NXP Semiconductors RD-BESS1500-50H
- Part No.:
- RD-BESS1500-50H
- Manufacturer:
- NXP Semiconductors
- Category:
- Software, Services
- Package:
- Datasheet:
-
RD-BESS1500-50H.pdf
- Description:
- RD-BESS1500-50H
- Quantity:
- Payment:

- Shipping:

Inventory:1,875
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
RD-BESS1500-50H from NXP is an add-on engineering support package for the BESS 1.0 reference platform, delivering 50 hours of dedicated technical assistance for system integration, safety validation, and high-voltage BMS commissioning in utility-scale and industrial energy storage systems up to 1500 V d.c.
For engineers reviewing the RD-BESS1500-50H datasheet, RD-BESS1500-50H application, RD-BESS1500-50H equivalent, or RD-BESS1500-50H availability, this support add-on enables accelerated functional safety certification, BMU/CMU/BJB interface debugging, CAN FD and ETPL communication validation, and SIL 2-compliant runtime behavior verification.
Technical Context
RD-BESS1500-50H is not a hardware or software component but a time-bound engineering service bundle tied exclusively to the NXP BESS 1.0 reference design (BESS10FSA4 REV 1). It supports integration of the BMU, CMU Type 1/2, and BJB boards with MC33774/MC33772 analog front ends, FS26 system basis chip, and TPL gateway under IEC 61508 SIL 2 and IEC 60730 Class B requirements.
The 50-hour support scope includes configuration of production-ready MCAL drivers, lockstep core scheduler tuning, cell voltage/current synchronization alignment, isolation resistance measurement calibration, and GUI-based fault injection testing - all aligned to pre-certified safety documentation and daisy-chained CMU topology validation.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Support Duration | 50 hours of direct NXP engineering engagement for BESS 1.0 platform integration and safety validation. |
| Target Platform | NXP BESS 1.0 reference design (RD-BESS1500BUN + RD-BESSK358BMU + RDBESS774A3EVB + RDBESS772BJBEVB). |
| Safety Compliance Scope | Covers SIL 2 evidence generation per IEC 61508 Part 2 & 3 and Class B compliance per IEC 60730 Annex H. |
| Supported Interfaces | CAN FD, isolated ETPL, RS-485 (Modbus), Ethernet, and PWM-based interlock pilot loop diagnostics. |
| Measurement Validation | Includes calibration support for ±500 A redundant shunt/Hall current sensing, 6-channel HV measurement, and thermal runaway pressure sensor response. |
Availability
RD-BESS1500-50H is available at Aetrix Electronics and suitable for utility front-of-the-meter (FTM) deployments, commercial battery energy storage commissioning, residential 1500 V d.c. system qualification, and grid-scale renewable integration projects requiring stable component supply and certified engineering support.
Supply support for RD-BESS1500-50H includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
NXP Semiconductors is a global semiconductor company headquartered in Eindhoven, Netherlands, specializing in secure connectivity solutions for automotive, industrial, IoT, and power management applications.
RD-BESS1500-50H belongs to NXP's Battery Energy Storage System (BESS) 1.0 product line, designed to accelerate development of high-voltage, functionally safe BMS platforms compliant with IEC 61508 SIL 2 and IEC 60730 Class B for utility, C&I, and residential energy storage.
FAQ
What is RD-BESS1500-50H and how does it differ from hardware reference boards like RD-BESS1500BUN?
RD-BESS1500-50H is a 50-hour engineering support add-on, not a physical board. Unlike RD-BESS1500BUN (which contains BMU, CMU3, and BJB hardware), RD-BESS1500-50H provides dedicated NXP engineer time for safety validation, interface debugging, and SIL 2 evidence generation specific to the BESS 1.0 platform.
Does RD-BESS1500-50H include software licenses or firmware binaries?
No. RD-BESS1500-50H delivers only human engineering support hours. All software-including production-ready MCAL drivers, safety libraries, and GUI-is provided separately with RD-BESS1500BUN or RD-BESS1-PREM. RD-BESS1500-50H does not grant additional software rights or redistribution permissions.
Can RD-BESS1500-50H be applied to non-NXP BMS hardware or third-party battery modules?
No. RD-BESS1500-50H is contractually and technically scoped to the NXP BESS 1.0 reference design (document BESS10FSA4 REV 1) using specified components: MC33774/MC33772, FS26, and TPL gateway. Support does not extend to custom PCBs, alternate analog front ends, or non-daisy-chained CMU topologies.
Is RD-BESS1500-50H required to achieve IEC 61508 SIL 2 certification?
RD-BESS1500-50H is not mandatory for certification but accelerates it by providing expert guidance on safety analysis, fault injection testing, scheduler time-slot monitoring, and lockstep core validation-tasks otherwise performed internally or via external consultants. The BESS 1.0 platform itself is pre-analyzed to SIL 2 level; RD-BESS1500-50H helps apply that analysis to your specific implementation.
How is RD-BESS1500-50H delivered and tracked during engagement?
RD-BESS1500-50H is delivered as a time-bound service agreement with scheduled remote or on-site sessions coordinated via NXP's engineering support portal. Each hour is logged against defined deliverables: interface validation reports, safety parameter configuration records, ETPL timing analysis, and GUI-based diagnostic test logs-all traceable to RD-BESS1500-50H order fulfillment.
RD-BESS1500-50H Specifications
- Product attributes
- Attribute value
- Manufacturer:
- NXP Semiconductors
- Series:
- -
- Packaging:
- Bulk
- Product Status:
- Active
- Type:
- -
- Applications:
- -
- Edition:
- -
- License Length:
- -
- License - User Details:
- -
- Operating System:
- -
- For Use With/Related Products:
- -
- Media Delivery Type:
- -
RD-BESS1500-50H FAQ
1.How can I place an order for RD-BESS1500-50H through Aetrix?
Please submit a Request for Quotation (RFQ) for RD-BESS1500-50H on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for RD-BESS1500-50H reliable?
The price and inventory of RD-BESS1500-50H are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for RD-BESS1500-50H is usually 5 days.
3.What payment methods are accepted for RD-BESS1500-50H?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for RD-BESS1500-50H transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for RD-BESS1500-50H?
RD-BESS1500-50H orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your RD-BESS1500-50H order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for RD-BESS1500-50H?
For technical support, including RD-BESS1500-50H datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your RD-BESS1500-50H requirements.
6.How does Aetrix verify that RD-BESS1500-50H is sourced from the original manufacturer or authorized distributors?
All RD-BESS1500-50H products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that RD-BESS1500-50H meets industry standards.
7.What is the process for return or replacement of RD-BESS1500-50H?
All RD-BESS1500-50H units undergo pre-shipment inspection (PSI). If there is an issue with RD-BESS1500-50H, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The RD-BESS1500-50H part is unused and in its original packaging.
Return procedure for RD-BESS1500-50H:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
RD-BESS1500-50H Tags
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…





