Melexis Technologies NV MLX90818LXE-BBG-017-RE
- Part No.:
- MLX90818LXE-BBG-017-RE
- Manufacturer:
- Melexis Technologies NV
- Category:
- Pressure Sensors, Transducers
- Package:
- 14-BFDFN Exposed Pad
- Datasheet:
-
MLX90818LXE-BBG-017-RE.pdf
- Description:
- SENSOR 58.02PSIA 16BIT 14DFN
- Quantity:
- Payment:

- Shipping:

Inventory:3,537
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MLX90818LXE-BBG-017-RE from Melexis is an automotive-grade absolute pressure sensor with integrated 16-bit microcontroller, SENT digital output, and on-chip NTC temperature interface. It delivers ±0.5% FS pressure accuracy over –40°C to 150°C, 0.1–4 bar full-scale range, and ±1°C compensated NTC temperature data - deployed in turbo manifold air pressure monitoring systems requiring high reliability under harsh thermal and EMC conditions.
For engineers reviewing the MLX90818LXE-BBG-017-RE datasheet, pinout, applications, or equivalent options, this page provides verified technical context, SENT protocol timing constraints, NTC linearization architecture, pressure transfer curve parameters (P1=0.1 bar, P2=4 bar, O1=193 LSB, O2=3896 LSB), and diagnostic configuration options for automotive ECU integration.
Technical Context
The MLX90818LXE-BBG-017-RE implements a piezoresistive MEMS sensing element with Wheatstone bridge output, amplified by a programmable analog front end (Gst1=4.49–10.6 V/V, Gst2=–1.25 or –3.5 V/V, Gst3=1.6–6.4 V/V) and digitized by a 16-bit differential ADC referenced to VDDA/2. Its DSP-based compensation engine applies third-order temperature-dependent gain/offset correction and optional pressure linearization using EEPROM-stored coefficients (O0–O3, G0–G3, L0–L1).
Digital functionality centers on a 16-bit microcontroller executing SENT J2716-compliant frame generation (fast channel for pressure, slow channel for NTC temperature), dual-stage filtering (PFLT programmable 0–9, SSF enable/disable), and comprehensive diagnostics including overvoltage, reverse voltage, broken-wire, and clamping detection - all configurable via EEPROM programming through the supply line.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Pressure Range | 0.1 to 4 bar absolute - defines calibrated operating span for turbo manifold applications with 3.9 bar burst margin. |
| Pressure Accuracy | ±0.5% FS (±20 mBar) at center temperature, ±0.75% FS at extended range - ensures stable ECU air mass calculation across life cycle. |
| NTC Temperature Accuracy | ±1°C at center range (–40°C to 125°C), ±2°C extended (–55°C to 200°C) - enables precise intake air density correction. |
| Output Interface | SENT J2716 compliant - delivers pressure on fast channel, NTC temperature on slow channel, with CRC and diagnostic flags. |
| Operating Temperature | –40°C to +150°C - qualified for under-hood placement without external thermal shielding. |
| Supply Voltage | 4.5 V to 5.5 V nominal - includes overvoltage protection up to 18 V and reverse voltage tolerance to –18 V. |
| Package | DFN14 (4 mm × 5 mm, 0.5 mm pitch) - surface-mount ruggedized housing with exposed thermal pad for PCB heat dissipation. |
Pinout & Package
MLX90818LXE-BBG-017-RE uses a 14-pin DFN package (4×5 mm, 0.5 mm pitch) with wettable flanks and exposed thermal pad. Pin 1 is marked by laser etching; bottom-view orientation places Pin 1 at top-left corner.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 | Test pin | Factory test access; not connected in normal operation. |
| 3 | SENT output | Open-drain SENT signal output with slew-rate control; requires external 10–55 kΩ pull-up to Vdd. |
| 7 | Supply input | Main power input (4.5–5.5 V); decoupled with 100 nF capacitor per datasheet layout guidelines. |
| 8, 12 | NTC input | Differential analog interface for external NTC thermistor; supports resistor divider biasing and 0–3.5 V input range. |
| 10, 14 | Ground | Power and analog ground reference; both pins must be connected to low-impedance PCB ground plane. |
Key Features
| Feature | Design Value |
|---|---|
| System-in-package integration | MEMS sensor, analog front end, 16-bit microcontroller, SENT driver, voltage regulators, and diagnostics logic - eliminates external signal conditioning and reduces BOM count. |
| Programmable SENT configuration | Configurable fast/slow channel mapping, CRC type, pause pulse, and frame rate - enables seamless integration into diverse ECU architectures. |
| Two-stage digital filtering | PFLT (0–9) and SSF (enable/disable) allow independent optimization of response time (3–346 SENT frames) and noise (1–41 LSB pk-pk) - supports both transient manifold pressure tracking and steady-state accuracy. |
| Automotive diagnostics suite | Real-time detection of overvoltage, reverse voltage, open-circuit NTC, supply undervoltage, and pressure out-of-range - meets ISO 26262 ASIL-B readiness requirements. |
| Factory-calibrated transfer curve | EEPROM-stored P1=0.1 bar / P2=4 bar, O1=193 LSB / O2=3896 LSB, LCL=1 LSB / HCL=4088 LSB - eliminates field calibration and ensures drop-in replacement capability. |
Applications
| Manifold Absolute Pressure (MAP) Sensing | Turbocharger Boost Control |
|---|---|
Use Scenario: Real-time measurement of intake manifold pressure in gasoline direct injection engines during transient throttle events and wide-open throttle conditions. IC Role / Device Role / Timing Role: Primary absolute pressure transducer delivering SENT-encoded pressure data every 3–346 frames (adjustable) to ECU for air mass calculation and fuel trim. Use Value: ±0.5% FS accuracy and 150°C operation ensure consistent volumetric efficiency modeling across engine life without recalibration. | Use Scenario: Closed-loop feedback for variable geometry turbocharger (VGT) actuator control under high-boost, high-temperature exhaust conditions. IC Role / Device Role / Timing Role: High-reliability pressure sensor with integrated NTC providing simultaneous boost pressure and intake air temperature to turbo control algorithm. Use Value: Co-located pressure and temperature sensing eliminates inter-channel timing skew and improves transient boost response accuracy by >15% versus discrete solutions. |
| Engine Start-Stop System Monitoring | On-Board Diagnostics (OBD-II) |
Use Scenario: Detection of abnormal vacuum decay during engine-off periods to validate intake system integrity in start-stop vehicles. IC Role / Device Role / Timing Role: Low-power pressure monitor with programmable wake-up thresholds and diagnostic flagging via SENT slow channel. Use Value: Built-in clamping (1–4088 LSB) and fault reporting enable robust leak detection without additional comparator circuitry. | Use Scenario: Compliance with SAE J1979 OBD-II Mode 06 pressure-related PID reporting for emissions certification and dealer-level diagnostics. IC Role / Device Role / Timing Role: SENT-output sensor with standardized fast/slow channel structure and diagnostic bit encoding per J2716 Annex A. Use Value: Native SENT compliance eliminates protocol translation hardware and reduces ECU firmware complexity for regulatory reporting. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar absolute pressure sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MLX90818LXE-BBG-016-RE | Same package and architecture; 0.1–3 bar range, identical NTC interface and SENT format. | Optimized for naturally aspirated engines with lower peak boost; reduced full-scale pressure headroom. | Select when maximum pressure does not exceed 3 bar and cost-sensitive calibration is prioritized. |
| MPX5700AC6U | Analog output (ratiometric 0.2–4.8 V), no integrated microcontroller or SENT; requires external ADC and signal conditioning. | Lacks on-chip temperature compensation, diagnostics, and programmable filtering - increases system design effort. | Choose only if legacy analog interface is mandated and ECU has spare ADC resources and processing bandwidth. |
Compared with MLX90818LXE-BBG-016-RE, the MLX90818LXE-BBG-017-RE extends full-scale pressure range by 33% while retaining identical accuracy, NTC performance, and diagnostic features; versus MPX5700AC6U, it replaces three external components (ADC, regulator, microcontroller) with single-chip SENT output and embedded calibration - reducing PCB area by >40% and qualification effort.
Availability
MLX90818LXE-BBG-017-RE is available at Aetrix Electronics and suitable for turbocharged engine control units, manifold pressure monitoring systems, and automotive OBD-II diagnostic modules requiring stable component supply across extended temperature and harsh media environments.
Supply support for MLX90818LXE-BBG-017-RE includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Melexis is a Belgian semiconductor company specializing in magnetic, infrared, and pressure sensors for automotive and industrial markets, with ISO/TS 16949-certified manufacturing and AEC-Q100 qualification expertise.
The MLX90818 product line was designed specifically for high-accuracy, high-temperature absolute pressure measurement in engine management systems - integrating MEMS, signal conditioning, and SENT communication to replace multi-chip analog solutions.
FAQ
What is the calibrated pressure range of the MLX90818LXE-BBG-017-RE?
The MLX90818LXE-BBG-017-RE is factory calibrated for a 0.1 to 4 bar absolute pressure range, with output spanning 193 to 3896 LSB in SENT format. This range supports turbocharged gasoline and diesel engines where peak manifold pressure exceeds 3 bar. The device maintains ±0.5% FS accuracy across its full scale and operates reliably up to 150°C ambient.
Does the MLX90818LXE-BBG-017-RE support external NTC thermistors?
Yes, the MLX90818LXE-BBG-017-RE includes dedicated NTC input pins (8 and 12) and performs full 16-bit digitization, EEPROM-based linearization, and ±1°C compensated temperature output via SENT slow channel. It is pre-calibrated for standard NTCs matching Table 12 coefficients; non-standard NTCs require custom EEPROM programming via Melexis tools.
How is SENT communication configured on the MLX90818LXE-BBG-017-RE?
The MLX90818LXE-BBG-017-RE implements SAE J2716-compliant SENT output with pressure on Fast Channel and NTC temperature on Slow Channel. Frame rate, pause pulse, CRC type, and channel assignment are stored in EEPROM and can be reprogrammed via supply-line communication - no additional interface lines required beyond Vdd, GND, and SENT output.
What diagnostic functions are built into the MLX90818LXE-BBG-017-RE?
The MLX90818LXE-BBG-017-RE integrates overvoltage (up to 18 V), reverse voltage (down to –18 V), supply undervoltage, open-circuit NTC, and pressure out-of-range diagnostics. Diagnostic status is reported via SENT message bits and can trigger configurable clamping or error frames - enabling ASIL-B–compliant fault handling without external supervision circuitry.
Can the MLX90818LXE-BBG-017-RE be reprogrammed in-system?
Yes, the MLX90818LXE-BBG-017-RE supports in-system EEPROM programming through its supply pin (Vdd) using Melexis' proprietary communication protocol. This allows field updates of calibration coefficients, filter settings (PFLT/SSF), SENT configuration, and diagnostic thresholds - eliminating the need for socketed programming or post-assembly calibration fixtures.
MLX90818LXE-BBG-017-RE Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Melexis Technologies NV
- Series:
- Triaxis®
- Package/Case:
- 14-BFDFN Exposed Pad
- Packaging:
- Tape & Reel (TR)
- Product Status:
- Active
- Applications:
- -
- Pressure Type:
- Absolute
- Operating Pressure:
- 1.45PSI ~ 58.02PSI (10kPa ~ 400kPa)
- Output Type:
- SENT
- Output:
- 16 b
- Accuracy:
- ±0.5%
- Voltage - Supply:
- 4.5V ~ 5.5V
- Port Size:
- -
- Port Style:
- No Port
- Features:
- Temperature Compensated
- Termination Style:
- SMD (SMT) Tab
- Maximum Pressure:
- -
- Operating Temperature:
- -40°C ~ 150°C
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- 14-DFN (4x5)
MLX90818LXE-BBG-017-RE FAQ
1.How can I place an order for MLX90818LXE-BBG-017-RE through Aetrix?
Please submit a Request for Quotation (RFQ) for MLX90818LXE-BBG-017-RE on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MLX90818LXE-BBG-017-RE reliable?
The price and inventory of MLX90818LXE-BBG-017-RE are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MLX90818LXE-BBG-017-RE is usually 5 days.
3.What payment methods are accepted for MLX90818LXE-BBG-017-RE?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MLX90818LXE-BBG-017-RE transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MLX90818LXE-BBG-017-RE?
MLX90818LXE-BBG-017-RE orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MLX90818LXE-BBG-017-RE order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MLX90818LXE-BBG-017-RE?
For technical support, including MLX90818LXE-BBG-017-RE datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MLX90818LXE-BBG-017-RE requirements.
6.How does Aetrix verify that MLX90818LXE-BBG-017-RE is sourced from the original manufacturer or authorized distributors?
All MLX90818LXE-BBG-017-RE products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MLX90818LXE-BBG-017-RE meets industry standards.
7.What is the process for return or replacement of MLX90818LXE-BBG-017-RE?
All MLX90818LXE-BBG-017-RE units undergo pre-shipment inspection (PSI). If there is an issue with MLX90818LXE-BBG-017-RE, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MLX90818LXE-BBG-017-RE part is unused and in its original packaging.
Return procedure for MLX90818LXE-BBG-017-RE:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MLX90818LXE-BBG-017-RE Tags

-
DPS368XTSA1
Infineon Technologies

-
DPS310XTSA1
Infineon Technologies

-
LPS22HHTR
STMicroelectronics

-
ICP-20100
TDK InvenSense

-
ICP-10110
TDK InvenSense

-
LPS22DFTR
STMicroelectronics

-
LPS22HBTR
STMicroelectronics

-
BMP390
Bosch Sensortec

-
BMP581
Bosch Sensortec

-
BMP384
Bosch Sensortec

-
2511020213301
Würth Elektronik

-
ILPS22QSTR
STMicroelectronics
Tech Hub
Comparator circuit design covering voltage thresholds, input limits, open-collector outputs, LM393 wiring, op-amp differences, hysteresis, timing, window detection and practical fault diagnosis.
Schmitt triggers use separate rising and falling thresholds to stabilize slow or noisy signals. This guide covers hysteresis, 74HC14 and 74HCT14 selection, comparator calculations, RC oscillators and p…
Counterfeit components can hide behind convincing markings and passing basic function tests. This engineering reference covers source traceability, external inspection, X-ray, XRF, electrical testing, …
A practical engineering and sourcing framework covering lifecycle verification, lifetime-buy calculations, replacement qualification, supplier checks and counterfeit-risk controls.
TTL and CMOS logic families differ in thresholds, loading, output drive, power and timing. This engineering guide compares 74HC and 74HCT, calculates noise margins and checks 3.3 V/5 V compatibility.
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …