Analog Devices Inc./Maxim Integrated MXD1810UR41+
- Part No.:
- MXD1810UR41+
- Manufacturer:
- Analog Devices Inc./Maxim Integrated
- Category:
- Supervisors
- Package:
- TO-236-3, SC-59, SOT-23-3
- Datasheet:
-
MXD1810UR41+.pdf
- Description:
- IC SUPERVISOR 1 CHANNEL SOT23-3
- Quantity:
- Payment:

- Shipping:

Inventory:1,993
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MXD1810UR41+ from Maxim Integrated is a precision 5V-system microprocessor reset supervisor IC with active-low open-drain RESET output, factory-trimmed 4.12V reset threshold (±2.5% over temperature), 100ms minimum reset timeout, and guaranteed operation down to VCC = +1V. It monitors power supply integrity during power-up, brownout, and power-down in embedded controllers and portable equipment.
For engineers reviewing the MXD1810UR41+ datasheet, MXD1810UR41+ pinout, MXD1810UR41+ application, or MXD1810UR41+ equivalent, key selection criteria include its 4.12V threshold accuracy, 4µA supply current, SOT23-3 package compatibility, manual-reset immunity (not supported), and open-drain interface suitability for bidirectional μP reset pins.
Technical Context
The MXD1810UR41+ implements a precision bandgap-based voltage comparator with hysteresis to detect VCC drops below 4.12V, asserting RESET low within 5µs. Its internal timer guarantees ≥100ms reset assertion after VCC recovers, independent of supply ramp rate.
This device belongs to the MXD1810–MXD1813 series for +5V systems and uses BiCMOS process technology. It features no external components, transient immunity up to 100µs at 100mV overdrive, and operates across –40°C to +105°C without derating.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Reset Threshold | 4.12V ±2.5% over –40°C to +105°C - ensures reliable brownout detection for +5V logic rails |
| Supply Current | 4µA typical at +3.6V - enables multi-year battery life in portable monitoring applications |
| Reset Timeout | 100ms minimum - satisfies μP power-on reset timing requirements per Intel/ARM specifications |
| VCC Operating Range | +1.0V to +5.5V - guarantees valid RESET state even during deep brownout conditions |
| Output Type | Open-drain active-low with internal 5.5kΩ pullup - interfaces directly with bidirectional μP reset pins without external components |
| Package | SOT23-3 - 2.92mm × 1.3mm footprint compatible with high-density PCB layouts |
| Temperature Range | –40°C to +105°C - qualified for industrial and extended-temperature embedded control environments |
Pinout & Package
MXD1810UR41+ is housed in a 3-pin SOT23 package (U3-1 outline, land pattern 90-0179), with 100% lead(Pb)-free construction indicated by the '+' suffix.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 | RESET | Open-drain active-low reset output; sinks ≥10mA when asserted; internal 5.5kΩ pullup to VCC enables direct connection to bidirectional μP reset pins |
| 2 | VCC | Supply input and reset-threshold monitor node; accepts +1.0V to +5.5V; comparator ignores transients <100µs at 100mV overdrive |
| 3 | GND | Ground reference for all internal circuitry and reset comparator; must be connected to system ground plane for noise immunity |
Key Features
| Feature | Design Value |
|---|---|
| Precision 4.12V reset threshold | Factory-trimmed ±2.5% over full temperature range eliminates calibration overhead in production test |
| No external components required | Integrated pullup, comparator, and timer reduce BOM count and PCB area vs. discrete reset solutions |
| Low 4µA quiescent current | Enables use in always-on battery-backed systems such as smart meters and IoT edge sensors |
| Guaranteed RESET validity to VCC = +1V | Ensures deterministic reset behavior during deep undervoltage events where other supervisors fail |
| Transient-immune comparator | Rejects VCC glitches ≤100µs duration, preventing spurious resets in noisy industrial power environments |
Applications
| Industrial PLC Controllers | Smart Energy Meters |
|---|---|
|
Use Scenario: Monitoring 5V auxiliary supply in programmable logic controller I/O modules subject to 12V rail transients. IC Role / Device Role / Timing Role: Active-low reset supervisor ensuring μP restart only after stable 5V rail recovery, with 100ms timeout preventing premature firmware execution. Use Value: Eliminates need for external RC network and Schmitt trigger, reducing component count while maintaining EN 61000-4-4 ESD immunity compliance. |
Use Scenario: Power-on sequencing and brownout protection in battery-backed electricity meters with dual 5V/3.3V domains. IC Role / Device Role / Timing Role: Open-drain RESET output interfaces directly with ARM Cortex-M0+ bidirectional reset pin, enabling shared reset arbitration with RTC backup domain. Use Value: Internal 5.5kΩ pullup removes external resistor, saving 0.5mm² PCB area and improving long-term reliability in humid meter enclosures. |
| Network Attached Storage (NAS) Enclosures | Medical Diagnostic Handhelds |
|
Use Scenario: Supervising 5V system rail in fanless NAS units where thermal cycling causes gradual VCC droop during sustained disk activity. IC Role / Device Role / Timing Role: Precision 4.12V threshold detects marginal 5V regulation before data corruption occurs, asserting RESET before USB/SATA link failure. Use Value: ±2.5% threshold accuracy over temperature avoids false resets during ambient shifts from 0°C to 55°C, improving field uptime. |
Use Scenario: Ensuring deterministic boot sequence in portable ultrasound probes powered by Li-ion batteries discharging from 4.2V to 3.0V. IC Role / Device Role / Timing Role: Operates down to VCC = +1V, guaranteeing valid RESET signal throughout battery depletion-critical for FDA Class II device fault-safety compliance. Use Value: 4µA supply current extends probe runtime between charges without compromising reset integrity during low-battery shutdown. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar microprocessor reset supervision applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MAX809TRD3+T | 4.00V threshold (±2%), 140µA supply current, push-pull output | Lacks open-drain interface; requires external pullup for bidirectional μP pins | Select when lower cost and push-pull drive are acceptable, and board layout allows external resistor |
| TPS3808G33DBVR | 3.3V threshold, 1.1µA supply current, adjustable timeout via capacitor | Designed for 3.3V systems; not rated for 5V operation or 4.12V threshold accuracy | Prefer for ultra-low-power 3.3V applications where threshold and timeout flexibility outweigh fixed 5V compatibility |
Compared with MXD1810UR41+, MAX809TRD3+T offers higher supply current but simpler drive capability, while TPS3808G33DBVR provides superior power efficiency at the expense of 5V-system compatibility and fixed threshold precision-making MXD1810UR41+ optimal for space-constrained, high-reliability +5V embedded designs requiring open-drain interoperability.
Availability
MXD1810UR41+ is available at Aetrix Electronics and suitable for industrial PLC controllers, smart energy meters, network-attached storage enclosures, and medical diagnostic handhelds requiring stable component supply across extended temperature ranges and long product lifecycles.
Supply support for MXD1810UR41+ includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Maxim Integrated (now part of Analog Devices) is a semiconductor company specializing in high-performance analog, mixed-signal, and power management ICs for industrial, communications, and computing markets.
The MXD1810–MXD1813 family was designed specifically for cost-sensitive, space-constrained +5V microprocessor supervisory applications demanding precision threshold accuracy, ultra-low power, and minimal external components.
FAQ
What is the exact reset threshold voltage of MXD1810UR41+ and how stable is it over temperature?
The MXD1810UR41+ has a factory-set reset threshold of 4.12V with ±2.5% accuracy over the full operating range of –40°C to +105°C. This specification is guaranteed by design-not just typical-and ensures reliable brownout detection across industrial thermal environments without recalibration. The threshold remains stable due to on-chip bandgap reference trimming and BiCMOS process optimization.
Does MXD1810UR41+ support manual reset via an external pushbutton?
No, MXD1810UR41+ does not include manual reset functionality. That feature is exclusive to the MXD1813/MXD1818 variants (e.g., MXD1813UR41+). MXD1810UR41+ provides only power-supply monitoring with automatic reset assertion on VCC drop below 4.12V and a fixed 100ms timeout-no external RESET pin debouncing or pushbutton detection circuitry is integrated.
Can MXD1810UR41+ drive a standard microcontroller reset pin directly?
Yes, MXD1810UR41+ can drive standard microcontroller reset pins directly due to its open-drain active-low RESET output with internal 5.5kΩ pullup to VCC. This configuration interfaces natively with bidirectional reset pins (e.g., ARM Cortex-M, PIC, MSP430) without external components, satisfying IOL ≥10mA sink capability at VOUT = 0.4V and supporting common 3.3V/5V logic families.
What is the minimum VCC voltage at which MXD1810UR41+ guarantees valid RESET output state?
MXD1810UR41+ guarantees valid RESET/RESET output logic states down to VCC = +1.0V, as confirmed in the Absolute Maximum Ratings and Electrical Characteristics tables. This ensures deterministic reset behavior during deep brownout conditions where competing supervisors may enter undefined states-critical for fail-safe operation in battery-powered and safety-critical systems.
Is MXD1810UR41+ RoHS-compliant and what does the '+' suffix indicate?
Yes, MXD1810UR41+ is RoHS-compliant and lead(Pb)-free. The '+' suffix in the part number explicitly denotes lead-free packaging per JEDEC J-STD-609, replacing the legacy '-T' suffix used for leaded versions. This designation is verified in Maxim's official ordering information and package documentation (outline U3-1, land pattern 90-0179).
MXD1810UR41+ Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Analog Devices Inc./Maxim Integrated
- Series:
- -
- Package/Case:
- TO-236-3, SC-59, SOT-23-3
- Packaging:
- Strip
- Product Status:
- Obsolete
- Programmable:
- Not Verified
- Type:
- Power Supply Monitor
- Number of Voltages Monitored:
- 1
- Voltage - Threshold:
- 4.12V
- Output:
- Push-Pull, Totem Pole
- Reset:
- Active Low
- Reset Timeout:
- 100ms Minimum
- Operating Temperature:
- -40°C ~ 105°C (TA)
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- SOT-23-3
MXD1810UR41+ FAQ
1.How can I place an order for MXD1810UR41+ through Aetrix?
Please submit a Request for Quotation (RFQ) for MXD1810UR41+ on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MXD1810UR41+ reliable?
The price and inventory of MXD1810UR41+ are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MXD1810UR41+ is usually 5 days.
3.What payment methods are accepted for MXD1810UR41+?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MXD1810UR41+ transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MXD1810UR41+?
MXD1810UR41+ orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MXD1810UR41+ order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MXD1810UR41+?
For technical support, including MXD1810UR41+ datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MXD1810UR41+ requirements.
6.How does Aetrix verify that MXD1810UR41+ is sourced from the original manufacturer or authorized distributors?
All MXD1810UR41+ products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MXD1810UR41+ meets industry standards.
7.What is the process for return or replacement of MXD1810UR41+?
All MXD1810UR41+ units undergo pre-shipment inspection (PSI). If there is an issue with MXD1810UR41+, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MXD1810UR41+ part is unused and in its original packaging.
Return procedure for MXD1810UR41+:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MXD1810UR41+ Tags

-
MIC826SYMT-TR
Microchip Technology

-
APX803S-31SA-7
Diodes Incorporated

-
APX803L20-29SA-7
Diodes Incorporated
-
TPS3828-33DBVR
Texas Instruments

-
V6340RSP3B+
EM Microelectronic

-
EM6325CXSP5B-2.9+
EM Microelectronic

-
MCP120T-300I/TT
Microchip Technology

-
MCP130T-315I/TT
Microchip Technology

-
MCP120T-475I/TT
Microchip Technology

-
MCP111T-300E/TT
Microchip Technology

-
MCP120T-315I/TT
Microchip Technology

-
MCP809T-315I/TT
Microchip Technology
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…