Send an Inquiry

To receive a quote for your project, please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Part Number*
Quantity*
Message
Submit Inventory List

Please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Upload My List
Message

Texas Instruments TMP117MAIDRVT

Part No.:
TMP117MAIDRVT
Manufacturer:
Texas Instruments
Category:
Analog and Digital Output
Package:
6-WDFN Exposed Pad
Datasheet:
AetrixTMP117MAIDRVT.pdf
Description:
SENSOR TEMP
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:864

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

TMP117MAIDRVT from Texas Instruments is a high-accuracy, low-power digital temperature sensor with SMBus™- and I²C-compatible interface, ±0.1 °C accuracy from –20 °C to 50 °C, 16-bit resolution (0.0078 °C/LSB), and operation over –55 °C to 150 °C - deployed in electronic thermometers, cold-chain asset tracking, and wearable fitness monitors.

For engineers reviewing the TMP117MAIDRVT datasheet, TMP117MAIDRVT pinout, TMP117MAIDRVT application, or TMP117MAIDRVT equivalent, key selection criteria include medical-grade ASTM E1112/ISO 80601-2-56 compliance, NIST-traceable calibration, programmable alert thresholds, 48-bit general-purpose EEPROM, and RTD-replacement capability for PT100/PT1000 systems.

Technical Context

The TMP117MAIDRVT integrates a precision bandgap-based thermal sensing element with a 16-bit sigma-delta ADC and on-chip oscillator, delivering factory-calibrated temperature data without external compensation. Its digital architecture supports configurable averaging (1–8 conversions), programmable conversion cycle timing, and dual-mode alert functionality (over-temperature or data-ready).

It implements a two-wire interface compliant with both standard-mode (100 kHz) and fast-mode (400 kHz) I²C and SMBus protocols, including timeout detection and open-drain SDA/ALERT with internal pull-up support. The device uses EEPROM-stored configuration and offset correction values, enabling system-level calibration and persistent settings across power cycles.

Key Specifications

ParameterValue and Actual Design Meaning
Accuracy±0.1 °C max from –20 °C to 50 °C; enables clinical-grade patient thermometer designs without post-assembly calibration
Resolution16-bit output, 0.0078 °C/LSB; supports sub-millidegree thermal trend analysis in environmental monitoring
Supply Range1.8 V to 5.5 V at full –55 °C to 150 °C range; compatible with single-cell Li-ion, 3.3 V industrial rails, and 5 V legacy systems
Quiescent Current3.5 μA at 1-Hz conversion rate; extends battery life to >10 years in wireless sensor nodes with coin-cell power
Shutdown Current150 nA; allows deep-sleep operation during extended idle periods in portable medical devices
InterfaceI²C/SMBus-compatible, 400 kHz max; interoperable with standard microcontroller peripherals without protocol translation
EEPROM48-bit user-accessible memory; stores calibration offsets, device IDs, or firmware revision tags persistently

Pinout & Package

Package: DRV (WSON-6), 2.00 mm × 2.00 mm, thermally enhanced with exposed thermal pad.

Pin/TerminalCircuit RoleDesign Meaning
V+Power supply inputAccepts 1.8–5.5 V; powers internal regulator, ADC, and interface logic; requires local 100-nF decoupling
GNDGround referenceReturn path for analog and digital circuits; must be connected to thermal pad for optimal thermal performance
SCLClock inputI²C/SMBus serial clock; accepts 0–5.5 V logic levels; requires external pull-up resistor (typically 4.7 kΩ)
SDABidirectional data lineOpen-drain I/O; shares bus with up to three other TMP117 devices using ADD0 address select
ADD0Address select inputConfigures I²C slave address (0x48–0x4B); tied to GND/V+/SDA/SCL to set one of four unique addresses
ALERTOpen-drain interrupt outputAsserts on temperature threshold breach or data-ready event; requires external pull-up; supports SMBus Alert Response Protocol

Key Features

FeatureDesign Value
Medical-grade certificationFully compliant with ASTM E1112 and ISO 80601-2-56 - validated for electronic patient thermometers without additional system-level qualification
NIST-traceable calibration100% production-tested on NIST-traceable equipment calibrated to ISO/IEC 17025 standards; eliminates need for end-customer recalibration
RTD replacement capabilityMatches Class AA PT100 accuracy (±0.1 °C) while consuming <1% of typical RTD excitation power - removes need for precision current sources and matched PCB traces
Programmable averagingConfigurable 1–8 sample averaging reduces measurement noise to ±1 LSB (±0.0078 °C), enabling stable readings in electrically noisy environments
Digital offset correctionUser-writable 16-bit offset register compensates for system-level thermal gradients or PCB self-heating effects without hardware modification

Applications

Electronic ThermometersWireless Environmental Sensors

Use Scenario: Clinical and home-use contact thermometers requiring FDA-submission-ready accuracy and repeatability.

IC Role / Device Role / Timing Role: Primary temperature transducer with direct digital output; replaces analog thermistor+ADC chains and eliminates analog signal conditioning.

Use Value: Delivers ±0.1 °C accuracy from –20 °C to 50 °C out-of-box, meeting ASTM E1112 requirements without system calibration or trimming.

Use Scenario: Battery-powered outdoor air quality and humidity nodes deployed in agricultural or smart-city infrastructure.

IC Role / Device Role / Timing Role: High-stability ambient temperature reference for multi-sensor fusion; operates continuously at 1-Hz with 3.5 μA average current.

Use Value: Enables >5-year battery life on CR2032 cells while maintaining ±0.25 °C accuracy across –55 °C to 125 °C for long-term environmental logging.

Cold Chain Asset TrackingWearable Fitness Monitors

Use Scenario: Real-time temperature logging inside pharmaceutical shipping containers during global transport.

IC Role / Device Role / Timing Role: Tamper-resistant, NIST-traceable temperature logger with EEPROM-stored calibration history and alert-triggered wake-up.

Use Value: Provides audit-ready temperature records with ±0.3 °C accuracy from –55 °C to 150 °C and 48-bit user memory for batch ID and timestamp storage.

Use Scenario: Skin-contact temperature sensing in wrist-worn activity trackers and recovery monitors.

IC Role / Device Role / Timing Role: Low-self-heating thermal sensor with shutdown current of 150 nA; wakes on motion or scheduled interval to capture transient thermal responses.

Use Value: Achieves <0.05 °C measurement stability during skin contact by minimizing self-heating (<3.5 μA active current) and supporting digital offset correction for mounting variance.

Equivalent & Alternatives

The following parts are listed as comparable options for similar digital temperature sensor applications.

Alternative PartTechnical DifferenceApplication DifferenceSelection Advice
MAX30205±0.1 °C accuracy only from 37 °C to 43 °C; narrower medical range; no EEPROM; 1.7–3.6 V supplyOptimized exclusively for human-body temperature measurement; lacks wide-range industrial capabilitySelect when cost-sensitive clinical thermometers require minimal feature set and narrow operating range
ADT7420±0.25 °C accuracy from –20 °C to 85 °C; 16-bit resolution; 200 nA shutdown; no medical certification or NIST traceabilityGeneral-purpose industrial sensor; not qualified for medical device regulatory submissionsSelect for non-medical, high-resolution thermal monitoring where ASTM/ISO compliance is unnecessary

Compared with MAX30205 and ADT7420, the TMP117MAIDRVT uniquely combines full-range medical certification, NIST-traceable calibration, and integrated EEPROM - making it the only option suitable for FDA-submission-ready thermometers and regulated cold-chain validation systems.

Availability

TMP117MAIDRVT is available at Aetrix Electronics and suitable for electronic thermometers, cold chain asset tracking, and wearable fitness monitors requiring stable component supply, long-lifecycle availability, and consistent calibration traceability.

Supply support for TMP117MAIDRVT includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

Texas Instruments is a U.S.-based semiconductor company specializing in analog and embedded processing technologies, with leadership in precision sensing, power management, and industrial interface solutions.

The TMP117 product line delivers ultra-high-accuracy digital temperature sensing for medical, industrial, and environmental applications - designed specifically to replace analog RTD systems and meet stringent regulatory requirements for patient safety and data integrity.

FAQ

What is the maximum accuracy specification of the TMP117MAIDRVT across its full operating temperature range?

The TMP117MAIDRVT achieves ±0.1 °C maximum accuracy from –20 °C to 50 °C, ±0.15 °C from –40 °C to 70 °C, ±0.2 °C from –40 °C to 100 °C, ±0.25 °C from –55 °C to 125 °C, and ±0.3 °C from –55 °C to 150 °C. These values are guaranteed maximum errors under specified operating conditions and reflect factory calibration verified against NIST-traceable standards. The TMP117MAIDRVT maintains this performance without user calibration.

Does the TMP117MAIDRVT support multiple devices on the same I²C bus, and how is addressing configured?

Yes, the TMP117MAIDRVT supports up to four devices on a single I²C bus using the ADD0 pin. ADD0 accepts four logic states - GND, V+, SDA, or SCL - to configure the device's 7-bit slave address as 0x48, 0x49, 0x4A, or 0x4B respectively. This hardware-selectable addressing eliminates software-based address conflicts and enables plug-and-play expansion in multi-sensor systems without modifying firmware. Each TMP117MAIDRVT retains independent configuration and EEPROM content.

How does the TMP117MAIDRVT achieve medical-grade compliance per ASTM E1112 and ISO 80601-2-56?

The TMP117MAIDRVT achieves ASTM E1112 and ISO 80601-2-56 compliance through 100% production testing on NIST-traceable equipment calibrated to ISO/IEC 17025 standards, full-range accuracy validation (–55 °C to 150 °C), and built-in features like programmable alert limits, digital offset correction, and EEPROM-stored calibration data. Unlike generic sensors, the TMP117MAIDRVT provides documented traceability, long-term stability (±0.03 °C drift after 1000 hours at 150 °C), and repeatable performance required for FDA submission - all without requiring system-level requalification.

Can the TMP117MAIDRVT replace platinum RTDs such as PT100 or PT1000 in existing designs?

Yes, the TMP117MAIDRVT is explicitly qualified as an RTD replacement for PT100, PT500, and PT1000 sensors. It matches Class AA RTD accuracy (±0.1 °C) while eliminating the need for precision excitation current sources, matched PCB traces, cold-junction compensation, and complex linearization algorithms. With its 1.8–5.5 V supply, I²C interface, and onboard EEPROM, the TMP117MAIDRVT simplifies thermal subsystem design and reduces BOM count - delivering equivalent metrological performance at <1% of typical RTD system power consumption.

What is the role of the 48-bit EEPROM in the TMP117MAIDRVT, and how is it accessed?

The 48-bit EEPROM in the TMP117MAIDRVT provides user-programmable nonvolatile memory for storing calibration offsets, device identifiers, firmware version stamps, or manufacturing lot codes. It is accessed via standard I²C register reads/writes using dedicated EEPROM command bytes (0x50–0x55), supports 1,000–50,000 write cycles, and guarantees 10–100 years of data retention. Unlike configuration registers, EEPROM contents persist across power cycles and device resets - enabling traceable, field-updatable system calibration without external memory components. The TMP117MAIDRVT uses this memory to store factory-applied NIST-traceable calibration coefficients.

TMP117MAIDRVT Specifications

Product attributes
Attribute value
Manufacturer:
Texas Instruments
Series:
-
Package/Case:
6-WDFN Exposed Pad
Packaging:
Tape & Reel (TR)
Product Status:
Obsolete
Sensor Type:
Digital, Local
Sensing Temperature - Local:
0°C ~ 85°C
Sensing Temperature - Remote:
-
Output Type:
I2C/SMBus
Voltage - Supply:
1.8V ~ 5.5V
Resolution:
16 b
Features:
Standby Mode, Shutdown Mode, One-Shot, Programmable Limit
Accuracy - Highest (Lowest):
±0.1°C (±0.2°C)
Test Condition:
30°C ~ 45°C (0°C ~ 85°C)
Operating Temperature:
0°C ~ 85°C
Mounting Type:
Surface Mount
Grade:
-
Qualification:
-
Supplier Device Package:
6-WSON (2x2)

TMP117MAIDRVT FAQ

1.How can I place an order for TMP117MAIDRVT through Aetrix?

Please submit a Request for Quotation (RFQ) for TMP117MAIDRVT on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for TMP117MAIDRVT reliable?

The price and inventory of TMP117MAIDRVT are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for TMP117MAIDRVT is usually 5 days.

3.What payment methods are accepted for TMP117MAIDRVT?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for TMP117MAIDRVT transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for TMP117MAIDRVT?

TMP117MAIDRVT orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your TMP117MAIDRVT order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for TMP117MAIDRVT?

For technical support, including TMP117MAIDRVT datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your TMP117MAIDRVT requirements.

6.How does Aetrix verify that TMP117MAIDRVT is sourced from the original manufacturer or authorized distributors?

All TMP117MAIDRVT products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that TMP117MAIDRVT meets industry standards.

7.What is the process for return or replacement of TMP117MAIDRVT?

All TMP117MAIDRVT units undergo pre-shipment inspection (PSI). If there is an issue with TMP117MAIDRVT, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The TMP117MAIDRVT part is unused and in its original packaging.

Return procedure for TMP117MAIDRVT:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

TMP117MAIDRVT Tags

  • TMP117MAIDRVT
  • TMP117MAIDRVT PDF
  • TMP117MAIDRVT Datasheet
  • TMP117MAIDRVT Specifications
  • TMP117MAIDRVT Images
  • Texas Instruments
  • Texas Instruments TMP117MAIDRVT
  • Buy TMP117MAIDRVT
  • TMP117MAIDRVT Price
  • TMP117MAIDRVT Distributor
  • TMP117MAIDRVT Supplier
  • TMP117MAIDRVT Wholesale
Related Products
MCP9700T-E/TT
MCP9700T-E/TT

Microchip Technology

MCP9700T-E/LT
MCP9700T-E/LT

Microchip Technology

MCP9701T-E/TT
MCP9701T-E/TT

Microchip Technology

MCP9701T-E/LT
MCP9701T-E/LT

Microchip Technology

TMP235A4DBZR
TMP235A4DBZR

Texas Instruments

MCP9700AT-E/TT
MCP9700AT-E/TT

Microchip Technology

MCP9700AT-E/LT
MCP9700AT-E/LT

Microchip Technology

MCP9701AT-E/LT
MCP9701AT-E/LT

Microchip Technology

MCP9701AT-E/TT
MCP9701AT-E/TT

Microchip Technology

LM335Z
LM335Z

STMicroelectronics

TMP1075NDRLR
TMP1075NDRLR

Texas Instruments

TMP1075DGKR
TMP1075DGKR

Texas Instruments

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER