Analog Devices Inc. RAPID-NI-V2007
- Part No.:
- RAPID-NI-V2007
- Manufacturer:
- Analog Devices Inc.
- Category:
- Modules
- Package:
- Module
- Datasheet:
-
RAPID-NI-V2007.pdf
- Description:
- CNTRLLR ETHERNET IEEE 802.3 MOD
- Quantity:
- Payment:

- Shipping:

Inventory:3,960
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
RAPID-NI-V2007 from Innovasic is a pre-integrated network interface module with REM (Remote Enable/Disable) switch functionality, designed for industrial field devices requiring dual Ethernet port connectivity, embedded protocol stacks, and host processor interfacing via UART or 16-bit parallel bus. It integrates communications controller, Flash, RAM, PHYs, and isolated Ethernet line-side grounding in a 60.5 mm × 56.3 mm × 18.2 mm form factor, powered by a single +3.3 V supply and consuming ~1.8 W.
For engineers reviewing the RAPID-NI-V2007 datasheet, RAPID-NI-V2007 pinout, RAPID-NI-V2007 application, or RAPID-NI-V2007 equivalent, key selection considerations include its dual RJ45 Ethernet ports with Link/Activity LEDs, 64-pin 0.1" socket interface (SSW-116-21-F-D compatible), on-board TC1270A reset supervisor, and support for bootloader (.load), JTAG (.elf), and flash programmer (.srec) firmware updates.
Technical Context
The RAPID-NI-V2007 implements two independent Ethernet interfaces with integrated PHYs and line-side isolation, managed by an embedded fido® real-time OS and Unified Interface software stack. Its host communication supports either UART (TX/RX on X1-C3/C4) or 16-bit parallel FIFO interface (UIC0/UIC1 signals across X1-A/B/C/D rows), with dedicated control lines including FIFONOTEMPTY_N, WR_SEL_N, RD_SEL_N, and INT4.
Reset behavior is governed by the TC1270A voltage supervisor: MAN_RESET_N (X1-B8) accepts a low pulse ≥10 µs to initiate reset, while RESET_OUT_N (X1-B16) provides active-low status indication. Bootloader entry requires BOOTLOAD_EN_N (X1-B2) grounded at power-up, enabling field firmware updates over Ethernet without hardware rework.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Form Factor | 60.5 mm × 56.3 mm × 18.2 mm PCB module with edge-mounted RJ45 connectors and flush-mounted LEDs. |
| Power Supply | +3.3 V ±10% @ 800 mA; supplied via X1-B1 and X1-B9; total consumption ~1.8 W. |
| Host Interfaces | UART (2-wire TX/RX) or 16-bit parallel FIFO (read/write data + 4 control signals); both use 3.3 V logic. |
| Ethernet Ports | Dual 10/100BASE-TX RJ45 ports with integrated PHYs, Link/Activity LEDs inside connectors, and chassis ground (X1-C10) for line-side isolation. |
| Reset Architecture | TC1270A supervisor IC; manual reset via active-low MAN_RESET_N (X1-B8); status output RESET_OUT_N (X1-B16); 1.0 s initialization time post-reset or power-up. |
| Firmware Update Methods | Three supported: Ethernet bootloader (.load files), JTAG (.elf files via RapID-PGMR VMCGR), or flash programmer (.srec files). |
Availability
RAPID-NI-V2007 is available at Aetrix Electronics and suitable for industrial automation gateways, remote I/O systems, and field-deployed HMI controllers requiring stable component supply, long-term lifecycle support, and field-upgradable firmware.
Supply support for RAPID-NI-V2007 includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Innovasic, Inc. is a U.S.-based semiconductor company headquartered in Albuquerque, NM, specializing in deterministic real-time networking solutions for industrial and embedded applications.
The RAPID-NI-V2007 belongs to the RapID Platform family, engineered to accelerate development of interoperable, field-upgradable networked devices using standardized protocol stacks and modular hardware interfaces.
FAQ
What is the primary function of the RAPID-NI-V2007 in an industrial system?
The RAPID-NI-V2007 serves as a complete, drop-in network interface subsystem that enables field devices to connect to industrial Ethernet networks with minimal host processor overhead. It handles physical layer signaling, MAC-layer operations, protocol stack execution (including REM switch control), and firmware update management-allowing host microcontrollers to focus on application logic rather than low-level networking tasks. The RAPID-NI-V2007 integrates all required components: PHYs, Flash, RAM, and supervisor IC.
Does the RAPID-NI-V2007 support both UART and parallel host interfaces simultaneously?
No, the RAPID-NI-V2007 supports UART and parallel host interfaces as mutually exclusive configuration options-not concurrently. Signal multiplexing is implemented at the pin level: for example, UIC1_16 functions as UART TX in serial mode but as RD_SEL_N in parallel mode. Hardware design must select one interface type during board layout, and firmware must be configured accordingly. The RAPID-NI-V2007 does not auto-detect or dynamically switch between modes.
How is Ethernet port isolation implemented on the RAPID-NI-V2007?
Ethernet port isolation on the RAPID-NI-V2007 is achieved through line-side isolation referenced to chassis ground (X1-C10), physically separating the Ethernet PHY circuitry from the module's signal ground plane. This design meets industrial EMC requirements and prevents ground loops in distributed control systems. The RJ45 connectors extend 3.0 mm beyond the PCB edge to accommodate enclosure mounting while maintaining isolation integrity. The RAPID-NI-V2007 does not include transformer modules on-board; isolation is implemented externally in the connector assembly.
What are the critical timing requirements for asserting MAN_RESET_N on the RAPID-NI-V2007?
The MAN_RESET_N signal (X1-B8) must be held low for a minimum duration of 10 µs to guarantee reliable reset initiation by the on-board TC1270A supervisor IC. The signal is not 5 V tolerant and must be driven with a clean +3.3 V logic-level source. Reset assertion can occur at any time during operation, but the RAPID-NI-V2007 will not enter functional operation until 1.0 second after the reset pulse ends or after power stabilization if no external reset is applied.
Can the RAPID-NI-V2007 be programmed in-system without removing it from the target hardware?
Yes, the RAPID-NI-V2007 supports in-system programming via three methods: Ethernet-based bootloader (.load files), JTAG interface (.elf files using RapID-PGMR VMCGR), and flash programmer (.srec files). All methods operate while the module is installed in the end equipment. The bootloader method requires BOOTLOAD_EN_N (X1-B2) grounded at power-up; JTAG access uses a dedicated header shown in Figure 9; and flash programming targets the on-board SPI Flash directly. No disassembly or rework is needed for field updates.
RAPID-NI-V2007 Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Analog Devices Inc.
- Series:
- RapID™
- Package/Case:
- Module
- Packaging:
- Bulk
- Product Status:
- Obsolete
- Protocol:
- Ethernet
- Function:
- Controller
- Interface:
- UART
- Standards:
- IEEE 802.3
- Voltage - Supply:
- 3.3V
- Current - Supply:
- -
- Operating Temperature:
- -40°C ~ 85°C
- Supplier Device Package:
- Module
- Grade:
- -
- Qualification:
- -
RAPID-NI-V2007 FAQ
1.How can I place an order for RAPID-NI-V2007 through Aetrix?
Please submit a Request for Quotation (RFQ) for RAPID-NI-V2007 on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for RAPID-NI-V2007 reliable?
The price and inventory of RAPID-NI-V2007 are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for RAPID-NI-V2007 is usually 5 days.
3.What payment methods are accepted for RAPID-NI-V2007?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for RAPID-NI-V2007 transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for RAPID-NI-V2007?
RAPID-NI-V2007 orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your RAPID-NI-V2007 order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for RAPID-NI-V2007?
For technical support, including RAPID-NI-V2007 datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your RAPID-NI-V2007 requirements.
6.How does Aetrix verify that RAPID-NI-V2007 is sourced from the original manufacturer or authorized distributors?
All RAPID-NI-V2007 products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that RAPID-NI-V2007 meets industry standards.
7.What is the process for return or replacement of RAPID-NI-V2007?
All RAPID-NI-V2007 units undergo pre-shipment inspection (PSI). If there is an issue with RAPID-NI-V2007, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The RAPID-NI-V2007 part is unused and in its original packaging.
Return procedure for RAPID-NI-V2007:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
RAPID-NI-V2007 Tags

-
UMFT234XF
FTDI, Future Technology Devices International Ltd

-
ISL99227HRZ-T7A
Renesas Electronics Corporation

-
284
Adafruit Industries LLC

-
DEV-09716
SparkFun Electronics

-
DEV-09873
SparkFun Electronics

-
WIZ550IO
WIZnet

-
WIZ850IO
WIZnet

-
WIZ750SR-TTL
WIZnet

-
WIZ750SR-110
WIZnet

-
WIZ812MJ
WIZnet

-
WIZ810MJ
WIZnet

-
50020R-10
Renesas Electronics Corporation
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…