Monolithic Power Systems Inc. MCS1802GS-40-P
- Part No.:
- MCS1802GS-40-P
- Manufacturer:
- Monolithic Power Systems Inc.
- Category:
- Current Sensors
- Package:
- 8-SOIC (0.154", 3.90mm Width)
- Datasheet:
-
MCS1802GS-40-P.pdf
- Description:
- 3.3V, LINEAR HALL-EFFECT CURRENT
- Quantity:
- Payment:

- Shipping:

Inventory:4,243
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MCS1802GS-40-P from Monolithic Power Systems is a galvanically isolated, linear Hall-effect current sensor optimized for ±40A bidirectional DC/AC sensing with ±2.5% total output error over -40°C to +125°C, 33 mV/A sensitivity, and 2.2kVRMS isolation. It replaces optocouplers in motor control, power supply fault protection, and automotive load monitoring where high accuracy, low conductor resistance (0.9mΩ), and fast response (4µs rise time) are required.
For engineers reviewing the MCS1802GS-40-P datasheet, MCS1802GS-40-P pinout, MCS1802GS-40-P application, or MCS1802GS-40-P equivalent, key selection criteria include its SOIC-8 package with integrated primary conductor, differential Hall architecture for stray-field immunity, ratiometric 3.3V analog output, adjustable bandwidth up to 100kHz via external FILT capacitor, and factory-trimmed offset stability across temperature.
Technical Context
The MCS1802GS-40-P implements a differential Hall array with spinning current offset cancellation, enabling stable zero-current output (VCC/2) and ±2.5% total error over full temperature range. Its internal 0.9mΩ primary conductor supports high-current sensing while minimizing power loss and thermal drift.
Galvanic isolation is achieved via physical separation between IP+/IP− leads and signal pins (VCC/VOUT/FILT/GND), delivering 2.2kVRMS withstand voltage and 4.2mm creepage/clearance per IEC62368-1. Bandwidth is programmable from <10kHz to 100kHz using an external capacitor on the FILT pin, leveraging internal 1.5kΩ resistor and 1nF capacitor.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Supply Voltage | 3.3V nominal; operates from 3.0V–3.6V - ensures compatibility with standard logic rails and low-noise LDOs. |
| Current Range | ±40A bidirectional - supports high-power motor drives and industrial SMPS overcurrent detection. |
| Sensitivity | 33 mV/A - enables precise analog current measurement with minimal gain-stage amplification. |
| Total Output Error | ±2.5% over -40°C to +125°C - guarantees accuracy without system-level calibration across automotive and industrial environments. |
| Rise Time | 4 µs - allows real-time fault detection in fast-switching inverters and digital power controllers. |
| Isolation Voltage | 2.2kVRMS - meets reinforced insulation requirements for safety-critical AC mains interfaces and EV battery management. |
| Conductor Resistance | 0.9 mΩ - reduces self-heating (<1.44W at 40A) and improves efficiency in high-current paths. |
| Bandwidth | Up to 100kHz (FILT unconnected) - supports high-frequency current waveform capture in Class D audio and resonant converters. |
Pinout & Package
SOIC-8 package (5mm × 4mm, 1.27mm pitch) with integrated primary current path and galvanically isolated signal side. Primary terminals (IP+, IP−) are internally shorted pairs rated for high-current conduction; signal pins (VCC, VOUT, FILT, GND) reside on opposite side for isolation integrity.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1, 2 IP+ | Primary current input (+) | Low-inductance, parallel-connected entry point for sensed current; shares internal 0.9mΩ conductor path with IP−. |
| 3, 4 IP− | Primary current return (−) | Paired with IP+ to complete isolated current loop; same potential as IP+ pins under DC conditions. |
| 5 GND | Signal ground reference | Analog ground for VOUT and internal circuitry; must be star-connected to minimize noise coupling into Hall sensors. |
| 6 FILT | Bandwidth filter node | Connects to external capacitor (CF) to set 3dB cutoff; open-circuit yields max 100kHz bandwidth. |
| 7 VOUT | Analog output | Ratiometric voltage proportional to IP (±40A → ±1.32V around VCC/2); drives 4.7kΩ min load. |
| 8 VCC | 3.3V supply input | Requires local 1µF low-ESR ceramic bypass; UVLO triggers at 2.5V to prevent invalid output during brownout. |
Key Features
| Feature | Design Value |
|---|---|
| Differential Hall sensing | Rejects uniform external magnetic fields (e.g., nearby inductors/motors) via spatially separated transducers and spinning current offset cancellation. |
| Galvanic isolation | 2.2kVRMS withstand voltage with 4.2mm creepage/clearance - eliminates need for external isolators in IEC62368-1-compliant designs. |
| Factory-trimmed accuracy | ±2.5% total output error over temperature without user calibration - reduces BOM count and production test time. |
| Adjustable bandwidth | Configurable 3dB point from ~10kHz to 100kHz using single external CF capacitor - balances noise rejection vs. transient response. |
| Ratiometric output | VOUT scales with VCC (KSENS = 98–102%, KVO = 99–101%) - maintains accuracy despite supply rail variation in noisy power systems. |
| No magnetic hysteresis | Zero remanent field memory - ensures repeatable measurements across bidirectional current cycles in servo and regenerative braking applications. |
Applications
| Motor Control | Automotive Systems |
|---|---|
Use Scenario: Real-time phase current monitoring in 3-phase BLDC inverter for field-oriented control (FOC). IC Role / Device Role / Timing Role: Isolated analog current feedback sensor with 4µs rise time and ±40A range, placed on low-side shunt path. Use Value: Enables precise torque regulation and overcurrent shutdown within 5µs response time, preventing IGBT desaturation faults. | Use Scenario: High-voltage battery pack current monitoring in 48V mild-hybrid vehicles. IC Role / Device Role / Timing Role: Bidirectional DC current sensor interfacing between battery disconnect switch and MCU ADC. Use Value: Delivers ±2.5% accuracy across -40°C to +125°C ambient, supporting ASIL-B functional safety diagnostics without external calibration. |
| Switch-Mode Power Supplies | Over-Current Fault Protection |
Use Scenario: Input/output current sensing in 1–3kW telecom rectifiers with active PFC and LLC stages. IC Role / Device Role / Timing Role: Primary-side current monitor feeding peak-current-mode controller; bandwidth set to 50kHz via 100pF FILT capacitor. Use Value: Maintains stable loop response while rejecting EMI from adjacent magnetics due to differential Hall architecture. | Use Scenario: Fast-trip overcurrent detection in industrial PLC output modules driving solenoids and contactors. IC Role / Device Role / Timing Role: Isolated current limiter with propagation delay <1.5µs, triggering hardware shutdown before fuse blow. Use Value: Replaces optocoupler-based solutions with higher reliability, longer lifetime, and no LED aging drift. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar linear Hall-effect current sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| ACS724LLCB-40AU-T | 5V supply, ±40A range, 50mV/A sensitivity, 2.4kVRMS isolation, SOIC-8W package with wider creepage. | Higher supply voltage requirement limits use in 3.3V-only systems; larger package increases board area. | Select when 5V rail is available and enhanced creepage (>5mm) is mandated by end-equipment safety standards. |
| TLE4971-2500S5-S | 3.3V supply, ±40A range, 33mV/A sensitivity, 2.5kVRMS isolation, but requires external RC filter for bandwidth control. | Lacks integrated FILT pin; bandwidth tuning requires two external components and occupies more PCB space. | Choose if design already uses TLE497x family and needs consistent layout practices across multiple current sensors. |
Compared with ACS724LLCB-40AU-T and TLE4971-2500S5-S, the MCS1802GS-40-P offers tighter total error (±2.5% vs. ±3.5% and ±3.0%), native 3.3V operation without level-shifting, and single-capacitor bandwidth adjustment - simplifying design validation and reducing component count in space-constrained industrial drives.
Availability
MCS1802GS-40-P is available at Aetrix Electronics and suitable for motor control, automotive battery management, and industrial switch-mode power supplies requiring stable component supply, long-term lifecycle support, and RoHS-compliant sourcing.
Supply support for MCS1802GS-40-P includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Monolithic Power Systems (MPS) is a fabless semiconductor company specializing in high-performance power management ICs, including DC/DC converters, LED drivers, and precision analog sensors.
The MCS1802 product line delivers isolated current sensing for demanding industrial and automotive applications, emphasizing accuracy, galvanic isolation, and integration to replace discrete optocoupler-based solutions.
FAQ
What is the maximum continuous primary current the MCS1802GS-40-P can handle without derating?
The device is rated for ±40A continuous primary current with guaranteed ±2.5% total output error. At 40A, power dissipation in the 0.9mΩ conductor is 1.44W. Thermal performance depends on PCB copper area and airflow; for sustained 40A operation, a minimum 200mm² 2oz copper pour per IP+ and IP− is recommended to maintain junction temperature ≤125°C.
How does the FILT pin affect noise and bandwidth trade-offs?
Connecting a capacitor (CF) between FILT and GND forms a first-order low-pass filter with internal 1.5kΩ resistor and 1nF capacitor. A 100pF CF sets ~100kHz bandwidth with ~50mA(RMS) noise; 1nF reduces bandwidth to ~10kHz and noise to ~5mA(RMS). This allows designers to optimize for either fast transient response or low-noise steady-state measurement.
Can the MCS1802GS-40-P measure AC current waveforms accurately?
Yes - it provides true linear response to both AC and DC currents up to 100kHz bandwidth. At 50/60Hz, total error remains within ±2.5% across temperature. For high-fidelity AC measurement (e.g., energy metering), ensure VOUT load ≥4.7kΩ and use shielded routing to minimize capacitive coupling of switching noise into the analog output path.
What is the meaning of "ratiometric output" for this sensor?
Ratiometric output means both sensitivity (mV/A) and zero-current output voltage (VCC/2) scale proportionally with VCC supply voltage. If VCC varies from 3.0V to 3.6V, VOUT at ±40A shifts from ±1.20V to ±1.44V, and offset stays at exactly half the rail. This preserves measurement accuracy without recalibration when using non-regulated or noisy 3.3V supplies.
Is external filtering required on the VOUT pin for ADC interfacing?
No external RC filter is mandatory, as the device includes internal filtering. However, for 12-bit+ ADCs in noisy environments, a 10Ω series resistor + 10nF capacitor to GND at the VOUT pin reduces high-frequency noise without affecting bandwidth. Ensure the RC time constant is <100ns to avoid distorting the 4µs rise time critical for fault detection.
Does the MCS1802GS-40-P require calibration during production?
No - it is factory-trimmed for sensitivity and offset, achieving ±2.5% total output error over temperature without user calibration. System-level calibration may still be applied for sub-1% accuracy targets, but is not required for most motor control, PSU protection, and battery monitoring applications specified in the datasheet.
What safety certifications apply to the isolation barrier?
The isolation barrier is type-tested per IEC62368-1 for 2.2kVRMS withstand voltage and 100% production tested. It meets basic insulation requirements for functional isolation in industrial equipment (IEC61800-5-1) and automotive battery systems (ISO26262 ASIL-B), but is not certified for reinforced insulation in medical or mains-connected applications without additional system-level validation.
MCS1802GS-40-P Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Monolithic Power Systems Inc.
- Series:
- -
- Package/Case:
- 8-SOIC (0.154", 3.90mm Width)
- Packaging:
- Tape & Reel (TR)
- Product Status:
- Active
- For Measuring:
- AC/DC
- Sensor Type:
- Hall Effect
- Current - Sensing:
- 40A
- Number of Channels:
- 1
- Output:
- Ratiometric, Voltage
- Sensitivity:
- 33mV/A
- Frequency:
- 100kHz
- Linearity:
- ±0.5%
- Accuracy:
- ±2.5%
- Voltage - Supply:
- 3V ~ 3.6V
- Response Time:
- 5µs
- Current - Supply (Max):
- 10.5mA
- Operating Temperature:
- -40°C ~ 125°C (TJ)
- Grade:
- -
- Qualification:
- -
- Polarization:
- Bidirectional
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- 8-SOIC
MCS1802GS-40-P FAQ
1.How can I place an order for MCS1802GS-40-P through Aetrix?
Please submit a Request for Quotation (RFQ) for MCS1802GS-40-P on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MCS1802GS-40-P reliable?
The price and inventory of MCS1802GS-40-P are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MCS1802GS-40-P is usually 5 days.
3.What payment methods are accepted for MCS1802GS-40-P?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MCS1802GS-40-P transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MCS1802GS-40-P?
MCS1802GS-40-P orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MCS1802GS-40-P order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MCS1802GS-40-P?
For technical support, including MCS1802GS-40-P datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MCS1802GS-40-P requirements.
6.How does Aetrix verify that MCS1802GS-40-P is sourced from the original manufacturer or authorized distributors?
All MCS1802GS-40-P products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MCS1802GS-40-P meets industry standards.
7.What is the process for return or replacement of MCS1802GS-40-P?
All MCS1802GS-40-P units undergo pre-shipment inspection (PSI). If there is an issue with MCS1802GS-40-P, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MCS1802GS-40-P part is unused and in its original packaging.
Return procedure for MCS1802GS-40-P:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MCS1802GS-40-P Tags

-
ACS711KEXLT-31AB-T
Allegro MicroSystems

-
ACS711KEXLT-15AB-T
Allegro MicroSystems

-
CT110FDV-ID6
Allegro MicroSystems

-
ACS71240KEXBLT-010B3
Allegro MicroSystems

-
TMCS1108A3BQDR
Texas Instruments

-
ACS711ELCTR-12AB-T
Allegro MicroSystems

-
ACS711ELCTR-25AB-T
Allegro MicroSystems

-
ACS711KLCTR-12AB-T
Allegro MicroSystems

-
ACS711KLCTR-25AB-T
Allegro MicroSystems

-
ACS70331EESATR-005B3
Allegro MicroSystems

-
ACS70331EESATR-2P5U3
Allegro MicroSystems

-
ACS70331EESATR-2P5B3
Allegro MicroSystems
Tech Hub
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…
LDO regulator guide covering low dropout voltage, power dissipation, thermal design, PSRR, output noise, capacitor stability, adjustable LDO circuits, LDO vs buck converter and datasheet selection chec…
Conditional Access Module guide covering CAM meaning, CI/CI+ interface, smart card authorization, DVB security workflow, TV and set-top box compatibility, internal electronics, ESD protection, connecto…
Guide to electronic component obsolescence covering EOL risk, PCN/PDN notices, last-time buy planning, replacement options, form-fit-function validation, counterfeit risk and BOM lifecycle management.
18650 battery guide covering lithium-ion cell basics, 3.6V/3.7V voltage, 4.2V charging, mAh and Wh capacity, protected cells, chargers, BMS, series-parallel packs, holders, welding and sourcing checks.…
Hall effect sensor guide covering working principle, linear and digital sensors, Arduino circuits, current sensing, speed detection, automotive applications, A3144 examples, signal filtering and datash…
Product Change Notification guide for electronic components, covering PCN meaning, PCN vs PDN/EOL, common change types, risk levels, form-fit-function review, engineering validation, BOM control, LTB/L…
A practical guide to blend door actuators, covering HVAC function, symptoms, location, AC and heater issues, reset and calibration, replacement cost, electrical diagnosis, compatibility checks, and rep…
Engineering guide to Raspberry Pi alternatives, covering chip-level differences, Orange Pi, ROCK, Jetson, Banana Pi, NanoPi, Compute Module, Pico, GPIO, camera, HAT compatibility, and replacement risks…

.jpg)