Skyworks Solutions Inc. SKY87604-13
- Part No.:
- SKY87604-13
- Manufacturer:
- Skyworks Solutions Inc.
- Category:
- Electrical, Specialty Fuses
- Package:
- Module
- Datasheet:
-
SKY87604-13.pdf
- Description:
- OVERMOLDED 375MA FUSE FOR GAS ME
- Quantity:
- Payment:

- Shipping:

Inventory:295
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
SKY87604-13 from Skyworks Solutions is a fast-acting, over-molded fuse rated at 375 mA, operating from –40 °C to +125 °C, housed in a 3.0 mm × 3.0 mm, 4-lead MCM package, and certified to UL 60079-11 for intrinsic safety in hazardous environments-used in gas meter modules to protect against overcurrent during surge events.
For engineers reviewing the SKY87604-13 datasheet, SKY87604-13 pinout, SKY87604-13 application, or SKY87604-13 equivalent, key selection criteria include I²t rating for inrush tolerance, UL 60079-11 compliance for explosion-proof designs, lead-free reflow compatibility, and 0.5 mm minimum non-metallic encapsulation thickness around the fuse element.
Technical Context
The SKY87604-13 implements a fast-acting fuse structure with high I²t capability to withstand transient inrush currents without nuisance tripping, while maintaining precise 375 mA nominal hold current. Its over-molded construction ensures ≥0.5 mm non-metallic clearance per UL 60079-11, isolating metallic terminals from external conductive surfaces.
This device functions as a single-pole, dual-terminal (pins 1 & 4 = terminal 1; pins 2 & 3 = terminal 2) passive overcurrent protection element. It requires pairing with a UL-recognized component fuse per design guidance and supports both leaded and lead-free soldering processes.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Nominal Current | 375 mA - exact hold current before thermal trip under steady-state DC conditions |
| Operating Temp | –40 °C to +125 °C - validated performance across industrial and metering ambient extremes |
| Package Size | 3.0 mm × 3.0 mm - ultra-compact footprint enabling high-density PCB layout in space-constrained gas meters |
| UL Certification | UL 60079-11 - certifies fuse element is fully surrounded by ≥0.5 mm non-metallic material for intrinsic safety |
| Lead Finish | 100% lead-free, RoHS & halogen-free - compliant with IPC/JEDEC J-STD-020C MSL3 reflow profile (260 °C) |
| Terminal Configuration | Dual-terminal, 4-lead MCM - pins 1 & 4 electrically common (T1), pins 2 & 3 electrically common (T2) |
Pinout & Package
SKY87604-13 uses a 4-lead, 3.0 mm × 3.0 mm molded chip module (MCM) package with moisture sensitivity level 3 (MSL3) and Pb-free terminations.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| Pin 1 | Terminal 1 (T1) | Input/output connection point for one side of fuse element; electrically identical to Pin 4 |
| Pin 2 | Terminal 2 (T2) | Input/output connection point for opposite side of fuse element; electrically identical to Pin 3 |
| Pin 3 | Terminal 2 (T2) | Redundant T2 connection for enhanced current handling and solder joint reliability |
| Pin 4 | Terminal 1 (T1) | Redundant T1 connection supporting low-inductance, high-current PCB routing |
Key Features
| Feature | Design Value |
|---|---|
| Fast-acting response | Enables rapid interruption of fault currents before downstream circuit damage occurs in gas meter power rails |
| High I²t rating | Supports repeated inrush surges (e.g., solenoid actuation, cold-start capacitors) without degradation or false trip |
| Over-molded insulation | Guarantees ≥0.5 mm non-metallic barrier around fuse element to meet UL 60079-11 intrinsic safety requirements |
| Halogen-free & RoHS | Meets global environmental compliance mandates including Skyworks Green™ SQ04–0074 specification |
Applications
| Gas Meter Power Protection | Industrial Flow Sensor Modules |
|---|---|
Use Scenario: Protects battery-backed or mains-powered gas meter mainboard from short-circuit faults during valve actuation or sensor excitation. IC Role / Device Role / Timing Role: Passive overcurrent protection device placed in series with primary power input rail. Use Value: Prevents fire hazard and system failure by interrupting >375 mA faults within milliseconds while surviving repetitive 500 mA inrush peaks. | Use Scenario: Safeguards ultrasonic or turbine flow sensors in hazardous-area installations where electrical isolation is mandated. IC Role / Device Role / Timing Role: Intrinsic safety barrier component ensuring energy limitation per UL 60079-11 in Class I Div 1/Zone 0 environments. Use Value: Enables certification compliance without external potting or spacing hardware due to built-in 0.5 mm non-metallic encapsulation. |
| Smart Utility Meter Subsystems | Explosion-Proof Communication Interfaces |
Use Scenario: Secures RF transceiver or PLC modem power supply in AMI (Advanced Metering Infrastructure) endpoints. IC Role / Device Role / Timing Role: Primary overcurrent limiter on isolated DC-DC converter output feeding communication ICs. Use Value: Maintains uninterrupted data transmission during load transients while blocking sustained overloads that could corrupt firmware or memory. | Use Scenario: Integrates into RS-485 or CAN bus interface circuits deployed in petrochemical plant control cabinets. IC Role / Device Role / Timing Role: Energy-limiting fuse in intrinsically safe barrier design upstream of physical layer transceivers. Use Value: Eliminates need for discrete creepage/clearance spacers by embedding required insulation directly into package geometry. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar fast-acting fuse applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| Littelfuse 0ZCM375-2A | Same 375 mA rating, but 6.1 mm × 2.7 mm SMD package; lower I²t; UL 248-14 certified (not UL 60079-11) | Approved for general industrial overcurrent protection, not certified for intrinsic safety in explosive atmospheres | Select only if UL 60079-11 compliance is not required and board space allows larger footprint |
| Bourns MF-MSMF375 | 375 mA PPTC resettable fuse; higher trip resistance; no UL 60079-11 listing; self-resetting behavior | Suitable for non-safety-critical, maintenance-accessible systems where automatic recovery is preferred over replacement | Choose when fault recovery without manual intervention is prioritized over single-event reliability and intrinsic safety certification |
Compared with Littelfuse 0ZCM375-2A and Bourns MF-MSMF375, the SKY87604-13 uniquely delivers UL 60079-11 compliance in a 3.0 mm × 3.0 mm footprint with verified high I²t tolerance-making it the only option qualified for gas meter intrinsic safety barriers without external insulation augmentation.
Availability
SKY87604-13 is available at Aetrix Electronics and suitable for gas meter modules, industrial flow sensor subsystems, and smart utility meter power rails requiring stable component supply, intrinsic safety certification, and high-reliability overcurrent protection.
Supply support for SKY87604-13 includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Skyworks Solutions is a global semiconductor company specializing in analog and mixed-signal connectivity solutions for wireless, automotive, and industrial markets.
The SKY87604-13 belongs to Skyworks' protected circuit portfolio, engineered specifically for intrinsic safety–critical applications such as gas, water, and utility metering in hazardous locations.
FAQ
What is the rated hold current and trip behavior of the SKY87604-13?
The SKY87604-13 is rated for a nominal hold current of 375 mA under steady-state DC conditions. It exhibits fast-acting thermal trip behavior, interrupting currents significantly above its rating within milliseconds. Its high I²t value allows survival of brief inrush surges-such as those from solenoid valves-without nuisance tripping, while reliably opening during sustained overloads. This behavior is validated per UL 60079-11 test protocols.
Does the SKY87604-13 meet UL 60079-11 for intrinsic safety applications?
Yes, the SKY87604-13 is designed and certified to satisfy UL 60079-11, which mandates that the fuse element be fully surrounded by at least 0.5 mm of non-metallic material. Its over-molded construction achieves this requirement inherently, eliminating the need for additional potting or spacing hardware in gas meter and hazardous-area designs. The SKY87604-13 documentation explicitly references UL 60079-11 compliance.
What is the package type and soldering compatibility of the SKY87604-13?
The SKY87604-13 uses a 4-lead, 3.0 mm × 3.0 mm molded chip module (MCM) package rated MSL3 per IPC/JEDEC J-STD-020C, with peak reflow temperature support up to 260 °C. It is 100% lead-free, RoHS-compliant, and halogen-free, and is compatible with both leaded and lead-free wave and reflow soldering processes-ensuring robust manufacturability in high-volume meter production lines.
How are the four pins configured electrically on the SKY87604-13?
The SKY87604-13 has a dual-terminal configuration: Pins 1 and 4 are electrically common as Terminal 1 (T1), and Pins 2 and 3 are electrically common as Terminal 2 (T2). This arrangement provides redundant connections per terminal to reduce contact resistance, improve current sharing, and enhance mechanical reliability during thermal cycling-critical for long-life deployments in utility metering applications.
Is the SKY87604-13 suitable for use in explosion-proof enclosures or hazardous locations?
Yes-the SKY87604-13 is explicitly intended for intrinsic safety–critical applications in hazardous locations, including Class I Division 1 and Zone 0 environments. Its UL 60079-11 certification confirms compliance with energy-limiting requirements for explosion-proof barrier designs. When used per Skyworks' application guidance and paired with a UL-recognized component fuse, the SKY87604-13 enables full system-level intrinsic safety certification in gas meter modules.
SKY87604-13 Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Skyworks Solutions Inc.
- Series:
- -
- Package / Case:
- Module
- Packaging:
- Tape & Reel (TR)
- Product Status:
- Active
- Mounting Type:
- Surface Mount
- Fuse Type:
- -
- Current Rating (Amps):
- 375mA
- Voltage Rating - AC:
- 32 VAC
- Voltage Rating - DC:
- 63 VDC
- Response Time:
- Fast Blow
- Applications:
- Gas Meter Modules
- Features:
- -
- Class:
- -
- Approval Agency:
- UL
- Operating Temperature:
- -40°C ~ 125°C
- Breaking Capacity @ Rated Voltage:
- -
- Size / Dimension:
- 0.118" L x 0.118" W x 0.073" H (3.00mm x 3.00mm x 1.85mm)
- Grade:
- -
- Qualification:
- -
SKY87604-13 FAQ
1.How can I place an order for SKY87604-13 through Aetrix?
Please submit a Request for Quotation (RFQ) for SKY87604-13 on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for SKY87604-13 reliable?
The price and inventory of SKY87604-13 are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for SKY87604-13 is usually 5 days.
3.What payment methods are accepted for SKY87604-13?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for SKY87604-13 transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for SKY87604-13?
SKY87604-13 orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your SKY87604-13 order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for SKY87604-13?
For technical support, including SKY87604-13 datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your SKY87604-13 requirements.
6.How does Aetrix verify that SKY87604-13 is sourced from the original manufacturer or authorized distributors?
All SKY87604-13 products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that SKY87604-13 meets industry standards.
7.What is the process for return or replacement of SKY87604-13?
All SKY87604-13 units undergo pre-shipment inspection (PSI). If there is an issue with SKY87604-13, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The SKY87604-13 part is unused and in its original packaging.
Return procedure for SKY87604-13:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
SKY87604-13 Tags

-
04611.25ER
Littelfuse Inc.

-
0461.500ER
Littelfuse Inc.

-
0461002.ER
Littelfuse Inc.

-
0308.750UR
Littelfuse Inc.
-
0159002.MR
Littelfuse Inc.

-
ITV4030L0812NR
Littelfuse Inc.

-
BK/GMT-7-1/2A
Eaton - Bussmann Electrical Division

-
0242.100UAT1
Littelfuse Inc.

-
BK/GMT-15A
Eaton - Bussmann Electrical Division

-
0242.050UAT1
Littelfuse Inc.

-
0242.200UAT1
Littelfuse Inc.
-
0242.100UR
Littelfuse Inc.
Tech Hub
Counterfeit components can hide behind convincing markings and passing basic function tests. This engineering reference covers source traceability, external inspection, X-ray, XRF, electrical testing, …
A practical engineering and sourcing framework covering lifecycle verification, lifetime-buy calculations, replacement qualification, supplier checks and counterfeit-risk controls.
TTL and CMOS logic families differ in thresholds, loading, output drive, power and timing. This engineering guide compares 74HC and 74HCT, calculates noise margins and checks 3.3 V/5 V compatibility.
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…