Send an Inquiry

To receive a quote for your project, please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Part Number*
Quantity*
Message
Submit Inventory List

Please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Upload My List
Message

STMicroelectronics X-NUCLEO-OUT07A1

Part No.:
X-NUCLEO-OUT07A1
Manufacturer:
STMicroelectronics
Category:
Expansion Boards, Daughter Cards
Package:
Datasheet:
AetrixX-NUCLEO-OUT07A1.pdf
Description:
INDUSTRIAL DIGITAL OUTPUT EXPANS
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:2,727

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

X-NUCLEO-OUT07A1 from STMicroelectronics is an industrial digital output expansion board for STM32 Nucleo development platforms, built around the IPS4260LM quad low-side intelligent power switch. It delivers galvanically isolated 0.5–2 A per channel switching (8–50 V process side), fast rise/fall times (<1 µs), open-load detection, and per-channel overload/thermal protection. It targets PLC I/O module evaluation with Arduino® UNO R3 and ST morpho connectivity.

For engineers reviewing the X-NUCLEO-OUT07A1 datasheet, X-NUCLEO-OUT07A1 pinout, X-NUCLEO-OUT07A1 application, or X-NUCLEO-OUT07A1 equivalent, this board enables rapid validation of isolated digital output architectures-especially where process-side voltage flexibility (10–30 V), configurable current limiting (0.5/1/2 A), and diagnostic signal routing (FLT_L, OL_L, DIAG1–4_L) are critical to industrial control design.

Technical Context

The board implements dual-isolation architecture using STISO620 (logic-to-INx interface) and STISO621 (logic-to-DIAG/FLT/OL interfaces), each rated for 2.8 kVRMS. The isolated DC-DC converter (DC1, 3 kVDC rating) supplies both isolators and the IPS4260LM's logic-side rails (3.3 V or 5 V) and process-side 10 V rail.

IPS4260LM operates in low-side configuration with four independent channels, each featuring programmable current limit via ILIM pin, integrated catch diodes for inductive load decay, and configurable cutoff during overload. Process-side supply is selectable between 10 V (isolated rail) or 10–30 V (external field rail), with reverse-polarity protection on J1 when external supply is used.

Key Specifications

Parameter Value and Actual Design Meaning
Core IC IPS4260LM quad low-side intelligent power switch with integrated diagnostics and protection
Isolation Rating 2.8 kVRMS (STISO620/STISO621) and 3 kVDC (DC1 isolated DC-DC converter)
Process-Side Voltage Range 10 V (isolated rail) or 10–30 V (external field rail); supports typical 24 V industrial loads
Per-Channel Current Limit Selectable: 0.5 A, 1 A, or 2 A via jumper J8 positions 1–2 / 3–4 / 5–6
Switching Speed trise/tfall < 1 µs - enables high-frequency digital output control and fast fault response
Diagnostic Outputs Per-channel DIAG1–4_L, cumulative FLT_L (overload/thermal), and OL_L (open load) signals routed to CN5/CN8/CN9
Logic-Side Supply 3.3 V or 5 V selectable via SW1; powered by NUCLEO board (USB) or external source (CN6 pins 4/5)

Availability

X-NUCLEO-OUT07A1 is available at Aetrix Electronics and suitable for industrial PLC I/O prototyping, STM32-based automation controllers, and ruggedized digital output module qualification requiring stable component supply, traceable sourcing, and long-term lifecycle support.

Supply support for X-NUCLEO-OUT07A1 includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

STMicroelectronics is a global semiconductor leader headquartered in Geneva, Switzerland, designing and manufacturing microcontrollers, power ICs, sensors, and analog/mixed-signal solutions for industrial, automotive, and consumer applications.

X-NUCLEO-OUT07A1 belongs to ST's X-NUCLEO ecosystem of STM32-compatible expansion boards, engineered specifically to accelerate evaluation and integration of intelligent power switches and industrial I/O functions into embedded control systems.

FAQ

Can X-NUCLEO-OUT07A1 operate without being stacked on an STM32 Nucleo board?

Yes - it supports standalone operation. Logic-side supply (3.3 V or 5 V) can be provided externally via CN6 pins 4 or 5 (SW1 closed to 1–2 or 2–3). Process-side supply must be connected to CN1 (V_FIELD_RP and ground) or configured for 10 V rail (SW7 closed to 1–2), with appropriate load connections to CN2/CN3.

What is the function of jumpers J9 and J10?

J9 parallels input control signals (IN1_L–IN4_L) to enable synchronized channel activation; J10 parallels output channels (OUT1–OUT4) to increase current capacity beyond 2 A per channel. Together, they support dual-channel (J9/J10 1–2 & 5–6) or single-channel (J9/J10 all three pairs closed) configurations for higher-power loads.

How does open-load detection work, and how is it enabled?

Open-load detection is implemented per channel inside the IPS4260LM and signaled via OL_L (cumulative) and individual DIAGx_L outputs. It is enabled only when corresponding jumpers J7[1–2], [3–4], [5–6], or [7–8] are closed. When J7 is open, D7 (red LED) and OL_L output are disabled and must be ignored.

Which STM32 Nucleo boards are compatible with X-NUCLEO-OUT07A1?

X-NUCLEO-OUT07A1 is verified for use with NUCLEO-F401RE (STM32F401RE MCU) and NUCLEO-G431RB (STM32G431RB MCU). Both boards provide Arduino® UNO R3 and ST morpho headers, enabling direct stacking and automatic signal mapping for INx_L, DIAGx_L, FLT_L, and OL_L via CN5, CN8, and CN9 connectors.

X-NUCLEO-OUT07A1 Specifications

Product attributes
Attribute value
Manufacturer:
STMicroelectronics
Series:
STM32
Packaging:
Bulk
Product Status:
Active
Platform:
Nucleo
Type:
Power Management
Function:
Power Distribution Switch (Load Switch)
Utilized IC / Part:
IPS4260LM
Contents:
Board(s)

X-NUCLEO-OUT07A1 FAQ

1.How can I place an order for X-NUCLEO-OUT07A1 through Aetrix?

Please submit a Request for Quotation (RFQ) for X-NUCLEO-OUT07A1 on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for X-NUCLEO-OUT07A1 reliable?

The price and inventory of X-NUCLEO-OUT07A1 are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for X-NUCLEO-OUT07A1 is usually 5 days.

3.What payment methods are accepted for X-NUCLEO-OUT07A1?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for X-NUCLEO-OUT07A1 transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for X-NUCLEO-OUT07A1?

X-NUCLEO-OUT07A1 orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your X-NUCLEO-OUT07A1 order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for X-NUCLEO-OUT07A1?

For technical support, including X-NUCLEO-OUT07A1 datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your X-NUCLEO-OUT07A1 requirements.

6.How does Aetrix verify that X-NUCLEO-OUT07A1 is sourced from the original manufacturer or authorized distributors?

All X-NUCLEO-OUT07A1 products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that X-NUCLEO-OUT07A1 meets industry standards.

7.What is the process for return or replacement of X-NUCLEO-OUT07A1?

All X-NUCLEO-OUT07A1 units undergo pre-shipment inspection (PSI). If there is an issue with X-NUCLEO-OUT07A1, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The X-NUCLEO-OUT07A1 part is unused and in its original packaging.

Return procedure for X-NUCLEO-OUT07A1:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

X-NUCLEO-OUT07A1 Tags

  • X-NUCLEO-OUT07A1
  • X-NUCLEO-OUT07A1 PDF
  • X-NUCLEO-OUT07A1 Datasheet
  • X-NUCLEO-OUT07A1 Specifications
  • X-NUCLEO-OUT07A1 Images
  • STMicroelectronics
  • STMicroelectronics X-NUCLEO-OUT07A1
  • Buy X-NUCLEO-OUT07A1
  • X-NUCLEO-OUT07A1 Price
  • X-NUCLEO-OUT07A1 Distributor
  • X-NUCLEO-OUT07A1 Supplier
  • X-NUCLEO-OUT07A1 Wholesale
Related Products
2809
2809

Adafruit Industries LLC

BOB-19626
BOB-19626

SparkFun Electronics

DFR0299
DFR0299

DFRobot

5346
5346

Adafruit Industries LLC

4538
4538

Adafruit Industries LLC

4471
4471

Adafruit Industries LLC

1980
1980

Adafruit Industries LLC

4470
4470

Adafruit Industries LLC

U035-B
U035-B

M5Stack Technology Co., Ltd.

SEN0137
SEN0137

DFRobot

3191
3191

Adafruit Industries LLC

4756
4756

Adafruit Industries LLC

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER