Melexis Technologies NV MLX90820LUF-EBB-000-WB
- Part No.:
- MLX90820LUF-EBB-000-WB
- Manufacturer:
- Melexis Technologies NV
- Category:
- Pressure Sensors, Transducers
- Package:
- Die
- Datasheet:
-
MLX90820LUF-EBB-000-WB.pdf
- Description:
- Sensors
- Quantity:
- Payment:

- Shipping:

Inventory:4,155
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MLX90820LUF-EBB-000-WB from Melexis is an automotive-grade absolute pressure sensor IC delivering ratiometric analog and SENT digital outputs, with 30–50 bar full-scale range, ±0.2% FSO non-linearity at room temperature, and operation from −40°C to +150°C. It integrates MEMS sensing element, 16-bit microcontroller, analog front-end/back-end, voltage regulators, and SENT driver on a single die for mid-pressure industrial and HVAC applications.
For engineers reviewing the MLX90820LUF-EBB-000-WB datasheet, pinout, applications, or equivalent options, key selection factors include its programmable clamping diagnostics, built-in EEPROM protection, burst pressure rating of 140 bar, and wafer-level delivery with electronic map for die-level integration into oil-filled modules.
Technical Context
The MLX90820LUF-EBB-000-WB implements a piezoresistive silicon diaphragm with on-chip temperature sensing, followed by a 12-bit DAC-based analog output path and a SAE J2716-compliant SENT transmitter. Its DSP-based compensation uses factory-calibrated coefficients stored in EEPROM to correct offset, gain, and linearity across temperature.
Diagnostics include broken-track detection, over/under-voltage monitoring, over/under-pressure flags, and programmable clamping thresholds (8-bit low / 9-bit high resolution). The device supports both analog mode (OUT pin) and SENT mode (TX pin), with dedicated bond pads and no shared functionality between output paths.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Pressure Range | 30–50 bar full-scale span, calibrated for EBB option code; enables precise monitoring in high-mid pressure hydraulic and refrigerant systems. |
| Accuracy (Non-Linearity) | ±0.2% FSO at room temperature (30/50 bar calibration points); ensures stable measurement without external linearization in embedded control loops. |
| Output Interfaces | Ratiometric analog (0–5 V, 12-bit effective) and SENT digital (SAE J2716 Jan 2010 compliant); supports dual-path redundancy or system-level flexibility. |
| Operating Temperature | −40°C to +150°C ambient; qualified for under-hood automotive and industrial environments without derating. |
| Burst Pressure | 140 bar at room temperature; provides mechanical safety margin for transient overpressure events in oil-filled modules. |
| Supply Current | 7–8 mA typical at 5 V; enables low-power operation in battery-backed or energy-constrained sensor nodes. |
| Response Time | 1 ms (analog), 3–4 SENT frames (≈3–4 µs per frame with pause pulse); suitable for real-time closed-loop pressure regulation. |
Pinout & Package
MLX90820LUF-EBB-000-WB is supplied as bare die on fully tested wafer (package code "UF"), with dimensions 2.555 mm × 2.555 mm ±0.05 mm (excluding scribe lane), membrane centered at (0,0), and bond pad layout optimized for flip-chip or wire-bond assembly into hermetic oil-filled modules.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| VDD | Power supply input | 4.5–5.5 V nominal; includes reverse polarity and overvoltage protection up to −14 V / +18 V. |
| GND | Ground reference | Primary return path for analog and digital circuitry; bonded to substrate for EMC robustness. |
| OUT | Analog output | Ratiometric 0–5 V output (VDD-referenced); active only in analog mode; requires 47 nF load capacitor. |
| TX | SENT digital output | Open-drain SENT signal compliant with SAE J2716; active only in SENT mode; requires 2.2 nF capacitive load. |
| TEST | Factory programming input | Reserved for EEPROM configuration during production; must be left unconnected in end application. |
Key Features
| Feature | Design Value |
|---|---|
| Integrated MEMS + ASIC architecture | Single-die solution eliminates interconnect drift and thermal mismatch between sensor and signal chain - critical for long-term stability in oil-filled modules. |
| Programmable diagnostics | EEPROM-configurable clamping levels, broken-track detection, and fault flagging enable field-tunable safety logic without hardware changes. |
| Automotive EMC robustness | Optimized CMOS layout and internal protection circuits deliver best-in-class immunity per ISO 11452 and ISO 7637 without external filters. |
| Oil charge immunity | Passivated die surface and proprietary encapsulation prevent performance degradation in hydrocarbon-based pressure media. |
| Wafer-level traceability | Electronic wafer map (WB packing form) enables 100% die-level binning, calibration data linkage, and failure analysis traceability. |
Applications
| Refrigeration System Monitoring | HVAC Compressor Control |
|---|---|
|
Use Scenario: Real-time suction/discharge pressure monitoring in variable-speed R410A/R32 refrigeration units to prevent compressor stall and optimize expansion valve timing. IC Role / Device Role / Timing Role: Absolute pressure transducer providing SENT-synchronized readings every 3–4 frames for closed-loop PID control at 100 Hz update rate. Use Value: Enables 0.2% FSO accuracy over −40°C to +150°C without recalibration, reducing field failure rates in outdoor condensing units. |
Use Scenario: High-temperature pressure feedback in rooftop HVAC compressors operating continuously at 130°C ambient with oil-lubricated refrigerant circulation. IC Role / Device Role / Timing Role: Analog ratiometric output (OUT pin) feeds into microcontroller ADC for fast-response overload protection with <1 ms latency. Use Value: Burst pressure rating of 140 bar prevents catastrophic rupture during refrigerant slug events, extending service life beyond 15 years. |
| Industrial Hydraulic Load Sensing | Oil-Filled Pressure Transmitter Module |
|
Use Scenario: Embedded pressure feedback in mobile hydraulic valves for excavator boom control, where vibration and thermal cycling exceed 10⁶ cycles. IC Role / Device Role / Timing Role: Dual-output capability allows SENT for CAN bus telemetry and analog for local safety cutoff - independent signal paths enhance functional safety. Use Value: Built-in broken-track diagnostics detect open-circuit faults in harnesses before actuator misfire, meeting ASIL-B diagnostic coverage requirements. |
Use Scenario: Core sensing element in OEM-designed oil-filled stainless-steel pressure transmitters for chemical process instrumentation. IC Role / Device Role / Timing Role: Bare-die integration (UF package) directly onto ceramic substrate with silicone oil fill; eliminates wire-bond fatigue and interface delamination. Use Value: Oil charge immunity and −40°C to +150°C operation ensure metrological stability in aggressive media (e.g., glycol, mineral oil, synthetic esters). |
Equivalent & Alternatives
The following parts are listed as comparable options for similar absolute pressure sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MPX5700系列 (NXP) | 70 bar analog-only output; no SENT interface; ±2% FSO accuracy; SO-8 packaged IC requiring external signal conditioning. | Lacks integrated diagnostics, EEPROM, and digital output - requires companion MCU for SENT conversion and fault handling. | Choose MPX5700 only if analog-only interface suffices and board space permits discrete signal chain design. |
| TDK InvenSense ICP-10125 | I²C digital output only; 1–2 bar range; ±0.5% FSO; MEMS + ASIC in 2.0 × 2.0 mm LGA; no oil compatibility or automotive temp rating. | Designed for consumer-grade barometric sensing, not industrial oil-filled modules or high-temp hydraulic use. | Select ICP-10125 only for low-pressure, non-oil, non-automotive applications where I²C interface and small footprint are primary drivers. |
Compared with MPX5700 and ICP-10125, the MLX90820LUF-EBB-000-WB uniquely combines 30–50 bar range, SENT+analog dual output, automotive-grade diagnostics, and bare-die oil compatibility - enabling direct integration into high-reliability, high-EMC industrial pressure modules without external components.
Availability
MLX90820LUF-EBB-000-WB is available at Aetrix Electronics and suitable for refrigeration system monitoring, HVAC compressor control, and industrial hydraulic load sensing requiring stable component supply, wafer-level traceability, and long-term calibration retention.
Supply support for MLX90820LUF-EBB-000-WB includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Melexis is a Belgian semiconductor company specializing in magnetic, infrared, and pressure sensors for automotive and industrial markets, certified to IATF 16949 and ISO 14001.
The MLX90820 product line delivers fully integrated absolute pressure sensing solutions targeting oil-filled industrial modules and automotive HVAC systems where miniaturization, EMC robustness, and diagnostic compliance are mandatory.
FAQ
What pressure range does the MLX90820LUF-EBB-000-WB support?
The MLX90820LUF-EBB-000-WB is factory-programmed for a 30–50 bar absolute pressure range (EBB option code), with calibration performed at 30 bar and 50 bar endpoints. Its proof pressure is 105 bar and burst pressure is 140 bar at room temperature - making it suitable for high-stress hydraulic and refrigerant applications where overpressure resilience is critical. This range is fixed per die and cannot be reconfigured in the field.
Does the MLX90820LUF-EBB-000-WB support both analog and SENT outputs simultaneously?
No - the MLX90820LUF-EBB-000-WB operates in either analog mode (using the OUT pin) or SENT mode (using the TX pin), but not both concurrently. The mode is selected via external circuit configuration: connecting OUT to load enables analog output; connecting TX to SENT receiver enables digital output. Internal logic disables the inactive path to minimize power and noise coupling.
How is the MLX90820LUF-EBB-000-WB protected against oil contamination?
The MLX90820LUF-EBB-000-WB features a passivated die surface and proprietary backside sealing that prevents hydrocarbon absorption and electrical charge buildup from mineral oils, synthetic esters, and refrigerant oils. This oil charge immunity is validated per Melexis internal test protocol and enables stable long-term drift performance (<0.2% FSO/year) in oil-filled modules without additional barrier layers.
Can the MLX90820LUF-EBB-000-WB be used without external capacitors?
No - the MLX90820LUF-EBB-000-WB requires two minimum external capacitors: a 47 nF decoupling capacitor on VDD and a 47 nF load capacitor on the OUT pin for analog mode (or 2.2 nF on TX for SENT mode). These are mandatory for stable regulation, noise suppression, and SENT timing compliance per SAE J2716. Omitting them causes output instability and EMC failures.
Is the MLX90820LUF-EBB-000-WB delivered as a packaged IC or bare die?
The MLX90820LUF-EBB-000-WB is delivered as bare die on fully tested wafers (package code "UF") in wafer box (WB) format, accompanied by an electronic wafer map. It is not supplied in molded plastic or ceramic packages. Customers must integrate it using flip-chip or wire-bond assembly into custom housings - typically oil-filled stainless-steel or ceramic pressure modules.
MLX90820LUF-EBB-000-WB Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Melexis Technologies NV
- Series:
- -
- Package/Case:
- Die
- Packaging:
- Bulk
- Product Status:
- Active
- Applications:
- Board Mount
- Pressure Type:
- Absolute
- Operating Pressure:
- 435.11PSI ~ 725.19PSI (3000kPa ~ 5000kPa)
- Output Type:
- SENT
- Output:
- -
- Accuracy:
- ±2.5%
- Voltage - Supply:
- 4.5V ~ 5.5V
- Port Size:
- -
- Port Style:
- No Port
- Features:
- Temperature Compensated
- Termination Style:
- -
- Maximum Pressure:
- 1522.9PSI (10500kPa)
- Operating Temperature:
- -40°C ~ 150°C
- Grade:
- Automotive
- Qualification:
- AEC-Q100
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- Die
MLX90820LUF-EBB-000-WB FAQ
1.How can I place an order for MLX90820LUF-EBB-000-WB through Aetrix?
Please submit a Request for Quotation (RFQ) for MLX90820LUF-EBB-000-WB on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MLX90820LUF-EBB-000-WB reliable?
The price and inventory of MLX90820LUF-EBB-000-WB are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MLX90820LUF-EBB-000-WB is usually 5 days.
3.What payment methods are accepted for MLX90820LUF-EBB-000-WB?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MLX90820LUF-EBB-000-WB transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MLX90820LUF-EBB-000-WB?
MLX90820LUF-EBB-000-WB orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MLX90820LUF-EBB-000-WB order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MLX90820LUF-EBB-000-WB?
For technical support, including MLX90820LUF-EBB-000-WB datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MLX90820LUF-EBB-000-WB requirements.
6.How does Aetrix verify that MLX90820LUF-EBB-000-WB is sourced from the original manufacturer or authorized distributors?
All MLX90820LUF-EBB-000-WB products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MLX90820LUF-EBB-000-WB meets industry standards.
7.What is the process for return or replacement of MLX90820LUF-EBB-000-WB?
All MLX90820LUF-EBB-000-WB units undergo pre-shipment inspection (PSI). If there is an issue with MLX90820LUF-EBB-000-WB, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MLX90820LUF-EBB-000-WB part is unused and in its original packaging.
Return procedure for MLX90820LUF-EBB-000-WB:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MLX90820LUF-EBB-000-WB Tags

-
DPS368XTSA1
Infineon Technologies

-
DPS310XTSA1
Infineon Technologies

-
LPS22HHTR
STMicroelectronics

-
ICP-20100
TDK InvenSense

-
ICP-10110
TDK InvenSense

-
LPS22DFTR
STMicroelectronics

-
LPS22HBTR
STMicroelectronics

-
BMP390
Bosch Sensortec

-
BMP581
Bosch Sensortec

-
BMP384
Bosch Sensortec

-
2511020213301
Würth Elektronik

-
ILPS22QSTR
STMicroelectronics
Tech Hub
Comparator circuit design covering voltage thresholds, input limits, open-collector outputs, LM393 wiring, op-amp differences, hysteresis, timing, window detection and practical fault diagnosis.
Schmitt triggers use separate rising and falling thresholds to stabilize slow or noisy signals. This guide covers hysteresis, 74HC14 and 74HCT14 selection, comparator calculations, RC oscillators and p…
Counterfeit components can hide behind convincing markings and passing basic function tests. This engineering reference covers source traceability, external inspection, X-ray, XRF, electrical testing, …
A practical engineering and sourcing framework covering lifecycle verification, lifetime-buy calculations, replacement qualification, supplier checks and counterfeit-risk controls.
TTL and CMOS logic families differ in thresholds, loading, output drive, power and timing. This engineering guide compares 74HC and 74HCT, calculates noise margins and checks 3.3 V/5 V compatibility.
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …