Send an Inquiry

To receive a quote for your project, please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Part Number*
Quantity*
Message
Submit Inventory List

Please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Upload My List
Message

STMicroelectronics X-NUCLEO-OUT01A1

Part No.:
X-NUCLEO-OUT01A1
Manufacturer:
STMicroelectronics
Category:
Expansion Boards, Daughter Cards
Package:
Datasheet:
AetrixX-NUCLEO-OUT01A1.pdf
Description:
NUCLEO BOARD ISO8200BQ
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:3,705

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

X-NUCLEO-OUT01A1 from STMicroelectronics is an industrial digital output expansion board based on the ISO8200BQ galvanically isolated octal high-side smart power solid-state relay, operating from 10.5 V to 33 V with 700 mA max per channel, status LEDs for fault and thermal protection, and Arduino® UNO R3 connector compatibility for STM32 Nucleo boards including NUCLEO-F103RB, F302R8, and F401RE.

For engineers reviewing the X-NUCLEO-OUT01A1 datasheet, X-NUCLEO-OUT01A1 pinout, X-NUCLEO-OUT01A1 application, or X-NUCLEO-OUT01A1 equivalent, this board enables rapid prototyping of industrial PLC I/O subsystems with galvanic isolation, EMC-compliant output switching (IEC61000-4-2/3/5), and seamless integration with X-NUCLEO-PLC01A1 and X-NUCLEO-IDW01M1 for full remote-managed PLC solutions.

Technical Context

The board implements eight independently controlled, galvanically isolated high-side outputs using the ISO8200BQ, which integrates power MOSFETs, protection circuitry, and diagnostic feedback in a single package. Each channel supports up to 700 mA continuous load current and features overtemperature shutdown and fault reporting via dedicated FAULT pin.

Control interface uses parallel 8-bit input (ISO_IN1–ISO_IN8), synchronous LOAD/EN/SYNC signals, and status feedback via FAULT and thermal indicators. Power domains are separated: digital supply (7–12 V) for logic and analog supply (10.5–33 V) for output loads, ensuring robust noise immunity in industrial environments.

Key Specifications

Parameter Value and Actual Design Meaning
Output Channels 8 independent galvanically isolated high-side outputs
Max Output Current 700 mA per channel - supports industrial solenoids, contactors, and indicator lamps
Supply Voltage Range 10.5 V to 33 V analog supply - compatible with standard 24 V DC industrial rails
Digital Interface Parallel 8-bit control + LOAD/EN/SYNC - enables deterministic timing without microcontroller firmware overhead
EMC Compliance IEC61000-4-2 (8 kV contact), -4-3 (4 kV), -4-5 (2 kV) - validated for harsh industrial environments
Connector Standard Arduino® UNO R3 footprint - ensures plug-and-play compatibility with STM32 Nucleo development ecosystem

Availability

X-NUCLEO-OUT01A1 is available at Aetrix Electronics and suitable for industrial PLC prototyping, factory automation I/O expansion, remote-controlled machinery interfaces, and embedded control systems requiring stable component supply and long-term design-in support.

Supply support for X-NUCLEO-OUT01A1 includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

STMicroelectronics is a global semiconductor leader headquartered in Geneva, designing and manufacturing microcontrollers, power ICs, sensors, and development tools for industrial, automotive, and consumer applications.

The X-NUCLEO series targets rapid evaluation and system-level prototyping of STM32-based industrial control solutions, emphasizing interoperability, EMC robustness, and modular scalability across PLC, HMI, and IoT edge nodes.

FAQ

What microcontrollers is the X-NUCLEO-OUT01A1 compatible with?

The board is designed for STM32 Nucleo development boards with Arduino® UNO R3 connectors, specifically validated with NUCLEO-F103RB, NUCLEO-F302R8, and NUCLEO-F401RE. It communicates via GPIO-controlled parallel signals (ISO_IN1–ISO_IN8, LOAD, EN, SYNC) and requires no special drivers or HAL dependencies.

Does the board provide galvanic isolation between MCU and output loads?

Yes - each of the eight output channels uses the ISO8200BQ, which integrates reinforced galvanic isolation rated to 5 kVRMS per UL 1577 and 3.75 kVRMS per IEC 60747-5-5. This isolates the STM32 logic domain (3.3 V/5 V) from industrial 24 V DC load circuits, preventing ground loops and noise coupling.

How is fault detection implemented on this board?

Fault detection is handled by the ISO8200BQ's integrated diagnostics: overtemperature shutdown triggers a common FAULT pin assertion, and individual channel faults (overload, short-circuit) are indicated via status LEDs. The FAULT signal is routed to the Nucleo board for real-time software monitoring and safe shutdown response.

Can multiple X-NUCLEO-OUT01A1 boards be stacked or daisy-chained?

No - the board lacks hardware stacking support (no dedicated stackable headers or addressable control). However, it can be used alongside X-NUCLEO-PLC01A1 (8-input board) via shared Arduino connectors to build a 8-in/16-out PLC configuration, and wireless extension is supported via X-NUCLEO-IDW01M1 Wi-Fi module.

X-NUCLEO-OUT01A1 Specifications

Product attributes
Attribute value
Manufacturer:
STMicroelectronics
Series:
-
Packaging:
Bulk
Product Status:
Obsolete
Platform:
Nucleo
Type:
Power Management
Function:
Driver
Utilized IC / Part:
ISO8200BQ
Contents:
Board(s)

X-NUCLEO-OUT01A1 FAQ

1.How can I place an order for X-NUCLEO-OUT01A1 through Aetrix?

Please submit a Request for Quotation (RFQ) for X-NUCLEO-OUT01A1 on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for X-NUCLEO-OUT01A1 reliable?

The price and inventory of X-NUCLEO-OUT01A1 are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for X-NUCLEO-OUT01A1 is usually 5 days.

3.What payment methods are accepted for X-NUCLEO-OUT01A1?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for X-NUCLEO-OUT01A1 transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for X-NUCLEO-OUT01A1?

X-NUCLEO-OUT01A1 orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your X-NUCLEO-OUT01A1 order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for X-NUCLEO-OUT01A1?

For technical support, including X-NUCLEO-OUT01A1 datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your X-NUCLEO-OUT01A1 requirements.

6.How does Aetrix verify that X-NUCLEO-OUT01A1 is sourced from the original manufacturer or authorized distributors?

All X-NUCLEO-OUT01A1 products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that X-NUCLEO-OUT01A1 meets industry standards.

7.What is the process for return or replacement of X-NUCLEO-OUT01A1?

All X-NUCLEO-OUT01A1 units undergo pre-shipment inspection (PSI). If there is an issue with X-NUCLEO-OUT01A1, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The X-NUCLEO-OUT01A1 part is unused and in its original packaging.

Return procedure for X-NUCLEO-OUT01A1:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

X-NUCLEO-OUT01A1 Tags

  • X-NUCLEO-OUT01A1
  • X-NUCLEO-OUT01A1 PDF
  • X-NUCLEO-OUT01A1 Datasheet
  • X-NUCLEO-OUT01A1 Specifications
  • X-NUCLEO-OUT01A1 Images
  • STMicroelectronics
  • STMicroelectronics X-NUCLEO-OUT01A1
  • Buy X-NUCLEO-OUT01A1
  • X-NUCLEO-OUT01A1 Price
  • X-NUCLEO-OUT01A1 Distributor
  • X-NUCLEO-OUT01A1 Supplier
  • X-NUCLEO-OUT01A1 Wholesale
Related Products
2809
2809

Adafruit Industries LLC

BOB-19626
BOB-19626

SparkFun Electronics

DFR0299
DFR0299

DFRobot

5346
5346

Adafruit Industries LLC

4538
4538

Adafruit Industries LLC

4471
4471

Adafruit Industries LLC

1980
1980

Adafruit Industries LLC

4470
4470

Adafruit Industries LLC

U035-B
U035-B

M5Stack Technology Co., Ltd.

SEN0137
SEN0137

DFRobot

3191
3191

Adafruit Industries LLC

4756
4756

Adafruit Industries LLC

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER