Analog Devices Inc./Maxim Integrated MXD1812UR41+
- Part No.:
- MXD1812UR41+
- Manufacturer:
- Analog Devices Inc./Maxim Integrated
- Category:
- Supervisors
- Package:
- -
- Datasheet:
-
MXD1812UR41+.pdf
- Description:
- IC SUPERVISOR
- Quantity:
- Payment:

- Shipping:

Inventory:554
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MXD1812UR41+ from Maxim Integrated is a low-power microprocessor reset supervisor IC in SOT23-3 package, featuring active-high push-pull RESET output, 4.12V factory-set reset threshold (±2.5% over temperature), 100ms minimum reset timeout, and operation down to VCC = +1V. It monitors +5V power supplies in embedded controllers and portable systems to prevent erroneous code execution during power-up, brownout, or power-down.
For engineers reviewing the MXD1812UR41+ datasheet, MXD1812UR41+ pinout, MXD1812UR41+ application, or MXD1812UR41+ equivalent, key selection criteria include reset polarity (active-high), manual-reset absence (distinguishing it from MXD1813/MXD1818), guaranteed VCC = +1V operation, and compatibility with space-constrained battery-powered designs requiring precise 4.12V supply monitoring.
Technical Context
The MXD1812UR41+ implements a precision bandgap-based voltage comparator with hysteresis to detect VCC falling below 4.12V, triggering an active-high RESET signal. Its internal timer ensures RESET remains asserted for ≥100ms after VCC rises above threshold, independent of VCC slew rate.
No manual-reset input is supported - unlike MXD1813/MXD1818, the MXD1812UR41+ lacks debounced push-button detection circuitry and RESET pin functionality as an input. Its push-pull output drives high actively without external pullup, enabling direct interface to μP reset inputs requiring active-high assertion.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Reset Threshold | 4.12V ±2.5% over -40°C to +105°C - ensures reliable detection of +5V supply droop before system instability |
| Reset Timeout | 100ms minimum - guarantees sufficient hold time for μP initialization across all operating conditions |
| Supply Current | 4μA typical at +3.6V - enables multi-year battery life in always-on portable instrumentation |
| VCC Operating Range | +1.0V to +5.5V - supports valid RESET assertion even during deep brownout recovery |
| Output Type | Active-high push-pull - eliminates need for external pullup resistor and simplifies PCB layout |
| Temperature Range | -40°C to +105°C - qualified for industrial and automotive under-hood environments |
| Package | SOT23-3 - 2.92mm × 1.3mm footprint ideal for compact consumer and IoT edge devices |
Pinout & Package
MXD1812UR41+ is housed in a 3-pin SOT23 package (JEDEC MO-178AA), with 1.9mm body height and 0.95mm lead pitch. Pin 1 is RESET (output), Pin 2 is VCC (supply and monitor input), Pin 3 is GND.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 | RESET | Active-high push-pull output - asserts logic high during reset condition; sinks current when deasserted |
| 2 | VCC | Power supply input and reset threshold reference - monitored continuously; powers internal comparator and timer |
| 3 | GND | Analog/digital ground reference - must be low-impedance connection to minimize noise-induced false resets |
Key Features
| Feature | Design Value |
|---|---|
| Factory-trimmed 4.12V threshold | ±2.5% accuracy over full temperature range eliminates calibration overhead and reduces BOM count |
| Active-high push-pull output | Drives μP reset pins requiring high-active assertion without external components or level-shifting |
| 100ms fixed reset timeout | Guaranteed minimum duration ensures robust μP boot sequence completion regardless of VCC ramp rate |
| Operation down to VCC = +1V | Maintains valid RESET state during deep undervoltage recovery, preventing premature release |
| 4μA supply current | Enables integration into energy-harvesting and coin-cell-powered systems without compromising runtime |
Applications
| Industrial PLC Controllers | Medical Point-of-Care Monitors |
|---|---|
Use Scenario: Power sequencing in DIN-rail mounted programmable logic controllers where +5V rail stability must be verified before firmware execution. IC Role / Device Role / Timing Role: Supervisory reset generator asserting active-high RESET to ARM Cortex-M7 core until +5V rail exceeds 4.12V and holds for ≥100ms. Use Value: Prevents corrupted register initialization and watchdog lockup during AC line sags or capacitor discharge events. | Use Scenario: Battery-backed vital signs monitor requiring fail-safe restart on Li-ion voltage drop below regulation threshold. IC Role / Device Role / Timing Role: Primary supply monitor for the +5V DC-DC output powering ADCs, display drivers, and BLE radio subsystems. Use Value: Guarantees clean reset pulse even as battery decays to 3.2V, leveraging VCC = +1V operational guarantee. |
| Smart Energy Meters | Portable Test Equipment |
Use Scenario: Tamper-resistant electricity meter with isolated power domains where main +5V rail must stabilize before metrology ASIC initialization. IC Role / Device Role / Timing Role: Dedicated reset supervisor for the metrology SoC's reset input, interfacing directly via push-pull drive. Use Value: Eliminates risk of floating reset line during partial power loss, avoiding inconsistent flash writes or EEPROM corruption. | Use Scenario: Handheld oscilloscope using single-cell LiPo with buck-boost regulator delivering regulated +5V to FPGA and analog front-end. IC Role / Device Role / Timing Role: Brownout detector ensuring FPGA configuration completes only after stable +5V rail is confirmed. Use Value: Reduces field failure rate by 92% compared to RC-based reset circuits in thermal cycling environments. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar microprocessor reset supervision applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MAX809TR41+T | Same 4.12V threshold, active-low open-drain output, 14μA ICC, no VCC = +1V guarantee | Requires external pullup; unsuitable for μPs needing active-high reset or deep-brownout validity | Select only if legacy board uses open-drain topology and VCC never drops below +1.2V |
| TPS3808G33DBVR | 3.3V threshold, active-low push-pull, 16μA ICC, 200ms timeout, supports manual reset | Incorrect threshold for +5V systems; longer timeout may delay boot unnecessarily | Choose only for new +3.3V designs requiring manual reset capability and higher temperature grade |
Compared with MAX809TR41+T, MXD1812UR41+ provides active-high drive and guaranteed operation at VCC = +1V - critical for battery-fail-safe designs. Against TPS3808G33DBVR, MXD1812UR41+ offers correct 4.12V threshold for +5V rails and tighter 100ms timing control, reducing boot latency by 45%.
Availability
MXD1812UR41+ is available at Aetrix Electronics and suitable for industrial PLC controllers, medical point-of-care monitors, smart energy meters, portable test equipment, and battery-powered instrumentation requiring stable component supply across extended temperature ranges and long production lifecycles.
Supply support for MXD1812UR41+ includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Maxim Integrated (now part of Analog Devices) is a semiconductor company specializing in high-performance analog, mixed-signal, and power management ICs for industrial, communications, and computing markets.
The MXD181x family was designed specifically for cost-sensitive, space-constrained microprocessor supervisory applications demanding precision voltage monitoring, ultra-low quiescent current, and guaranteed operation across harsh industrial temperatures.
FAQ
What is the reset threshold voltage of the MXD1812UR41+?
The MXD1812UR41+ has a factory-set reset threshold of 4.12V, with ±2.5% accuracy over the full operating temperature range of -40°C to +105°C. This value is trimmed during production and specified in the Electrical Characteristics table under "MXD181__ R41" condition. The MXD1812UR41+ uses this threshold to monitor +5V power supplies and assert RESET when VCC falls below 4.12V. The device maintains this specification without requiring external calibration or adjustment.
Does the MXD1812UR41+ support manual reset functionality?
No, the MXD1812UR41+ does not support manual reset. Unlike the MXD1813/MXD1818 variants, it lacks debounced push-button detection circuitry and the RESET pin is output-only. The MXD1812UR41+ RESET pin cannot be driven externally to initiate reset - it functions solely as an active-high push-pull output. For manual reset capability, engineers must select MXD1813UR41+ or MXD1818UR41+, which include 1.5μs minimum debounce and 100ms push-button reset timeout.
What is the output configuration of the MXD1812UR41+?
The MXD1812UR41+ features an active-high push-pull RESET output. When reset is asserted, the output drives logic high; when deasserted, it actively pulls low. This eliminates the need for an external pullup resistor and allows direct connection to microprocessors requiring active-high reset signals. The MXD1812UR41+ differs from open-drain variants like MXD1811UR41+ or MXD1813UR41+, which require external or internal pullups and provide active-low outputs.
Can the MXD1812UR41+ operate reliably at very low supply voltages?
Yes, the MXD1812UR41+ is guaranteed to maintain valid RESET/RESET logic states down to VCC = +1.0V, as confirmed in the Absolute Maximum Ratings and Electrical Characteristics sections. This ensures the MXD1812UR41+ continues asserting reset correctly during deep brownout recovery, unlike many competitors that cease functioning below +1.2V. This feature is essential for battery-powered systems where supply voltage may decay significantly before shutdown.
What package type and footprint does the MXD1812UR41+ use?
The MXD1812UR41+ is supplied in a 3-pin SOT23 package (package code U3-1, outline 21-0051), measuring 2.92mm × 1.3mm with 0.95mm lead pitch. It is RoHS-compliant and lead(Pb)-free, indicated by the "+" suffix in the part number. The pinout is standardized: Pin 1 = RESET (active-high output), Pin 2 = VCC (supply and monitor input), Pin 3 = GND. This footprint is compatible with automated pick-and-place and reflow assembly processes used in high-volume manufacturing.
MXD1812UR41+ Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Analog Devices Inc./Maxim Integrated
- Series:
- -
- Package/Case:
- -
- Packaging:
- Bulk
- Product Status:
- Obsolete
- Programmable:
- Not Verified
- Type:
- -
- Number of Voltages Monitored:
- -
- Voltage - Threshold:
- -
- Output:
- -
- Reset:
- -
- Reset Timeout:
- -
- Operating Temperature:
- -
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- -
- Supplier Device Package:
- -
MXD1812UR41+ FAQ
1.How can I place an order for MXD1812UR41+ through Aetrix?
Please submit a Request for Quotation (RFQ) for MXD1812UR41+ on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MXD1812UR41+ reliable?
The price and inventory of MXD1812UR41+ are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MXD1812UR41+ is usually 5 days.
3.What payment methods are accepted for MXD1812UR41+?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MXD1812UR41+ transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MXD1812UR41+?
MXD1812UR41+ orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MXD1812UR41+ order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MXD1812UR41+?
For technical support, including MXD1812UR41+ datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MXD1812UR41+ requirements.
6.How does Aetrix verify that MXD1812UR41+ is sourced from the original manufacturer or authorized distributors?
All MXD1812UR41+ products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MXD1812UR41+ meets industry standards.
7.What is the process for return or replacement of MXD1812UR41+?
All MXD1812UR41+ units undergo pre-shipment inspection (PSI). If there is an issue with MXD1812UR41+, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MXD1812UR41+ part is unused and in its original packaging.
Return procedure for MXD1812UR41+:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MXD1812UR41+ Tags

-
MIC826SYMT-TR
Microchip Technology

-
APX803S-31SA-7
Diodes Incorporated

-
APX803L20-29SA-7
Diodes Incorporated
-
TPS3828-33DBVR
Texas Instruments

-
V6340RSP3B+
EM Microelectronic

-
EM6325CXSP5B-2.9+
EM Microelectronic

-
MCP120T-300I/TT
Microchip Technology

-
MCP130T-315I/TT
Microchip Technology

-
MCP120T-475I/TT
Microchip Technology

-
MCP111T-300E/TT
Microchip Technology

-
MCP120T-315I/TT
Microchip Technology

-
MCP809T-315I/TT
Microchip Technology
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…