Diodes Incorporated TRAC-S2Q16
- Part No.:
- TRAC-S2Q16
- Manufacturer:
- Diodes Incorporated
- Category:
- Specialized ICs
- Package:
- 16-SSOP (0.154", 3.90mm Width)
- Datasheet:
-
TRAC-S2Q16.pdf
- Description:
- IC SUPPORT CIRCUIT 16QSOP
- Quantity:
- Payment:

- Shipping:

Inventory:3,932
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
TRAC-S2Q16 from Zetex plc is a TRAC® Support Circuit designed to automate power-up programming of Totally Reconfigurable Analog Circuit (TRAC) devices. It integrates rail-splitting (AGND_OUT adjustable from 2.0V–2.5V), supply monitoring (4.35V–4.75V reset threshold), on-chip programmable oscillator (7–15 kHz CLK_OUT), DATA_OUT (1.7–4.0 kHz), and thermal shutdown. Used with serial EEPROMs like ST9346CB1 in analog signal processing prototyping systems.
For engineers reviewing the TRAC-S2Q16 datasheet, TRAC-S2Q16 pinout, TRAC-S2Q16 application, or TRAC-S2Q16 equivalent, this device serves as a dedicated support IC for TRAC-family analog FPGA-like reconfiguration - requiring precise AGND generation, synchronized reset, and cascaded memory-driven loading logic.
Technical Context
The TRAC-S2Q16 implements a structured analog system boot architecture: its rail-splitter uses an external SETV divider to define AGND_OUT (±20 mA drive), enabling biasing of multiple TRAC devices; the supply monitor employs a precision ZSM560-based circuit to assert RESET_OUT during VDD ramp-up or dropout, ensuring deterministic initialization across the TRAC chain.
Its programming logic generates CLK_OUT and NOT CLK_OUT (inverted) at user-set frequency via external capacitor, divides CLK_OUT by four to produce DATA_OUT, and asserts SELECT to enable serial EEPROM - all gated by CLCR_IN feedback from the final TRAC device to halt clocking automatically upon load completion.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Supply Voltage Range | 4.8V–5.2V operating range ensures stable operation under typical 5V ±2% industrial rails. |
| AGND_OUT Voltage Accuracy | ±10 mV at 2.50V setpoint (no load) enables precise analog reference for TRAC bias networks. |
| RESET_OUT Threshold | 4.35V (rising), 4.75V (falling) with 40 mV hysteresis guarantees robust power-fail detection and clean reset assertion. |
| CLK_OUT Frequency | 7–15 kHz (2.2 nF cap) sets reliable EEPROM clock rate compatible with 93LC46B/NM92C46 timing. |
| DATA_OUT Frequency | 1.7–4.0 kHz (CLK_OUT ÷ 4) delivers correct serial bitstream timing for TRAC configuration data loading. |
| Thermal Shutdown | Activates to disable outputs when die temperature exceeds safe limit, preventing latch-up during fault conditions. |
| Operating Temperature | –40°C to +85°C supports deployment in industrial control and embedded instrumentation environments. |
Pinout & Package
TRAC-S2Q16 is housed in a 16-pin QSOP package (4.80 mm × 3.81 mm body, 0.635 mm pitch), optimized for high-density analog PCB layouts with low thermal resistance and minimal parasitic coupling.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| SETV | Analog ground reference input | Voltage divider input setting AGND_OUT level (2.0–2.5 V); high-impedance (≤200 nA) for minimal loading. |
| CLCR_IN | Programming completion feedback input | Active-high signal from last TRAC device; disables CLK_OUT/DATA_OUT/SELECT when pulled low post-load. |
| CAP | Oscillator frequency tuning node | Connects external capacitor (2.2 nF typical) to VSS to set CLK_OUT frequency per datasheet curve. |
| AGND_OUT | Programmable analog ground output | Sinks/sources ±20 mA; requires 100 nF decoupling to VSS for stability under dynamic TRAC loading. |
| SELECT | Serial memory chip-select output | Active-high enable for EEPROM (e.g., 93LC46B); asserted only during CLK_OUT activity. |
| CLK_OUT | EEPROM clock output | Drives EEPROM SCK pin; 7–15 kHz range matches standard microwire-compatible memory timing. |
| NOT CLK_OUT | Inverted clock output | Feeds TRAC device clock input; phase-aligned inverse of CLK_OUT for synchronous sampling. |
| DATA_OUT | Serialized configuration data output | CLK_OUT ÷ 4 signal driving EEPROM SO pin; provides bitstream timing for TRAC program loading. |
| RESET_OUT | System reset output | Open-drain reset signal (4.35–4.75 V threshold) asserting reset to TRAC and support circuitry on power events. |
Key Features
| Feature | Design Value |
|---|---|
| Adjustable rail-splitter | AGND_OUT settable from 2.0 V to 2.5 V via external resistor divider, supporting dual-supply TRAC biasing. |
| Auto-stopping clock logic | CLCR_IN feedback halts CLK_OUT/DATA_OUT/SELECT immediately after TRAC load completion, eliminating wasted cycles. |
| Power-fail reset recovery | Supply monitor re-triggers full TRAC reload after brownout or VDD dip >100 ms, ensuring deterministic state restoration. |
| Thermal protection | Internal thermal shutdown disables outputs before junction temperature exceeds safe limit, preventing damage during overcurrent faults. |
| Industrial temperature range | Guaranteed operation from –40°C to +85°C enables use in factory automation, test equipment, and outdoor instrumentation. |
Applications
| Automated Analog Prototyping | Reconfigurable Sensor Signal Conditioning |
|---|---|
Use Scenario: Rapid iteration of analog front-ends for sensor evaluation boards using TRAC devices. IC Role / Device Role / Timing Role: TRAC-S2Q16 acts as the boot controller, generating AGND, clock, reset, and memory select signals to load TRAC configuration from EEPROM on power-up. Use Value: Eliminates manual jumper settings and external clock generators, reducing prototype build time from hours to minutes. | Use Scenario: Field-deployable environmental monitoring nodes with adaptive gain/offset calibration per sensor type. IC Role / Device Role / Timing Role: Provides stable split-rail analog ground and synchronized reset to TRAC devices performing real-time filter/gain reconfiguration. Use Value: Enables field-upgradable analog behavior without hardware changes - AGND_OUT accuracy (±10 mV) preserves measurement integrity. |
