Melexis Technologies NV MLX90817LXE-DBG-003-SP

Part No.:
MLX90817LXE-DBG-003-SP
Manufacturer:
Melexis Technologies NV
Category:
Pressure Sensors, Transducers
Package:
14-BFDFN Exposed Pad
Datasheet:
AetrixMLX90817LXE-DBG-003-SP.pdf
Description:
SENSOR 14DFN
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:2,772

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

MLX90817LXE-DBG-003-SP from Melexis is an automotive-grade absolute pressure sensor IC with integrated MEMS sensing element, 16-bit microcontroller, analog front end, and ratiometric analog output. It delivers 0.2–5.5 bar full-scale pressure measurement with ±53 mbar total accuracy over –40°C to +150°C, factory calibrated for manifold and turbo manifold air pressure applications in engine control units.

For engineers reviewing the MLX90817LXE-DBG-003-SP datasheet, pinout, applications, or equivalent options, this page provides verified functional architecture, diagnostic capabilities, clamping behavior, filter programmability, and automotive EMC performance data directly traceable to Melexis REV 010 documentation.

Technical Context

The MLX90817LXE-DBG-003-SP implements a DSP-based signal chain: piezoresistive Wheatstone bridge feeds into a chopper-stabilized instrumentation amplifier (programmable gain 4.49–10.6 V/V), followed by differential ADC (16-bit, ±VDDA/2 range) and real-time temperature-compensated linearization using EEPROM-stored coefficients (O0–O3, G0–G3, L0–L1). Its architecture supports both small-signal filtering (SSF) and programmable first-order low-pass filtering (PFLT = 0–9).

It integrates automotive diagnostics including broken-track detection on supply/ground lines, overvoltage/undervoltage monitoring, clamping level programming (0–12.5% and 50–100% Vdd), and internal fault reporting via analog rail-driving behavior. The device operates from 4.5–5.5 V supply with 8.5–10 mA current draw and features overvoltage protection up to +18 V and reverse voltage tolerance down to –14 V.

Key Specifications

ParameterValue and Actual Design Meaning
Pressure Range0.2 to 5.5 bar absolute - maps to full-scale analog output swing
Analog OutputRatiometric 0.5 V to 4.5 V - scales linearly with supply voltage (4.5–5.5 V)
Total Accuracy±53 mbar over –40°C to +150°C - includes initial offset, gain, linearity, and tempco errors
Operating Temp–40°C to +150°C - qualified per AEC-Q100 Grade 0 requirements
Supply Voltage4.5 V to 5.5 V - nominal 5 V with POR thresholds at 3.1–3.9 V (analog), 2.05–2.7 V (digital)
Response Time0.93 ms (90% step response) - measured with PFLT = 0 and SSF disabled
EMC PerformanceBest-in-class automotive EMC - achieved via optimized CMOS layout and integrated protection circuitry

Pinout & Package

MLX90817LXE-DBG-003-SP uses a rugged 4×5 mm DFN14 (14-pin) package with wettable flank terminations for automated optical inspection. Pin 1 is marked with a dot; bottom-view pinout is defined per Melexis documentation.

Pin/TerminalCircuit RoleDesign Meaning
1, 3, 5Test pinFactory test access only - not connected in normal operation
2, 4, 6, 9, 11, 12, 13Not ConnectedNo internal connection - must be left floating or tied to ground per PCB layout guidelines
7Supply input (VDD)Primary power input - accepts 4.5–5.5 V with integrated overvoltage/reverse-voltage protection
8Analog output (VANA)Ratiometric pressure output - drives 4.7 kΩ load with 47–470 nF capacitive load capability
10, 14Ground (GND)Dual ground terminals - reduce impedance and improve noise immunity in high-EMI environments

Key Features

FeatureDesign Value
System-in-Package IntegrationMEMS sensor + analog front end + 16-bit MCU + EEPROM + voltage regulators - eliminates external calibration components and reduces BOM count
Programmable Clamping7-bit low clamp (0–12.5% Vdd) and 9-bit high clamp (50–100% Vdd) - enables fail-safe output limiting for ECU safety monitoring
Diagnostic CoverageBuilt-in broken-track, overvoltage, undervoltage, overpressure, and underpressure detection - reports faults via rail-driven output states
Filter FlexibilityConfigurable Small Signal Filter (SSF) and PFLT (0–9) - allows trade-off between noise suppression (up to 203.8 ms response) and dynamic response (0.93 ms)
Harsh Environment RobustnessBurst pressure rating of 15 bar at room temperature - validated for turbocharged intake manifolds and LPG/CNG injector feedback loops

Applications

Manifold Absolute Pressure (MAP) SensingTurbo Manifold Air Pressure

Use Scenario: Real-time monitoring of intake manifold pressure in gasoline direct injection engines for fuel metering and ignition timing control.

