Overview
RI-TRP-W9QL-30 from Texas Instruments is a 30 mm disk-shaped, batteryless LF RFID transponder operating at 134.2 kHz with HDX (Half Duplex) transmission, ISO 11784/11785 compliance, 80-bit read/write memory, and IP67-rated POM housing. It delivers stable read/write performance in vehicle identification, container tracking, and waste management systems where non-metallic material penetration and environmental ruggedness are required.
For engineers reviewing the RI-TRP-W9QL-30 datasheet, RI-TRP-W9QL-30 pinout, RI-TRP-W9QL-30 application, or RI-TRP-W9QL-30 equivalent, key selection considerations include its HDX modulation scheme, 30% programming range relative to reading range, 100,000-programming-cycle endurance, and operational limits of –25°C to +70°C in harsh industrial environments.
Technical Context
This transponder uses patented TI tuning technology to ensure consistent resonance and coupling efficiency across production units. Its HDX architecture enables simultaneous reader-to-transponder power transfer and transponder-to-reader data transmission via FSK (134.2 kHz / 123.2 kHz), eliminating need for onboard power.
It operates exclusively in the low-frequency band and relies on magnetic field coupling - not RF radiation - making it insensitive to most non-metallic materials and compliant with global animal and asset identification standards. No internal oscillator or clock circuitry is present; timing is fully synchronized to the reader's carrier field.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Operating Frequency | 134.2 kHz - defines magnetic coupling bandwidth and regulatory compliance for global LF RFID systems |
| Memory Capacity | 80-bit read/write - supports 64 user bits + 16-bit CRC per TI-RFid™LF reader convention |
| Transmission Principle | HDX (Half Duplex) - enables reliable backscatter communication without internal clock or battery |
| Reading Range | ≤60 cm - highly dependent on reader antenna design and local RF regulations, not device-limited |
| Programming Cycles | 100,000 @ 25°C - specifies endurance for repeated field-based reprogramming in asset lifecycle management |
| Operating Temperature | –25°C to +70°C - validated thermal range for outdoor and industrial deployment including waste collection vehicles |
| Protection Rating | IP67 - ensures dust-tight and immersion-resistant operation in wet, dirty, or high-vibration environments |
Pinout & Package
RI-TRP-W9QL-30 is a passive, two-terminal resonant LC device with no electrical pins or solderable terminals. It consists of a tuned coil-capacitor assembly embedded in a molded Poly-Oxy-Methylen (POM) disk (29.4 mm × 8.4 mm, 8 g), sealed to IP67. No external connections are required - coupling occurs wirelessly via magnetic field induction.
Key Features
| Feature | Design Value |
|---|---|
| Patented Transponder Tuning | Ensures consistent resonance frequency and impedance matching across production lots, reducing reader calibration burden |
| HDX Technology | Enables full-duplex-equivalent bidirectional communication using single-carrier magnetic coupling, avoiding timing drift issues of asynchronous protocols |
| ISO 11784/11785 Compliance | Guarantees interoperability with globally deployed LF readers used in livestock, vehicle, and municipal ID infrastructure |
| Non-Metallic Material Penetration | Allows reliable read-through of plastic, rubber, concrete, wood, and soil - critical for embedded or buried asset tagging |
| IEC 68-2 Shock/Vibration Rated | Validated for 1500 g shock and 25 g vibration exposure - suitable for mounting on moving assets like containers and refuse trucks |
Applications
| Vehicle Identification | Container Tracking |
|---|---|
Use Scenario: Mounted on truck chassis or trailer frames for automated gate access and fleet logging in logistics yards. IC Role / Device Role / Timing Role: Passive responder providing unique 80-bit identity under magnetic field excitation; no timing source required. Use Value: Enables contactless, weatherproof identification without batteries or wiring - reducing maintenance in high-vibration transport environments. | Use Scenario: Embedded in ISO shipping containers for port-side inventory reconciliation and customs verification. IC Role / Device Role / Timing Role: Read/write tag storing container ID, seal status, and last inspection timestamp via handheld or gantry-mounted readers. Use Value: Supports tamper-evident, field-updatable records with CRC-protected memory - meeting maritime and customs traceability requirements. |
| Asset Management | Waste Management |
Use Scenario: Affixed to high-value tools, generators, or construction equipment for yard-level check-in/check-out and theft deterrence. IC Role / Device Role / Timing Role: Batteryless memory node storing serialized ID and maintenance history; powered only during interrogation. Use Value: Eliminates battery replacement cycles and extends service life beyond 10 years in unattended deployments. | Use Scenario: Installed inside underground waste bins or compactors to log fill level, collection frequency, and route optimization data. IC Role / Device Role / Timing Role: Ruggedized transponder surviving compaction forces and moisture exposure while retaining programmable payload. Use Value: Withstands IP67 conditions and 1500 g mechanical shock - enabling reliable data capture in municipal solid waste infrastructure. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar passive LF RFID transponder applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| RI-TRP-R9QL-30 | 64-bit read-only memory; no write capability; same HDX, ISO 11784/11785, and mechanical specs | Suitable only for fixed-ID use cases (e.g., animal ear tags), not for field-updatable asset records | Select when write endurance, CRC validation, or dynamic data storage is unnecessary |
| EM4102 (from EM Microelectronic) | Read-only, 128-bit ROM; uses FDX-B protocol (not HDX); different modulation and timing; smaller 23 mm form factor | Limited to legacy FDX-B readers; lacks HDX's noise immunity and longer-range potential in noisy industrial settings | Choose only for backward compatibility with installed FDX-B infrastructure; not drop-in compatible |
Compared with RI-TRP-R9QL-30 and EM4102, the RI-TRP-W9QL-30 uniquely supports field-programmable 80-bit payloads with CRC protection and HDX's superior noise rejection - making it the only option among the three for updatable, high-integrity industrial asset tagging requiring ISO 11784/11785 compliance.
Availability
RI-TRP-W9QL-30 is available at Aetrix Electronics and suitable for vehicle identification, container tracking, and waste management applications requiring stable component supply, long-term lifecycle support, and RoHS-compliant passive RFID components.
Supply support for RI-TRP-W9QL-30 includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Texas Instruments is a global semiconductor company specializing in analog, embedded processing, and connectivity technologies, with leadership in industrial, automotive, and sensing solutions.
The RI-TRP-W9QL-30 belongs to TI's legacy LF RFID transponder product line, engineered specifically for rugged, batteryless identification in demanding physical environments - including municipal, transportation, and logistics infrastructure.
FAQ
What is the memory structure of the RI-TRP-W9QL-30?
The RI-TRP-W9QL-30 contains 80 bits of EEPROM organized as one page. TI recommends allocating 64 bits for user data and 16 bits for a CCITT CRC block check character. This structure ensures data integrity during wireless programming and is enforced by TI-RFid™LF readers - the RI-TRP-W9QL-30 itself does not validate CRC but stores it as written.
Does the RI-TRP-W9QL-30 require a battery or external power source?
No, the RI-TRP-W9QL-30 is entirely batteryless and derives all operating energy from the reader's magnetic field via inductive coupling. Its HDX architecture enables both power harvesting and backscatter communication without any onboard voltage regulator, oscillator, or power storage - a defining feature of the RI-TRP-W9QL-30 design.
What is the maximum programming distance for the RI-TRP-W9QL-30?
The typical programming distance for the RI-TRP-W9QL-30 is 30% of its specified reading range - approximately ≤18 cm under standard test conditions. Actual distance varies with reader antenna size, coil geometry, field strength, and local regulatory limits on magnetic field emissions, as stated in the official RI-TRP-W9QL-30 datasheet.
Is the RI-TRP-W9QL-30 suitable for outdoor or submerged installations?
Yes - the RI-TRP-W9QL-30 features an IP67-rated POM housing and passes IEC 68-2 mechanical shock and vibration tests. It is certified for continuous operation from –25°C to +70°C and withstands immersion up to 1 m for 30 minutes, making it appropriate for outdoor, underground, or washdown environments where the RI-TRP-W9QL-30 remains fully functional.
How does HDX differ from FDX-B in the context of the RI-TRP-W9QL-30?
HDX (Half Duplex) used by the RI-TRP-W9QL-30 separates reader transmission and transponder reply in time, using FSK at 134.2 kHz / 123.2 kHz. Unlike FDX-B, HDX provides higher noise immunity, longer effective range, and deterministic timing - critical for reliable operation in electrically noisy industrial sites where the RI-TRP-W9QL-30 is commonly deployed.
RI-TRP-W9QL-30 Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Texas Instruments
- Series:
- -
- Packaging:
- Bulk
- Product Status:
- Obsolete
- Style:
- Encapsulated
- Technology:
- Passive
- Frequency:
- 134.2kHz
- Memory Type:
- Read/Write
- Writable Memory:
- 80b (User)
- Standards:
- ISO 11784, ISO 11785
- Operating Temperature:
- -25°C ~ 70°C
- Size / Dimension:
- 29.40mm Dia x 8.40mm
RI-TRP-W9QL-30 FAQ
1.How can I place an order for RI-TRP-W9QL-30 through Aetrix?
Please submit a Request for Quotation (RFQ) for RI-TRP-W9QL-30 on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for RI-TRP-W9QL-30 reliable?
The price and inventory of RI-TRP-W9QL-30 are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for RI-TRP-W9QL-30 is usually 5 days.
3.What payment methods are accepted for RI-TRP-W9QL-30?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for RI-TRP-W9QL-30 transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for RI-TRP-W9QL-30?
RI-TRP-W9QL-30 orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your RI-TRP-W9QL-30 order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for RI-TRP-W9QL-30?
For technical support, including RI-TRP-W9QL-30 datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your RI-TRP-W9QL-30 requirements.
6.How does Aetrix verify that RI-TRP-W9QL-30 is sourced from the original manufacturer or authorized distributors?
All RI-TRP-W9QL-30 products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that RI-TRP-W9QL-30 meets industry standards.
7.What is the process for return or replacement of RI-TRP-W9QL-30?
All RI-TRP-W9QL-30 units undergo pre-shipment inspection (PSI). If there is an issue with RI-TRP-W9QL-30, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The RI-TRP-W9QL-30 part is unused and in its original packaging.
Return procedure for RI-TRP-W9QL-30:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
RI-TRP-W9QL-30 Tags

-
SL3S1013FTB0,115
NXP Semiconductors

-
NTP53321G0JHKZ
NXP Semiconductors
-
HTSH4801ETK,118
NXP Semiconductors

-
NTA53321G0FHKZ
NXP Semiconductors

-
RF-HDT-DVBE-N2
Texas Instruments
-
RF-HDT-DVBB-N2
Texas Instruments

-
HT2DC20S20/F/RSP
NXP Semiconductors

-
TRPGR30ATGA
Texas Instruments
-
TRPGR30ATGC
Texas Instruments

-
RI-TRP-DR2B-40
Texas Instruments

-
V680-D1KP52MT
Omron Automation and Safety

-
HTMS8001FTB/AF,115
NXP USA Inc.
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…