Melexis Technologies NV MLX90823GXP-BAD-306-SP
- Part No.:
- MLX90823GXP-BAD-306-SP
- Manufacturer:
- Melexis Technologies NV
- Category:
- Pressure Sensors, Transducers
- Package:
- 4-SIP Module
- Datasheet:
-
MLX90823GXP-BAD-306-SP.pdf
- Description:
- RELATIVE PRESSURE SENSOR WITH AN
- Quantity:
- Payment:

- Shipping:

Inventory:3,101
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MLX90823GXP-BAD-306-SP from Melexis is a PCB-less, factory-calibrated relative pressure sensor with analog output, designed for automotive crankcase ventilation and vacuum monitoring. It delivers 0 to −1.0 bar pressure range, ±0.5% full-scale lifetime accuracy, ratiometric 0.5–4.5 V output, and operates from −40°C to 160°C. Its SMP7 package integrates MEMS, interface IC, and passive components for direct glue-mounting in harsh media environments.
For engineers reviewing the MLX90823GXP-BAD-306-SP datasheet, pinout, applications, or equivalent options, this page provides verified technical context, calibrated transfer curve details, diagnostic configuration options, ASIL A safety compliance status, and OEM-validated EMC performance data specific to the BAD-306 variant.
Technical Context
The MLX90823GXP-BAD-306-SP implements a piezoresistive MEMS diaphragm with Wheatstone bridge transduction, coupled to a DSP-based CMOS interface IC featuring 16-bit microcontroller, EEPROM-programmable temperature compensation (up to third-order offset/gain), and configurable diagnostics. Its signal chain includes analog front-end filtering, ADC conversion, digital processing for linearization and clamping, and analog back-end output.
This variant is preconfigured for 0 to −1.0 bar relative pressure span with 0.5 V to 4.5 V ratiometric output, 1 ms default response time (0.4 ms fastest), and ±5 mBar typical pressure accuracy over temperature. Internal diagnostics include programmable over/under-voltage detection, broken connection monitoring, and pressure fault flagging via Upper/Lower Fault Band outputs.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Pressure Range | 0 to −1.0 bar relative: enables vacuum-level monitoring in crankcase and EVAP systems |
| Output Signal | 0.5–4.5 V ratiometric analog: scales with supply voltage for robustness against rail variation |
| Accuracy | ±0.5% FS lifetime accuracy: ensures long-term stability without recalibration in automotive deployments |
| Response Time | 0.4 ms (fastest): supports dynamic vacuum transient detection in real-time engine control |
| Operating Temp | −40°C to 160°C: qualified for under-hood placement with 10 min at 170°C short-duration tolerance |
| Supply Voltage | 4.5–5.5 V nominal, ±40 V extended: withstands load dump and reverse battery conditions |
| Safety Compliance | ASIL A SEooC per ISO 26262: supports integration into safety-aware vehicle architectures |
Pinout & Package
The MLX90823GXP-BAD-306-SP uses the SMP7 surface-mount package - a PCB-less, gel-filled, ridged housing enabling direct adhesive sealing to pressure ports. Dimensions are 7.0 × 5.5 × 3.5 mm (L × W × H) with integrated passive components (C1 = 47 nF, C2/C3 = 100 nF each).
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 | Ground (GND) | Primary ground connection; either Pin 1 or Pin 3 may be used - second GND pin may float |
| 2 | Analog Output | Ratiometric voltage output (0.5–4.5 V); internally clamped to 0.3–4.7 V; fault-indicating outside that range |
| 3 | Ground (GND) | Secondary ground terminal; electrically identical to Pin 1; not required to connect both |
| 4 | Supply Input (VDD) | 4.5–5.5 V nominal supply; supports ±40 V over/under-voltage protection with 20 mA current limit |
| 5–7 | Test Pins | Factory programming and test access only; not intended for end-user connection or circuit routing |
Key Features
| Feature | Design Value |
|---|---|
| PCB-less SMP7 package with sealing ridges | Enables direct glue-mounting onto metal/plastic pressure ports without PCB assembly or gasketing |
| Integrated passive components | Eliminates need for external capacitors (C1/C2/C3 embedded), reducing BOM count and improving EMC immunity |
| Configurable diagnostics via PTC04 | Allows field-programming of fault thresholds (OV/UV), pressure error flags, and fault band polarity per system requirements |
| Harsh media resistance | Validated against halogens, acids, and hydrocarbons - suitable for fuel vapor, oil mist, and crankcase gas exposure |
| AEC-Q100 & AEC-Q103-002 qualified | Meets automotive reliability standards for temperature cycling, humidity, mechanical shock, and EMC per leading OEM specs |
Applications
| Fuel Vapor Pressure Monitoring | Crankcase Ventilation (PCV) System |
|---|---|
Use Scenario: Real-time measurement of fuel tank vapor pressure during refueling and purge cycles to comply with evaporative emissions regulations. IC Role / Device Role / Timing Role: Relative pressure sensor providing analog feedback to the PCM for closed-loop EVAP system control. Use Value: Enables precise leak detection down to 0.5 mm H₂O using the −0.017 to +0.345 bar BAF-305 variant's resolution - though MLX90823GXP-BAD-306-SP's 0 to −1.0 bar range supports high-vacuum purge validation. | Use Scenario: Continuous monitoring of crankcase vacuum/pressure in turbocharged gasoline and diesel engines to prevent oil leaks and seal degradation. IC Role / Device Role / Timing Role: Absolute reference point for PCV valve actuation logic, detecting abnormal blow-by or blocked breather lines. Use Value: MLX90823GXP-BAD-306-SP's −1.0 bar full-scale range captures deep vacuum events during wide-open throttle, while its 0.4 ms response detects rapid pressure transients before mechanical failure occurs. |
| Engine Air Intake Manifold Vacuum | Aftertreatment Filter Differential Pressure |
Use Scenario: Measuring manifold absolute pressure (MAP) referenced to atmosphere for EGR and boost control in downsized engines. IC Role / Device Role / Timing Role: Relative pressure transducer delivering fast, stable analog output to the ECU for air mass calculation and torque estimation. Use Value: Ratiometric output and ±0.5% FS accuracy ensure consistent volumetric efficiency modeling across battery voltage fluctuations and ambient temperature extremes. | Use Scenario: Detecting soot loading in diesel particulate filters (DPF) or gasoline particulate filters (GPF) by measuring pressure drop across the filter media. IC Role / Device Role / Timing Role: High-stability differential pressure sensor mounted upstream/downstream of the filter element. Use Value: MLX90823GXP-BAD-306-SP's −1.0 bar range accommodates large ΔP in clogged filters, while its AEC-Q103 qualification ensures operation in hot exhaust proximity. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar relative pressure sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MLX90821GXP-BAD-306-RE | Same SMP7 package and 0 to −1.0 bar range, but lacks ASIL A development artifacts and diagnostic configurability; no EEPROM programmability | Targeted at cost-sensitive non-safety-critical applications; not qualified to ISO 26262 SEooC requirements | Select MLX90821GXP-BAD-306-RE only if functional safety certification and field calibration are unnecessary |
| MPXV7025GP | 0 to −25 kPa (−0.25 bar) range, 5 V supply, 0.2–4.8 V output; no integrated passives or diagnostics; uncalibrated at delivery | Requires external compensation, filtering, and calibration; limited to lower vacuum ranges and non-automotive environments | Choose MPXV7025GP only for prototyping or industrial vacuum gauges where full automotive qualification is not required |
Compared with MLX90821GXP-BAD-306-RE and MPXV7025GP, the MLX90823GXP-BAD-306-SP delivers certified ASIL A readiness, factory calibration with EEPROM programmability, integrated EMC-optimized passives, and validated harsh-media resistance - making it the only option qualified for production deployment in safety-critical automotive vacuum monitoring systems.
Availability
MLX90823GXP-BAD-306-SP is available at Aetrix Electronics and suitable for automotive crankcase ventilation, fuel vapor pressure monitoring, and aftertreatment filter differential pressure sensing requiring stable component supply, long-lifecycle support, and AEC-Q100/AEC-Q103 compliance.
Supply support for MLX90823GXP-BAD-306-SP includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Melexis is a Belgian semiconductor company specializing in magnetic, infrared, and pressure sensors for automotive and industrial markets, with design centers in Europe and Asia.
The MLX90823 product line was developed specifically for high-reliability relative pressure measurement in harsh automotive environments - emphasizing EMC resilience, media resistance, and functional safety readiness from silicon through packaging.
FAQ
What pressure range does the MLX90823GXP-BAD-306-SP measure?
The MLX90823GXP-BAD-306-SP measures a relative pressure range of 0 to −1.0 bar (i.e., vacuum from atmospheric up to 100 kPa below ambient). This is factory-programmed and fixed for this variant, with corresponding 0.5–4.5 V ratiometric analog output scaling linearly across the span.
Is the MLX90823GXP-BAD-306-SP calibrated before shipment?
Yes, the MLX90823GXP-BAD-306-SP is fully factory-calibrated across temperature and pressure, with compensation coefficients stored in on-chip EEPROM. No end-user calibration is required; the device delivers ±0.5% full-scale lifetime accuracy out-of-box, including temperature drift compensation up to third order.
Can the MLX90823GXP-BAD-306-SP be reprogrammed in-system?
Yes, the MLX90823GXP-BAD-306-SP supports in-system programming of diagnostics, fault thresholds, and pressure transfer curves using the Melexis PTC04 programming tool via its dedicated test pins. This enables customization of UV/OV detection levels, fault band polarity, and linearization parameters without changing hardware.
What is the operating temperature range of the MLX90823GXP-BAD-306-SP?
The MLX90823GXP-BAD-306-SP operates from −40°C to +160°C continuously, with short-duration tolerance up to +170°C for ≤10 minutes (max 20 hours cumulative over life). This rating is validated per AEC-Q100 Grade 0 and applies to the full specified pressure and output performance.
Does the MLX90823GXP-BAD-306-SP require external passive components?
No, the MLX90823GXP-BAD-306-SP integrates all required passive components (C1 = 47 nF, C2 = C3 = 100 nF) within its SMP7 package. The design eliminates external capacitors, simplifying layout, improving EMC immunity, and reducing bill-of-materials count for production modules.
MLX90823GXP-BAD-306-SP Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Melexis Technologies NV
- Series:
- -
- Package/Case:
- 4-SIP Module
- Packaging:
- Bag
- Product Status:
- Active
- Applications:
- Board Mount
- Pressure Type:
- Differential
- Operating Pressure:
- -14.5PSI ~ 0PSI (-100kPa ~ 0kPa)
- Output Type:
- Analog Voltage
- Output:
- 0.5 V ~ 5 V
- Accuracy:
- ±0.5%
- Voltage - Supply:
- 4.5V ~ 5.5V
- Port Size:
- -
- Port Style:
- No Port
- Features:
- Temperature Compensated
- Termination Style:
- -
- Maximum Pressure:
- 72.52PSI (500kPa)
- Operating Temperature:
- -40°C ~ 160°C
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Through Hole
- Supplier Device Package:
- SMP-4
MLX90823GXP-BAD-306-SP FAQ
1.How can I place an order for MLX90823GXP-BAD-306-SP through Aetrix?
Please submit a Request for Quotation (RFQ) for MLX90823GXP-BAD-306-SP on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MLX90823GXP-BAD-306-SP reliable?
The price and inventory of MLX90823GXP-BAD-306-SP are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MLX90823GXP-BAD-306-SP is usually 5 days.
3.What payment methods are accepted for MLX90823GXP-BAD-306-SP?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MLX90823GXP-BAD-306-SP transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MLX90823GXP-BAD-306-SP?
MLX90823GXP-BAD-306-SP orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MLX90823GXP-BAD-306-SP order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MLX90823GXP-BAD-306-SP?
For technical support, including MLX90823GXP-BAD-306-SP datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MLX90823GXP-BAD-306-SP requirements.
6.How does Aetrix verify that MLX90823GXP-BAD-306-SP is sourced from the original manufacturer or authorized distributors?
All MLX90823GXP-BAD-306-SP products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MLX90823GXP-BAD-306-SP meets industry standards.
7.What is the process for return or replacement of MLX90823GXP-BAD-306-SP?
All MLX90823GXP-BAD-306-SP units undergo pre-shipment inspection (PSI). If there is an issue with MLX90823GXP-BAD-306-SP, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MLX90823GXP-BAD-306-SP part is unused and in its original packaging.
Return procedure for MLX90823GXP-BAD-306-SP:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MLX90823GXP-BAD-306-SP Tags

-
DPS368XTSA1
Infineon Technologies

-
DPS310XTSA1
Infineon Technologies

-
LPS22HHTR
STMicroelectronics

-
ICP-20100
TDK InvenSense

-
ICP-10110
TDK InvenSense

-
LPS22DFTR
STMicroelectronics

-
LPS22HBTR
STMicroelectronics

-
BMP390
Bosch Sensortec

-
BMP581
Bosch Sensortec

-
BMP384
Bosch Sensortec

-
2511020213301
Würth Elektronik

-
ILPS22QSTR
STMicroelectronics
Tech Hub
Comparator circuit design covering voltage thresholds, input limits, open-collector outputs, LM393 wiring, op-amp differences, hysteresis, timing, window detection and practical fault diagnosis.
Schmitt triggers use separate rising and falling thresholds to stabilize slow or noisy signals. This guide covers hysteresis, 74HC14 and 74HCT14 selection, comparator calculations, RC oscillators and p…
Counterfeit components can hide behind convincing markings and passing basic function tests. This engineering reference covers source traceability, external inspection, X-ray, XRF, electrical testing, …
A practical engineering and sourcing framework covering lifecycle verification, lifetime-buy calculations, replacement qualification, supplier checks and counterfeit-risk controls.
TTL and CMOS logic families differ in thresholds, loading, output drive, power and timing. This engineering guide compares 74HC and 74HCT, calculates noise margins and checks 3.3 V/5 V compatibility.
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …