Diodes Incorporated PT7M6129NLTA3EX
- Part No.:
- PT7M6129NLTA3EX
- Manufacturer:
- Diodes Incorporated
- Category:
- Supervisors
- Package:
- TO-236-3, SC-59, SOT-23-3
- Datasheet:
-
PT7M6129NLTA3EX.pdf
- Description:
- IC SUPERVISOR 1 CHANNEL SOT23-3
- Quantity:
- Payment:

- Shipping:

Inventory:4,348
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
PT7M6129NLTA3EX from Pericom Semiconductor is a precision ultra-low-power voltage detector with 2.9V threshold, N-channel open-drain active-low reset output, ±1.5% accuracy at 25°C, 0.9µA supply current at 3V, and 17µs propagation delay. It monitors VCC in battery-powered microcontrollers, PMICs, and embedded power rails to prevent brownout-induced system faults.
For engineers reviewing the PT7M6129NLTA3EX datasheet, PT7M6129NLTA3EX pinout, PT7M6129NLTA3EX application, or PT7M6129NLTA3EX equivalent, key selection criteria include threshold accuracy over temperature (±2.5% typ), hysteresis (5%), SOT23-3 package compatibility, and open-drain drive capability for flexible logic-level interfacing.
Technical Context
This device integrates a precision bandgap reference, comparator, and internally trimmed resistor network to set a fixed 2.9V detection threshold (VTH−) with 1.05× hysteresis (VTH+ = 3.045V). The internal 5% hysteresis prevents output oscillation during slow-rising or noisy supply transitions.
It operates across 1.2V–5.5V supply range and −40°C to +85°C ambient, delivering stable reset assertion when VCC falls below VTH− and release only after VCC exceeds VTH+. Output leakage is ≤1µA, supporting high-impedance pull-up configurations without significant current loss.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Detect Threshold | 2.9V ±1.5% at 25°C - sets precise brownout point for 3.0V nominal rails |
| Hysteresis | 5% (VTH+ = 3.045V) - eliminates chatter on marginal supply recovery |
| Supply Current | 0.9µA at 3V - enables multi-year operation in coin-cell–powered IoT sensors |
| Propagation Delay | 17µs typical - ensures timely reset assertion before MCU state corruption |
| Output Type | N-channel open-drain, active-low - allows wired-OR reset buses and level-shifting |
| Operating Range | 1.2V to 5.5V VCC - supports Li-ion, alkaline, and regulated 3.3V/5V systems |
| Temp Accuracy | ±2.5% over −40°C to +85°C - maintains reliability in automotive cabin and industrial edge nodes |
Pinout & Package
SOT23-3 package (JEDEC MO-178AA compliant), 2.9mm × 1.3mm footprint, 1.45mm height, lead-free and RoHS-compliant.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 (VCC) | Power Supply Input | Connects to monitored rail; powers internal circuitry and defines detection reference |
| 2 (GND) | Ground Reference | System ground return path; required for accurate threshold referencing |
| 3 (RST) | Open-Drain Reset Output | Active-low signal asserted when VCC < 2.9V; requires external pull-up for logic interface |
Key Features
| Feature | Design Value |
|---|---|
| Ultra-low quiescent current | 0.9µA at 3V enables >10-year battery life in always-on monitoring applications |
| Precision threshold trimming | ±1.5% initial accuracy eliminates need for external calibration components |
| Integrated hysteresis | 5% fixed hysteresis removes requirement for external feedback resistors |
| Wide supply range | 1.2V–5.5V operation supports direct connection to unregulated battery inputs |
| Fast response time | 17µs propagation delay ensures reset activation before MCU register corruption |
Applications
| Wearable Health Monitor | Industrial PLC I/O Module |
|---|---|
Use Scenario: Coin-cell–powered ECG sensor continuously monitors battery voltage to trigger graceful shutdown before data loss. IC Role / Device Role / Timing Role: Voltage detector asserts active-low RST to halt MCU execution and preserve flash integrity when VCC drops below 2.9V. Use Value: 0.9µA supply current extends battery life beyond 3 years; ±1.5% threshold ensures consistent shutdown voltage across production units. |
Use Scenario: 24V DC-powered digital input module uses local 3.3V LDO; PT7M6129NLTA3EX guards against LDO dropout during transient load surges. IC Role / Device Role / Timing Role: Monitors post-LDO 3.3V rail and forces system reset within 17µs if voltage sags below 2.9V. Use Value: 5% hysteresis prevents spurious resets during brief 100ms transients; SOT23-3 footprint saves PCB area in space-constrained DIN-rail modules. |
| Smart Meter Battery Backup | Automotive Body Control Unit |
Use Scenario: Lithium-thionyl chloride backup battery powers real-time clock and memory during main power failure. IC Role / Device Role / Timing Role: Detects backup battery decay below 2.9V and asserts RST to initiate nonvolatile data save before voltage collapse. Use Value: −40°C to +85°C rating ensures operation in outdoor meter enclosures; open-drain output interfaces directly with 3.3V MCU reset pin via 10kΩ pull-up. |
Use Scenario: BCM monitors 5V domain powering CAN transceivers and door lock actuators. IC Role / Device Role / Timing Role: Resets microcontroller when 5V rail dips below 2.9V due to alternator ripple or cold-crank sag. Use Value: 1.2V minimum operating voltage allows detection even during deep brownout; ±2.5% temp accuracy guarantees reliable reset across engine bay thermal cycles. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar voltage detector applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| TLV803EB29DPWR | 2.93V threshold, ±2.5% accuracy, 0.5µA ICC, SOT23-3, push-pull active-low | Push-pull output eliminates external pull-up but lacks hysteresis programmability | Select when board layout prohibits pull-up resistor or when lower ICC is critical |
| MAX809SEUR+T | 2.93V threshold, ±2.5% accuracy, 12µA ICC, SOT23-3, open-drain active-low | Higher supply current; no hysteresis specification in datasheet | Select when legacy qualification or long-term availability outweighs ultra-low-power needs |
Compared with PT7M6129NLTA3EX, TLV803EB29DPWR offers lower ICC but sacrifices hysteresis control, while MAX809SEUR+T provides broader industry recognition at the cost of 13× higher quiescent current-making PT7M6129NLTA3EX optimal for energy-constrained, thermally variable designs requiring deterministic hysteresis.
Availability
PT7M6129NLTA3EX is available at Aetrix Electronics and suitable for wearable health monitors, industrial PLC I/O modules, smart meter battery backup circuits, and automotive body control units requiring stable component supply across extended temperature and low-power constraints.
Supply support for PT7M6129NLTA3EX includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Pericom Semiconductor (now part of Diodes Incorporated) specializes in high-performance analog and mixed-signal ICs for timing, connectivity, and power management applications.
The PT7M61xx series was designed specifically for ultra-low-power voltage monitoring in portable, battery-operated, and thermally demanding embedded systems-emphasizing accuracy, minimal current draw, and robust hysteresis behavior.
FAQ
What is the exact detection threshold voltage and its tolerance for PT7M6129NLTA3EX?
The PT7M6129NLTA3EX has a nominal detection threshold (VTH−) of 2.9V with ±1.5% accuracy at 25°C. Over the full −40°C to +85°C operating range, threshold variation is specified as ±2.5% of the nominal value, meaning actual trip points fall between 2.828V and 2.972V under worst-case conditions.
Can PT7M6129NLTA3EX be used with a 1.8V supply rail?
Yes. The device operates from 1.2V to 5.5V, so it functions correctly on a 1.8V rail. However, its 2.9V threshold means it will assert reset continuously on a 1.8V supply-intended use is monitoring rails ≥2.9V (e.g., 3.0V, 3.3V, or 5.0V domains) where undervoltage detection is meaningful.
What external components are required for basic operation?
Only an external pull-up resistor on the RST pin is required for open-drain operation. Per datasheet guidance, pull-up values between 1kΩ and 510kΩ are acceptable; 10kΩ is typical. No capacitors or additional resistors are needed-the hysteresis, reference, and comparator are fully integrated.
How does the hysteresis function, and what is its design impact?
Hysteresis is fixed at 5%: VTH+ = 1.05 × VTH− = 3.045V. Reset releases only when VCC rises above this upper threshold, preventing oscillation during slow or noisy supply recovery. This eliminates need for external RC networks and ensures clean, chatter-free reset signaling in real-world power environments.
PT7M6129NLTA3EX Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Diodes Incorporated
- Series:
- -
- Package/Case:
- TO-236-3, SC-59, SOT-23-3
- Packaging:
- Tape & Reel (TR)
- Product Status:
- Obsolete
- Programmable:
- Not Verified
- Type:
- Simple Reset/Power-On Reset
- Number of Voltages Monitored:
- 1
- Voltage - Threshold:
- 2.9V
- Output:
- Open Drain or Open Collector
- Reset:
- Active Low
- Reset Timeout:
- 200µs Maximum
- Operating Temperature:
- -40°C ~ 85°C (TA)
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- SOT-23-3
PT7M6129NLTA3EX FAQ
1.How can I place an order for PT7M6129NLTA3EX through Aetrix?
Please submit a Request for Quotation (RFQ) for PT7M6129NLTA3EX on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for PT7M6129NLTA3EX reliable?
The price and inventory of PT7M6129NLTA3EX are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for PT7M6129NLTA3EX is usually 5 days.
3.What payment methods are accepted for PT7M6129NLTA3EX?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for PT7M6129NLTA3EX transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for PT7M6129NLTA3EX?
PT7M6129NLTA3EX orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your PT7M6129NLTA3EX order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for PT7M6129NLTA3EX?
For technical support, including PT7M6129NLTA3EX datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your PT7M6129NLTA3EX requirements.
6.How does Aetrix verify that PT7M6129NLTA3EX is sourced from the original manufacturer or authorized distributors?
All PT7M6129NLTA3EX products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that PT7M6129NLTA3EX meets industry standards.
7.What is the process for return or replacement of PT7M6129NLTA3EX?
All PT7M6129NLTA3EX units undergo pre-shipment inspection (PSI). If there is an issue with PT7M6129NLTA3EX, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The PT7M6129NLTA3EX part is unused and in its original packaging.
Return procedure for PT7M6129NLTA3EX:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
PT7M6129NLTA3EX Tags

-
MIC826SYMT-TR
Microchip Technology

-
APX803S-31SA-7
Diodes Incorporated

-
APX803L20-29SA-7
Diodes Incorporated
-
TPS3828-33DBVR
Texas Instruments

-
V6340RSP3B+
EM Microelectronic

-
EM6325CXSP5B-2.9+
EM Microelectronic

-
MCP120T-300I/TT
Microchip Technology

-
MCP130T-315I/TT
Microchip Technology

-
MCP120T-475I/TT
Microchip Technology

-
MCP111T-300E/TT
Microchip Technology

-
MCP120T-315I/TT
Microchip Technology

-
MCP809T-315I/TT
Microchip Technology
Tech Hub
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…
LDO regulator guide covering low dropout voltage, power dissipation, thermal design, PSRR, output noise, capacitor stability, adjustable LDO circuits, LDO vs buck converter and datasheet selection chec…
Conditional Access Module guide covering CAM meaning, CI/CI+ interface, smart card authorization, DVB security workflow, TV and set-top box compatibility, internal electronics, ESD protection, connecto…
Guide to electronic component obsolescence covering EOL risk, PCN/PDN notices, last-time buy planning, replacement options, form-fit-function validation, counterfeit risk and BOM lifecycle management.
18650 battery guide covering lithium-ion cell basics, 3.6V/3.7V voltage, 4.2V charging, mAh and Wh capacity, protected cells, chargers, BMS, series-parallel packs, holders, welding and sourcing checks.…
Hall effect sensor guide covering working principle, linear and digital sensors, Arduino circuits, current sensing, speed detection, automotive applications, A3144 examples, signal filtering and datash…
Product Change Notification guide for electronic components, covering PCN meaning, PCN vs PDN/EOL, common change types, risk levels, form-fit-function review, engineering validation, BOM control, LTB/L…
A practical guide to blend door actuators, covering HVAC function, symptoms, location, AC and heater issues, reset and calibration, replacement cost, electrical diagnosis, compatibility checks, and rep…