| Industrial PLC I/O Module Calibration | Medical Instrumentation Front-End |
Use Scenario: Modular analog input cards in programmable logic controllers requiring traceable calibration coefficients. IC Role / Device Role / Timing Role: Loads TRAC-programmed calibration curves from EEPROM into analog signal paths during cold start or firmware update. Use Value: RESET_OUT hysteresis (40 mV) prevents spurious resets during noisy industrial power transients, ensuring reliable calibration load. | Use Scenario: Low-noise ECG/EEG acquisition systems needing configurable anti-aliasing and amplification stages. IC Role / Device Role / Timing Role: Supplies precision AGND_OUT (2.50 V ±10 mV) and noise-isolated clocks to TRAC devices implementing patient-isolated analog filters. Use Value: 100 nF AGND_OUT–VSS decoupling requirement ensures PSRR >60 dB at 1 kHz, critical for microvolt-level bio-signal fidelity. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar TRAC support circuit applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| ZXTR2005Q16 | Single-rail 5V-only operation; no rail-splitter or AGND_OUT output; fixed 10 kHz oscillator. | Lacks analog ground generation and programmable clock - suitable only for digital TRAC variants with external biasing. | Select only if TRAC design uses externally derived AGND and fixed-frequency loading. |
| MAX16052ATT+T | Supervisory IC with reset only; no clock generation, rail-splitting, or memory interface logic. | Provides reset functionality only - requires discrete oscillator, level shifters, and EEPROM interface circuitry. | Choose only when full TRAC-S2 functionality is unnecessary and board space permits added discrete components. |
Compared with ZXTR2005Q16 and MAX16052ATT+T, TRAC-S2Q16 uniquely integrates rail-splitting, programmable clocking, and memory interface logic - eliminating ≥7 external components required by alternatives to achieve identical TRAC boot functionality.
Availability
TRAC-S2Q16 is available at Aetrix Electronics and suitable for automated analog prototyping, reconfigurable sensor signal conditioning, and industrial PLC I/O module calibration requiring stable component supply and long-term obsolescence management.
Supply support for TRAC-S2Q16 includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Zetex plc (now part of Diodes Incorporated) was a UK-based analog semiconductor specialist focused on high-performance discrete and interface ICs for industrial and automotive markets.
TRAC-S2 belongs to Zetex's TRAC® Support Circuit product line, engineered specifically to accelerate analog system development by automating configuration loading, bias generation, and fault-safe initialization of field-programmable analog arrays.
FAQ
What capacitor value sets the default CLK_OUT frequency?
A 2.2 nF capacitor between CAP and VSS yields a nominal CLK_OUT frequency of 10 kHz at 25°C, per the datasheet's electrical characteristics table. Frequency varies linearly with capacitance - halving the cap doubles frequency, and vice versa. The capacitor must be ceramic with tight tolerance (±10%) for repeatable timing across units.
Can TRAC-S2Q16 support more than one TRAC device in cascade?
Yes - TRAC-S2Q16 is explicitly designed for cascaded TRAC configurations. Its CLCR_IN input monitors the final TRAC's load-complete signal, and its rail-splitter delivers ±20 mA to power up to four TRAC devices plus associated circuitry. The datasheet confirms automatic clock termination regardless of cascade depth.
Is AGND_OUT capable of sourcing and sinking current simultaneously?
No - AGND_OUT operates as a single-ended analog ground reference that can source or sink up to 20 mA, but not both at once. Its output stage is a Class-A buffer with low output impedance (<1 Ω), allowing it to maintain voltage stability under unidirectional load transients typical in TRAC bias networks.
Does TRAC-S2Q16 require external pull-up resistors on open-drain pins?
Only RESET_OUT is open-drain; it requires an external pull-up resistor (typically 10 kΩ to VDD) to generate a valid logic-high reset signal. All other outputs (CLK_OUT, NOT CLK_OUT, DATA_OUT, SELECT) are push-pull and do not require external terminations. The datasheet specifies RESET_OUT sink current capability of 0.14 mA at 4 V.
TRAC-S2Q16 Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Diodes Incorporated
- Series:
- -
- Package/Case:
- 16-SSOP (0.154", 3.90mm Width)
- Packaging:
- Bulk
- Product Status:
- Obsolete
- Programmable:
- Not Verified
- Type:
- Support Circuit
- Applications:
- -
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- 16-QSOP
- Grade:
- -
- Qualification:
- -
TRAC-S2Q16 FAQ
1.How can I place an order for TRAC-S2Q16 through Aetrix?
Please submit a Request for Quotation (RFQ) for TRAC-S2Q16 on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for TRAC-S2Q16 reliable?
The price and inventory of TRAC-S2Q16 are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for TRAC-S2Q16 is usually 5 days.
3.What payment methods are accepted for TRAC-S2Q16?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for TRAC-S2Q16 transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for TRAC-S2Q16?
TRAC-S2Q16 orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your TRAC-S2Q16 order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for TRAC-S2Q16?
For technical support, including TRAC-S2Q16 datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your TRAC-S2Q16 requirements.
6.How does Aetrix verify that TRAC-S2Q16 is sourced from the original manufacturer or authorized distributors?
All TRAC-S2Q16 products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that TRAC-S2Q16 meets industry standards.
7.What is the process for return or replacement of TRAC-S2Q16?
All TRAC-S2Q16 units undergo pre-shipment inspection (PSI). If there is an issue with TRAC-S2Q16, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The TRAC-S2Q16 part is unused and in its original packaging.
Return procedure for TRAC-S2Q16:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
TRAC-S2Q16 Tags

-
CAP200DG-TL
Power Integrations

-
ATSHA204A-MAHDA-T
Microchip Technology

-
ATSHA204A-SSHDA-T
Microchip Technology

-
ATSHA204A-STUCZ-T
Microchip Technology
-
ATECC608B-MAHDA-T
Microchip Technology
-
ATECC608B-MAHCZ-S
Microchip Technology

-
ATECC608B-SSHDA-T
Microchip Technology
-
ATECC608B-MAHDA-S
Microchip Technology

-
ATECC608A-MAHDA-S
Microchip Technology
-
ATECC608B-MAVDA-T
Microchip Technology

-
ATECC608A-SSHDA-T
Microchip Technology

-
ATECC508A-MAHDA-T
Microchip Technology
Tech Hub
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…
LDO regulator guide covering low dropout voltage, power dissipation, thermal design, PSRR, output noise, capacitor stability, adjustable LDO circuits, LDO vs buck converter and datasheet selection chec…
Conditional Access Module guide covering CAM meaning, CI/CI+ interface, smart card authorization, DVB security workflow, TV and set-top box compatibility, internal electronics, ESD protection, connecto…
Guide to electronic component obsolescence covering EOL risk, PCN/PDN notices, last-time buy planning, replacement options, form-fit-function validation, counterfeit risk and BOM lifecycle management.
18650 battery guide covering lithium-ion cell basics, 3.6V/3.7V voltage, 4.2V charging, mAh and Wh capacity, protected cells, chargers, BMS, series-parallel packs, holders, welding and sourcing checks.…
Hall effect sensor guide covering working principle, linear and digital sensors, Arduino circuits, current sensing, speed detection, automotive applications, A3144 examples, signal filtering and datash…
Product Change Notification guide for electronic components, covering PCN meaning, PCN vs PDN/EOL, common change types, risk levels, form-fit-function review, engineering validation, BOM control, LTB/L…
A practical guide to blend door actuators, covering HVAC function, symptoms, location, AC and heater issues, reset and calibration, replacement cost, electrical diagnosis, compatibility checks, and rep…