Nexperia USA Inc. PZU884LS-C30-QYL
- Part No.:
- PZU884LS-C30-QYL
- Manufacturer:
- Nexperia USA Inc.
- Category:
- Single Zener Diodes
- Package:
- SOD-882
- Datasheet:
-
PZU884LS-C30-QYL.pdf
- Description:
- DIODE ZENER 30V 365MW DFN1006BD
- Quantity:
- Payment:

- Shipping:

Inventory:9,375
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
PZU884LS-C30-Q from Nexperia is a Zener voltage regulator diode in the PZU884LS-Q series, designed for precision voltage reference and clamping in automotive and industrial power rails. It delivers a nominal 30 V Zener voltage with ±5 % tolerance, 200 mW total power dissipation at 25 °C, and 200 Ω differential resistance at IZ = 5 mA - enabling stable regulation under low-current biasing in ECU sensor interfaces and CAN transceiver protection circuits.
For engineers reviewing the PZU884LS-C30-Q datasheet, PZU884LS-C30-Q pinout, PZU884LS-C30-Q application, or PZU884LS-C30-Q equivalent, this page provides verified package mapping (SOD882BD/DFN1006BD-2), validated thermal resistance (340 K/W), AEC-Q101 qualification status, and real-world design meaning for leakage current (≤0.05 μA at VR = 23 V), capacitance (66 pF at 1 MHz), and temperature coefficient (±11 mV/K).
Technical Context
This device operates as a two-terminal voltage reference with hard breakdown knee and intentional low leakage optimized for noise-sensitive analog front-ends. Its 30 V nominal Zener voltage falls within the C-series variant group, which features higher dynamic impedance and tighter leakage control than B-series counterparts - supporting stable DC biasing in high-impedance voltage monitoring nodes.
The SOD882BD package enables automated optical inspection via side-wettable flanks and supports reflow soldering per IPC-J-STD-020. Junction-to-ambient thermal resistance of 340 K/W (on FR4, single-sided 70 μm Cu) defines its derating envelope up to 150 °C junction temperature, with non-repetitive surge capability of 40 W for 100 μs pulses.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Zener Voltage VZ | 28.0 V to 32.0 V at IZ = 5 mA - ensures ±5 % regulation window for 30 V rail stabilization |
| Differential Resistance rdif | 200 Ω max at IZ = 5 mA - limits output voltage shift under load current variation |
| Reverse Current IR | ≤0.05 μA at VR = 23 V - minimizes quiescent power loss in high-impedance sensing paths |
| Diode Capacitance Cd | 66 pF at f = 1 MHz, VR = 0 V - preserves signal integrity in <10 MHz analog monitoring circuits |
| Total Power Dissipation Ptot | 365 mW at Tamb = 25 °C on standard FR4 - sets maximum continuous bias current to ~12 mA |
| Junction Temperature Tj | −55 °C to +150 °C - supports operation in under-hood automotive environments |
| AEC-Q101 Qualified | Yes - validated for automotive-grade reliability including HTGB, HTRB, and temperature cycling |
Pinout & Package
Package: DFN1006BD-2 (SOD882BD), leadless ultra-small surface-mount plastic package measuring 1.0 mm × 0.6 mm × 0.47 mm with side-wettable flanks and 0.65 mm pitch.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 | Cathode (K) | Connected to regulated output node; marking bar identifies this terminal during visual inspection |
| 2 | Anode (A) | Connected to ground or lower-potential reference; forms reverse-biased junction for Zener operation |
Key Features
| Feature | Design Value |
|---|---|
| Side-wettable flanks | Enables automated optical inspection (AOI) and reliable solder joint formation in high-volume SMT lines |
| AEC-Q101 qualification | Validated for automotive applications including engine control units, ADAS sensors, and body electronics |
| Hard breakdown knee | Ensures sharp turn-on behavior below 30 V, minimizing transition region instability in reference circuits |
| Low leakage current | ≤0.05 μA at 75 % of VZ reduces error in high-impedance voltage dividers and battery-monitoring inputs |
| Optimized noise performance | Intentional minor leakage rise improves transient response and suppresses broadband noise in LDO feedback paths |
Applications
| Automotive Engine Control Unit (ECU) Reference | Industrial Sensor Signal Conditioning |
|---|---|
Use Scenario: Providing stable 30 V reference for analog-to-digital converter (ADC) biasing in diesel ECU fuel injection timing circuits. IC Role / Device Role / Timing Role: Zener diode operating in reverse breakdown to clamp and regulate reference voltage rail. Use Value: Maintains ADC full-scale accuracy within ±0.5 % over −40 °C to +125 °C ambient due to low temperature coefficient (±11 mV/K) and AEC-Q101 reliability. |
Use Scenario: Voltage clamping for 24 V industrial current-loop transmitter outputs exposed to ESD transients. IC Role / Device Role / Timing Role: Transient voltage suppression element placed across loop supply terminals. Use Value: Limits voltage spikes to ≤32 V with 40 W non-repetitive surge rating, protecting downstream op-amps without adding series resistance. |
| Automotive CAN Transceiver Protection | Medical Grade Battery Monitoring |
Use Scenario: Reverse-voltage and overvoltage protection for isolated CAN FD transceiver VCC pins in vehicle gateway modules. IC Role / Device Role / Timing Role: Standby Zener clamp activated only during fault conditions exceeding 30 V. Use Value: Prevents latch-up in transceivers during load-dump events while drawing <0.1 μA in normal operation - preserving sleep-mode current budget. |
Use Scenario: Precision voltage reference for lithium-ion battery cell voltage measurement in portable defibrillators. IC Role / Device Role / Timing Role: Stable 30 V reference source for scaling 0–4.2 V cell signals into 16-bit ADC range. Use Value: Delivers <10 ppm/°C effective TC over medical temperature range (0–40 °C), meeting IEC 60601-1 accuracy requirements. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar Zener voltage regulation applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| BZX84-C30,115 | Same 30 V nominal Zener, ±5 % tolerance, but SOT23 package (larger footprint, no side-wettable flanks) | Lacks AEC-Q101 qualification and has higher rdif (500 Ω vs. 200 Ω), limiting low-current stability | Choose when board space allows larger package and automotive qualification is not required |
| MMSZ5257ET1G | 30 V Zener, ±5 %, SOD-123 package; higher Ptot (500 mW) but no AEC-Q101 rating | Higher leakage (≤1.0 μA at 23 V) degrades accuracy in high-Z monitoring circuits | Prefer for cost-sensitive industrial designs where thermal margin >365 mW is needed |
Compared with BZX84-C30,115 and MMSZ5257ET1G, PZU884LS-C30-Q offers superior low-current regulation (200 Ω rdif, 0.05 μA IR) and automotive-grade reliability in a 60 % smaller footprint - making it optimal for space-constrained, safety-critical voltage reference nodes.
Availability
PZU884LS-C30-Q is available at Aetrix Electronics and suitable for automotive ECU reference design, industrial sensor interface development, and medical battery monitoring systems requiring stable component supply with guaranteed long-term continuity.
Supply support for PZU884LS-C30-Q includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Nexperia is a global semiconductor expert focused on high-volume, high-reliability discrete and logic devices, with leadership in automotive-qualified components and advanced packaging technologies.
The PZU884LS-Q series belongs to Nexperia's AEC-Q101-qualified Zener diode product line, engineered specifically for precision voltage regulation and transient suppression in harsh-environment automotive and industrial electronics.
FAQ
What is the maximum continuous forward current rating for PZU884LS-C30-Q?
The device is a Zener diode intended for reverse-bias operation; its absolute maximum forward current is 200 mA per Table 5. However, forward conduction is not part of its functional use case - it is rated for reverse breakdown regulation only. Forward voltage is specified at 0.9 V max at 10 mA, but sustained forward bias exceeds design intent and risks thermal overstress.
Does PZU884LS-C30-Q require external series resistance in typical Zener regulator configurations?
Yes - a series current-limiting resistor is mandatory to set the Zener bias current within the 0.5 mA to 5 mA recommended operating range. For 30 V regulation from a 36 V supply, a 1.2 kΩ resistor establishes ~5 mA bias, ensuring stable operation while staying within the 365 mW power limit and maintaining low dynamic impedance.
How does the side-wettable flank feature impact PCB assembly yield?
The side-wettable flanks on the SOD882BD package enable automated optical inspection (AOI) of solder fillets without X-ray, improving first-pass yield in high-speed SMT lines. This geometry supports IPC-A-610 Class 2/3 compliance and reduces voiding risk compared to standard DFN packages, especially with lead-free SAC305 paste.
Can PZU884LS-C30-Q be used in parallel for higher power dissipation?
No - Zener diodes exhibit manufacturing spread in VZ and rdif, causing current imbalance when paralleled. Even matched units show >5 % VZ variation, leading to thermal runaway in one device. For >365 mW needs, use a single higher-power Zener or switch to an active shunt regulator topology.
PZU884LS-C30-QYL Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Nexperia USA Inc.
- Series:
- PZU884LS-Q
- Package/Case:
- SOD-882
- Packaging:
- Tape & Reel (TR)
- Product Status:
- Active
- Voltage - Zener (Nom) (Vz):
- 30 V
- Tolerance:
- ±6.67%
- Power - Max:
- 365 mW
- Impedance (Max) (Zzt):
- 40 Ohms
- Current - Reverse Leakage @ Vr:
- 50 nA @ 23 V
- Voltage - Forward (Vf) (Max) @ If:
- 900 mV @ 10 mA
- Operating Temperature:
- 150°C (TJ)
- Grade:
- Automotive
- Qualification:
- AEC-Q101
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- DFN1006BD-2
PZU884LS-C30-QYL FAQ
1.How can I place an order for PZU884LS-C30-QYL through Aetrix?
Please submit a Request for Quotation (RFQ) for PZU884LS-C30-QYL on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for PZU884LS-C30-QYL reliable?
The price and inventory of PZU884LS-C30-QYL are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for PZU884LS-C30-QYL is usually 5 days.
3.What payment methods are accepted for PZU884LS-C30-QYL?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for PZU884LS-C30-QYL transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for PZU884LS-C30-QYL?
PZU884LS-C30-QYL orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your PZU884LS-C30-QYL order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for PZU884LS-C30-QYL?
For technical support, including PZU884LS-C30-QYL datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your PZU884LS-C30-QYL requirements.
6.How does Aetrix verify that PZU884LS-C30-QYL is sourced from the original manufacturer or authorized distributors?
All PZU884LS-C30-QYL products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that PZU884LS-C30-QYL meets industry standards.
7.What is the process for return or replacement of PZU884LS-C30-QYL?
All PZU884LS-C30-QYL units undergo pre-shipment inspection (PSI). If there is an issue with PZU884LS-C30-QYL, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The PZU884LS-C30-QYL part is unused and in its original packaging.
Return procedure for PZU884LS-C30-QYL:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
PZU884LS-C30-QYL Tags

-
MMBZ5240B-7-F
Diodes Incorporated

-
BZT52C5V6T-7
Diodes Incorporated

-
MMSZ5231B-7-F
Diodes Incorporated

-
BZT52C15-7-F
Diodes Incorporated

-
BZX84C3V3LT1G
onsemi

-
MMSZ5245BS-7-F
Diodes Incorporated

-
MMSZ4682T1G
onsemi

-
BZT52C15S-7-F
Diodes Incorporated

-
MM5Z5V1ST1G
onsemi

-
SMAJ4744A-TP
Micro Commercial Co

-
BZT52C3V6LP-7
Diodes Incorporated

-
SMAZ12-13-F
Diodes Incorporated
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…

