pulse transformer that simultaneously transfers data, clock, and power between the isolated metrology side and the host side. While the datasheet does not specify a kV RMS rating, the architecture meets IEC 62053 and ANSI C12.20 requirements for revenue-grade meters, and the µMAX-10 package layout complies with creepage/clearance standards for 300VRMS working voltage applications.

Is the MAX71071+T pin-compatible with the MAX71071H variant?

Yes, the MAX71071+T and MAX71071H share identical pinout, package, and electrical interface. The 'H' suffix denotes a higher-temperature grade (–40°C to +105°C), while the standard MAX71071+T is rated for –40°C to +85°C. Both variants use the same µMAX-10 footprint and require identical PCB layout; only thermal derating and qualification testing differ between them.

MAX71071+T Specifications

Product attributes
Attribute value
Manufacturer:
Analog Devices Inc./Maxim Integrated
Series:
-
Package/Case:
10-TFSOP, 10-MSOP (0.118", 3.00mm Width)
Packaging:
Tape & Reel (TR)
Product Status:
Discontinued at Digi-Key
Number of Bits:
24
Sampling Rate (Per Second):
-
Number of Inputs:
2
Input Type:
Differential
Data Interface:
-
Configuration:
-
Ratio - S/H:ADC:
-
Number of A/D Converters:
-
Architecture:
-
Reference Type:
-
Voltage - Supply, Analog:
-
Voltage - Supply, Digital:
-
Features:
Temperature Sensor
Operating Temperature:
-40°C ~ 85°C
Supplier Device Package:
10-uMAX/uSOP
Mounting Type:
Surface Mount
Grade:
-
Qualification:
-

MAX71071+T FAQ

1.How can I place an order for MAX71071+T through Aetrix?

Please submit a Request for Quotation (RFQ) for MAX71071+T on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for MAX71071+T reliable?

The price and inventory of MAX71071+T are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MAX71071+T is usually 5 days.

3.What payment methods are accepted for MAX71071+T?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MAX71071+T transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for MAX71071+T?

MAX71071+T orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your MAX71071+T order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for MAX71071+T?

For technical support, including MAX71071+T datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MAX71071+T requirements.

6.How does Aetrix verify that MAX71071+T is sourced from the original manufacturer or authorized distributors?

All MAX71071+T products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MAX71071+T meets industry standards.

7.What is the process for return or replacement of MAX71071+T?

All MAX71071+T units undergo pre-shipment inspection (PSI). If there is an issue with MAX71071+T, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The MAX71071+T part is unused and in its original packaging.

Return procedure for MAX71071+T:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

MAX71071+T Tags

  • MAX71071+T
  • MAX71071+T PDF
  • MAX71071+T Datasheet
  • MAX71071+T Specifications
  • MAX71071+T Images
  • Analog Devices Inc./Maxim Integrated
  • Analog Devices Inc./Maxim Integrated MAX71071+T
  • Buy MAX71071+T
  • MAX71071+T Price
  • MAX71071+T Distributor
  • MAX71071+T Supplier
  • MAX71071+T Wholesale
Related Products
ADC081C021CIMKX/NOPB
ADC081C021CIMKX/NOPB

Texas Instruments

MCP3021A5T-E/OT
MCP3021A5T-E/OT

Microchip Technology

TLA2024IRUGR
TLA2024IRUGR

Texas Instruments

MCP3221A5T-E/OT
MCP3221A5T-E/OT

Microchip Technology

MCP3221A5T-I/OT
MCP3221A5T-I/OT

Microchip Technology

MCP3221A4T-E/OT
MCP3221A4T-E/OT

Microchip Technology

MCP3221A6T-E/OT
MCP3221A6T-E/OT

Microchip Technology

MCP3221A0T-E/OT
MCP3221A0T-E/OT

Microchip Technology

MCP3221A1T-E/OT
MCP3221A1T-E/OT

Microchip Technology

ADC121S021CIMFX/NOPB
ADC121S021CIMFX/NOPB

Texas Instruments

MCP3001-I/MS
MCP3001-I/MS

Microchip Technology

MCP3001-I/SN
MCP3001-I/SN

Microchip Technology

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER