Melexis Technologies NV MLX90316SDC-BCG-000-TU
- Part No.:
- MLX90316SDC-BCG-000-TU
- Manufacturer:
- Melexis Technologies NV
- Category:
- Angle, Linear Position Measuring
- Package:
- 8-SOIC (0.154", 3.90mm Width)
- Datasheet:
-
MLX90316SDC-BCG-000-TU.pdf
- Description:
- SENSOR ROTARY 360DEG SMD
- Quantity:
- Payment:

- Shipping:

Inventory:1,605
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MLX90316SDC-BCG-000-TU from Melexis is an absolute rotary position sensor IC based on Triaxis® Hall technology, delivering 12-bit angular resolution and ±1° thermal accuracy over -40°C to +125°C. It supports ratiometric analog, PWM, or serial output modes and features programmable angular range up to 360°, linear transfer characteristic, and integrated magneto-concentrator for robust airgap tolerance in automotive throttle and steering wheel position sensing.
For engineers reviewing the MLX90316SDC-BCG-000-TU datasheet, pinout, applications, or equivalent options, key selection criteria include its SOIC-8 package, 12-bit angular resolution, programmable output transfer function, dual-die redundancy option, and compatibility with PTC-04 end-of-line calibration.
Technical Context
The MLX90316SDC-BCG-000-TU integrates a Triaxis® magnetic front-end with on-chip DSP to compute absolute angular position from sine/cosine magnetic field components. Its IMC enables contactless sensing of rotating dipole magnets with high immunity to mechanical misalignment.
It supports three configurable output protocols - ratiometric analog (0–100% VDD), 12-bit PWM (100–1000 Hz), or 14-bit SPI serial - all programmable via VDD/VSS/OUT pins using the PTC-04 unit. The device includes EEPROM-stored calibration data, 40-bit ID, and diagnostics including broken-track detection.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Angular Resolution | 12-bit (0.0879°/LSB) for analog/PWM; 14-bit (0.022°/LSB) for SPI output |
| Thermal Angular Accuracy | ±1° over full temperature range (-40°C to +125°C) |
| Programmable Range | Up to 360° continuous rotation, with user-defined start/end points |
| Output Modes | Ratiometric analog, PWM (100–1000 Hz), or 3-wire SPI serial protocol |
| Supply Voltage | 4.5–5.5 V; reverse voltage protection to -10 V |
| Operating Temperature | -40°C to +125°C (K-grade), qualified per AEC-Q100 Grade 0 |
| Package | SOIC-8, RoHS-compliant, surface-mount |
Pinout & Package
MLX90316SDC-BCG-000-TU is housed in an 8-pin SOIC package with exposed pad (RoHS-compliant). Pin functions are defined per the standard Analog/PWM configuration; unused test pins must be grounded for EMC compliance.
| Pin | Circuit Role | Design Meaning |
|---|---|---|
| 1 | VDD | 5 V supply input; internal 3.3 V regulator powers digital core |
| 2 | Test 0 | Factory test pin; must be connected to VSS for normal operation |
| 3 | Switch OUT | Programmable digital switch output (open-drain, 0.55–4.35 V swing) |
| 4 | Not Used / OUT2 | No connection in SDC-BCG-000 variant; reserved for dual-output versions |
| 5 | OUT | Main analog/PWM output; ratiometric 0–100% VDD or PWM signal |
| 6 | Test 1 | Factory test pin; must be connected to VSS for normal operation |
| 7 | VDIG | Digital I/O supply reference; tied internally to VDD |
| 8 | VSS | Ground reference for analog and digital sections; critical for noise immunity |
Key Features
| Feature | Design Value |
|---|---|
| Triaxis® IMC Sensing | Enables contactless, high-tolerance angular measurement without external flux concentrators |
| End-of-Line Programmability | Full transfer function (offset, gain, clamping, linearity, filtering) calibrated via PTC-04 using only VDD/VSS/OUT |
| Dual-Die Redundancy Option | Available in TSSOP-16 (GO package); SDC-BCG-000 is single-die SOIC-8 |
| Integrated Diagnostics | Built-in broken-VDD/VSS detection, watchdog timer, and configurable diagnostic output |
| 40-Bit Unique ID | Factory-programmed ID stored in EEPROM for traceability and secure system identification |
Applications
| Steering Wheel Position Sensing | Throttle Position Sensing |
|---|---|
Use Scenario: Contactless angular measurement of steering column rotation in EPS systems under vibration, temperature cycling, and EMI. IC Role / Device Role / Timing Role: Absolute position transducer converting magnet rotation into ratiometric analog or PWM signal synchronized to vehicle bus timing. Use Value: Eliminates potentiometer wear and wiper noise; maintains ±1° accuracy across -40°C to +125°C with no recalibration. | Use Scenario: Real-time pedal angle feedback in drive-by-wire throttle bodies exposed to under-hood heat and oil mist. IC Role / Device Role / Timing Role: Primary angular sensor feeding engine control unit (ECU) with fail-safe PWM output compliant with ISO 26262 ASIL-B requirements. Use Value: Programmable clamping and deadzone prevent erroneous actuation during idle or wide-open throttle transitions. |
| Pedal Position Sensing | Motor Shaft Position Sensing |
Use Scenario: Brake or accelerator pedal angle detection in commercial vehicles where dust ingress and mechanical shock are common. IC Role / Device Role / Timing Role: Robust magnetic position encoder interfacing directly to vehicle CAN gateway via analog/PWM output. Use Value: Integrated magneto-concentrator ensures stable operation despite ±0.5 mm airgap variation and ±2° off-axis misalignment. | Use Scenario: Commutation feedback for BLDC motors in HVAC actuators or seat adjusters operating at 10,000+ cycles. IC Role / Device Role / Timing Role: High-resolution angular resolver replacement providing 12-bit position data at 1 kHz update rate. Use Value: 12-bit resolution and <600 μs step response enable precise closed-loop motor control without external interpolation. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar absolute rotary position sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MLX90363KGO-ABD-000-SP | TSSOP-16 dual-die package with full redundancy; SPI-only interface; higher integration of diagnostics | Targeted at ASIL-D safety-critical systems requiring hardware-level fault containment | Select when functional safety certification (ISO 26262) and dual-channel independence are mandatory |
| AS5055A-DSOM | 14-bit resolution, SPI-only output, no analog/PWM; requires external MCU for calibration; no integrated IMC | Suitable for compact PCB layouts where magnetic design flexibility outweighs ease of integration | Select when board space is constrained and magnetic field optimization is handled externally |
Compared with MLX90316SDC-BCG-000-TU, the MLX90363 offers hardware redundancy but sacrifices analog/PWM flexibility, while the AS5055A delivers higher resolution at the cost of calibration complexity and reduced mechanical tolerance - making the MLX90316SDC-BCG-000-TU optimal for cost-sensitive, high-volume automotive position sensing with rapid time-to-market.
Availability
MLX90316SDC-BCG-000-TU is available at Aetrix Electronics and suitable for automotive throttle position sensing, steering angle measurement, brake pedal monitoring, and industrial motor shaft feedback requiring stable component supply across extended temperature ranges and long production lifecycles.
Supply support for MLX90316SDC-BCG-000-TU includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Melexis is a Belgian semiconductor company specializing in magnetic sensing, driver ICs, and automotive ASICs, with over 25 years of expertise in contactless position and current sensing.
The MLX90316 belongs to Melexis' Triaxis® rotary position sensor family, designed specifically for high-reliability, non-contact angular measurement in automotive powertrain and chassis systems where durability, precision, and AEC-Q100 compliance are essential.
FAQ
What output modes does the MLX90316SDC-BCG-000-TU support?
The MLX90316SDC-BCG-000-TU supports three factory-configurable output modes: ratiometric analog (0–100% VDD), PWM (100–1000 Hz, 12-bit resolution), and 3-wire SPI serial (14-bit angular data). All modes are programmable via the PTC-04 unit using only VDD, VSS, and OUT pins - no dedicated programming interface is required. The MLX90316SDC-BCG-000-TU defaults to analog mode after power-up unless reconfigured.
Does the MLX90316SDC-BCG-000-TU require an external magnet, and what type is recommended?
Yes, the MLX90316SDC-BCG-000-TU requires an external diametrically magnetized neodymium (NdFeB) or samarium-cobalt (SmCo) dipole magnet positioned above the IC surface (end-of-shaft configuration). Recommended magnet size is Ø4 × 2 mm with Br ≥ 1.2 T; field strength at sensor surface must stay within 20–70 mT for optimal linearity. The integrated magneto-concentrator (IMC) enables operation with ±0.5 mm airgap tolerance - no external flux guides needed.
What is the angular accuracy specification of the MLX90316SDC-BCG-000-TU over temperature?
The MLX90316SDC-BCG-000-TU delivers ±1° total angular error over its full operating range of -40°C to +125°C. This includes contributions from intrinsic linearity error (±1° at 25°C), thermal offset drift (±60 LSB₁₅ ≈ ±0.3°), and thermal sensitivity mismatch (±0.3%). Accuracy is maintained without recalibration due to on-chip DSP compensation and EEPROM-stored calibration coefficients programmed during end-of-line testing.
Can the MLX90316SDC-BCG-000-TU be used in safety-critical automotive applications?
Yes - the MLX90316SDC-BCG-000-TU is AEC-Q100 Grade 0 qualified (-40°C to +125°C) and includes built-in diagnostics such as broken-VDD/VSS detection, watchdog timer, and configurable diagnostic output. While it is a single-die device, its robust magnetic sensing, programmable clamping/deadzone, and EEPROM-stored calibration support ASIL-B system integration. For ASIL-D, Melexis offers the dual-die MLX90363 in TSSOP-16 package.
How is the MLX90316SDC-BCG-000-TU calibrated, and what tools are required?
The MLX90316SDC-BCG-000-TU is calibrated end-of-line using Melexis' PTC-04 programming unit, which communicates exclusively through the VDD–VSS–OUT pins - no additional interface lines or debug headers are needed. Calibration configures angular range, transfer function (offset/gain/clamping), filtering, and diagnostics. Factory-default settings are stored in 128 B EEPROM; users can reprogram in-system via the same 3-pin interface using PTC-04 firmware v4.0 or later.
MLX90316SDC-BCG-000-TU Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Melexis Technologies NV
- Package/Case:
- 8-SOIC (0.154", 3.90mm Width)
- Series:
- Triaxis®
- Packaging:
- Tube
- Product Status:
- Discontinued at Digi-Key
- Programmable:
- -
- For Measuring:
- Rotary Position
- Technology:
- Hall Effect
- Rotation Angle - Electrical, Mechanical:
- 0° ~ 360°, Continuous
- Linear Range:
- -
- Output:
- Analog Voltage
- Output Signal:
- -
- Actuator Type:
- External Magnet, Not Included
- Linearity:
- ±1°
- Resistance:
- -
- Resistance Tolerance:
- -
- Voltage - Supply:
- 4.5V ~ 5.5V
- Mounting Type:
- Surface Mount
- Termination Style:
- Gull Wing
- Operating Temperature:
- -20°C ~ 85°C
- Grade:
- -
- Qualification:
- -
- Supplier Device Package:
- 8-SOIC
MLX90316SDC-BCG-000-TU FAQ
1.How can I place an order for MLX90316SDC-BCG-000-TU through Aetrix?
Please submit a Request for Quotation (RFQ) for MLX90316SDC-BCG-000-TU on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MLX90316SDC-BCG-000-TU reliable?
The price and inventory of MLX90316SDC-BCG-000-TU are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MLX90316SDC-BCG-000-TU is usually 5 days.
3.What payment methods are accepted for MLX90316SDC-BCG-000-TU?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MLX90316SDC-BCG-000-TU transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MLX90316SDC-BCG-000-TU?
MLX90316SDC-BCG-000-TU orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MLX90316SDC-BCG-000-TU order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MLX90316SDC-BCG-000-TU?
For technical support, including MLX90316SDC-BCG-000-TU datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MLX90316SDC-BCG-000-TU requirements.
6.How does Aetrix verify that MLX90316SDC-BCG-000-TU is sourced from the original manufacturer or authorized distributors?
All MLX90316SDC-BCG-000-TU products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MLX90316SDC-BCG-000-TU meets industry standards.
7.What is the process for return or replacement of MLX90316SDC-BCG-000-TU?
All MLX90316SDC-BCG-000-TU units undergo pre-shipment inspection (PSI). If there is an issue with MLX90316SDC-BCG-000-TU, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MLX90316SDC-BCG-000-TU part is unused and in its original packaging.
Return procedure for MLX90316SDC-BCG-000-TU:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MLX90316SDC-BCG-000-TU Tags

-
TLV493DA1B6HTSA2
Infineon Technologies
-
EVW-AE4001B14
Panasonic Electronic Components

-
3382G-1-103G
Bourns Inc.

-
TLE5501E0001XUMA1
Infineon Technologies

-
HAL830UT-A
TDK-Micronas GmbH

-
TLE5009E1000FUMA1
Infineon Technologies

-
TLE5501E0002XUMA1
Infineon Technologies

-
HAL3725DJ-A
TDK-Micronas GmbH

-
HAL3727DJ-A
TDK-Micronas GmbH
-
HMC1501-TR
Honeywell Aerospace
-
HMC1512-TR
Honeywell Aerospace

-
AAS33001LLEATR-5
Allegro MicroSystems
Tech Hub
Schmitt triggers use separate rising and falling thresholds to stabilize slow or noisy signals. This guide covers hysteresis, 74HC14 and 74HCT14 selection, comparator calculations, RC oscillators and p…
Counterfeit components can hide behind convincing markings and passing basic function tests. This engineering reference covers source traceability, external inspection, X-ray, XRF, electrical testing, …
A practical engineering and sourcing framework covering lifecycle verification, lifetime-buy calculations, replacement qualification, supplier checks and counterfeit-risk controls.
TTL and CMOS logic families differ in thresholds, loading, output drive, power and timing. This engineering guide compares 74HC and 74HCT, calculates noise margins and checks 3.3 V/5 V compatibility.
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…