IC Role / Device Role / Timing Role: Primary absolute pressure transducer delivering ratiometric analog output synchronized to ECU sampling clock (200 µs update rate).

Use Value: ±53 mbar accuracy across –40°C to +150°C ensures consistent air-mass calculation despite thermal cycling and vibration stress.

Use Scenario: Feedback sensing of compressed air downstream of turbocharger for boost control and wastegate actuation.

IC Role / Device Role / Timing Role: High-bandwidth pressure node with 0.93 ms response time (PFLT=0) enabling closed-loop boost regulation at >100 Hz.

Use Value: 15 bar burst rating and AEC-Q100 qualification support reliable operation under transient overboost conditions.

LPG/CNG Injector MonitoringEngine Control Unit (ECU) Safety Diagnostics

Use Scenario: Pressure verification upstream of gaseous fuel injectors to confirm proper regulator function and detect leaks or blockages.

IC Role / Device Role / Timing Role: Absolute reference sensor interfacing directly with ECU analog input channel - no external signal conditioning required.

Use Value: Factory-calibrated 0.2–5.5 bar range matches typical LPG/CNG rail pressures; ratiometric output rejects supply ripple common in vehicle electrical systems.

Use Scenario: Integrated safety monitor providing real-time fault status (open-circuit, short-to-battery, short-to-ground) to ISO 26262 ASIL-B compliant ECUs.

IC Role / Device Role / Timing Role: Diagnostic subsystem component - asserts low/high fault bands on analog output when supply or ground disconnects occur.

Use Value: Broken-track diagnostics reduce need for external supervision circuits; clamping levels programmable to match ECU ADC thresholds.

Equivalent & Alternatives

The following parts are listed as comparable options for similar absolute pressure sensing applications.

Alternative PartTechnical DifferenceApplication DifferenceSelection Advice
MPX5700AP700 kPa range (0–7 bar), 0.2–1.0 V output, no integrated MCU or diagnosticsRequires external compensation and signal conditioning; lacks automotive diagnostics and programmable filtersLower-cost option where full AEC-Q100 qualification and self-diagnostics are not required
SSM2200-5.5B0.2–5.5 bar range, 0.5–4.5 V output, but no EEPROM programmability or clamping configurationFixed transfer curve and diagnostic thresholds - cannot adapt to custom ECU ADC ranges or safety logicSuitable for non-safety-critical applications needing basic ratiometric output without field reconfiguration

Compared with MPX5700AP and SSM2200-5.5B, the MLX90817LXE-DBG-003-SP provides higher integration (on-chip DSP, EEPROM, diagnostics), wider temperature range (–40°C to +150°C vs. –40°C to +125°C), and design flexibility through programmable clamping and filtering - critical for ASIL-B-compliant engine management systems.

Availability

MLX90817LXE-DBG-003-SP is available at Aetrix Electronics and suitable for automotive engine control, turbocharger boost management, LPG/CNG fuel system monitoring, and industrial pressure feedback requiring stable component supply across extended temperature and lifetime requirements.

Supply support for MLX90817LXE-DBG-003-SP includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

Melexis is a Belgian semiconductor company specializing in intelligent sensors and driver ICs for automotive and industrial applications, with core expertise in magnetic, pressure, and infrared sensing technologies.

The MLX90817 product line delivers fully integrated, AEC-Q100-qualified absolute pressure sensors targeting engine management, turbocharging, and alternative fuel systems where high accuracy, robust diagnostics, and long-term stability under thermal stress are mandatory.

FAQ

What is the pressure range and output behavior of the MLX90817LXE-DBG-003-SP?

The MLX90817LXE-DBG-003-SP is factory configured for 0.2–5.5 bar absolute pressure measurement with a ratiometric analog output spanning 0.5 V to 4.5 V. This output scales linearly with supply voltage (4.5–5.5 V); at 5 V supply, 0.2 bar yields ~0.5 V and 5.5 bar yields ~4.5 V. The transfer curve is stored in on-chip EEPROM and supports reprogramming for custom calibration.

Does the MLX90817LXE-DBG-003-SP support diagnostic functions required for automotive safety systems?

Yes, the MLX90817LXE-DBG-003-SP includes multiple automotive-grade diagnostics: broken-track detection on supply and ground lines, overvoltage/undervoltage monitoring, overpressure/underpressure flags, and configurable clamping levels. Faults drive the analog output to predefined low or high fault bands, enabling ECU-level safety monitoring without external circuitry - supporting ASIL-B system designs.

Can the MLX90817LXE-DBG-003-SP be reprogrammed in-system for different pressure ranges or output curves?

Yes, the MLX90817LXE-DBG-003-SP supports full in-system reprogramming via its dedicated communication mode (entered by applying 6.2–7.8 V to VDD). All EEPROM parameters - including pressure transfer curve coefficients (O0–O3, G0–G3), clamping levels, filter settings (PFLT, SSF), and diagnostic thresholds - can be updated using Melexis-provided tools and protocols.

What is the response time of the MLX90817LXE-DBG-003-SP under default filter settings?

With default filter settings (PFLT = 0 and SSF disabled), the MLX90817LXE-DBG-003-SP achieves a 90% step response time of 0.93 ms. This value is confirmed in Table 13 of the datasheet and applies to pressure steps within the 0.2–5.5 bar range. Increasing PFLT extends response time up to 203.8 ms (PFLT = 9) for enhanced noise rejection.

Is the MLX90817LXE-DBG-003-SP qualified for automotive use and what package does it use?

Yes, the MLX90817LXE-DBG-003-SP is AEC-Q100 Grade 0 qualified (–40°C to +150°C) and assembled in a 4×5 mm DFN14 package with wettable flanks. The package supports automated optical inspection and is rated for burst pressure up to 15 bar at room temperature - meeting stringent requirements for engine bay deployment.

MLX90817LXE-DBG-003-SP Specifications

Product attributes
Attribute value
Manufacturer:
Melexis Technologies NV
Series:
-
Package/Case:
14-BFDFN Exposed Pad
Packaging:
Tray
Product Status:
Active
Applications:
Board Mount
Pressure Type:
Absolute
Operating Pressure:
-
Output Type:
Analog Voltage
Output:
-
Accuracy:
-
Voltage - Supply:
4.5V ~ 5.5V
Port Size:
-
Port Style:
No Port
Features:
Amplified Output, Temperature Compensated
Termination Style:
SMD (SMT) Tab
Maximum Pressure:
-
Operating Temperature:
-40°C ~ 150°C
Grade:
-
Qualification:
-
Mounting Type:
Surface Mount
Supplier Device Package:
14-DFN (4x5)

MLX90817LXE-DBG-003-SP FAQ

1.How can I place an order for MLX90817LXE-DBG-003-SP through Aetrix?

Please submit a Request for Quotation (RFQ) for MLX90817LXE-DBG-003-SP on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for MLX90817LXE-DBG-003-SP reliable?

The price and inventory of MLX90817LXE-DBG-003-SP are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MLX90817LXE-DBG-003-SP is usually 5 days.

3.What payment methods are accepted for MLX90817LXE-DBG-003-SP?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MLX90817LXE-DBG-003-SP transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for MLX90817LXE-DBG-003-SP?

MLX90817LXE-DBG-003-SP orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your MLX90817LXE-DBG-003-SP order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for MLX90817LXE-DBG-003-SP?

For technical support, including MLX90817LXE-DBG-003-SP datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MLX90817LXE-DBG-003-SP requirements.

6.How does Aetrix verify that MLX90817LXE-DBG-003-SP is sourced from the original manufacturer or authorized distributors?

All MLX90817LXE-DBG-003-SP products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MLX90817LXE-DBG-003-SP meets industry standards.

7.What is the process for return or replacement of MLX90817LXE-DBG-003-SP?

All MLX90817LXE-DBG-003-SP units undergo pre-shipment inspection (PSI). If there is an issue with MLX90817LXE-DBG-003-SP, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The MLX90817LXE-DBG-003-SP part is unused and in its original packaging.

Return procedure for MLX90817LXE-DBG-003-SP:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

MLX90817LXE-DBG-003-SP Tags

  • MLX90817LXE-DBG-003-SP
  • MLX90817LXE-DBG-003-SP PDF
  • MLX90817LXE-DBG-003-SP Datasheet
  • MLX90817LXE-DBG-003-SP Specifications
  • MLX90817LXE-DBG-003-SP Images
  • Melexis Technologies NV
  • Melexis Technologies NV MLX90817LXE-DBG-003-SP
  • Buy MLX90817LXE-DBG-003-SP
  • MLX90817LXE-DBG-003-SP Price
  • MLX90817LXE-DBG-003-SP Distributor
  • MLX90817LXE-DBG-003-SP Supplier
  • MLX90817LXE-DBG-003-SP Wholesale
Related Products
DPS368XTSA1
DPS368XTSA1

Infineon Technologies

DPS310XTSA1
DPS310XTSA1

Infineon Technologies

LPS22HHTR
LPS22HHTR

STMicroelectronics

ICP-20100
ICP-20100

TDK InvenSense

ICP-10110
ICP-10110

TDK InvenSense

LPS22DFTR
LPS22DFTR

STMicroelectronics

LPS22HBTR
LPS22HBTR

STMicroelectronics

BMP390
BMP390

Bosch Sensortec

BMP581
BMP581

Bosch Sensortec

BMP384
BMP384

Bosch Sensortec

2511020213301
2511020213301

Würth Elektronik

ILPS22QSTR
ILPS22QSTR

STMicroelectronics

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER