STMicroelectronics X-NUCLEO-IOD02A1
- Part No.:
- X-NUCLEO-IOD02A1
- Manufacturer:
- STMicroelectronics
- Package:
- Datasheet:
-
X-NUCLEO-IOD02A1.pdf
- Description:
- EVAL BOARD FOR STM32
- Quantity:
- Payment:

- Shipping:

Inventory:1,260
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
X-NUCLEO-IOD02A1 from STMicroelectronics is an industrial dual-channel IO-Link and SIO device expansion board based on the L6364Q transceiver, featuring SPI/UART interfaces, integrated 3.3 V/5.0 V linear regulators, a 50 mA adjustable buck converter (5.0–10.8 V), wake-up detection, and interrupt diagnostics - used for rapid evaluation of IO-Link sensor communication in factory automation systems.
For engineers reviewing the X-NUCLEO-IOD02A1 datasheet, X-NUCLEO-IOD02A1 pinout, X-NUCLEO-IOD02A1 application, or X-NUCLEO-IOD02A1 equivalent, this board enables hands-on validation of IO-Link PHY layer compliance, M-sequence handling, robustness against ESD (±3 kV contact), surge (±1.2 kV), and conducted/radiated immunity per IEC 61000-4-x standards.
Technical Context
The X-NUCLEO-IOD02A1 implements full IO-Link Class A physical layer with two independent channels (CQ and DIO), supporting both Multi-byte/Single-byte and Transparent modes via SPI-configurable operation and UART-based sensor data tunneling. It embeds hardware-level wake-up detection and diagnostic interrupt signaling directly tied to L6364Q status flags.
Power architecture includes three regulated outputs: fixed 3.3 V and 5.0 V LDOs (50 mA each) and an adjustable buck converter (5.0–10.8 V, 50 mA), all protected against overload, overtemperature (adjustable shutdown threshold), reverse polarity, and wire-break faults on process-side terminals.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| IO-Link Channels | 2 independent CQ/DIO channels compliant with IO-Link v1.1 physical layer (Class A) |
| Operating Voltage Range | 5–35 V DC input - supports wide industrial supply rails including 24 V nominal systems |
| Regulated Outputs | 3.3 V/5.0 V LDOs (50 mA each) + adjustable buck (5.0–10.8 V, 50 mA) for flexible sensor powering |
| Communication Interfaces | SPI (configuration & control) + UART (Transparent mode sensor data tunneling) |
| EMC Immunity | ESD ±3 kV (contact), Surge ±1.2 kV (500 Ω), Conducted 10 V (150 kHz–80 MHz), RF fields ≤10 V/m (80 MHz–1 GHz) |
| Physical Package | QFN-20L (4 × 4 × 0.9 mm) - compact footprint for space-constrained industrial modules |
| LED Indicators | Red and green LEDs for real-time status diagnostics (power, communication, fault) |
Availability
X-NUCLEO-IOD02A1 is available at Aetrix Electronics and suitable for factory automation prototyping, IO-Link sensor module development, and STM32-based industrial edge node design requiring stable component supply and rapid time-to-evaluation.
Supply support for X-NUCLEO-IOD02A1 includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
STMicroelectronics is a global semiconductor leader specializing in microcontrollers, analog ICs, power management, and industrial interface solutions - headquartered in Geneva, Switzerland.
This board belongs to ST's X-NUCLEO ecosystem for STM32 Nucleo expansion, designed specifically to accelerate IO-Link device development with plug-and-play compatibility, Arduino UNO R3 and ST morpho headers, and direct integration with STM32Cube software stacks.
FAQ
What microcontrollers is the X-NUCLEO-IOD02A1 compatible with?
The board is natively compatible with STM32 Nucleo development boards including NUCLEO-L073RZ and NUCLEO-G071RB. It connects via Arduino UNO R3 headers (default) or ST morpho headers (optional, requires jumper configuration). Communication uses SPI and GPIO pins mapped to standard STM32 peripherals - no external level-shifting required.
Does the board support both IO-Link and SIO protocols?
Yes - it supports full IO-Link v1.1 (including Multi-byte, Single-byte, and Transparent modes) and legacy SIO (Single Input/Output) operation. Mode selection is controlled via onboard jumpers and SPI register configuration, enabling evaluation of both modern and legacy industrial fieldbus sensor interfaces on one platform.
How is power delivered to the IO-Link device side?
The board supplies the IO-Link device side (CQ/DIO) through its L6364Q transceiver using either the internal buck converter (adjustable 5.0–10.8 V output) or external 24 V process-side input. Reverse polarity protection, ground/VCC wire-break detection, and adjustable overload thresholds ensure safe operation in harsh industrial environments.
Can the X-NUCLEO-IOD02A1 be used with other sensor expansion boards?
Yes - it is designed to interoperate with ST's X-NUCLEO-IKS02A1 motion and environmental sensor shield. The two boards can be stacked to create a complete IO-Link sensor node: IKS02A1 provides sensing (accelerometer, gyroscope, temperature, humidity), while IOD02A1 handles IO-Link physical layer, protocol stack, and industrial-grade power delivery.
X-NUCLEO-IOD02A1 Specifications
- Product attributes
- Attribute value
- Manufacturer:
- STMicroelectronics
- Series:
- -
- Packaging:
- Bulk
- Product Status:
- Active
- Type:
- Interface
- Function:
- GPIO Expander
- Embedded:
- -
- Utilized IC / Part:
- STM32
- Primary Attributes:
- -
- Secondary Attributes:
- -
- Contents:
- Board(s)
X-NUCLEO-IOD02A1 FAQ
1.How can I place an order for X-NUCLEO-IOD02A1 through Aetrix?
Please submit a Request for Quotation (RFQ) for X-NUCLEO-IOD02A1 on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for X-NUCLEO-IOD02A1 reliable?
The price and inventory of X-NUCLEO-IOD02A1 are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for X-NUCLEO-IOD02A1 is usually 5 days.
3.What payment methods are accepted for X-NUCLEO-IOD02A1?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for X-NUCLEO-IOD02A1 transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for X-NUCLEO-IOD02A1?
X-NUCLEO-IOD02A1 orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your X-NUCLEO-IOD02A1 order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for X-NUCLEO-IOD02A1?
For technical support, including X-NUCLEO-IOD02A1 datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your X-NUCLEO-IOD02A1 requirements.
6.How does Aetrix verify that X-NUCLEO-IOD02A1 is sourced from the original manufacturer or authorized distributors?
All X-NUCLEO-IOD02A1 products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that X-NUCLEO-IOD02A1 meets industry standards.
7.What is the process for return or replacement of X-NUCLEO-IOD02A1?
All X-NUCLEO-IOD02A1 units undergo pre-shipment inspection (PSI). If there is an issue with X-NUCLEO-IOD02A1, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The X-NUCLEO-IOD02A1 part is unused and in its original packaging.
Return procedure for X-NUCLEO-IOD02A1:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
X-NUCLEO-IOD02A1 Tags
-
BOB-12009
SparkFun Electronics

-
106990290
Seeed Technology Co., Ltd
-
BOB-11771
SparkFun Electronics

-
BOB-09118
SparkFun Electronics

-
4410
Adafruit Industries LLC

-
5335
Adafruit Industries LLC
-
BOB-11189
SparkFun Electronics

-
3295
Adafruit Industries LLC

-
3421
Adafruit Industries LLC

-
1904
Adafruit Industries LLC

-
2717
Adafruit Industries LLC

-
3190
Adafruit Industries LLC
Tech Hub
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…
LDO regulator guide covering low dropout voltage, power dissipation, thermal design, PSRR, output noise, capacitor stability, adjustable LDO circuits, LDO vs buck converter and datasheet selection chec…
Conditional Access Module guide covering CAM meaning, CI/CI+ interface, smart card authorization, DVB security workflow, TV and set-top box compatibility, internal electronics, ESD protection, connecto…
Guide to electronic component obsolescence covering EOL risk, PCN/PDN notices, last-time buy planning, replacement options, form-fit-function validation, counterfeit risk and BOM lifecycle management.
18650 battery guide covering lithium-ion cell basics, 3.6V/3.7V voltage, 4.2V charging, mAh and Wh capacity, protected cells, chargers, BMS, series-parallel packs, holders, welding and sourcing checks.…
Hall effect sensor guide covering working principle, linear and digital sensors, Arduino circuits, current sensing, speed detection, automotive applications, A3144 examples, signal filtering and datash…
Product Change Notification guide for electronic components, covering PCN meaning, PCN vs PDN/EOL, common change types, risk levels, form-fit-function review, engineering validation, BOM control, LTB/L…
A practical guide to blend door actuators, covering HVAC function, symptoms, location, AC and heater issues, reset and calibration, replacement cost, electrical diagnosis, compatibility checks, and rep…

