Skyworks Solutions Inc. SKY87604-13

Part No.:
SKY87604-13
Manufacturer:
Skyworks Solutions Inc.
Category:
Electrical, Specialty Fuses
Package:
Module
Datasheet:
AetrixSKY87604-13.pdf
Description:
OVERMOLDED 375MA FUSE FOR GAS ME
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:295

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

SKY87604-13 from Skyworks Solutions is a fast-acting, over-molded fuse rated at 375 mA, operating from –40 °C to +125 °C, housed in a 3.0 mm × 3.0 mm, 4-lead MCM package, and certified to UL 60079-11 for intrinsic safety in hazardous environments-used in gas meter modules to protect against overcurrent during surge events.

For engineers reviewing the SKY87604-13 datasheet, SKY87604-13 pinout, SKY87604-13 application, or SKY87604-13 equivalent, key selection criteria include I²t rating for inrush tolerance, UL 60079-11 compliance for explosion-proof designs, lead-free reflow compatibility, and 0.5 mm minimum non-metallic encapsulation thickness around the fuse element.

Technical Context

The SKY87604-13 implements a fast-acting fuse structure with high I²t capability to withstand transient inrush currents without nuisance tripping, while maintaining precise 375 mA nominal hold current. Its over-molded construction ensures ≥0.5 mm non-metallic clearance per UL 60079-11, isolating metallic terminals from external conductive surfaces.

This device functions as a single-pole, dual-terminal (pins 1 & 4 = terminal 1; pins 2 & 3 = terminal 2) passive overcurrent protection element. It requires pairing with a UL-recognized component fuse per design guidance and supports both leaded and lead-free soldering processes.

Key Specifications

ParameterValue and Actual Design Meaning
Nominal Current375 mA - exact hold current before thermal trip under steady-state DC conditions
Operating Temp–40 °C to +125 °C - validated performance across industrial and metering ambient extremes
Package Size3.0 mm × 3.0 mm - ultra-compact footprint enabling high-density PCB layout in space-constrained gas meters
UL CertificationUL 60079-11 - certifies fuse element is fully surrounded by ≥0.5 mm non-metallic material for intrinsic safety
Lead Finish100% lead-free, RoHS & halogen-free - compliant with IPC/JEDEC J-STD-020C MSL3 reflow profile (260 °C)
Terminal ConfigurationDual-terminal, 4-lead MCM - pins 1 & 4 electrically common (T1), pins 2 & 3 electrically common (T2)

Pinout & Package

SKY87604-13 uses a 4-lead, 3.0 mm × 3.0 mm molded chip module (MCM) package with moisture sensitivity level 3 (MSL3) and Pb-free terminations.

Pin/TerminalCircuit RoleDesign Meaning
Pin 1Terminal 1 (T1)Input/output connection point for one side of fuse element; electrically identical to Pin 4
Pin 2Terminal 2 (T2)Input/output connection point for opposite side of fuse element; electrically identical to Pin 3
Pin 3Terminal 2 (T2)Redundant T2 connection for enhanced current handling and solder joint reliability
Pin 4Terminal 1 (T1)Redundant T1 connection supporting low-inductance, high-current PCB routing

Key Features

FeatureDesign Value
Fast-acting responseEnables rapid interruption of fault currents before downstream circuit damage occurs in gas meter power rails
High I²t ratingSupports repeated inrush surges (e.g., solenoid actuation, cold-start capacitors) without degradation or false trip
Over-molded insulationGuarantees ≥0.5 mm non-metallic barrier around fuse element to meet UL 60079-11 intrinsic safety requirements
Halogen-free & RoHSMeets global environmental compliance mandates including Skyworks Green™ SQ04–0074 specification

Applications

Gas Meter Power ProtectionIndustrial Flow Sensor Modules

Use Scenario: Protects battery-backed or mains-powered gas meter mainboard from short-circuit faults during valve actuation or sensor excitation.

IC Role / Device Role / Timing Role: Passive overcurrent protection device placed in series with primary power input rail.

Use Value: Prevents fire hazard and system failure by interrupting >375 mA faults within milliseconds while surviving repetitive 500 mA inrush peaks.

Use Scenario: Safeguards ultrasonic or turbine flow sensors in hazardous-area installations where electrical isolation is mandated.

IC Role / Device Role / Timing Role: Intrinsic safety barrier component ensuring energy limitation per UL 60079-11 in Class I Div 1/Zone 0 environments.

Use Value: Enables certification compliance without external potting or spacing hardware due to built-in 0.5 mm non-metallic encapsulation.

Smart Utility Meter SubsystemsExplosion-Proof Communication Interfaces

Use Scenario: Secures RF transceiver or PLC modem power supply in AMI (Advanced Metering Infrastructure) endpoints.

IC Role / Device Role / Timing Role: Primary overcurrent limiter on isolated DC-DC converter output feeding communication ICs.

Use Value: Maintains uninterrupted data transmission during load transients while blocking sustained overloads that could corrupt firmware or memory.

Use Scenario: Integrates into RS-485 or CAN bus interface circuits deployed in petrochemical plant control cabinets.

IC Role / Device Role / Timing Role: Energy-limiting fuse in intrinsically safe barrier design upstream of physical layer transceivers.

Use Value: Eliminates need for discrete creepage/clearance spacers by embedding required insulation directly into package geometry.

Equivalent & Alternatives

The following parts are listed as comparable options for similar fast-acting fuse applications.

Alternative PartTechnical DifferenceApplication DifferenceSelection Advice
Littelfuse 0ZCM375-2ASame 375 mA rating, but 6.1 mm × 2.7 mm SMD package; lower I²t; UL 248-14 certified (not UL 60079-11)Approved for general industrial overcurrent protection, not certified for intrinsic safety in explosive atmospheresSelect only if UL 60079-11 compliance is not required and board space allows larger footprint
Bourns MF-MSMF375375 mA PPTC resettable fuse; higher trip resistance; no UL 60079-11 listing; self-resetting behaviorSuitable for non-safety-critical, maintenance-accessible systems where automatic recovery is preferred over replacementChoose when fault recovery without manual intervention is prioritized over single-event reliability and intrinsic safety certification

Compared with Littelfuse 0ZCM375-2A and Bourns MF-MSMF375, the SKY87604-13 uniquely delivers UL 60079-11 compliance in a 3.0 mm × 3.0 mm footprint with verified high I²t tolerance-making it the only option qualified for gas meter intrinsic safety barriers without external insulation augmentation.

Availability

SKY87604-13 is available at Aetrix Electronics and suitable for gas meter modules, industrial flow sensor subsystems, and smart utility meter power rails requiring stable component supply, intrinsic safety certification, and high-reliability overcurrent protection.

Supply support for SKY87604-13 includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

Skyworks Solutions is a global semiconductor company specializing in analog and mixed-signal connectivity solutions for wireless, automotive, and industrial markets.

The SKY87604-13 belongs to Skyworks' protected circuit portfolio, engineered specifically for intrinsic safety–critical applications such as gas, water, and utility metering in hazardous locations.

FAQ

What is the rated hold current and trip behavior of the SKY87604-13?

The SKY87604-13 is rated for a nominal hold current of 375 mA under steady-state DC conditions. It exhibits fast-acting thermal trip behavior, interrupting currents significantly above its rating within milliseconds. Its high I²t value allows survival of brief inrush surges-such as those from solenoid valves-without nuisance tripping, while reliably opening during sustained overloads. This behavior is validated per UL 60079-11 test protocols.

Does the SKY87604-13 meet UL 60079-11 for intrinsic safety applications?

Yes, the SKY87604-13 is designed and certified to satisfy UL 60079-11, which mandates that the fuse element be fully surrounded by at least 0.5 mm of non-metallic material. Its over-molded construction achieves this requirement inherently, eliminating the need for additional potting or spacing hardware in gas meter and hazardous-area designs. The SKY87604-13 documentation explicitly references UL 60079-11 compliance.

What is the package type and soldering compatibility of the SKY87604-13?

The SKY87604-13 uses a 4-lead, 3.0 mm × 3.0 mm molded chip module (MCM) package rated MSL3 per IPC/JEDEC J-STD-020C, with peak reflow temperature support up to 260 °C. It is 100% lead-free, RoHS-compliant, and halogen-free, and is compatible with both leaded and lead-free wave and reflow soldering processes-ensuring robust manufacturability in high-volume meter production lines.

How are the four pins configured electrically on the SKY87604-13?

The SKY87604-13 has a dual-terminal configuration: Pins 1 and 4 are electrically common as Terminal 1 (T1), and Pins 2 and 3 are electrically common as Terminal 2 (T2). This arrangement provides redundant connections per terminal to reduce contact resistance, improve current sharing, and enhance mechanical reliability during thermal cycling-critical for long-life deployments in utility metering applications.

Is the SKY87604-13 suitable for use in explosion-proof enclosures or hazardous locations?

Yes-the SKY87604-13 is explicitly intended for intrinsic safety–critical applications in hazardous locations, including Class I Division 1 and Zone 0 environments. Its UL 60079-11 certification confirms compliance with energy-limiting requirements for explosion-proof barrier designs. When used per Skyworks' application guidance and paired with a UL-recognized component fuse, the SKY87604-13 enables full system-level intrinsic safety certification in gas meter modules.

SKY87604-13 Specifications

Product attributes
Attribute value
Manufacturer:
Skyworks Solutions Inc.
Series:
-
Package / Case:
Module
Packaging:
Tape & Reel (TR)
Product Status:
Active
Mounting Type:
Surface Mount
Fuse Type:
-
Current Rating (Amps):
375mA
Voltage Rating - AC:
32 VAC
Voltage Rating - DC:
63 VDC
Response Time:
Fast Blow
Applications:
Gas Meter Modules
Features:
-
Class:
-
Approval Agency:
UL
Operating Temperature:
-40°C ~ 125°C
Breaking Capacity @ Rated Voltage:
-
Size / Dimension:
0.118" L x 0.118" W x 0.073" H (3.00mm x 3.00mm x 1.85mm)
Grade:
-
Qualification:
-

SKY87604-13 FAQ

1.How can I place an order for SKY87604-13 through Aetrix?

Please submit a Request for Quotation (RFQ) for SKY87604-13 on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for SKY87604-13 reliable?

The price and inventory of SKY87604-13 are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for SKY87604-13 is usually 5 days.

3.What payment methods are accepted for SKY87604-13?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for SKY87604-13 transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for SKY87604-13?

SKY87604-13 orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your SKY87604-13 order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for SKY87604-13?

For technical support, including SKY87604-13 datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your SKY87604-13 requirements.

6.How does Aetrix verify that SKY87604-13 is sourced from the original manufacturer or authorized distributors?

All SKY87604-13 products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that SKY87604-13 meets industry standards.

7.What is the process for return or replacement of SKY87604-13?

All SKY87604-13 units undergo pre-shipment inspection (PSI). If there is an issue with SKY87604-13, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The SKY87604-13 part is unused and in its original packaging.

Return procedure for SKY87604-13:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

SKY87604-13 Tags

  • SKY87604-13
  • SKY87604-13 PDF
  • SKY87604-13 Datasheet
  • SKY87604-13 Specifications
  • SKY87604-13 Images
  • Skyworks Solutions Inc.
  • Skyworks Solutions Inc. SKY87604-13
  • Buy SKY87604-13
  • SKY87604-13 Price
  • SKY87604-13 Distributor
  • SKY87604-13 Supplier
  • SKY87604-13 Wholesale
Related Products
04611.25ER
04611.25ER

Littelfuse Inc.

0461.500ER
0461.500ER

Littelfuse Inc.

0461002.ER
0461002.ER

Littelfuse Inc.

0308.750UR
0308.750UR

Littelfuse Inc.

0159002.MR
0159002.MR

Littelfuse Inc.

ITV4030L0812NR
ITV4030L0812NR

Littelfuse Inc.

BK/GMT-7-1/2A
BK/GMT-7-1/2A

Eaton - Bussmann Electrical Division

0242.100UAT1
0242.100UAT1

Littelfuse Inc.

BK/GMT-15A
BK/GMT-15A

Eaton - Bussmann Electrical Division

0242.050UAT1
0242.050UAT1

Littelfuse Inc.

0242.200UAT1
0242.200UAT1

Littelfuse Inc.

0242.100UR
0242.100UR

Littelfuse Inc.

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER