Melexis Technologies NV MLX90819LUF-EBB-000-WB
- Part No.:
- MLX90819LUF-EBB-000-WB
- Manufacturer:
- Melexis Technologies NV
- Category:
- Pressure Sensors, Transducers
- Package:
- Die
- Datasheet:
-
MLX90819LUF-EBB-000-WB.pdf
- Description:
- RELATIVE INTEGRATED PRESSURE SEN
- Quantity:
- Payment:

- Shipping:

Inventory:4,083
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MLX90819LUF-EBB-000-WB from Melexis is a fully integrated relative pressure sensor die delivering ratiometric analog or SENT digital output, designed for 30–50 bar mid-pressure automotive applications including engine oil and fuel line monitoring. It features a piezoresistive MEMS sensing element, 16-bit microcontroller-based DSP compensation, glass pedestal mounting for back-side exposure, and operates across −40°C to +150°C.
For engineers reviewing the MLX90819LUF-EBB-000-WB datasheet, pinout, applications, or equivalent options, this page provides verified functional roles, validated bond pad mapping, calibrated pressure accuracy (±0.2% FSO non-linearity), diagnostic capabilities (clamping, broken track, over/under-pressure), and wafer-level packaging details for bare-die integration.
Technical Context
The MLX90819LUF-EBB-000-WB implements a silicon piezoresistive diaphragm with on-chip temperature sensing, 16-bit ADC, and DSP-based real-time gain/offset compensation across temperature. Its architecture supports programmable filter settings (SSF=1, PFLT=0 default), pressure linearization, and clamping thresholds with 8-bit (low) and 9-bit (high) resolution.
It delivers dual-output capability: analog output (ratiometric, 0–5 V, ±0.2% VDD ratiometricity error) and SENT-compliant digital output (SAE J2716 Jan 2010), both with independent diagnostics logic, reverse polarity protection (−14 V), and overvoltage tolerance (+18 V). The die integrates voltage regulators, EEPROM for configuration storage, and active broken-track detection.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Pressure Range | 30–50 bar full-scale range (EBB option); enables direct use in high-pressure fuel and transmission oil systems without external scaling. |
| Accuracy (Non-Linearity) | ±0.2% FSO at room temperature (30/50 bar calibration points); ensures stable pressure reporting under dynamic engine load conditions. |
| Operating Temp | −40°C to +150°C; qualified beyond AEC-Q100 Grade 0, supporting under-hood placement in modern ICE and hybrid powertrains. |
| Output Options | Ratiometric analog (0–5 V) and SENT digital (single-edge nibble transmission); allows OEMs to select interface based on ECU architecture and noise immunity requirements. |
| Response Time | Analog: 1 ms (10–90%); SENT: 3–4 frames (3 µs tick); meets fast-cycling demand of real-time oil pressure monitoring during cold start and gear shifts. |
| EMC Robustness | Best-in-class automotive EMC performance per optimized CMOS layout and integrated regulator/filtering; reduces need for external shielding in compact modules. |
| Burst Pressure | 140 bar (EBB); exceeds ISO 16750-2 mechanical stress limits for fuel rail and high-pressure oil applications. |
Pinout & Package
MLX90819LUF-EBB-000-WB is supplied as a bare die on sawn wafer (UF package), mounted on a glass pedestal for back-side pressure exposure. Die dimensions are 2.555 mm × 2.555 mm (±0.05 mm), with membrane centered at (0,0) and scribe lane included. Wafer map (WB packing form) identifies functional dies for customer assembly.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| VDD | Supply input | 5 V nominal supply (4.5–5.5 V); includes reverse polarity and overvoltage protection (−14 V / +18 V). |
| GND | Ground reference | Primary ground return for analog/digital domains; requires low-inductance connection to minimize noise coupling. |
| OUT | Analog output | Ratiometric 0–5 V output (VDD-referenced); requires ≤4.7 kΩ resistive load and ≤470 nF capacitive load for stability. |
| TX | SENT digital output | Open-drain SENT signal compliant with SAE J2716; requires 2.2 nF capacitive load and pull-up to VDD. |
| TEST | Factory test input | No-connect in application; used only during wafer-level testing and calibration. |
| SN / SP | Reserved outputs | No-connect; not intended for system use-leave unconnected per datasheet guidance. |
Key Features
| Feature | Design Value |
|---|---|
| Fully integrated MEMS + DSP architecture | Eliminates need for external signal conditioning ICs or microcontrollers-reduces BOM count and PCB area in pressure-sensing modules. |
| Programmable diagnostics | Configurable clamping levels, broken-track detection, and over/under-pressure alerts stored in EEPROM-enables OEM-specific fault response behavior. |
| Glass pedestal mounting | Enables robust back-side exposed configuration compatible with aggressive automotive fluids (oil, fuel, refrigerant) without encapsulation compromise. |
| Automotive-grade EMC performance | Validated against ISO 11452 and CISPR 25; minimizes filtering components and layout iterations in ECU-integrated or standalone sensor designs. |
| Dual-output flexibility | Single die supports analog (legacy ECU compatibility) and SENT (modern high-speed diagnostics) interfaces-simplifies platform reuse across vehicle generations. |
Applications
| Engine Oil Pressure Monitoring | Automatic Transmission Fluid Pressure |
|---|---|
|
Use Scenario: Real-time oil pressure measurement in gasoline and diesel engine lubrication circuits during cold start, idle, and wide-open throttle. IC Role / Device Role / Timing Role: Primary pressure transducer providing analog or SENT feedback to engine control unit for oil starvation warning and adaptive valve timing control. Use Value: ±0.2% FSO accuracy and 1 ms analog response enable precise low-pressure detection (<5 bar) at startup while surviving 140 bar burst events. |
Use Scenario: Closed-loop hydraulic pressure sensing in planetary gearset control circuits of 8- and 10-speed automatic transmissions. IC Role / Device Role / Timing Role: High-stability relative pressure sensor feeding SENT data to TCU for shift timing optimization and clutch engagement verification. Use Value: Glass pedestal construction resists ATF degradation; 30–50 bar range matches line pressure specifications; SENT output supports deterministic diagnostics per UDS. |
| Fuel Rail Pressure Sensing | Industrial Hydraulic Monitoring |
|
Use Scenario: Direct-mount pressure monitoring in high-pressure gasoline direct injection (GDI) and diesel common rail systems (up to 50 bar). IC Role / Device Role / Timing Role: Ratiometric analog output feeds fuel pump controller; SENT output provides redundancy and fault logging to body domain controller. Use Value: Burst rating of 140 bar exceeds ISO 16750-2 requirements; −40°C to +150°C operation supports under-hood placement near injectors. |
Use Scenario: Compact, media-isolated pressure monitoring in industrial hydraulic valves and mobile equipment actuators operating in harsh ambient environments. IC Role / Device Role / Timing Role: Bare-die integration into custom housings with O-ring or welded seals; analog output interfaces with PLC analog inputs; SENT supports predictive maintenance gateways. Use Value: Wafer-level delivery (WB) enables cost-effective high-volume assembly; programmable diagnostics reduce field failure root-cause analysis time. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar relative pressure sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MLX90821LUF-EBB-000-WB | Same die architecture but with enhanced EMC filtering and extended SENT protocol support (J2716 Rev 2016); higher production test coverage. | Targeted for next-gen ADAS-integrated powertrain ECUs requiring stricter CISPR 25 Class 5 immunity. | Select when upgrading from MLX90819LUF-EBB-000-WB for new designs needing updated SENT compliance and tighter EMC margin. |
| MPX5700AC6U | Analog-only output (no SENT); 0–700 kPa range (0–7 bar); no integrated diagnostics or EEPROM; requires external ADC and microcontroller for compensation. | Suitable for cost-sensitive, non-automotive industrial applications where digital diagnostics and high-temperature operation are not required. | Choose only for legacy analog-only systems with <7 bar range and no requirement for AEC-Q100 qualification or embedded diagnostics. |
Compared with MLX90819LUF-EBB-000-WB, MLX90821LUF-EBB-000-WB offers improved electromagnetic resilience and updated SENT compliance for future-proofing, while MPX5700AC6U provides lower-cost analog sensing at reduced pressure range and without automotive qualification or built-in intelligence.
Availability
MLX90819LUF-EBB-000-WB is available at Aetrix Electronics and suitable for engine oil pressure monitoring, automatic transmission fluid control, and fuel rail sensing requiring stable component supply, wafer-level integration flexibility, and AEC-Q100-compliant performance.
Supply support for MLX90819LUF-EBB-000-WB includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Melexis is a Belgian semiconductor company specializing in magnetic, infrared, and pressure sensors for automotive and industrial markets, with ISO/TS 16949 and ISO 14001 certification.
The MLX90819LUF-EBB-000-WB belongs to Melexis' integrated pressure sensor product line, engineered specifically for high-accuracy, high-EMC, back-side exposed automotive pressure measurement in harsh under-hood environments.
FAQ
What is the pressure range calibrated for MLX90819LUF-EBB-000-WB?
The MLX90819LUF-EBB-000-WB is factory-calibrated for a 30–50 bar full-scale pressure range (Option Code EBB), with non-linearity error specified at ±0.2% FSO at room temperature using two-point calibration (30 bar and 50 bar). This range is optimized for high-pressure automotive oil and fuel systems where precision and burst tolerance are critical. MLX90819LUF-EBB-000-WB does not support reprogramming to alternate spans in the field.
Does MLX90819LUF-EBB-000-WB support both analog and SENT outputs simultaneously?
No-MLX90819LUF-EBB-000-WB supports either analog output (via OUT pin) or SENT output (via TX pin), but not both concurrently. The output mode is selected at power-up by internal configuration stored in EEPROM; users must choose one interface per application design. Both outputs share the same pressure measurement path and compensation algorithms, ensuring consistent accuracy regardless of selected mode. MLX90819LUF-EBB-000-WB requires no external mode-select circuitry.
What packaging form does MLX90819LUF-EBB-000-WB ship in?
MLX90819LUF-EBB-000-WB ships as a bare die on fully tested wafers in wafer box (WB) packaging, with "UF" indicating sawn wafer on foil. Each wafer includes an electronic wafer map identifying functional dies. The die measures 2.555 mm × 2.555 mm (±0.05 mm) and mounts on a glass pedestal for back-side pressure exposure-no leadframe, molding compound, or standard IC package is included. MLX90819LUF-EBB-000-WB is intended for die-bonding into custom sensor housings.
How are diagnostics configured on MLX90819LUF-EBB-000-WB?
Diagnostics-including clamping levels, broken-track detection, over/under-pressure flags, and supply monitoring-are configured via EEPROM programming using Melexis' proprietary calibration tools during wafer probe or final test. Default settings are preloaded; users can adjust clamping thresholds (8-bit low / 9-bit high resolution), enable/disable specific diagnostics, and set filter parameters (SSF, PFLT). MLX90819LUF-EBB-000-WB does not support runtime reconfiguration via SENT or analog interface.
Is MLX90819LUF-EBB-000-WB qualified to AEC-Q100?
Yes-MLX90819LUF-EBB-000-WB is qualified beyond AEC-Q100 Grade 0 (−40°C to +150°C), with additional stress testing including extended temperature cycling, high-acceleration mechanical shock, and rigorous EMC validation per ISO 11452 and CISPR 25. Its qualification covers the full die, glass pedestal, and bond pad structure. MLX90819LUF-EBB-000-WB is approved for safety-critical powertrain applications including engine oil and transmission pressure monitoring.
MLX90819LUF-EBB-000-WB Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Melexis Technologies NV
- Series:
- -
- Package/Case:
- Die
- Packaging:
- Bulk
- Product Status:
- Active
- Applications:
- Board Mount
- Pressure Type:
- -
- Operating Pressure:
- 435.11PSI ~ 725.19PSI (3000kPa ~ 5000kPa)
- Output Type:
- Analog, SENT
- Output:
- -
- Accuracy:
- ±2.5%
- Voltage - Supply:
- 4.5V ~ 5.5V
- Port Size:
- -
- Port Style:
- No Port
- Features:
- Temperature Compensated
- Termination Style:
- -
- Maximum Pressure:
- 1522.9PSI (10500kPa)
- Operating Temperature:
- -40°C ~ 150°C
- Grade:
- Automotive
- Qualification:
- AEC-Q100
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- Die
MLX90819LUF-EBB-000-WB FAQ
1.How can I place an order for MLX90819LUF-EBB-000-WB through Aetrix?
Please submit a Request for Quotation (RFQ) for MLX90819LUF-EBB-000-WB on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MLX90819LUF-EBB-000-WB reliable?
The price and inventory of MLX90819LUF-EBB-000-WB are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MLX90819LUF-EBB-000-WB is usually 5 days.
3.What payment methods are accepted for MLX90819LUF-EBB-000-WB?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MLX90819LUF-EBB-000-WB transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MLX90819LUF-EBB-000-WB?
MLX90819LUF-EBB-000-WB orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MLX90819LUF-EBB-000-WB order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MLX90819LUF-EBB-000-WB?
For technical support, including MLX90819LUF-EBB-000-WB datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MLX90819LUF-EBB-000-WB requirements.
6.How does Aetrix verify that MLX90819LUF-EBB-000-WB is sourced from the original manufacturer or authorized distributors?
All MLX90819LUF-EBB-000-WB products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MLX90819LUF-EBB-000-WB meets industry standards.
7.What is the process for return or replacement of MLX90819LUF-EBB-000-WB?
All MLX90819LUF-EBB-000-WB units undergo pre-shipment inspection (PSI). If there is an issue with MLX90819LUF-EBB-000-WB, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MLX90819LUF-EBB-000-WB part is unused and in its original packaging.
Return procedure for MLX90819LUF-EBB-000-WB:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MLX90819LUF-EBB-000-WB Tags

-
DPS368XTSA1
Infineon Technologies

-
DPS310XTSA1
Infineon Technologies

-
LPS22HHTR
STMicroelectronics

-
ICP-20100
TDK InvenSense

-
ICP-10110
TDK InvenSense

-
LPS22DFTR
STMicroelectronics

-
LPS22HBTR
STMicroelectronics

-
BMP390
Bosch Sensortec

-
BMP581
Bosch Sensortec

-
BMP384
Bosch Sensortec

-
2511020213301
Würth Elektronik

-
ILPS22QSTR
STMicroelectronics
Tech Hub
Comparator circuit design covering voltage thresholds, input limits, open-collector outputs, LM393 wiring, op-amp differences, hysteresis, timing, window detection and practical fault diagnosis.
Schmitt triggers use separate rising and falling thresholds to stabilize slow or noisy signals. This guide covers hysteresis, 74HC14 and 74HCT14 selection, comparator calculations, RC oscillators and p…
Counterfeit components can hide behind convincing markings and passing basic function tests. This engineering reference covers source traceability, external inspection, X-ray, XRF, electrical testing, …
A practical engineering and sourcing framework covering lifecycle verification, lifetime-buy calculations, replacement qualification, supplier checks and counterfeit-risk controls.
TTL and CMOS logic families differ in thresholds, loading, output drive, power and timing. This engineering guide compares 74HC and 74HCT, calculates noise margins and checks 3.3 V/5 V compatibility.
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …