Melexis Technologies NV MLX90820LUF-EBA-000-WB
- Part No.:
- MLX90820LUF-EBA-000-WB
- Manufacturer:
- Melexis Technologies NV
- Category:
- Pressure Sensors, Transducers
- Package:
- Die
- Datasheet:
-
MLX90820LUF-EBA-000-WB.pdf
- Description:
- Sensors
- Quantity:
- Payment:

- Shipping:

Inventory:3,527
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MLX90820LUF-EBA-000-WB from Melexis is an automotive-grade absolute pressure sensor IC delivering ratiometric analog and SENT digital outputs, featuring a 16-bit microcontroller-based DSP architecture, ±0.2%FSO non-linearity (10–35 bar range), -40°C to 150°C operating temperature, and integrated diagnostics for clamping, broken-track, and internal fault detection - deployed in HVAC refrigeration and industrial oil-filled pressure modules.
For engineers reviewing the MLX90820LUF-EBA-000-WB datasheet, pinout, applications, or equivalent options, this page provides verified technical context, bond pad mapping, pressure accuracy specs, diagnostic configuration details, and validated alternatives for mid-pressure sensing in harsh environments.
Technical Context
The MLX90820LUF-EBA-000-WB integrates a piezoresistive silicon diaphragm with on-chip analog front-end, 16-bit microcontroller, DSP-based temperature compensation, and dual-output capability (analog ratiometric and SENT J2716-compliant). Its architecture delivers <1 ms analog response time and 3–4 frame SENT response under default filter settings.
It implements programmable clamping (8-bit low / 9-bit high resolution), EEPROM-protected calibration data, and robust EMC performance enabled by high-density CMOS process and optimized layout - all within a bare die format delivered on sawn wafer with electronic wafer map (WB packing).
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Pressure Range | 10–35 bar full-scale output (EBA-000 option); supports mid-pressure HVAC and industrial oil systems |
| Accuracy (Non-Linearity) | ±0.2%FSO at room temperature with 2-point calibration; enables high-fidelity closed-loop control |
| Output Types | Ratiometric analog (0–5 V) and SENT digital (SAE J2716 Jan 2010 compliant); allows flexible ECU interface selection |
| Operating Temperature | -40°C to +150°C; qualified for under-hood automotive and industrial thermal environments |
| Supply Voltage | 4.5–5.5 V; includes reverse-voltage protection (-14 V @ 150°C for 1 hr) and overvoltage tolerance (+18 V) |
| Diagnostics | Clamping levels, broken-track detection, over/under-pressure alerts, and supply rail monitoring - configurable via EEPROM |
| Response Time | Analog: 1 ms (10–90%); SENT: 3–4 frames (3 µs tick, pause pulse enabled); supports fast transient pressure capture |
Pinout & Package
MLX90820LUF-EBA-000-WB is supplied as a bare die in UF package (sawn wafer on foil), with dimensions 2.555 mm × 2.555 mm ±0.05 mm (excluding scribe lane), membrane centered at (0,0), and bond pads arranged per Melexis die layout.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| VDD | Supply input | Power rail (4.5–5.5 V); includes reverse-voltage and overvoltage protection circuitry |
| GND | Ground reference | Primary ground return path; used for diagnostic rail monitoring and broken-track detection |
| OUT | Analog output | Ratiometric voltage output (0–5 V); requires ≥4.7 kΩ resistive load and ≤470 nF capacitive load |
| TX | SENT digital output | Single-Edge Nibble Transmission signal; requires 2.2 nF capacitive load and CRC network (1.1 nF + 220 Ω + 1.1 nF) |
| TEST | Programming input | Used for EEPROM programming via connector; must be left unconnected in final application |
Key Features
| Feature | Design Value |
|---|---|
| Fully integrated MEMS + AFE + 16-bit MCU + DAC + SENT driver | Eliminates external signal conditioning and microcontroller; reduces BOM count and PCB area |
| Programmable diagnostics (clamping, broken track, fault flags) | Enables OEM-specific safety logic without hardware changes; configured via EEPROM during production |
| Built-in EEPROM with write protection | Secures calibration coefficients and diagnostic thresholds against field corruption or accidental overwrite |
| Robust EMC performance (automotive grade) | Validated for high-noise engine bay and industrial motor drive environments without external shielding |
| Oil charge protection | Ensures long-term stability in direct-contact oil-filled pressure transducer assemblies |
Applications
| HVAC Refrigeration Systems | Industrial Oil-Filled Pressure Modules |
|---|---|
|
Use Scenario: Monitoring refrigerant pressure in commercial chillers and heat pumps across ambient temperatures from -25°C to +60°C. IC Role / Device Role / Timing Role: Absolute pressure transducer providing real-time feedback to compressor control logic and safety shutdown circuits. Use Value: ±0.2%FSO accuracy and -40°C to +150°C operation ensure stable regulation across seasonal load swings and defrost cycles. |
Use Scenario: Sealed oil-isolated pressure sensing in hydraulic test benches and industrial pump monitoring systems. IC Role / Device Role / Timing Role: Core sensing element embedded in stainless-steel housings with oil transmission media. Use Value: Oil charge protection and burst pressure rating of 105 bar prevent drift or failure in high-cycle industrial duty cycles. |
| Automotive Air Conditioning | Off-Highway Equipment Hydraulics |
|
Use Scenario: High-side and low-side pressure monitoring in vehicle A/C loops exposed to under-hood thermal cycling. IC Role / Device Role / Timing Role: SENT-output pressure sensor interfacing directly with HVAC control module via standard automotive bus. Use Value: SENT compliance (J2716) and 150°C rating enable drop-in integration without additional level-shifting or thermal derating. |
Use Scenario: Real-time hydraulic pressure feedback in excavator boom controls and agricultural implement actuators. IC Role / Device Role / Timing Role: Analog ratiometric output feeding into ruggedized analog-to-digital converters in mobile controller units. Use Value: 1 ms analog response time and built-in clamping support rapid pressure surge detection during valve actuation events. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar absolute pressure sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MPX5700A | Analog-only output; no SENT interface; ±1.5%FSO accuracy; 0–700 kPa range (≈0–70 bar) | Lacks programmable diagnostics and automotive-grade EMC hardening; requires external ADC and fault logic | Select when cost-sensitive analog-only designs dominate and diagnostic depth is secondary |
| SSM2018-35 | 35 bar fixed-range analog sensor; ±0.5%FSO accuracy; no microcontroller or EEPROM; TO-92 package | Not wafer-level; lacks SENT output, temperature compensation DSP, or programmable clamping | Select for simple, low-cost replacement where wafer integration and digital diagnostics are unnecessary |
Compared with MPX5700A and SSM2018-35, the MLX90820LUF-EBA-000-WB delivers superior accuracy, dual-output flexibility, on-chip diagnostics, and wafer-level integration - making it optimal for next-generation automotive and industrial pressure modules requiring functional safety awareness and miniaturization.
Availability
MLX90820LUF-EBA-000-WB is available at Aetrix Electronics and suitable for HVAC refrigeration systems, industrial oil-filled pressure modules, and automotive air conditioning applications requiring stable component supply, wafer-level sourcing traceability, and long-lifecycle availability.
Supply support for MLX90820LUF-EBA-000-WB includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Melexis is a Belgian semiconductor company specializing in intelligent sensors and wireless RF solutions for automotive, industrial, and consumer markets, certified to IATF 16949 and ISO 14001 standards.
The MLX90820LUF-EBA-000-WB belongs to Melexis' absolute pressure sensor product line, designed specifically for high-accuracy, high-EMC, wafer-level integration in automotive HVAC, industrial hydraulics, and refrigeration systems.
FAQ
What is the pressure range supported by the MLX90820LUF-EBA-000-WB?
The MLX90820LUF-EBA-000-WB is factory-configured for a 10–35 bar absolute pressure range (EBA-000 option), with proof pressure rated at 70 bar and burst pressure at 105 bar at room temperature. This range targets mid-pressure applications including refrigerant monitoring and industrial hydraulic feedback.
Does the MLX90820LUF-EBA-000-WB support both analog and digital outputs simultaneously?
No - the MLX90820LUF-EBA-000-WB supports either analog ratiometric output (via OUT pin) or SENT digital output (via TX pin), but not both concurrently. The output mode is selected during system design and wiring; both share the same VDD and GND connections and internal calibration data.
How is diagnostic functionality implemented in the MLX90820LUF-EBA-000-WB?
The MLX90820LUF-EBA-000-WB implements diagnostics including clamping level detection, broken-track monitoring, and internal fault flags (over/under-pressure, over/under-voltage). These are programmable via EEPROM and reported through output signal behavior - e.g., driving OUT or TX to rail states upon detected faults.
What packaging form does the MLX90820LUF-EBA-000-WB ship in?
The MLX90820LUF-EBA-000-WB ships as a bare die on fully tested wafers (UF package), with "WB" denoting wafer box packing. Each wafer includes an electronic wafer map to identify functional dies, and the die measures 2.555 mm × 2.555 mm ±0.05 mm excluding scribe lanes.
Is the MLX90820LUF-EBA-000-WB qualified for automotive applications?
Yes - the MLX90820LUF-EBA-000-WB carries L-temperature qualification (-40°C to +150°C), meets automotive EMC requirements, and includes diagnostic features aligned with ASIL-B readiness. It is widely deployed in automotive HVAC and air conditioning systems requiring robust, calibrated pressure feedback.
MLX90820LUF-EBA-000-WB Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Melexis Technologies NV
- Series:
- -
- Package/Case:
- Die
- Packaging:
- Bulk
- Product Status:
- Active
- Applications:
- Board Mount
- Pressure Type:
- Absolute
- Operating Pressure:
- 145.04PSI ~ 507.63PSI (1000kPa ~ 3500kPa)
- Output Type:
- SENT
- Output:
- -
- Accuracy:
- ±2.5%
- Voltage - Supply:
- 4.5V ~ 5.5V
- Port Size:
- -
- Port Style:
- No Port
- Features:
- Temperature Compensated
- Termination Style:
- -
- Maximum Pressure:
- 1015.26PSI (7000kPa)
- Operating Temperature:
- -40°C ~ 150°C
- Grade:
- Automotive
- Qualification:
- AEC-Q100
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- Die
MLX90820LUF-EBA-000-WB FAQ
1.How can I place an order for MLX90820LUF-EBA-000-WB through Aetrix?
Please submit a Request for Quotation (RFQ) for MLX90820LUF-EBA-000-WB on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MLX90820LUF-EBA-000-WB reliable?
The price and inventory of MLX90820LUF-EBA-000-WB are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MLX90820LUF-EBA-000-WB is usually 5 days.
3.What payment methods are accepted for MLX90820LUF-EBA-000-WB?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MLX90820LUF-EBA-000-WB transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MLX90820LUF-EBA-000-WB?
MLX90820LUF-EBA-000-WB orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MLX90820LUF-EBA-000-WB order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MLX90820LUF-EBA-000-WB?
For technical support, including MLX90820LUF-EBA-000-WB datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MLX90820LUF-EBA-000-WB requirements.
6.How does Aetrix verify that MLX90820LUF-EBA-000-WB is sourced from the original manufacturer or authorized distributors?
All MLX90820LUF-EBA-000-WB products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MLX90820LUF-EBA-000-WB meets industry standards.
7.What is the process for return or replacement of MLX90820LUF-EBA-000-WB?
All MLX90820LUF-EBA-000-WB units undergo pre-shipment inspection (PSI). If there is an issue with MLX90820LUF-EBA-000-WB, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MLX90820LUF-EBA-000-WB part is unused and in its original packaging.
Return procedure for MLX90820LUF-EBA-000-WB:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MLX90820LUF-EBA-000-WB Tags

-
DPS368XTSA1
Infineon Technologies

-
DPS310XTSA1
Infineon Technologies

-
LPS22HHTR
STMicroelectronics

-
ICP-20100
TDK InvenSense

-
ICP-10110
TDK InvenSense

-
LPS22DFTR
STMicroelectronics

-
LPS22HBTR
STMicroelectronics

-
BMP390
Bosch Sensortec

-
BMP581
Bosch Sensortec

-
BMP384
Bosch Sensortec

-
2511020213301
Würth Elektronik

-
ILPS22QSTR
STMicroelectronics
Tech Hub
Comparator circuit design covering voltage thresholds, input limits, open-collector outputs, LM393 wiring, op-amp differences, hysteresis, timing, window detection and practical fault diagnosis.
Schmitt triggers use separate rising and falling thresholds to stabilize slow or noisy signals. This guide covers hysteresis, 74HC14 and 74HCT14 selection, comparator calculations, RC oscillators and p…
Counterfeit components can hide behind convincing markings and passing basic function tests. This engineering reference covers source traceability, external inspection, X-ray, XRF, electrical testing, …
A practical engineering and sourcing framework covering lifecycle verification, lifetime-buy calculations, replacement qualification, supplier checks and counterfeit-risk controls.
TTL and CMOS logic families differ in thresholds, loading, output drive, power and timing. This engineering guide compares 74HC and 74HCT, calculates noise margins and checks 3.3 V/5 V compatibility.
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …