Melexis Technologies NV MLX90821LXG-DBA-100-SP

Part No.:
MLX90821LXG-DBA-100-SP
Manufacturer:
Melexis Technologies NV
Category:
Pressure Sensors, Transducers
Package:
16-SOIC (0.295", 7.50mm Width) Exposed Pad
Datasheet:
AetrixMLX90821LXG-DBA-100-SP.pdf
Description:
SENSOR 3.77PSID 12BIT 16SOIC
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:4,414

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

MLX90821LXG-DBA-100-SP from Melexis is a factory-calibrated, automotive-grade relative pressure sensor IC delivering digital SENT output (193–3896 LSB) over –0.06 to 0.26 bar range, with ±4.8 mbar total pressure accuracy and integrated diagnostics across –40°C to 150°C. It integrates MEMS sensing element, 16-bit microcontroller, DSP-based compensation, and SENT v4-compliant interface for fuel vapor pressure monitoring in engine control units.

For engineers reviewing the MLX90821LXG-DBA-100-SP datasheet, pinout, applications, or equivalent options, this page delivers verified specifications, functional context, package mapping, real-world use cases, and validated alternative options for automotive pressure sensing design-in.

Technical Context

The MLX90821LXG-DBA-100-SP implements a piezoresistive MEMS sensing element with backside cavity exposure, coupled to a 16-bit differential ADC and DSP-based linearization engine. Its analog front end includes programmable gain instrumentation amplification (Gst1 = 4.49–10.6 V/V), coarse offset DAC, and chopper-stabilized stages enabling sub-millibar resolution.

Digital functionality centers on SENT protocol compliance per SAE J2716 rev 4 (2016), supporting Fast Channel (pressure) and Slow Channel (NTC temperature) transmission. Programmable filters include PFLT (0–9 depth) and SSF, with default PFLT=0 yielding 3 SENT frames response time and 2.2 nF capacitive load tolerance on SENT output.

Key Specifications

Parameter Value and Actual Design Meaning
Pressure Range –0.06 to 0.26 bar relative: supports low-differential fuel vapor and crankcase ventilation monitoring with 0.32 bar full-scale span.
Output Format SENT digital (193–3896 LSB): 12-bit effective resolution, ratiometric to supply, compliant with SAE J2716 rev 4.
Accuracy ±4.8 mbar total pressure error: includes initial, temperature, and long-term drift contributions over –40°C to 150°C.
Operating Temp –40°C to 150°C: qualified for under-hood automotive environments with guaranteed performance and diagnostic coverage.
Supply Voltage 4.5–5.5 V: operates from standard 5 V automotive rail with internal regulators (VDDA = 3.5 V ±9%, Vbrg = 3 V ±9%).
Power-Up Time 1.1 ms to first SENT frame: enables fast system wake-up and synchronization in start-stop engine cycles.
Diagnostic Coverage Built-in clamping, broken-track, over/under-voltage, and over/under-pressure detection: reduces need for external safety monitors.

Pinout & Package

MLX90821LXG-DBA-100-SP uses SOIC16 WB cavity package (XG code) with backside pressure port and exposed die attach pad for thermal and mechanical robustness in harsh media environments.

Pin/Terminal Circuit Role Design Meaning
1, 2, 3, 4, 13, 14, 15, 16 No Connect Unused pins; must be left floating or grounded per layout guidelines-no internal connection.
5, 7 Ground (GND) Dual GND pins reduce impedance and improve EMC immunity; require low-inductance PCB routing.
6 NTC Input Accepts external NTC current output (0–3.5 V range); enables compensated temperature reporting via SENT Slow Channel.
8 Analog Output Not used in DBA-100 variant; configured as high-impedance when SENT mode is active.
9 Supply Input (Vsupply) Primary power input (4.5–5.5 V); requires 47–100 nF decoupling capacitor close to pin.
11 SENT Output Open-drain SENT signal output; requires 10–55 kΩ pull-up to Vdd at receiver per SAE J2716.
10, 12 Test Pins Factory programming and diagnostics access; not intended for end-user circuit connection.

Key Features

Feature Design Value
SENT v4 Digital Interface Enables deterministic, noise-immune communication with ECU over single wire; supports Fast Channel (pressure) and Slow Channel (NTC temp) multiplexing.
Factory-Calibrated Transfer Curve Pre-programmed EEPROM stores pressure-to-LSB mapping (193–3896) and clamping levels (1–4088 LSB), eliminating field calibration effort.
Programmable Diagnostic Thresholds Configurable clamping (7-bit low / 9-bit high), broken-track detection, and fault flagging reduce software overhead in safety-critical systems.
Backside-Exposed MEMS Cavity Enables direct media contact with high resistance to fuel vapors, oil mist, and condensates-critical for crankcase and EVAP applications.
Automotive EMC Robustness Optimized CMOS architecture and integrated overvoltage (18 V) / reverse voltage (–14 V) protection meet stringent OEM EMC requirements.

Applications

Fuel Vapor Pressure Monitoring Crankcase Ventilation (PCV) Sensing

Use Scenario: Real-time measurement of evaporative emissions system pressure during leak detection (OBD-II EVAP test).

IC Role / Device Role / Timing Role: Primary SENT-output pressure transducer providing calibrated 12-bit pressure data every 10–100 ms to ECU for pressure decay analysis.

Use Value: Enables compliance with EPA Tier 3 and Euro 6d evaporative emission standards using single-chip solution with built-in diagnostics.

Use Scenario: Detection of abnormal crankcase pressure buildup indicating piston ring wear or turbocharger seal failure.

IC Role / Device Role / Timing Role: Relative pressure sensor mounted on PCV line, delivering SENT frames synchronized to engine speed for trend analysis.

Use Value: Supports predictive maintenance by detecting >0.1 bar deviations from baseline, with temperature-compensated accuracy over full engine operating range.

Exhaust Gas Recirculation (EGR) Differential Pressure Aftertreatment Filter Clogging Detection

Use Scenario: Measuring pressure drop across EGR valve to verify flow rate and detect clogging or sticking.

IC Role / Device Role / Timing Role: High-speed SENT interface delivers pressure data with ≤3-frame latency (PFLT=0) for closed-loop EGR control.

Use Value: Improves NOx reduction efficiency by enabling precise EGR valve positioning feedback without analog signal conditioning.

Use Scenario: Monitoring differential pressure across diesel particulate filter (DPF) or gasoline particulate filter (GPF) to trigger regeneration.

IC Role / Device Role / Timing Role: Dual-range capable sensor (via reprogramming) used in filter housing to report pressure delta with ±4.8 mbar repeatability.

Use Value: Extends filter service life by optimizing regeneration timing and reducing unburned hydrocarbon slip during incomplete regen events.

Equivalent & Alternatives

The following parts are listed as comparable options for similar relative pressure sensing applications.

Alternative Part Technical Difference Application Difference Selection Advice
NXP MPXV7025DP Analog ratiometric output only (0.2–4.8 V); no SENT, no NTC interface, no programmable diagnostics; 2.5% FS accuracy over –40°C to 125°C. Limited to non-safety-critical analog systems; requires external ADC and fault monitoring circuitry. Select when cost-sensitive designs accept higher BOM count and reduced diagnostic coverage.
Infineon DPS368 I²C digital output; absolute pressure only (0–126 kPa); ±0.005 kPa accuracy; no automotive qualification or pressure port sealing. Not suitable for relative pressure or harsh-media automotive use; lacks burst pressure rating (3.75 bar) and clamping diagnostics. Select only for cabin or ambient pressure sensing where media exposure and automotive qualification are irrelevant.

Compared with MLX90821LXG-DBA-100-SP, the MPXV7025DP requires external signal conditioning and fault logic, while the DPS368 lacks relative pressure capability, automotive qualification, and media-resistant packaging-making MLX90821LXG-DBA-100-SP the only drop-in solution for SENT-based, media-exposed, safety-aware automotive pressure monitoring.

Availability

MLX90821LXG-DBA-100-SP is available at Aetrix Electronics and suitable for fuel vapor pressure monitoring, crankcase ventilation sensing, and aftertreatment filter clogging detection requiring stable component supply, long-lifecycle support, and AEC-Q100-compliant traceability.

Supply support for MLX90821LXG-DBA-100-SP includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

Melexis is a Belgian semiconductor company specializing in magnetic, pressure, and infrared sensors for automotive and industrial markets, with ISO/TS 16949 certification and deep expertise in MEMS integration.

The MLX90821 product line targets high-reliability automotive pressure sensing, combining MEMS, mixed-signal ASIC, and embedded firmware to replace multi-component analog solutions with single-chip SENT-enabled devices.

FAQ

What output format does the MLX90821LXG-DBA-100-SP use?

The MLX90821LXG-DBA-100-SP delivers a digital SENT output compliant with SAE J2716 rev 4, encoding pressure as 193–3896 LSB over its –0.06 to 0.26 bar range. It does not provide analog output in this variant-pin 8 is high-impedance. The SENT frame includes Fast Channel (12-bit pressure) and optional Slow Channel (NTC temperature), with CRC validation and configurable timing.

Is the MLX90821LXG-DBA-100-SP qualified for automotive use?

Yes, the MLX90821LXG-DBA-100-SP is AEC-Q100 qualified for Grade 0 (–40°C to +150°C), with built-in automotive diagnostics including clamping, broken-track detection, over/under-voltage monitoring, and over/under-pressure flags. Its SOIC16 WB cavity package features backside media exposure and robust sealing suitable for fuel vapor, crankcase oil mist, and exhaust gas environments.

Can the MLX90821LXG-DBA-100-SP measure temperature as well as pressure?

Yes-the MLX90821LXG-DBA-100-SP supports external NTC temperature sensing via pin 6, with compensated ±1°C accurate readings transmitted via SENT Slow Channel. It also reports internal die temperature independently. Both temperature values are factory-calibrated and linearized in the DSP, enabling dual-parameter monitoring without additional components.

What is the pressure accuracy specification for MLX90821LXG-DBA-100-SP?

The MLX90821LXG-DBA-100-SP achieves ±4.8 mbar total pressure accuracy over its full –0.06 to 0.26 bar range and –40°C to 150°C operating temperature. This includes contributions from initial calibration error, temperature-induced drift (Fc = 1, Fe = 1.5), and long-term stability-verified per ISO 26262 ASIL-B readiness documentation and Melexis production test data.

Does MLX90821LXG-DBA-100-SP require external programming or calibration?

No-MLX90821LXG-DBA-100-SP ships fully factory-calibrated with pressure transfer curve, clamping thresholds (1–4088 LSB), and SENT configuration stored in on-chip EEPROM. No external calibration is needed. Programming via the connector is optional and reserved for reconfiguration (e.g., filter settings or diagnostic thresholds), not basic operation.

MLX90821LXG-DBA-100-SP Specifications

Product attributes
Attribute value
Manufacturer:
Melexis Technologies NV
Series:
-
Package/Case:
16-SOIC (0.295", 7.50mm Width) Exposed Pad
Packaging:
Tray
Product Status:
Active
Applications:
Board Mount
Pressure Type:
Differential
Operating Pressure:
-0.87PSI ~ 3.77PSI (-6kPa ~ 26kPa)
Output Type:
SENT
Output:
12 b
Accuracy:
-
Voltage - Supply:
4.5V ~ 5.5V
Port Size:
-
Port Style:
No Port
Features:
Amplified Output, Temperature Compensated
Termination Style:
Gull Wing
Maximum Pressure:
-
Operating Temperature:
-40°C ~ 150°C
Grade:
-
Qualification:
-
Mounting Type:
Surface Mount
Supplier Device Package:
16-SOIC

MLX90821LXG-DBA-100-SP FAQ

1.How can I place an order for MLX90821LXG-DBA-100-SP through Aetrix?

Please submit a Request for Quotation (RFQ) for MLX90821LXG-DBA-100-SP on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for MLX90821LXG-DBA-100-SP reliable?

The price and inventory of MLX90821LXG-DBA-100-SP are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MLX90821LXG-DBA-100-SP is usually 5 days.

3.What payment methods are accepted for MLX90821LXG-DBA-100-SP?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MLX90821LXG-DBA-100-SP transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for MLX90821LXG-DBA-100-SP?

MLX90821LXG-DBA-100-SP orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your MLX90821LXG-DBA-100-SP order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for MLX90821LXG-DBA-100-SP?

For technical support, including MLX90821LXG-DBA-100-SP datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MLX90821LXG-DBA-100-SP requirements.

6.How does Aetrix verify that MLX90821LXG-DBA-100-SP is sourced from the original manufacturer or authorized distributors?

All MLX90821LXG-DBA-100-SP products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MLX90821LXG-DBA-100-SP meets industry standards.

7.What is the process for return or replacement of MLX90821LXG-DBA-100-SP?

All MLX90821LXG-DBA-100-SP units undergo pre-shipment inspection (PSI). If there is an issue with MLX90821LXG-DBA-100-SP, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The MLX90821LXG-DBA-100-SP part is unused and in its original packaging.

Return procedure for MLX90821LXG-DBA-100-SP:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

MLX90821LXG-DBA-100-SP Tags

  • MLX90821LXG-DBA-100-SP
  • MLX90821LXG-DBA-100-SP PDF
  • MLX90821LXG-DBA-100-SP Datasheet
  • MLX90821LXG-DBA-100-SP Specifications
  • MLX90821LXG-DBA-100-SP Images
  • Melexis Technologies NV
  • Melexis Technologies NV MLX90821LXG-DBA-100-SP
  • Buy MLX90821LXG-DBA-100-SP
  • MLX90821LXG-DBA-100-SP Price
  • MLX90821LXG-DBA-100-SP Distributor
  • MLX90821LXG-DBA-100-SP Supplier
  • MLX90821LXG-DBA-100-SP Wholesale
Related Products
DPS368XTSA1
DPS368XTSA1

Infineon Technologies

DPS310XTSA1
DPS310XTSA1

Infineon Technologies

LPS22HHTR
LPS22HHTR

STMicroelectronics

ICP-20100
ICP-20100

TDK InvenSense

ICP-10110
ICP-10110

TDK InvenSense

LPS22DFTR
LPS22DFTR

STMicroelectronics

LPS22HBTR
LPS22HBTR

STMicroelectronics

BMP390
BMP390

Bosch Sensortec

BMP581
BMP581

Bosch Sensortec

BMP384
BMP384

Bosch Sensortec

2511020213301
2511020213301

Würth Elektronik

ILPS22QSTR
ILPS22QSTR

STMicroelectronics

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER