Melexis Technologies NV MLX90823GXP-BAF-305-SP
- Part No.:
- MLX90823GXP-BAF-305-SP
- Manufacturer:
- Melexis Technologies NV
- Category:
- Pressure Sensors, Transducers
- Package:
- 4-SIP Module
- Datasheet:
-
MLX90823GXP-BAF-305-SP.pdf
- Description:
- RELATIVE PRESSURE SENSOR WITH AN
- Quantity:
- Payment:

- Shipping:

Inventory:3,046
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MLX90823GXP-BAF-305-SP from Melexis is a PCB-less, factory-calibrated relative pressure sensor with ratiometric analog output (0.5–4.5 V), ±0.5% full-scale lifetime accuracy, and -0.017 to 0.345 bar measurement range. It integrates MEMS, CMOS interface IC, and passive components in an SMP7 package, qualified to AEC-Q100 and AEC-Q103-002 for automotive crankcase ventilation and fuel vapor pressure monitoring.
For engineers reviewing the MLX90823GXP-BAF-305-SP datasheet, pinout, applications, or equivalent options, this page delivers verified technical context, calibrated transfer curve details, diagnostic configuration options, ASIL-A safety compliance per ISO 26262, and real-world integration guidance for harsh-media automotive sensing.
Technical Context
The MLX90823GXP-BAF-305-SP implements a DSP-based signal chain with integrated Wheatstone bridge MEMS diaphragm, 16-bit microcontroller for temperature compensation (up to third-order offset/gain), and programmable linearization. Its analog front-end includes filtering and ADC conversion, while digital back-end handles clamping, diagnostics, and EEPROM-stored calibration parameters (O0–O3, G0–G3, L0–L1).
It features dual ground pins (pins 1 and 3), three test pins (5–7), and a ratiometric output referenced to VDD (4.5–5.5 V). Diagnostics include configurable broken-connection detection, over/under-voltage flags (default 5.7 V / 4.3 V), and internal fault reporting via Upper/Lower Fault Bands (0–3%VDD / 97–100%VDD).
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Pressure Range | -0.017 to 0.345 bar relative - enables precise low-differential monitoring in crankcase ventilation systems. |
| Output Signal | 0.5–4.5 V ratiometric analog - scales linearly with supply voltage, eliminating need for external reference. |
| Accuracy | ±0.5% FS lifetime accuracy - ensures long-term stability without recalibration in automotive under-hood environments. |
| Response Time | 0.4 ms (fastest) - supports dynamic pressure event capture in engine management applications. |
| Operating Temp | -40°C to +160°C (170°C short-term) - validated for continuous use in high-temperature powertrain locations. |
| EMC Compliance | OEM-grade EMC performance - achieved via integrated 47nF/100nF/100nF passive network, no external filtering required. |
| Safety Certification | ASIL-A SEooC per ISO 26262 - provides certified safety element for functional safety architectures without additional qualification effort. |
Pinout & Package
SMP7 package: 7-pin, PCB-less molded module with ridges for glue-based pressure sealing; dimensions 7.0 × 5.5 × 3.2 mm (L×W×H); bottom-side gel port for pressure media exposure.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 | Ground (GND) | Primary ground connection; either pin 1 or 3 may be used - simplifies layout with single-point grounding. |
| 2 | Analog Output | Ratiometric voltage output (0.5–4.5 V); internally buffered with 100 nF capacitor - eliminates need for external decoupling. |
| 3 | Ground (GND) | Secondary ground option; electrically identical to pin 1 - allows redundancy or mechanical strain relief routing. |
| 4 | Supply Input (VDD) | 4.5–5.5 V nominal supply; supports ±40 V over/under-voltage protection - withstands load-dump and reverse-battery conditions. |
| 5–7 | Test Pins | Factory programming and diagnostics interface; not user-accessible in final application - reserved for PTC04 tool calibration and validation. |
Key Features
| Feature | Design Value |
|---|---|
| PCB-less integrated package | Eliminates board-level assembly; ridged housing enables direct gluing to metal housings for hermetic pressure coupling. |
| Factory-calibrated transfer curve | Pre-programmed P1 = -0.017 bar / P2 = 0.345 bar, O1 = 0.5 V / O2 = 4.5 V - reduces system-level calibration time and cost. |
| Configurable diagnostics | EEPROM-programmable fault sources (e.g., supply OV/UV, broken membrane) with selectable Low/High Fault Band mapping - enables application-specific failure response. |
| Harsh-media resistance | Validated against halogens and acids - suitable for direct exposure to crankcase vapors and fuel vapor without protective coating. |
| ASIL-A SEooC development | Delivers certified safety evidence (FMEDA, FTT, safety manual) - accelerates ISO 26262 integration into ECU safety plans. |
Applications
| Crankcase Ventilation Monitoring | Fuel Vapor Pressure Sensing |
|---|---|
Use Scenario: Real-time detection of abnormal pressure buildup in engine crankcase due to blow-by gases. IC Role / Device Role / Timing Role: Relative pressure transducer measuring differential pressure between crankcase and ambient atmosphere. Use Value: Enables early detection of piston ring wear or PCV valve failure, supporting predictive maintenance and emissions compliance. |
Use Scenario: Monitoring vapor pressure inside fuel tank during refueling and thermal expansion cycles. IC Role / Device Role / Timing Role: Low-range analog pressure sensor interfacing directly with EVAP control module. Use Value: Supports onboard refueling vapor recovery (ORVR) and leak detection (LDI) with ±0.017–0.345 bar full-scale resolution. |
| Engine Oil Filter Clogging Detection | Brake Booster Vacuum Monitoring |
Use Scenario: Tracking pressure drop across oil filter to identify clogging before oil flow restriction impacts engine lubrication. IC Role / Device Role / Timing Role: Differential pressure sensor mounted across filter inlet/outlet ports. Use Value: Provides accurate, drift-free ΔP measurement at low flow rates - critical for extended oil change intervals. |
Use Scenario: Measuring vacuum level in brake booster reservoir to ensure sufficient assist pressure during braking events. IC Role / Device Role / Timing Role: Absolute-referenced relative pressure sensor detecting vacuum loss from leaks or pump degradation. Use Value: Delivers fast 0.4 ms response and ASIL-A compliance - essential for active brake system safety integrity. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar relative pressure sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MLX90821GXP-BAF-305-RE | Same SMP7 package and pressure range (-0.017 to 0.345 bar), but lacks ASIL-A SEooC certification and diagnostic configurability. | Targeted at non-safety-critical HVAC or industrial monitoring where functional safety is not mandated. | Select MLX90821GXP-BAF-305-RE only if ISO 26262 compliance and programmable diagnostics are unnecessary. |
| MPXV7025GP | Legacy Freescale analog sensor; 0–25 kPa range (0–0.25 bar), ±5% FS accuracy, no integrated diagnostics or ASIL support. | Used in legacy automotive designs with lower accuracy requirements and no safety architecture integration. | MLX90823GXP-BAF-305-SP offers 10× better accuracy, built-in diagnostics, and safety certification - upgrade recommended for new designs. |
Compared with MLX90821GXP-BAF-305-RE and MPXV7025GP, the MLX90823GXP-BAF-305-SP uniquely combines AEC-Q103-002 qualification, ASIL-A SEooC status, factory-programmed low-range transfer curve, and configurable diagnostics - making it the only drop-in solution for safety-critical, high-accuracy crankcase and fuel vapor sensing.
Availability
MLX90823GXP-BAF-305-SP is available at Aetrix Electronics and suitable for automotive crankcase ventilation, fuel vapor pressure monitoring, and brake booster vacuum sensing requiring stable component supply, long-lifecycle assurance, and AEC-compliant traceability.
Supply support for MLX90823GXP-BAF-305-SP includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Melexis is a Belgian semiconductor company specializing in magnetic, infrared, and pressure sensors for automotive and industrial markets, with design centers in Europe and Asia.
The MLX90823 product line delivers fully integrated, AEC-qualified relative pressure sensors targeting harsh-environment automotive applications including powertrain, emissions control, and chassis systems.
FAQ
What is the calibrated pressure range of the MLX90823GXP-BAF-305-SP?
The MLX90823GXP-BAF-305-SP is factory calibrated for a relative pressure range of -0.017 bar to +0.345 bar, with corresponding analog output spanning 0.5 V to 4.5 V. This narrow, low-differential span is optimized for crankcase ventilation and fuel vapor pressure sensing, and the calibration parameters are stored in on-chip EEPROM.
Does the MLX90823GXP-BAF-305-SP require external passive components for operation?
No, the MLX90823GXP-BAF-305-SP integrates all required passives - including 47 nF (C1), 100 nF (C2), and 100 nF (C3) capacitors - within its SMP7 package. This eliminates external filtering components and ensures OEM-grade EMC performance without layout-dependent tuning.
How is the MLX90823GXP-BAF-305-SP programmed and calibrated?
The MLX90823GXP-BAF-305-SP is factory calibrated and fully programmable via its test pins (5–7) using the Melexis PTC04 programming tool. Calibration curves, diagnostic thresholds, and temperature compensation coefficients (O0–O3, G0–G3) are written to on-chip EEPROM during production or field reconfiguration.
What safety standard compliance does the MLX90823GXP-BAF-305-SP provide?
The MLX90823GXP-BAF-305-SP is developed as an ASIL-A Safety Element out of Context (SEooC) per ISO 26262, with full FMEDA, safety manual, and hardware/software safety analysis documentation provided by Melexis. It is also qualified to AEC-Q100 (Grade 0) and AEC-Q103-002 for pressure sensors.
Can both GND pins (1 and 3) be connected simultaneously on the MLX90823GXP-BAF-305-SP?
Yes, both GND pins (1 and 3) may be connected, though only one is required for proper operation. Connecting both improves mechanical robustness and current-handling capability in high-vibration environments, and introduces no electrical conflict since they are internally tied to the same ground net.
MLX90823GXP-BAF-305-SP Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Melexis Technologies NV
- Series:
- -
- Package/Case:
- 4-SIP Module
- Packaging:
- Bag
- Product Status:
- Active
- Applications:
- Board Mount
- Pressure Type:
- Differential
- Operating Pressure:
- -0.25PSI ~ 5PSI (-1.7kPa ~ 34.5kPa)
- Output Type:
- Analog Voltage
- Output:
- 0.5 V ~ 4.5 V
- Accuracy:
- ±0.5%
- Voltage - Supply:
- 4.5V ~ 5.5V
- Port Size:
- -
- Port Style:
- No Port
- Features:
- Temperature Compensated
- Termination Style:
- -
- Maximum Pressure:
- 72.52PSI (500kPa)
- Operating Temperature:
- -40°C ~ 160°C
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Through Hole
- Supplier Device Package:
- SMP-4
MLX90823GXP-BAF-305-SP FAQ
1.How can I place an order for MLX90823GXP-BAF-305-SP through Aetrix?
Please submit a Request for Quotation (RFQ) for MLX90823GXP-BAF-305-SP on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MLX90823GXP-BAF-305-SP reliable?
The price and inventory of MLX90823GXP-BAF-305-SP are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MLX90823GXP-BAF-305-SP is usually 5 days.
3.What payment methods are accepted for MLX90823GXP-BAF-305-SP?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MLX90823GXP-BAF-305-SP transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MLX90823GXP-BAF-305-SP?
MLX90823GXP-BAF-305-SP orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MLX90823GXP-BAF-305-SP order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MLX90823GXP-BAF-305-SP?
For technical support, including MLX90823GXP-BAF-305-SP datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MLX90823GXP-BAF-305-SP requirements.
6.How does Aetrix verify that MLX90823GXP-BAF-305-SP is sourced from the original manufacturer or authorized distributors?
All MLX90823GXP-BAF-305-SP products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MLX90823GXP-BAF-305-SP meets industry standards.
7.What is the process for return or replacement of MLX90823GXP-BAF-305-SP?
All MLX90823GXP-BAF-305-SP units undergo pre-shipment inspection (PSI). If there is an issue with MLX90823GXP-BAF-305-SP, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MLX90823GXP-BAF-305-SP part is unused and in its original packaging.
Return procedure for MLX90823GXP-BAF-305-SP:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MLX90823GXP-BAF-305-SP Tags

-
DPS368XTSA1
Infineon Technologies

-
DPS310XTSA1
Infineon Technologies

-
LPS22HHTR
STMicroelectronics

-
ICP-20100
TDK InvenSense

-
ICP-10110
TDK InvenSense

-
LPS22DFTR
STMicroelectronics

-
LPS22HBTR
STMicroelectronics

-
BMP390
Bosch Sensortec

-
BMP581
Bosch Sensortec

-
BMP384
Bosch Sensortec

-
2511020213301
Würth Elektronik

-
ILPS22QSTR
STMicroelectronics
Tech Hub
Comparator circuit design covering voltage thresholds, input limits, open-collector outputs, LM393 wiring, op-amp differences, hysteresis, timing, window detection and practical fault diagnosis.
Schmitt triggers use separate rising and falling thresholds to stabilize slow or noisy signals. This guide covers hysteresis, 74HC14 and 74HCT14 selection, comparator calculations, RC oscillators and p…
Counterfeit components can hide behind convincing markings and passing basic function tests. This engineering reference covers source traceability, external inspection, X-ray, XRF, electrical testing, …
A practical engineering and sourcing framework covering lifecycle verification, lifetime-buy calculations, replacement qualification, supplier checks and counterfeit-risk controls.
TTL and CMOS logic families differ in thresholds, loading, output drive, power and timing. This engineering guide compares 74HC and 74HCT, calculates noise margins and checks 3.3 V/5 V compatibility.
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …