Skyworks Solutions Inc. SI83414ACA-IF

Part No.:
SI83414ACA-IF
Manufacturer:
Skyworks Solutions Inc.
Category:
Digital Isolators
Package:
32-VFDFN Exposed Pad
Datasheet:
AetrixSI83414ACA-IF.pdf
Description:
LINEAR IC'S
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:2,102

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

SI83414ACA-IF from Skyworks Solutions is a quad-channel isolated smart switch configured as low-side, open-drain drivers with 0.7 A continuous current per channel, 155 mΩ RON, and integrated fault protection including inrush current mode (8 A for 20 ms) and open-channel detection. It targets industrial PLC output modules driving solenoids and relays under 9–32 V supply rails.

For engineers reviewing the SI83414ACA-IF datasheet, SI83414ACA-IF pinout, SI83414ACA-IF application, or SI83414ACA-IF equivalent, key selection considerations include its dedicated open-drain low-side topology, VDD2_WRN undervoltage warning pin, open-channel indicator (OPEN_CH), and absence of SPI interface - requiring parallel control only with asynchronous OE enable.

Technical Context

The SI83414ACA-IF implements four galvanically isolated low-side switches using Skyworks' CMOS-based RF isolation barrier, delivering >100 kV/µs CMTI and 1.5 kVRMS safety rating. Each channel integrates voltage, current, and temperature sensing with autonomous protection logic.

It operates with dual supplies: logic side (VDD1 = 2.25–5.5 V) and power side (VDD2 = 9–32 V), and features fixed-function parallel interface with no SPI - diagnostics are exposed via dedicated pins: VDD2_WRN, FLT, and OPEN_CH, all active-low open-drain outputs.

Key Specifications

ParameterValue and Actual Design Meaning
Switch TypeLow-side, open-drain configuration - sinks load current to GND2; requires external pull-up for driven loads.
Continuous Current0.7 A per channel - supports solenoids, relays, and lamps at full rated load without derating up to 125 °C.
RON155 mΩ max - minimizes conduction loss and self-heating during sustained operation.
Inrush Current Mode8 A for 20 ms - enables reliable cold-start of incandescent lamps without tripping overcurrent protection.
Isolation Rating1.5 kVRMS for 1 min - certified to UL 1577, CSA 62368-1, and GB4943.1 for functional safety in industrial environments.
CMTI>100 kV/µs - ensures robust noise immunity in electrically noisy PLC backplanes and motor drive cabinets.
Operating Temp−40 °C to +125 °C - qualified for extended industrial ambient and PCB self-heating conditions.

Pinout & Package

SI83414ACA-IF is housed in a compact 9 mm × 9 mm DFN-32 package with exposed thermal pad (EP), optimized for high-density industrial PCB layouts and thermal dissipation under continuous 0.7 A/channel load.

Pin/TerminalCircuit RoleDesign Meaning
VDD1Logic Supply Input2.25–5.5 V digital supply powering input interface and isolation transmitter; powers internal logic even when VDD2 is off via diode coupling.
OEAsynchronous Output EnableActive-high global enable - disables all four Bn outputs immediately when pulled low; overrides individual channel inputs.
GND1Logic GroundReference for VDD1 and all digital inputs; must be separated from GND2 by ≥8 mm creepage/clearance.
GND2Power GroundReturn path for all four Bn switch currents; connects directly to load return and VDD2 decoupling.
VDD2Switch Supply Input9–32 V analog supply powering output stage; monitored for undervoltage warning (VDD2_WRN) and fault shutdown.
A1–A4Parallel Input ChannelsActive-high logic inputs controlling B1–B4 outputs respectively; compatible with 2.25 V MCU GPIOs.
B1–B4Low-Side Switch OutputsOpen-drain N-channel MOSFET drains - sink current to GND2; require external pull-up to VDD2 or separate rail.
VDD2_WRNSupply Warning IndicatorActive-low open-drain output asserted when VDD2 drops below warning threshold (VDD2UV9); used for system-level brown-out alert.
OPEN_CHOpen-Channel DetectorActive-low open-drain output asserted when any Bn output is open-circuit (no load or broken wire); enables predictive maintenance.
FLTFault IndicatorActive-low open-drain output asserted on any detected fault (overcurrent, overtemperature, VDD1/VDD2 UV/OV); latched until cleared by power cycle.
DNC / NCNo-ConnectUnbonded pins - must be left floating or tied to GND2 per layout guidelines; no electrical function.

Key Features

FeatureDesign Value
Quad Low-Side SwitchingFour independent 0.7 A, 155 mΩ open-drain outputs with autonomous thermal/current limiting - eliminates need for external sense resistors or discrete protection.
Inrush Current Mode8 A peak for 20 ms per channel - sustains lamp filament preheat without triggering overcurrent shutdown, verified across temperature and supply range.
Open-Channel DetectionDedicated OPEN_CH pin reports open-load condition on any channel - enables real-time wiring integrity monitoring in safety-critical I/O modules.
VDD2 Undervoltage WarningVDD2_WRN pin asserts before fault shutdown - provides early warning of marginal power rail, allowing host controller to initiate graceful shutdown or alarm.
CMOS RF Isolation1.5 kVRMS isolation with >100 kV/µs CMTI - replaces optocouplers with higher reliability, longer lifetime, and no LED aging or CTR degradation.

Applications

Programmable Logic Controllers (PLCs)Industrial Data Acquisition Systems

Use Scenario: Digital output module in modular PLC rack driving 24 V DC solenoid valves and relay coils in factory automation lines.

IC Role / Device Role / Timing Role: Low-side switch providing isolated, protected, and diagnosed load control with <10 µs update rate and open-wire detection.

Use Value: Eliminates external flyback diodes and current-sense circuits while enabling predictive maintenance via OPEN_CH and VDD2_WRN alerts.

Use Scenario: Remote I/O node collecting sensor actuation commands from central controller in hazardous-area process monitoring systems.

IC Role / Device Role / Timing Role: Galvanically isolated output driver ensuring signal integrity across ground potential differences between field and control room.

Use Value: Delivers >100 kV/µs transient immunity and 1.5 kVRMS isolation to meet IEC 61131-2 requirements for industrial communication networks.

Smart Solid-State RelaysMotion Control I/O Modules

Use Scenario: Compact DIN-rail mounted SSR replacing electromechanical relays in HVAC and packaging machinery control panels.

IC Role / Device Role / Timing Role: Quad low-side driver with inrush mode supporting incandescent pilot lights and small AC contactor coils via DC interface.

Use Value: Enables silent, bounce-free switching with 8 A inrush capability and built-in demagnetization clamp - extends contactor life and reduces EMI.

Use Scenario: Axis-specific enable/disable output in multi-axis servo drive cabinet, controlling brake release and safety interlocks.

IC Role / Device Role / Timing Role: Fault-monitored switch providing fail-safe de-energization with FLT and OPEN_CH feedback to motion controller.

Use Value: Supports SIL-2 functional safety architecture by reporting open-circuit faults and supply warnings before catastrophic failure occurs.

Equivalent & Alternatives

The following parts are listed as comparable options for similar low-side isolated switch applications.

Alternative PartTechnical DifferenceApplication DifferenceSelection Advice
SI83414BBA-IFNo OPEN_CH or VDD2_WRN pins; identical 4-channel low-side, 0.7 A, 155 mΩ, parallel-only interface.Lacks open-channel and supply warning diagnostics - suitable only where wiring integrity monitoring is not required.Select when cost optimization is prioritized over predictive maintenance capability and system-level power rail monitoring.
SI83414ABA-IFIncludes OPEN_CH and VDD2_WRN pins like SI83414ACA-IF, but adds LEDn status indicators (LED1–LED4) for per-channel visual feedback.Provides per-channel status indication via open-drain LEDs - useful for front-panel diagnostics in human-accessible equipment.Select when local operator visibility of channel states is required alongside open-wire and supply warning detection.

Compared with SI83414BBA-IF, SI83414ACA-IF adds critical open-circuit and supply warning diagnostics without increasing pin count or complexity; versus SI83414ABA-IF, it trades per-channel LED indicators for lower BOM cost and simpler layout where visual feedback is unnecessary.

Availability

SI83414ACA-IF is available at Aetrix Electronics and suitable for industrial programmable logic controllers, smart solid-state relays, and motion control I/O modules requiring stable component supply, long-term lifecycle assurance, and certified isolation performance.

Supply support for SI83414ACA-IF includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

Skyworks Solutions is a U.S.-based semiconductor company specializing in analog and mixed-signal connectivity solutions for infrastructure, automotive, and industrial markets.

The Si834x product line was designed specifically for industrial digital output modules, replacing legacy optocoupler-plus-driver designs with integrated, isolated, and self-protecting smart switches compliant to IEC 61131-2 and safety standards.

FAQ

What is the switch configuration of SI83414ACA-IF?

The SI83414ACA-IF is a quad-channel low-side, open-drain switch - each Bn output sinks current to GND2 and requires an external pull-up to VDD2 or another supply rail. It does not support high-side sourcing, and its A1–A4 inputs are active-high parallel controls with global OE enable. This configuration is optimized for driving solenoids, relays, and lamps in industrial I/O modules.

Does SI83414ACA-IF support SPI communication?

No, SI83414ACA-IF does not support SPI communication. It uses a parallel-only interface with A1–A4 inputs and OE control. Diagnostics are reported exclusively through dedicated pins: FLT (fault), VDD2_WRN (supply warning), and OPEN_CH (open-channel). For SPI-enabled variants, consider SI83418BDA-IF or SI83418ADA-IF.

What diagnostic functions are available on SI83414ACA-IF?

SI83414ACA-IF provides three hardware-diagnostic outputs: FLT (active-low fault indicator), VDD2_WRN (active-low undervoltage warning), and OPEN_CH (active-low open-channel detector). These pins report aggregated conditions across all four channels and require no software polling - enabling immediate system-level response to supply issues or broken wiring without MCU intervention.

What is the purpose of the OPEN_CH pin on SI83414ACA-IF?

The OPEN_CH pin on SI83414ACA-IF is an active-low, open-drain output that asserts when any of the four Bn outputs detects an open-circuit load - such as a disconnected wire, blown fuse, or failed solenoid coil. This enables real-time wiring integrity verification in safety-critical applications like PLC output modules, eliminating the need for external continuity testing circuitry.

How does the inrush current mode work in SI83414ACA-IF?

The inrush current mode in SI83414ACA-IF delivers up to 8 A peak current for 20 ms per channel during initial turn-on - specifically engineered to preheat incandescent lamp filaments without triggering overcurrent protection. This feature is automatic, requires no configuration, and operates independently of load resistance or temperature, ensuring reliable cold-start behavior across the full −40 °C to +125 °C operating range.

SI83414ACA-IF Specifications

Product attributes
Attribute value
Manufacturer:
Skyworks Solutions Inc.
Series:
-
Package/Case:
32-VFDFN Exposed Pad
Packaging:
Tray
Product Status:
Active
Technology:
Capacitive Coupling
Type:
SPI
Isolated Power:
Yes
Number of Channels:
4
Inputs - Side 1/Side 2:
4/0
Channel Type:
Unidirectional
Voltage - Isolation:
1500Vrms
Common Mode Transient Immunity (Min):
100kV/µs
Data Rate:
-
Propagation Delay tpLH / tpHL (Max):
3.7µs, 3.7µs
Pulse Width Distortion (Max):
-
Rise / Fall Time (Typ):
-, 3µs
Voltage - Supply:
2.25V ~ 5.5V, 9V ~ 32V
Grade:
-
Qualification:
-
Operating Temperature:
-40°C ~ 125°C
Mounting Type:
Surface Mount
Supplier Device Package:
32-DFN (9x9)

SI83414ACA-IF FAQ

1.How can I place an order for SI83414ACA-IF through Aetrix?

Please submit a Request for Quotation (RFQ) for SI83414ACA-IF on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for SI83414ACA-IF reliable?

The price and inventory of SI83414ACA-IF are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for SI83414ACA-IF is usually 5 days.

3.What payment methods are accepted for SI83414ACA-IF?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for SI83414ACA-IF transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for SI83414ACA-IF?

SI83414ACA-IF orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your SI83414ACA-IF order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for SI83414ACA-IF?

For technical support, including SI83414ACA-IF datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your SI83414ACA-IF requirements.

6.How does Aetrix verify that SI83414ACA-IF is sourced from the original manufacturer or authorized distributors?

All SI83414ACA-IF products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that SI83414ACA-IF meets industry standards.

7.What is the process for return or replacement of SI83414ACA-IF?

All SI83414ACA-IF units undergo pre-shipment inspection (PSI). If there is an issue with SI83414ACA-IF, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The SI83414ACA-IF part is unused and in its original packaging.

Return procedure for SI83414ACA-IF:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

SI83414ACA-IF Tags

  • SI83414ACA-IF
  • SI83414ACA-IF PDF
  • SI83414ACA-IF Datasheet
  • SI83414ACA-IF Specifications
  • SI83414ACA-IF Images
  • Skyworks Solutions Inc.
  • Skyworks Solutions Inc. SI83414ACA-IF
  • Buy SI83414ACA-IF
  • SI83414ACA-IF Price
  • SI83414ACA-IF Distributor
  • SI83414ACA-IF Supplier
  • SI83414ACA-IF Wholesale
Related Products
ISO1212DBQR
ISO1212DBQR

Texas Instruments

ISO6721BDR
ISO6721BDR

Texas Instruments

SI8710AC-B-ISR
SI8710AC-B-ISR

Skyworks Solutions Inc.

ISO7720FDR
ISO7720FDR

Texas Instruments

ISO7721DR
ISO7721DR

Texas Instruments

ISO7721FDR
ISO7721FDR

Texas Instruments

SI8710CC-B-ISR
SI8710CC-B-ISR

Skyworks Solutions Inc.

ISO6741FQDWRQ1
ISO6741FQDWRQ1

Texas Instruments

ISO7721DWVR
ISO7721DWVR

Texas Instruments

ISO7762FDBQR
ISO7762FDBQR

Texas Instruments

ISO7741DWR
ISO7741DWR

Texas Instruments

ISO7741FDWR
ISO7741FDWR

Texas Instruments

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER