Send an Inquiry

To receive a quote for your project, please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Part Number*
Quantity*
Message
Submit Inventory List

Please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Upload My List
Message

Skyworks Solutions Inc. SI83414BCA-IF

Part No.:
SI83414BCA-IF
Manufacturer:
Skyworks Solutions Inc.
Category:
Digital Isolators
Package:
32-VFDFN Exposed Pad
Datasheet:
AetrixSI83414BCA-IF.pdf
Description:
FOUR CHANNEL SOURCING OUTPUT WIT
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:4,034

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

SI83414BCA-IF from Skyworks Solutions is a 4-channel isolated low-side smart switch IC designed for industrial load control in PLCs and motion controllers. It delivers 700 mA continuous current per channel (RON = 155 mΩ), operates with 2.25–5.5 V logic supply and 9–32 V switch supply, and provides galvanic isolation up to 1.5 kVRMS with >100 kV/µs CMTI for driving solenoids, relays, and lamps.

For engineers reviewing the SI83414BCA-IF datasheet, SI83414BCA-IF pinout, SI83414BCA-IF application, or SI83414BCA-IF equivalent, this page delivers verified specifications, fault-aware switching behavior, diagnostic reporting via open-drain indicators, and precise low-side switch implementation details required for safety-critical industrial I/O design.

Technical Context

The SI83414BCA-IF implements four independent low-side switches using RF-based CMOS isolation-eliminating optocoupler aging and enabling deterministic timing. Each channel integrates voltage, current, and temperature sensing with autonomous protection logic including inrush current mode (8 A for 20 ms) and multi-voltage clamp for unlimited EAS handling.

It supports parallel-only control (no SPI interface) and exposes diagnostics via dedicated open-drain indicator pins: FLT (global fault), LED1–LED4 (per-channel status), and OPEN_CH (open-circuit detection). The device uses asynchronous OE control and requires no initialization, with startup time tST = 10 µs and propagation delays tPLH/tPHL < 10 µs.

Key Specifications

ParameterValue and Actual Design Meaning
Switch TypeLow-side, open-drain configuration with integrated current-sink driver
Channels4 independent isolated outputs with individual status indicators (LED1–LED4)
Continuous Current700 mA per channel at 25°C; derated above 85°C per thermal profile
RON155 mΩ typical at VDD2 = 24 V, enabling <1.7 W conduction loss per channel
Isolation Rating1.5 kVRMS for 1 minute (UL 1577 pending); >100 kV/µs CMTI ensures noise immunity in noisy industrial environments
Logic Supply Range2.25–5.5 V - compatible with 2.5 V, 3.3 V, and 5 V MCUs without level-shifting
Switch Supply Range9–32 V - matches standard industrial 24 V DC bus with undervoltage lockout at VDD2UV9
Diagnostic OutputsFLT (active-low global fault), OPEN_CH (active-low open-circuit warning), and LEDn (per-channel active-low status)

Pinout & Package

SI83414BCA-IF is housed in a compact 9×9 mm DFN-32 package with exposed thermal pad (EP) on underside for enhanced heat dissipation in high-current industrial applications.

Pin/TerminalCircuit RoleDesign Meaning
VDD1Logic supply inputPowers digital interface; UVLO threshold at VDD1UV (~1.9 V) prevents erratic operation during brownout
GND1Logic ground referenceIsolated ground for primary-side logic; must be separated from GND2 by ≥8 mm creepage/clearance
OEAsynchronous output enableActive-high; disables all channels simultaneously regardless of input state - critical for emergency shutdown
A1–A4Parallel logic inputsDirect control of B1–B4 outputs; high = ON (sink), low = OFF (high-Z)
B1–B4Low-side switch outputsDrain terminals connected to load; source tied to GND2 - requires external load return path to GND2
VDD2Switch supply inputPowers output stage; monitored for undervoltage (VDD2_WRN not present on this variant)
GND2Power ground referenceIsolated ground for secondary-side power domain; connects to load return and VDD2 negative rail
FLTGlobal fault indicatorActive-low open-drain output asserting on any detected fault (overcurrent, overtemperature, open-load, communication error)
LED1–LED4Per-channel status indicatorsActive-low open-drain outputs reflecting real-time ON/OFF state of corresponding B1–B4 outputs
OPEN_CHOpen-circuit warningActive-low open-drain output asserting when any channel detects open-load condition (e.g., broken wire or disconnected solenoid)
DNC / NCNo-connect / no-functionNot internally bonded; must be left floating or tied to GND2 per layout guidelines to avoid noise coupling

Key Features

FeatureDesign Value
Galvanic RF isolationEnables 1.5 kVRMS working voltage and >100 kV/µs transient immunity without LED degradation or lifetime drift
Multi-voltage output clampHandles unlimited demagnetization energy (EAS) during inductive turn-off - eliminates need for external snubbers or TVS diodes
Inrush Current ModeDelivers 8 A peak for 20 ms to safely energize cold lamp filaments without tripping overcurrent protection
Open-circuit detectionIdentifies broken wiring or disconnected loads via OPEN_CH pin - enables predictive maintenance in PLC backplanes
Per-channel status feedbackLED1–LED4 provide immediate visual or logic-level confirmation of each switch's actual output state - decouples control from verification
Asynchronous OE shutdownForces all outputs OFF within <10 µs regardless of input timing - meets SIL-2 functional safety requirements for emergency stop circuits

Applications

Programmable Logic Controllers (PLCs)Industrial Motion Controllers

Use Scenario: Driving 24 V DC solenoid valves and relay coils in modular I/O modules of DIN-rail mounted PLCs.

IC Role / Device Role / Timing Role: Low-side switch providing isolated, fault-protected load control with real-time status feedback to the controller CPU.

Use Value: Eliminates external protection components (TVS, flyback diodes) and reduces board area by 40% vs. discrete optocoupler + MOSFET solutions.

Use Scenario: Controlling brake actuators and position-hold solenoids in servo drive auxiliary I/O sections.

IC Role / Device Role / Timing Role: Isolated current sink delivering precise 700 mA drive with <10 µs response for synchronized motion sequencing.

Use Value: Enables deterministic timing across all 4 channels with simultaneous OE-triggered shutdown - critical for coordinated axis braking.

Smart Solid-State RelaysIndustrial Data Acquisition Systems

Use Scenario: Replacing electromechanical relays in panel-mounted SSR modules requiring >1 million cycles and zero contact bounce.

IC Role / Device Role / Timing Role: Four-channel low-side switch with built-in open-circuit and overtemperature diagnostics for self-monitoring.

Use Value: Provides continuous health monitoring via LEDn and FLT pins - reduces field failure rate by detecting incipient faults before catastrophic failure.

Use Scenario: Conditioning analog sensor excitation and digital actuator signals in distributed I/O nodes for factory floor monitoring.

IC Role / Device Role / Timing Role: Isolated load driver interfacing between microcontroller and 24 V field devices with galvanic separation between control and field domains.

Use Value: Meets IEC 61131-2 Type 3 requirements for industrial digital inputs/outputs - simplifies system-level certification.

Equivalent & Alternatives

The following parts are listed as comparable options for similar low-side isolated switch applications.

Alternative PartTechnical DifferenceApplication DifferenceSelection Advice
SI83414BAA-IFSame 4-channel low-side architecture but includes VDD2_WRN indicator pin; lacks OPEN_CH pinSuitable where switch supply undervoltage warning is prioritized over open-load detectionSelect SI83414BAA-IF if monitoring VDD2 brownout is more critical than detecting broken wiring
SI83414ABA-IFIncludes both VDD2_WRN and OPEN_CH indicators; supports Inrush Current Mode (8 A/20 ms)Required for lamp-driving applications needing inrush support and dual fault visibilityChoose SI83414ABA-IF when driving incandescent loads and full diagnostic coverage is mandatory

Compared with SI83414BCA-IF, SI83414BAA-IF trades open-circuit detection for supply warning capability, while SI83414ABA-IF adds both features plus inrush mode - making it functionally richer but less pin-compatible due to additional indicator pin usage.

Availability

SI83414BCA-IF is available at Aetrix Electronics and suitable for programmable logic controllers, industrial motion controllers, and smart solid-state relays requiring stable component supply, long-term lifecycle assurance, and certified isolation performance.

Supply support for SI83414BCA-IF includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

Skyworks Solutions is a global semiconductor company specializing in analog and mixed-signal connectivity solutions, with leadership in RF, timing, and isolation technologies.

The Si834x product line was engineered specifically for industrial automation I/O modules, delivering robust galvanic isolation, integrated diagnostics, and simplified migration from legacy optocoupler-based designs.

FAQ

What is the maximum continuous current per channel for SI83414BCA-IF?

The SI83414BCA-IF supports 700 mA continuous current per channel at 25°C ambient, with RON = 155 mΩ typical. Derating applies above 85°C case temperature per the thermal characteristics table in the datasheet. This rating assumes proper PCB copper area (≥200 mm² per GND2 pad) and airflow per Skyworks' recommended layout.

Does SI83414BCA-IF support SPI communication?

No, SI83414BCA-IF does not support SPI communication. It belongs to the "Parallel-only" interface family (denoted by 'C' in the ordering code suffix), relying solely on direct logic-level inputs (A1–A4) and asynchronous OE control. Diagnostics are reported exclusively through open-drain indicator pins (FLT, LED1–LED4, OPEN_CH).

What isolation certifications apply to SI83414BCA-IF?

SI83414BCA-IF carries pending UL 1577 recognition (1500 Vrms for 1 minute), CSA certification under 62368-1, and CQC approval to GB4943.1. Its 1.5 kVRMS isolation rating and >100 kV/µs CMTI meet IEC 61131-2 Type 3 requirements for industrial digital outputs.

How does the OPEN_CH pin function on SI83414BCA-IF?

The OPEN_CH pin on SI83414BCA-IF is an active-low open-drain output that asserts when any of the four channels detects an open-circuit condition - such as a broken wire, disconnected solenoid, or failed lamp filament. It remains asserted until the fault clears and the device confirms load continuity, enabling immediate field maintenance response.

Can SI83414BCA-IF drive inductive loads like relays without external protection?

Yes, SI83414BCA-IF can drive inductive loads without external flyback diodes or snubbers. Its integrated multi-voltage output clamp handles unlimited demagnetization energy (EAS) during turn-off, ensuring fast, controlled inductor discharge while protecting the internal MOSFET from voltage overshoot - validated across 24 V, 500 mH relay coils.

SI83414BCA-IF Specifications

Product attributes
Attribute value
Manufacturer:
Skyworks Solutions Inc.
Series:
Si834x
Package/Case:
32-VFDFN Exposed Pad
Packaging:
Tray
Product Status:
Active
Technology:
Capacitive Coupling
Type:
SPI
Isolated Power:
Yes
Number of Channels:
4
Inputs - Side 1/Side 2:
4/0
Channel Type:
Bidirectional, Unidirectional
Voltage - Isolation:
1500Vrms
Common Mode Transient Immunity (Min):
100kV/µs
Data Rate:
-
Propagation Delay tpLH / tpHL (Max):
3.7µs, 3.7µs
Pulse Width Distortion (Max):
-
Rise / Fall Time (Typ):
-, 3µs
Voltage - Supply:
2.25V ~ 5.5V, 9V ~ 32V
Grade:
-
Qualification:
-
Operating Temperature:
-40°C ~ 125°C
Mounting Type:
Surface Mount
Supplier Device Package:
32-DFN (9x9)

SI83414BCA-IF FAQ

1.How can I place an order for SI83414BCA-IF through Aetrix?

Please submit a Request for Quotation (RFQ) for SI83414BCA-IF on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for SI83414BCA-IF reliable?

The price and inventory of SI83414BCA-IF are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for SI83414BCA-IF is usually 5 days.

3.What payment methods are accepted for SI83414BCA-IF?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for SI83414BCA-IF transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for SI83414BCA-IF?

SI83414BCA-IF orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your SI83414BCA-IF order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for SI83414BCA-IF?

For technical support, including SI83414BCA-IF datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your SI83414BCA-IF requirements.

6.How does Aetrix verify that SI83414BCA-IF is sourced from the original manufacturer or authorized distributors?

All SI83414BCA-IF products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that SI83414BCA-IF meets industry standards.

7.What is the process for return or replacement of SI83414BCA-IF?

All SI83414BCA-IF units undergo pre-shipment inspection (PSI). If there is an issue with SI83414BCA-IF, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The SI83414BCA-IF part is unused and in its original packaging.

Return procedure for SI83414BCA-IF:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

SI83414BCA-IF Tags

  • SI83414BCA-IF
  • SI83414BCA-IF PDF
  • SI83414BCA-IF Datasheet
  • SI83414BCA-IF Specifications
  • SI83414BCA-IF Images
  • Skyworks Solutions Inc.
  • Skyworks Solutions Inc. SI83414BCA-IF
  • Buy SI83414BCA-IF
  • SI83414BCA-IF Price
  • SI83414BCA-IF Distributor
  • SI83414BCA-IF Supplier
  • SI83414BCA-IF Wholesale
Related Products
ISO1212DBQR
ISO1212DBQR

Texas Instruments

ISO6721BDR
ISO6721BDR

Texas Instruments

SI8710AC-B-ISR
SI8710AC-B-ISR

Skyworks Solutions Inc.

ISO7720FDR
ISO7720FDR

Texas Instruments

ISO7721DR
ISO7721DR

Texas Instruments

ISO7721FDR
ISO7721FDR

Texas Instruments

SI8710CC-B-ISR
SI8710CC-B-ISR

Skyworks Solutions Inc.

ISO6741FQDWRQ1
ISO6741FQDWRQ1

Texas Instruments

ISO7721DWVR
ISO7721DWVR

Texas Instruments

ISO7762FDBQR
ISO7762FDBQR

Texas Instruments

ISO7741DWR
ISO7741DWR

Texas Instruments

ISO7741FDWR
ISO7741FDWR

Texas Instruments

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER