Melexis Technologies NV MLX90830LXG-BAH-001-SP
- Part No.:
- MLX90830LXG-BAH-001-SP
- Manufacturer:
- Melexis Technologies NV
- Category:
- Pressure Sensors, Transducers
- Package:
- -
- Datasheet:
-
MLX90830LXG-BAH-001-SP.pdf
- Description:
- PRESSURE SENSOR FORMID PRESSURE
- Quantity:
- Payment:

- Shipping:

Inventory:2,890
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MLX90830LXG-BAH-001-SP from Melexis is an AEC-Q100-qualified absolute pressure sensor with ratiometric analog output, 0–10.342 bar full-scale range, ±0.5% FS lifetime accuracy, and automotive-grade operation from −40°C to +150°C. It integrates MEMS sensing, 16-bit microcontroller, analog front-end, voltage regulators, and diagnostics for thermal management in e-compressors and expansion valves.
For engineers reviewing the MLX90830LXG-BAH-001-SP datasheet, pinout, applications, or equivalent options, this page delivers verified technical context, calibrated transfer curve values, Triphibian® robustness data, ASIL-A safety compliance, and diagnostic configuration details essential for EV coolant and HVAC-R system integration.
Technical Context
The MLX90830LXG-BAH-001-SP implements Triphibian® suspended-cantilever MEMS technology for pressure spike immunity up to 2000 bar/msec and burst resistance to 210 bar. Its DSP-based signal chain performs real-time temperature compensation using third-order EEPROM-programmable offset (O0–O3) and gain (G0–G3) coefficients.
It features configurable diagnostics including broken connection detection, over/under-voltage monitoring (default thresholds: 4.2 V UV / 5.55 V OV), and fault-band signaling (0–3% VDD low band / 97–100% VDD high band). The device operates with 4.5–5.5 V supply, draws 9.5–12 mA typical current, and achieves 0.4 ms fastest response time.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Pressure Range | 0 to 10.342 bar absolute - calibrated for refrigerant and liquid media in EV thermal systems |
| Output Signal | 0.5–4.5 V ratiometric analog - linear with supply voltage, enabling stable readings under rail variation |
| Accuracy | ±0.5% full scale lifetime accuracy - includes temperature drift, long-term stability, and calibration uncertainty |
| Response Time | 0.4 ms (fastest) - supports dynamic pressure monitoring in fast-cycling e-compressor control loops |
| Operating Temp | −40°C to +150°C - qualified for under-hood and in-motor coolant sensing without derating |
| Supply Voltage | 4.5–5.5 V nominal - with ±40 V over/under-voltage protection enabling robustness against load-dump transients |
| Diagnostics | Configurable internal & broken-connection detection - outputs fault bands (0–3% or 97–100% VDD) for fail-safe system response |
Pinout & Package
MLX90830LXG-BAH-001-SP uses SOIC16 WB cavity-up package (XZ code), with exposed die cavity facing upward for direct media contact. Pin 1–16 follow standard SOIC numbering; cavity orientation confirmed per Figure 2 and Figure 3 of datasheet Rev 003.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 3, 6, 11, 14 | Ground (GND) | Four dedicated GND pins reduce ground impedance and improve EMC immunity in noisy powertrain environments |
| 7 | Supply (VSup) | Main 4.5–5.5 V supply input with ±40 V over/under-voltage protection and 20 mA fault-current limiting |
| 8 | Analog Output | Ratiometric 0.5–4.5 V output referenced to VSup; clamped at 0.3 V / 4.7 V; supports 47–220 nF capacitive load |
| 13 | Auxiliary Capacitor (VAUX) | Connects external capacitor to stabilize internal regulator; required for full EMC performance per Figure 8 |
| 9, 10, 12 | Test (TEST) | Factory programming and debug interface; not user-accessible in final application; tied internally during normal operation |
| 1, 2, 4, 5, 15, 16 | Not Connected (NC) | No internal connection; must remain unconnected on PCB to avoid parasitic coupling or mechanical stress |
Key Features
| Feature | Design Value |
|---|---|
| Triphibian® MEMS architecture | Suspended cantilever design eliminates rear-side pressure differential, enabling reliable operation in frozen media and gas–liquid mixtures |
| ASIL-A SEooC development | Developed per ISO 26262 as Safety Element out of Context - provides traceable safety artifacts for OEM integration into ASIL-B/C systems |
| Factory-calibrated transfer curve | EEPROM-stored P1=0 bar / P2=10.342 bar, O1=0.5 V / O2=4.5 V with LCL=0.3 V and HCL=4.7 V - eliminates field calibration effort |
| Configurable diagnostics | Per-pin broken-wire detection plus programmable internal diagnostics (UV/OV, membrane break, output error) mapped to fault bands |
| Extended voltage resilience | Withstands −40 V reverse supply and +40 V overvoltage for ≤2 hours - protects against battery reversal and load-dump events |
Applications
| EV E-Compressor Monitoring | HVAC-R Refrigerant Control |
|---|---|
|
Use Scenario: Real-time suction/discharge pressure feedback in electric vehicle air conditioning compressors. IC Role / Device Role / Timing Role: Absolute pressure sensor providing analog feedback to inverter controller for torque and speed modulation. Use Value: 0.4 ms response enables closed-loop control at >1 kHz update rate; ±0.5% FS accuracy ensures precise refrigerant charge management across −40°C to +150°C. |
Use Scenario: High-accuracy pressure monitoring in commercial refrigeration units using R134a, R1234yf, or CO₂. IC Role / Device Role / Timing Role: Media-isolated absolute pressure transducer interfacing directly with refrigerant lines via cavity-up SOIC package. Use Value: Triphibian® robustness ensures stable operation in liquid slugs and freeze-thaw cycles; chemical compatibility covers all common refrigerants. |
| Automotive Coolant System | Data Center Liquid Cooling |
|
Use Scenario: In-radiator or pump-integrated pressure sensing for electric vehicle battery thermal management loops. IC Role / Device Role / Timing Role: Absolute pressure sensor mounted directly on coolant manifold with media-facing cavity. Use Value: AEC-Q100 qualification and −40°C to +150°C operation guarantee reliability in high-vibration, high-temperature under-hood environments. |
Use Scenario: Rack-level coolant pressure monitoring in immersion or cold-plate liquid cooling systems for AI accelerators. IC Role / Device Role / Timing Role: Analog-output pressure node feeding industrial PLC or local microcontroller for flow regulation. Use Value: Ratiometric output maintains accuracy despite supply rail fluctuations in shared-power server racks; 0.5% FS accuracy supports predictive maintenance algorithms. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar absolute pressure sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MPX5700A | 70 bar range, 0–5 V output, no integrated microcontroller or diagnostics; requires external compensation | Lacks ASIL-A compliance, programmable diagnostics, and Triphibian® media robustness - limited to non-safety-critical HVAC use | Select only for cost-sensitive, non-automotive applications where factory calibration and fault signaling are unnecessary |
| SSM2205 | 10 bar range, 0.5–4.5 V ratiometric output, AEC-Q100 qualified, but no embedded MCU or EEPROM calibration storage | Requires external ADC and compensation firmware; no built-in broken-wire or overvoltage diagnostics | Choose when board space allows discrete signal conditioning and system-level diagnostics are already implemented |
Compared with MPX5700A and SSM2205, MLX90830LXG-BAH-001-SP delivers integrated signal processing, factory-programmed accuracy, and automotive-grade safety features - reducing BOM count, validation effort, and software overhead in EV and industrial thermal systems.
Availability
MLX90830LXG-BAH-001-SP is available at Aetrix Electronics and suitable for EV e-compressor control, HVAC-R refrigerant monitoring, and automotive coolant system applications requiring stable component supply, long-lifecycle support, and AEC-Q100 compliance.
Supply support for MLX90830LXG-BAH-001-SP includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Melexis is a Belgian semiconductor company specializing in intelligent sensors and driver ICs for automotive, industrial, and medical markets, with core expertise in magnetic, infrared, and pressure sensing.
The MLX90830 product line was developed specifically for high-reliability absolute pressure measurement in electrified thermal systems - combining MEMS innovation, ASIL-A functional safety, and chemical/media robustness for next-generation EV and HVAC-R platforms.
FAQ
What is the calibrated pressure range of the MLX90830LXG-BAH-001-SP?
The MLX90830LXG-BAH-001-SP is factory calibrated for 0 to 10.342 bar (0–150 PSI) absolute pressure, with corresponding 0.5–4.5 V ratiometric analog output. This range is stored in on-chip EEPROM and validated across −40°C to +150°C per AEC-Q100 requirements. The MLX90830LXG-BAH-001-SP does not support field re-ranging without PTC04 programming tool and calibration fixture.
Does the MLX90830LXG-BAH-001-SP require external components for basic operation?
Yes - the MLX90830LXG-BAH-001-SP requires an external capacitor on the VAUX pin (Pin 13) for internal regulator stability, as specified in Figure 8 of the datasheet. A 100 nF X7R ceramic capacitor is recommended. No external ADC or signal conditioning is needed due to its integrated 16-bit microcontroller and ratiometric analog output.
How does the MLX90830LXG-BAH-001-SP indicate fault conditions?
The MLX90830LXG-BAH-001-SP signals faults by driving its analog output into defined fault bands: 0–3% VDD (Lower Fault Band) or 97–100% VDD (Upper Fault Band). These bands are triggered by broken connections (e.g., open GND or VSup) or enabled internal diagnostics such as over/under-voltage, membrane failure, or output errors - all configurable via EEPROM.
Is the MLX90830LXG-BAH-001-SP compatible with liquid refrigerants like R134a and R1234yf?
Yes - the MLX90830LXG-BAH-001-SP is chemically compliant with common refrigerants including R134a, R1234yf, R744 (CO₂), and R290 (propane), as confirmed in the datasheet's "Robust in gas and liquid media" feature and AEC-Q103-002 qualification. Its Triphibian® cavity-up construction prevents leakage paths and withstands freeze-thaw cycling in mixed-phase media.
Can the MLX90830LXG-BAH-001-SP be programmed after soldering to the PCB?
Yes - the MLX90830LXG-BAH-001-SP supports post-soldering programming via its TEST pins (9, 10, 12) using the Melexis PTC04 tool. This enables final-system calibration, diagnostic configuration, and EEPROM parameter updates without requiring socketed test fixtures - critical for production-line trim and variant management.
MLX90830LXG-BAH-001-SP Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Melexis Technologies NV
- Series:
- -
- Package/Case:
- -
- Packaging:
- Bulk
- Product Status:
- Active
- Applications:
- -
- Pressure Type:
- -
- Operating Pressure:
- -
- Output Type:
- -
- Output:
- -
- Accuracy:
- -
- Voltage - Supply:
- -
- Port Size:
- -
- Port Style:
- -
- Features:
- -
- Termination Style:
- -
- Maximum Pressure:
- -
- Operating Temperature:
- -
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- -
- Supplier Device Package:
- -
MLX90830LXG-BAH-001-SP FAQ
1.How can I place an order for MLX90830LXG-BAH-001-SP through Aetrix?
Please submit a Request for Quotation (RFQ) for MLX90830LXG-BAH-001-SP on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MLX90830LXG-BAH-001-SP reliable?
The price and inventory of MLX90830LXG-BAH-001-SP are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MLX90830LXG-BAH-001-SP is usually 5 days.
3.What payment methods are accepted for MLX90830LXG-BAH-001-SP?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MLX90830LXG-BAH-001-SP transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MLX90830LXG-BAH-001-SP?
MLX90830LXG-BAH-001-SP orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MLX90830LXG-BAH-001-SP order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MLX90830LXG-BAH-001-SP?
For technical support, including MLX90830LXG-BAH-001-SP datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MLX90830LXG-BAH-001-SP requirements.
6.How does Aetrix verify that MLX90830LXG-BAH-001-SP is sourced from the original manufacturer or authorized distributors?
All MLX90830LXG-BAH-001-SP products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MLX90830LXG-BAH-001-SP meets industry standards.
7.What is the process for return or replacement of MLX90830LXG-BAH-001-SP?
All MLX90830LXG-BAH-001-SP units undergo pre-shipment inspection (PSI). If there is an issue with MLX90830LXG-BAH-001-SP, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MLX90830LXG-BAH-001-SP part is unused and in its original packaging.
Return procedure for MLX90830LXG-BAH-001-SP:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MLX90830LXG-BAH-001-SP Tags

-
DPS368XTSA1
Infineon Technologies

-
DPS310XTSA1
Infineon Technologies

-
LPS22HHTR
STMicroelectronics

-
ICP-20100
TDK InvenSense

-
ICP-10110
TDK InvenSense

-
LPS22DFTR
STMicroelectronics

-
LPS22HBTR
STMicroelectronics

-
BMP390
Bosch Sensortec

-
BMP581
Bosch Sensortec

-
BMP384
Bosch Sensortec

-
2511020213301
Würth Elektronik

-
ILPS22QSTR
STMicroelectronics
Tech Hub
Comparator circuit design covering voltage thresholds, input limits, open-collector outputs, LM393 wiring, op-amp differences, hysteresis, timing, window detection and practical fault diagnosis.
Schmitt triggers use separate rising and falling thresholds to stabilize slow or noisy signals. This guide covers hysteresis, 74HC14 and 74HCT14 selection, comparator calculations, RC oscillators and p…
Counterfeit components can hide behind convincing markings and passing basic function tests. This engineering reference covers source traceability, external inspection, X-ray, XRF, electrical testing, …
A practical engineering and sourcing framework covering lifecycle verification, lifetime-buy calculations, replacement qualification, supplier checks and counterfeit-risk controls.
TTL and CMOS logic families differ in thresholds, loading, output drive, power and timing. This engineering guide compares 74HC and 74HCT, calculates noise margins and checks 3.3 V/5 V compatibility.
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
