Melexis Technologies NV MLX90820LUF-EBB-000-SP
- Part No.:
- MLX90820LUF-EBB-000-SP
- Manufacturer:
- Melexis Technologies NV
- Category:
- Pressure Sensors, Transducers
- Package:
- Die
- Datasheet:
-
MLX90820LUF-EBB-000-SP.pdf
- Description:
- Sensors
- Quantity:
- Payment:

- Shipping:

Inventory:2,512
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MLX90820LUF-EBB-000-SP from Melexis is an automotive-grade absolute pressure sensor IC delivering ratiometric analog and SENT outputs, with 30–50 bar full-scale range, ±0.2% FSO non-linearity at room temperature, and operation from −40°C to +150°C - deployed in engine oil pressure monitoring and industrial hydraulic systems.
For engineers reviewing the MLX90820LUF-EBB-000-SP datasheet, pinout, applications, or equivalent options, key selection criteria include its integrated SENT v2010 compliance, programmable diagnostics (broken track, clamping), 16-bit microcontroller-based compensation, and bare-die UF package for direct die bonding in miniaturized modules.
Technical Context
The MLX90820LUF-EBB-000-SP integrates a piezoresistive silicon diaphragm, analog front-end with coarse offset correction, 16-bit microcontroller-based DSP for temperature-compensated linearization, and dual-output analog back-end (12-bit DAC) plus SENT driver compliant with SAE J2716 Jan 2010. It implements real-time diagnostics including over/under-pressure detection and supply rail fault sensing.
Its architecture supports field-programmable EEPROM settings for clamping thresholds (8-bit low / 9-bit high), filter coefficients (SSF=1, PFLT=0 default), and diagnostic enablement - all accessible via dedicated TEST pad during programming, with built-in EE memory protection and reverse-polarity/overvoltage robustness up to −14 V at 150°C.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Pressure Range | 30–50 bar full-scale output span, calibrated for EBB-000 option - defines usable pressure window without signal saturation. |
| Non-Linearity Error | ±0.2% FSO at room temperature (30/50 bar calibration points) - ensures high fidelity across mid-pressure industrial and automotive use cases. |
| Output Types | Ratiometric analog (OUT pin) and SENT digital (TX pin) - enables dual-mode system integration with legacy analog gauges or modern CAN/Sent networks. |
| Operating Temp | −40°C to +150°C - qualified for under-hood automotive locations and high-temp industrial oil-filled modules. |
| Supply Voltage | 4.5–5.5 V nominal, with reverse voltage tolerance to −14 V at 150°C for 1 hour - eliminates need for external reverse-polarity protection. |
| Response Time | Analog: 1 ms (10–90%); SENT: 3–4 frames (3 µs tick time) - supports fast-cycling hydraulic control and real-time engine management feedback. |
| EMC Robustness | Automotive-grade immunity per ISO 11452 and ISO 7637 - validated for harsh environments without additional shielding or filtering. |
Pinout & Package
MLX90820LUF-EBB-000-SP is supplied as a bare die in UF (saw wafer on foil) format, with dimensions 2.555 mm × 2.555 mm ±0.05 mm (excluding scribe lane). Bond pads are gold-plated aluminum with defined coordinates for wire bonding or flip-chip assembly.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| VDD | Supply input | Primary power rail (4.5–5.5 V); includes integrated reverse-polarity and overvoltage protection up to +18 V / −14 V. |
| GND | Ground reference | System ground return path; internal diagnostics monitor open-circuit conditions via broken-track detection logic. |
| OUT | Analog output | Ratiometric voltage output (0–100% VDD) proportional to pressure; requires ≥4.7 kΩ resistive load and ≤470 nF capacitive load. |
| TX | SENT digital output | Sent protocol output (SAE J2716 v2010 compliant); driven only in SENT mode; requires 2.2 nF capacitive load. |
| TEST | Programming input | Used for EEPROM configuration and firmware update; must be left unconnected in final application. |
| SN / SP | Reserved test pads | No functional connection in production; designated "Do Not Connect" per datasheet Table 3. |
Key Features
| Feature | Design Value |
|---|---|
| Integrated MEMS + AFE + DSP + SENT driver | Single-die solution eliminates external signal conditioning, reducing BOM count and PCB footprint in compact pressure modules. |
| Programmable diagnostics | Configurable clamping levels, broken-track detection, and over/under-pressure alerts stored in protected EEPROM - enables OEM-specific fault response logic. |
| Oil-charge immunity | Robust passivation and layout design prevent performance drift in oil-filled industrial transducers exposed to long-term hydrocarbon contact. |
| High EMC resilience | Optimized CMOS architecture and internal filtering meet automotive EMC requirements without external ferrites or shielding components. |
| 16-bit microcontroller compensation | Real-time temperature and pressure linearization delivers ±0.2% FSO accuracy across −40°C to +150°C - outperforms analog-only sensors in thermal stability. |
Applications
| Engine Oil Pressure Monitoring | HVAC Refrigerant Pressure Control |
|---|---|
|
Use Scenario: Real-time measurement of lubricating oil pressure in ICE engines to trigger low-pressure warnings before mechanical failure. IC Role / Device Role / Timing Role: Absolute pressure sensing element with SENT output synchronized to ECU timing cycles for deterministic diagnostics reporting. Use Value: Enables fail-safe shutdown decisions using programmable clamping and broken-track diagnostics - critical for ASIL-B compliant systems. |
Use Scenario: Closed-loop regulation of refrigerant pressure in commercial HVAC chillers operating across wide ambient temperature ranges. IC Role / Device Role / Timing Role: High-accuracy analog output feeds PID controller; SENT output provides service-mode diagnostics to building management systems. Use Value: ±0.2% FSO linearity and −40°C to +150°C operation ensure stable control across seasonal extremes without recalibration. |
| Industrial Hydraulic System Monitoring | Oil-Filled Industrial Pressure Transducer Modules |
|
Use Scenario: Continuous pressure surveillance in mobile hydraulic equipment (e.g., excavators, loaders) subject to vibration and thermal cycling. IC Role / Device Role / Timing Role: Ratiometric analog output interfaces with legacy PLC analog inputs; SENT output supports predictive maintenance telemetry. Use Value: 1 ms analog response time and robust EMC performance maintain signal integrity in electrically noisy machinery environments. |
Use Scenario: Embedded pressure sensing in hermetically sealed, oil-damped industrial transducers for process instrumentation. IC Role / Device Role / Timing Role: Bare-die UF package bonded directly into oil-filled cavities; protected against long-term oil charge accumulation. Use Value: Eliminates drift caused by dielectric charging in silicone oil - verified through extended life testing in oil-filled modules. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar absolute pressure sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MPX5700AP | Legacy analog-only output (no SENT), wider 0–700 kPa range, no programmable diagnostics or EEPROM. | Lacks digital diagnostics and automotive-grade temperature range (−40°C to +125°C only). | Choose MPX5700AP only for cost-sensitive, non-diagnostic analog-only systems where SENT or extended temp is unnecessary. |
| TDK InvenSense ICP-10125 | I²C digital output only, 10–100 kPa range, lower max temp (−40°C to +85°C), no analog output or oil immunity. | Not rated for oil immersion or automotive under-hood use; limited to consumer/industrial air pressure sensing. | Select ICP-10125 for low-power, I²C-based environmental monitoring - not suitable for hydraulic or engine oil applications. |
Compared with MPX5700AP and ICP-10125, the MLX90820LUF-EBB-000-SP uniquely combines 30–50 bar range, SENT+analog dual output, oil-charge immunity, and −40°C to +150°C operation - making it the only viable choice for automotive oil pressure and industrial oil-filled transducers requiring field-programmable diagnostics.
Availability
MLX90820LUF-EBB-000-SP is available at Aetrix Electronics and suitable for engine oil pressure monitoring, HVAC refrigerant control, and industrial hydraulic system monitoring requiring stable component supply across automotive Tier-1 and industrial OEM production programs.
Supply support for MLX90820LUF-EBB-000-SP includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Melexis is a Belgian fabless semiconductor company specializing in intelligent sensors and driver ICs for automotive and industrial markets, certified to IATF 16949 and ISO 14001.
The MLX90820 product line delivers fully integrated absolute pressure sensing solutions optimized for high-accuracy, high-EMC, and miniaturized oil-immersed modules in automotive and industrial applications.
FAQ
What is the pressure range supported by MLX90820LUF-EBB-000-SP?
The MLX90820LUF-EBB-000-SP is factory-configured for a 30–50 bar absolute pressure range, as specified by the EBB-000 option code. This range is calibrated at 30 bar and 50 bar endpoints, delivering ±0.2% FSO non-linearity at room temperature. It is not user-reconfigurable to other spans without reprogramming EEPROM settings and recalibration.
Does MLX90820LUF-EBB-000-SP support both analog and digital outputs simultaneously?
No - the MLX90820LUF-EBB-000-SP supports either analog (via OUT pin) or SENT (via TX pin) output at any given time, determined by external circuit configuration and EEPROM settings. Both outputs share the same pressure data path but require separate load components: 47 nF for analog mode, 2.2 nF for SENT mode.
How is MLX90820LUF-EBB-000-SP protected against oil contamination in industrial modules?
The MLX90820LUF-EBB-000-SP features proprietary passivation and bond pad layout designed to resist dielectric charging from silicone or mineral oils. Its UF bare-die form allows direct encapsulation in oil-filled cavities without performance degradation over time - validated per Melexis internal oil-immersion reliability testing protocols.
What diagnostic functions are enabled by default on MLX90820LUF-EBB-000-SP?
By default, MLX90820LUF-EBB-000-SP enables broken-track detection, over/under-voltage monitoring, and basic clamping (low/high thresholds set to 3% and 96% VDD). Full diagnostic suite - including over/under-pressure alerts and programmable clamping - requires EEPROM configuration via the TEST pad using Melexis-provided tools.
Is MLX90820LUF-EBB-000-SP supplied in tape-and-reel or wafer form?
MLX90820LUF-EBB-000-SP is supplied as a sawn wafer in a wafer box (WB packing form), with electronic wafer map included. It is not offered in tape-and-reel or molded packages - the UF designation confirms bare-die delivery for customer die-bonding into custom housings or modules.
MLX90820LUF-EBB-000-SP Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Melexis Technologies NV
- Series:
- -
- Package/Case:
- Die
- Packaging:
- Bulk
- Product Status:
- Active
- Applications:
- Board Mount
- Pressure Type:
- Absolute
- Operating Pressure:
- 435.11PSI ~ 725.19PSI (3000kPa ~ 5000kPa)
- Output Type:
- SENT
- Output:
- -
- Accuracy:
- ±2.5%
- Voltage - Supply:
- 4.5V ~ 5.5V
- Port Size:
- -
- Port Style:
- No Port
- Features:
- Temperature Compensated
- Termination Style:
- -
- Maximum Pressure:
- 1522.9PSI (10500kPa)
- Operating Temperature:
- -40°C ~ 150°C
- Grade:
- Automotive
- Qualification:
- AEC-Q100
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- Die
MLX90820LUF-EBB-000-SP FAQ
1.How can I place an order for MLX90820LUF-EBB-000-SP through Aetrix?
Please submit a Request for Quotation (RFQ) for MLX90820LUF-EBB-000-SP on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MLX90820LUF-EBB-000-SP reliable?
The price and inventory of MLX90820LUF-EBB-000-SP are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MLX90820LUF-EBB-000-SP is usually 5 days.
3.What payment methods are accepted for MLX90820LUF-EBB-000-SP?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MLX90820LUF-EBB-000-SP transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MLX90820LUF-EBB-000-SP?
MLX90820LUF-EBB-000-SP orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MLX90820LUF-EBB-000-SP order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MLX90820LUF-EBB-000-SP?
For technical support, including MLX90820LUF-EBB-000-SP datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MLX90820LUF-EBB-000-SP requirements.
6.How does Aetrix verify that MLX90820LUF-EBB-000-SP is sourced from the original manufacturer or authorized distributors?
All MLX90820LUF-EBB-000-SP products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MLX90820LUF-EBB-000-SP meets industry standards.
7.What is the process for return or replacement of MLX90820LUF-EBB-000-SP?
All MLX90820LUF-EBB-000-SP units undergo pre-shipment inspection (PSI). If there is an issue with MLX90820LUF-EBB-000-SP, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MLX90820LUF-EBB-000-SP part is unused and in its original packaging.
Return procedure for MLX90820LUF-EBB-000-SP:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MLX90820LUF-EBB-000-SP Tags

-
DPS368XTSA1
Infineon Technologies

-
DPS310XTSA1
Infineon Technologies

-
LPS22HHTR
STMicroelectronics

-
ICP-20100
TDK InvenSense

-
ICP-10110
TDK InvenSense

-
LPS22DFTR
STMicroelectronics

-
LPS22HBTR
STMicroelectronics

-
BMP390
Bosch Sensortec

-
BMP581
Bosch Sensortec

-
BMP384
Bosch Sensortec

-
2511020213301
Würth Elektronik

-
ILPS22QSTR
STMicroelectronics
Tech Hub
Comparator circuit design covering voltage thresholds, input limits, open-collector outputs, LM393 wiring, op-amp differences, hysteresis, timing, window detection and practical fault diagnosis.
Schmitt triggers use separate rising and falling thresholds to stabilize slow or noisy signals. This guide covers hysteresis, 74HC14 and 74HCT14 selection, comparator calculations, RC oscillators and p…
Counterfeit components can hide behind convincing markings and passing basic function tests. This engineering reference covers source traceability, external inspection, X-ray, XRF, electrical testing, …
A practical engineering and sourcing framework covering lifecycle verification, lifetime-buy calculations, replacement qualification, supplier checks and counterfeit-risk controls.
TTL and CMOS logic families differ in thresholds, loading, output drive, power and timing. This engineering guide compares 74HC and 74HCT, calculates noise margins and checks 3.3 V/5 V compatibility.
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …