Texas Instruments TPS37F010122DSKR
- Part No.:
- TPS37F010122DSKR
- Manufacturer:
- Texas Instruments
- Category:
- Supervisors
- Package:
- 10-WFDFN Exposed Pad
- Datasheet:
-
TPS37F010122DSKR.pdf
- Description:
- 65-V WINDOW SUPERVISOR WITH ULTR
- Quantity:
- Payment:

- Shipping:

Inventory:5,929
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
TPS37F010122DSKR from Texas Instruments is a dual-channel overvoltage and undervoltage supervisor IC with independent SENSE1 (OV monitor) and SENSE2 (UV monitor), 2.7 V to 65 V supply range, 1 µA typical quiescent current, programmable sense/reset delays via external capacitors, and 65 V-rated SENSE/RESET pins. It enables robust rail monitoring in industrial servo drive power stages and functional safety modules.
For engineers reviewing the TPS37F010122DSKR datasheet, TPS37F010122DSKR pinout, TPS37F010122DSKR application, or TPS37F010122DSKR equivalent, key selection criteria include dual OV/UV detection per channel, ±1.5% threshold accuracy across –40°C to +125°C, 2%–13% programmable hysteresis, open-drain/push-pull output topology options, and WSON-10 (DSK) package compatibility with IEC60664 creepage requirements.
Technical Context
The TPS37F010122DSKR implements two independent high-voltage comparators with internal precision reference and integrated resistor dividers-enabling direct 12 V/24 V rail monitoring without external resistors. SENSE1 and SENSE2 operate decoupled from VDD, allowing SENSE pins to monitor voltages higher or lower than VDD.
It features capacitor-programmable timing: CTS1/CTS2 set sense delay (1.28 ms to 1.28 s), CTR1/CTR2 set reset delay (12.8 ms to 12.8 s), and both CTR pins double as manual reset inputs. Built-in hysteresis prevents false triggering on noisy rails, with fixed (0.5–2.5 V) or percentage-based (2–13%) options.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Supply Range | 2.7 V to 65 V - supports direct connection to industrial 24 V, 48 V, and HV auxiliary rails without level-shifting. |
| Threshold Accuracy | ±1.5% for 2.7–36 V thresholds; ±1% for 800 mV option - ensures precise fault detection across temperature (–40°C to +125°C). |
| Quiescent Current | 1 µA typical - enables always-on monitoring in battery-backed or energy-constrained systems. |
| Sense Delay Range | 1.28 ms to 1.28 s (via 10 nF–10 µF on CTS1/CTS2) - configurable debouncing for transient immunity. |
| Reset Delay Range | 12.8 ms to 12.8 s (via 10 nF–10 µF on CTR1/CTR2) - programmable hold time for controlled system recovery. |
| Pin Voltage Rating | 65 V on VDD, SENSE1, SENSE2, RESET1, RESET2 - eliminates need for external clamping in 60 V-class applications. |
| Hysteresis Options | Fixed: 0.5 V / 1 V / 1.5 V / 2 V / 2.5 V (for VTH < 8 V); Percentage: 2%–13% in 1% steps - prevents chatter during slow-ramp or noisy supply transitions. |
Pinout & Package
TPS37F010122DSKR is packaged in a 10-pin WSON (DSK) with 2.5 mm × 2.5 mm body size and non-conductive thermal pad for enhanced creepage per IEC60664 between VDD and GND.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| VDD | Power input | Supplies internal circuitry; bypass with 0.1 µF capacitor to GND; operates from 2.7 V to 65 V. |
| SENSE1 | OV monitor input | Triggers RESET1 assertion when voltage exceeds upper threshold (VIT+); supports direct 24 V/48 V rail sensing. |
| SENSE2 | UV monitor input | Triggers RESET2 assertion when voltage falls below lower threshold (VIT−); independently configurable from SENSE1. |
| GND | Ground reference | Common return for all internal circuits; all GND pins must be electrically connected to PCB ground plane. |
| CTR1/MR | Channel 1 reset delay & manual reset | Capacitor-connected for adjustable reset delay; driven low to force immediate RESET1 assertion. |
| CTR2/MR | Channel 2 reset delay & manual reset | Capacitor-connected for adjustable reset delay; driven low to force immediate RESET2 assertion. |
| CTS1 | Channel 1 sense delay | Capacitor-connected to ground to set programmable debounce time before RESET1 assertion. |
| CTS2 | Channel 2 sense delay | Capacitor-connected to ground to set programmable debounce time before RESET2 assertion. |
| RESET1_OVOD | Overvoltage reset output | Open-drain active-low output for SENSE1 OV event; requires external pull-up for logic-level compatibility. |
| RESET2_UVOD | Undervoltage reset output | Open-drain active-low output for SENSE2 UV event; shares same topology and drive capability as RESET1. |
Key Features
| Feature | Design Value |
|---|---|
| Dual independent OV/UV supervision | SENSE1 monitors overvoltage; SENSE2 monitors undervoltage - enables full window detection with separate timing and thresholds. |
| 65 V-rated SENSE/RESET pins | Eliminates external voltage clamping components when monitoring 48 V or 60 V rails directly. |
| Programmable sense & reset delays | CTS/CTR pins accept 10 nF–10 µF capacitors to set delays from milliseconds to seconds - replaces fixed-timing RC networks. |
| Integrated resistor dividers | Removes need for external divider resistors in standard 12 V/24 V monitoring - reduces BOM count and leakage error. |
| Functional safety capable | Documentation available for ISO 26262 and IEC 61508 system-level safety design - supports diagnostic coverage analysis. |
Applications
| Industrial Servo Drive Power Stage | PLC CPU Module Supervision |
|---|---|
Use Scenario: Monitors DC bus voltage in servo amplifier stage to detect overvoltage faults during regenerative braking or undervoltage during line sag. IC Role / Device Role / Timing Role: Dual-channel supervisor asserting independent RESET1 (OV) and RESET2 (UV) signals to gate driver shutdown logic with programmable delay. Use Value: Prevents IGBT damage by enforcing safe shutdown within 1.28 ms–12.8 s windows, configurable per fault severity. | Use Scenario: Ensures reliable boot and runtime operation of PLC controller MCU by validating 5 V or 3.3 V LDO outputs under load transients. IC Role / Device Role / Timing Role: Uses SENSE2 to track LDO output (UV detection) and SENSE1 to monitor backup rail (OV detection), with manual reset via CTR pins. Use Value: Guarantees deterministic reset behavior across –40°C to +125°C with ±1.5% threshold accuracy and no external resistors required. |
| HVAC Actuator Control Unit | Factory Automation Analog Input Module |
Use Scenario: Supervises 24 V supply powering motorized valve drivers and position feedback sensors in HVAC field devices. IC Role / Device Role / Timing Role: SENSE1 detects overvoltage from inductive kickback; SENSE2 detects brownout during shared power distribution; CTS1/CTS2 suppress noise-induced false triggers. Use Value: Enables >10-year field reliability with 1 µA quiescent current and 65 V pin rating - no derating needed for 24 V nominal systems. | Use Scenario: Validates isolated 12 V or 24 V sensor excitation rails in analog input cards used for current/voltage measurement. IC Role / Device Role / Timing Role: Dual-channel monitoring allows simultaneous validation of primary and redundant excitation supplies with independent reset signaling. Use Value: Supports SIL-2 functional safety architecture by providing two independent fault channels with documented failure modes and FIT data. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar dual-channel overvoltage and undervoltage detection applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| TPS3700DSCR | Single-channel, 2.7–65 V, identical timing and threshold specs but no second SENSE/RESET path. | Requires two devices to replicate dual-channel functionality; increases board area and BOM count. | Select only when single-rail monitoring suffices and cost-per-channel is prioritized over integration. |
| TLV809EADBZR | Single-channel 3.0 V fixed-threshold supervisor; 1.8–6 V supply; no programmable delay; no 65 V pin rating. | Limited to low-voltage logic rails; cannot monitor 24 V/48 V directly; lacks hysteresis programming. | Use only for sub-6 V digital supply supervision where high-voltage tolerance and dual-channel capability are unnecessary. |
Compared with TPS3700DSCR and TLV809EADBZR, the TPS37F010122DSKR delivers true dual-rail window supervision in one WSON-10 package, eliminating inter-device timing skew, reducing PCB footprint by 40%, and enabling coordinated OV/UV response with shared delay components - critical for functional safety and compact industrial designs.
Availability
TPS37F010122DSKR is available at Aetrix Electronics and suitable for industrial servo drives, PLC CPU modules, and HVAC actuator control requiring stable component supply with extended temperature support and functional safety documentation.
Supply support for TPS37F010122DSKR includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Texas Instruments is a global semiconductor leader specializing in analog, embedded processing, and high-reliability power management solutions for industrial, automotive, and communications markets.
The TPS37 family is designed for high-voltage, low-quiescent-current supervision in factory automation, motor drives, and building control systems - emphasizing rail independence, programmable timing, and IEC60664-compliant isolation.
FAQ
What is the operating temperature range for the TPS37F010122DSKR?
The TPS37F010122DSKR operates across an ambient temperature range of –40°C to +125°C, validated per its recommended operating conditions. This range supports deployment in demanding industrial environments such as servo drive power stages and HVAC actuators where thermal extremes are common. All electrical characteristics-including threshold accuracy, quiescent current, and timing parameters-are specified over this full range. The device's thermal metrics (e.g., RθJA = 87.4°C/W for DSK package) further confirm suitability for convection-cooled PCB layouts without forced airflow.
Does the TPS37F010122DSKR require external resistors for standard 24 V rail monitoring?
No, the TPS37F010122DSKR does not require external resistors for standard 24 V rail monitoring. It integrates precision resistor dividers optimized for common industrial supply voltages, enabling direct connection of SENSE1 and SENSE2 to 12 V or 24 V rails. This eliminates BOM cost, layout area, and leakage-induced accuracy drift associated with discrete dividers. External resistors are supported only for custom thresholds (e.g., 800 mV option), where lower input current and faster detection are prioritized.
How are the reset delay and sense delay configured on the TPS37F010122DSKR?
The TPS37F010122DSKR uses external capacitors on CTR1/CTR2 (reset delay) and CTS1/CTS2 (sense delay) pins to configure timing. For example, a 10 nF capacitor yields 12.8 ms reset delay and 1.28 ms sense delay; scaling to 10 µF extends both to 12.8 s and 1.28 s respectively. Internal timing resistors (RCTR ≈ 1 MΩ, RCTS ≈ 100 kΩ) define the linear relationship. Capacitors must be grounded, ceramic, and placed close to the pins for stability. No external resistors or clocks are needed - simplifying design versus RC or timer-based alternatives.
What output topologies does the TPS37F010122DSKR support?
The TPS37F010122DSKR supports both open-drain and push-pull output topologies for RESET1_OVOD and RESET2_UVOD, selectable at purchase via part number suffix. Open-drain outputs require an external pull-up resistor for logic-level translation and wired-OR capability; push-pull outputs drive high/low actively without external components. Both topologies support active-low or active-high logic polarity, enabling direct interface with MCU reset inputs, FPGA configuration pins, or gate driver enable signals without level shifters.
Is the TPS37F010122DSKR suitable for functional safety–certified systems?
Yes, the TPS37F010122DSKR is functional safety–capable, with documentation available to support system-level design per ISO 26262 (ASIL-B) and IEC 61508 (SIL-2). Its dual independent channels, predictable timing behavior, failure mode and effects analysis (FMEA) data, and diagnostic coverage guidance enable integration into safety-critical subsystems like servo drive functional safety modules. However, final certification depends on system-level implementation - TI provides the foundational evidence, but end-equipment validation remains the responsibility of the integrator.
TPS37F010122DSKR Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Texas Instruments
- Series:
- -
- Package/Case:
- 10-WFDFN Exposed Pad
- Packaging:
- Tape & Reel (TR)
- Product Status:
- Active
- Programmable:
- Not Verified
- Type:
- Voltage Detector
- Number of Voltages Monitored:
- 2
- Voltage - Threshold:
- 0.8V, 0.8V
- Output:
- Open Drain, Open Drain
- Reset:
- Active High/Active Low
- Reset Timeout:
- 100µs Maximum
- Operating Temperature:
- -40°C ~ 125°C (TJ)
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- 10-WSON (2.5x2.5)
TPS37F010122DSKR FAQ
1.How can I place an order for TPS37F010122DSKR through Aetrix?
Please submit a Request for Quotation (RFQ) for TPS37F010122DSKR on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for TPS37F010122DSKR reliable?
The price and inventory of TPS37F010122DSKR are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for TPS37F010122DSKR is usually 5 days.
3.What payment methods are accepted for TPS37F010122DSKR?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for TPS37F010122DSKR transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for TPS37F010122DSKR?
TPS37F010122DSKR orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your TPS37F010122DSKR order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for TPS37F010122DSKR?
For technical support, including TPS37F010122DSKR datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your TPS37F010122DSKR requirements.
6.How does Aetrix verify that TPS37F010122DSKR is sourced from the original manufacturer or authorized distributors?
All TPS37F010122DSKR products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that TPS37F010122DSKR meets industry standards.
7.What is the process for return or replacement of TPS37F010122DSKR?
All TPS37F010122DSKR units undergo pre-shipment inspection (PSI). If there is an issue with TPS37F010122DSKR, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The TPS37F010122DSKR part is unused and in its original packaging.
Return procedure for TPS37F010122DSKR:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
TPS37F010122DSKR Tags

-
MIC826SYMT-TR
Microchip Technology

-
APX803S-31SA-7
Diodes Incorporated

-
APX803L20-29SA-7
Diodes Incorporated
-
TPS3828-33DBVR
Texas Instruments

-
V6340RSP3B+
EM Microelectronic

-
EM6325CXSP5B-2.9+
EM Microelectronic

-
MCP120T-300I/TT
Microchip Technology

-
MCP130T-315I/TT
Microchip Technology

-
MCP120T-475I/TT
Microchip Technology

-
MCP111T-300E/TT
Microchip Technology

-
MCP120T-315I/TT
Microchip Technology

-
MCP809T-315I/TT
Microchip Technology
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…