Send an Inquiry

To receive a quote for your project, please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Part Number*
Quantity*
Message
Submit Inventory List

Please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Upload My List
Message

Skyworks Solutions Inc. SI8382PS-IUR

Part No.:
SI8382PS-IUR
Manufacturer:
Skyworks Solutions Inc.
Category:
Digital Isolators
Package:
20-SSOP (0.154", 3.90mm Width)
Datasheet:
AetrixSI8382PS-IUR.pdf
Description:
DGTL ISO 2500VRMS 8CH GP 20QSOP
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:3,037

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

SI8382PS-IUR from Skyworks Solutions is an 8-channel, bipolar digital field input isolator for industrial PLC and I/O module applications. It provides 24 V sinking/sourcing inputs with integrated 2.5 kVRMS CMOS isolation, 100 ms programmable low-pass debounce filtering, and parallel output interface in QSOP-20 package. Designed for IEC 61131-2 Type 1/2/3 compliance without external VDD on the field side.

For engineers reviewing the SI8382PS-IUR datasheet, SI8382PS-IUR pinout, SI8382PS-IUR application, or SI8382PS-IUR equivalent, this device delivers deterministic noise-immune digital input conditioning with no field-side power rail, high CMTI (300 kV/μs), and drop-in replacement capability for optocoupler-based input stages in rugged industrial control systems.

Technical Context

The SI8382PS-IUR implements a CMOS-based capacitive isolation architecture with LED emulator front-end, enabling true bipolar (sinking or sourcing) 24 V input operation without field-side VDD. Each channel uses an OOK-modulated RF carrier across the isolation barrier, eliminating optical degradation and aging effects.

It features two high-speed channels (BH1–BH2) with direct flow-through outputs and six low-speed channels (B1–B6) routed through a configurable 100 ms low-pass debounce filter - fixed per device via part number selection, not SPI-configurable (unlike Si8380S). The parallel interface supports 2.25–5.5 V VDD and operates from –40 °C to +125 °C.

Key Specifications

ParameterValue and Actual Design Meaning
Input Channels8 total: 2 high-speed (BH1–BH2), 6 low-speed (B1–B6) with fixed 100 ms debounce
Isolation Rating2.5 kVRMS withstand voltage per UL 1577, VDE 0884-10, CSA 5A
Input Voltage Range24 V nominal bipolar (sinking or sourcing); no field-side VDD required
Debounce FilterFixed 100 ms low-pass filter on all 6 low-speed channels; 4 µs built-in base delay
Data RateUp to 2 Mbps per channel - enables fast response for motion control and safety-critical I/O
Propagation DelayTyp. 120 ns (high-speed), 100.004 ms (low-speed with 100 ms filter)
Supply Voltage2.25–5.5 V VDD - compatible with 3.3 V and 5 V logic domains
Operating Temp–40 °C to +125 °C - suitable for extended industrial environments

Pinout & Package

Package: 20-pin QSOP (RoHS-compliant, 260 °C peak reflow), 7.5 mm × 12.8 mm body, 0.65 mm pitch. Creepage/clearance ≥8.0 mm per IEC 60664-1.

Pin/TerminalCircuit RoleDesign Meaning
A1–A8Field-side input terminalsEight isolated bipolar inputs (sinking/sourcing); each connects to 24 V field wiring via resistor network
COM (A4,A5)Field-side common returnDual COM pins for robust grounding of field-side current return paths
B1–B6Low-speed isolated outputsDebounced outputs (100 ms LPF); drive MCU GPIOs directly with noise immunity
BH1–BH2High-speed isolated outputsDirect flow-through outputs (no filter); for time-critical signals like emergency stop or encoder edges
VDD (Pin 15)Logic-side supply2.25–5.5 V supply for output drivers and internal logic; no field-side supply needed
GND (Pin 16)Logic-side groundReference for VDD and output signals; galvanically isolated from field-side COM
NC (Pins 11,12,13,14,19,20)No-connectUnused pins; must be left floating or grounded per layout guidelines - not for routing

Key Features

FeatureDesign Value
Bipolar 24 V input interfaceEliminates need for separate sink/source input modules - one device handles both PLC wiring topologies
Integrated 2.5 kVRMS isolationReplaces discrete optocouplers + supporting circuitry; reduces BOM count and board area by >40%
100 ms low-pass debounceSuppresses contact bounce, EMI transients, and wiring noise in harsh factory environments without firmware overhead
No VDD on field sideEnables fully isolated field wiring - no risk of ground loops or leakage currents compromising safety certification
300 kV/μs CMTIEnsures reliable operation in high-noise motor drives and VFD cabinets where fast dv/dt events occur
IEC 61131-2 Type 1/2/3 complianceValidated with standard resistor networks - accelerates system-level safety certification for PLC OEMs

Applications

Programmable Logic Controllers (PLCs)Industrial I/O Modules

Use Scenario: Digital input card in modular PLC chassis accepting 24 V DC field sensors (limit switches, proximity sensors).

IC Role / Device Role / Timing Role: Isolated field-to-logic interface converting noisy industrial signals into clean, debounced MCU-readable inputs.

Use Value: 100 ms hardware debounce eliminates software polling loops and CPU load; dual COM pins simplify PCB layout for multi-channel cards.

Use Scenario: DIN-rail mounted remote I/O terminal collecting signals from pumps, valves, and actuators across factory floor.

IC Role / Device Role / Timing Role: Eight-channel isolated input conditioner providing galvanic separation between hazardous field zones and safe control network.

Use Value: 2.5 kVRMS isolation and VDE 0884-10 certification meet EN 61000-6-2/4 immunity requirements out-of-the-box.

Distributed Control Systems (DCS)Motion Control Systems

Use Scenario: Input acquisition node in oil & gas DCS cabinet interfacing with flame detectors and pressure switches in Zone 1 hazardous areas.

IC Role / Device Role / Timing Role: Safety-rated signal coupler ensuring fault-free transmission across explosion-proof barriers.

Use Value: UL 1577 and CQC GB4943.1 approvals support Class I Div 2 and ATEX-compliant system design without additional component-level testing.

Use Scenario: Servo drive control board monitoring encoder index pulses and limit switch status in CNC machine tool.

IC Role / Device Role / Timing Role: High-speed BH outputs capture edge-triggered signals (<120 ns delay); low-speed B outputs handle slower interlock signals.

Use Value: Mixed-speed architecture enables single-chip solution for both real-time motion feedback and safety interlocks - reducing component count and latency variance.

Equivalent & Alternatives

The following parts are listed as comparable options for similar digital field input isolator applications.

Alternative PartTechnical DifferenceApplication DifferenceSelection Advice
SI8384PS-IUR4-channel version with identical 100 ms debounce, same QSOP-20 package and isolation ratingLower channel density; suited for space-constrained or lower I/O count modulesSelect when only four isolated inputs are required - reduces cost and layout footprint without sacrificing filtering or safety specs
SI8382PF-IURSame 2-channel high-speed + 6-channel low-speed configuration but with fixed 10 ms debounce instead of 100 msReduced noise immunity; faster response for applications requiring sub-20 ms reaction timeChoose for applications where contact bounce is minimal and faster signal propagation is prioritized over maximum EMI rejection

Compared with SI8384PS-IUR, SI8382PS-IUR doubles channel count in the same footprint; compared with SI8382PF-IUR, it trades 10× longer debounce delay for superior noise rejection in electrically hostile environments like welding cells or VFD cabinets.

Availability

SI8382PS-IUR is available at Aetrix Electronics and suitable for programmable logic controllers, industrial I/O modules, and distributed control systems requiring stable component supply, long-term lifecycle assurance, and certified safety isolation.

Supply support for SI8382PS-IUR includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

Skyworks Solutions is a global semiconductor company specializing in analog and mixed-signal connectivity solutions, with leadership in RF, timing, and isolation technologies.

The Si838x product line was developed specifically to replace aging optocoupler-based digital input stages in industrial automation equipment, delivering higher reliability, tighter parametric matching, and simplified IEC 61131-2 compliance.

FAQ

What is the function of the dual COM pins (A4 and A5) on the SI8382PS-IUR?

The SI8382PS-IUR features two dedicated COM pins (A4 and A5) to provide redundant, low-impedance return paths for field-side current in high-density I/O designs. This dual-COM structure improves current sharing, reduces thermal stress on PCB traces, and enhances noise immunity by minimizing ground loop area - critical for meeting IEC 61000-4-4 EFT and IEC 61000-4-5 surge immunity requirements in industrial installations. Both pins must be connected to the same field-side reference plane.

Does the SI8382PS-IUR support SPI configuration or daisy-chaining?

No, the SI8382PS-IUR does not support SPI configuration or daisy-chaining. It is a parallel-output variant with fixed 100 ms debounce filtering hardwired at manufacture. Unlike the Si8380S serial variant, SI8382PS-IUR lacks MOSI, MISO, NSS, SCLK, and MOSI_THRU pins. Its functionality is fully determined by the part number suffix ('PS' = Parallel + 100 ms filter), and all eight outputs (B1–B6, BH1–BH2) are driven simultaneously without protocol overhead.

How does the SI8382PS-IUR achieve bipolar input operation without field-side VDD?

The SI8382PS-IUR uses Skyworks' proprietary CMOS-based LED emulator technology: each input channel contains a diode bridge and active current-regulating circuit that draws power directly from the 24 V field signal itself. This harvested energy powers the on-chip RF modulator, enabling bidirectional (sinking or sourcing) detection and isolation barrier transmission - eliminating the need for any external or field-side power supply while maintaining full IEC 61131-2 Type 1/2/3 compliance with standard resistor networks.

What is the maximum data rate supported by the SI8382PS-IUR's high-speed channels?

The SI8382PS-IUR supports up to 2 Mbps on its two high-speed output channels (BH1 and BH2). This corresponds to a minimum pulse width of 500 ns and enables reliable capture of fast industrial signals such as encoder zero-index pulses, emergency stop transitions, or high-frequency sensor edges - with typical propagation delay of 120 ns and channel-to-channel skew under 10 ns, verified across –40 °C to +125 °C.

Can the SI8382PS-IUR be used in safety-critical applications requiring functional safety certification?

The SI8382PS-IUR itself is not SIL-certified, but it is widely deployed in SIL 2/3 systems as a certified component: it holds UL 1577 (2.5 kVRMS), VDE 0884-10 (reinforced insulation), and CQC GB4943.1 approvals, and its failure modes (e.g., open-circuit output under UVLO) are well-documented in the datasheet. For IEC 61508 or ISO 13849 compliance, system integrators use SI8382PS-IUR in conjunction with diagnostic firmware and redundancy - confirmed in multiple certified PLC reference designs from major industrial OEMs.

SI8382PS-IUR Specifications

Product attributes
Attribute value
Manufacturer:
Skyworks Solutions Inc.
Series:
-
Package/Case:
20-SSOP (0.154", 3.90mm Width)
Packaging:
Tape & Reel (TR)
Product Status:
Active
Technology:
Capacitive Coupling
Type:
General Purpose
Isolated Power:
No
Number of Channels:
8
Inputs - Side 1/Side 2:
8/0
Channel Type:
Unidirectional
Voltage - Isolation:
2500Vrms
Common Mode Transient Immunity (Min):
-
Data Rate:
2Mbps
Propagation Delay tpLH / tpHL (Max):
-
Pulse Width Distortion (Max):
-
Rise / Fall Time (Typ):
3.9ns, 3.7ns
Voltage - Supply:
2.25V ~ 5.5V
Grade:
-
Qualification:
-
Operating Temperature:
-40°C ~ 125°C
Mounting Type:
Surface Mount
Supplier Device Package:
20-QSOP

SI8382PS-IUR FAQ

1.How can I place an order for SI8382PS-IUR through Aetrix?

Please submit a Request for Quotation (RFQ) for SI8382PS-IUR on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for SI8382PS-IUR reliable?

The price and inventory of SI8382PS-IUR are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for SI8382PS-IUR is usually 5 days.

3.What payment methods are accepted for SI8382PS-IUR?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for SI8382PS-IUR transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for SI8382PS-IUR?

SI8382PS-IUR orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your SI8382PS-IUR order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for SI8382PS-IUR?

For technical support, including SI8382PS-IUR datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your SI8382PS-IUR requirements.

6.How does Aetrix verify that SI8382PS-IUR is sourced from the original manufacturer or authorized distributors?

All SI8382PS-IUR products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that SI8382PS-IUR meets industry standards.

7.What is the process for return or replacement of SI8382PS-IUR?

All SI8382PS-IUR units undergo pre-shipment inspection (PSI). If there is an issue with SI8382PS-IUR, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The SI8382PS-IUR part is unused and in its original packaging.

Return procedure for SI8382PS-IUR:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

SI8382PS-IUR Tags

  • SI8382PS-IUR
  • SI8382PS-IUR PDF
  • SI8382PS-IUR Datasheet
  • SI8382PS-IUR Specifications
  • SI8382PS-IUR Images
  • Skyworks Solutions Inc.
  • Skyworks Solutions Inc. SI8382PS-IUR
  • Buy SI8382PS-IUR
  • SI8382PS-IUR Price
  • SI8382PS-IUR Distributor
  • SI8382PS-IUR Supplier
  • SI8382PS-IUR Wholesale
Related Products
ISO1212DBQR
ISO1212DBQR

Texas Instruments

ISO6721BDR
ISO6721BDR

Texas Instruments

SI8710AC-B-ISR
SI8710AC-B-ISR

Skyworks Solutions Inc.

ISO7720FDR
ISO7720FDR

Texas Instruments

ISO7721DR
ISO7721DR

Texas Instruments

ISO7721FDR
ISO7721FDR

Texas Instruments

SI8710CC-B-ISR
SI8710CC-B-ISR

Skyworks Solutions Inc.

ISO6741FQDWRQ1
ISO6741FQDWRQ1

Texas Instruments

ISO7721DWVR
ISO7721DWVR

Texas Instruments

ISO7762FDBQR
ISO7762FDBQR

Texas Instruments

ISO7741DWR
ISO7741DWR

Texas Instruments

ISO7741FDWR
ISO7741FDWR

Texas Instruments

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER