Vishay General Semiconductor - Diodes Division 3.0C100CA-M3/H
- Part No.:
- 3.0C100CA-M3/H
- Manufacturer:
- Vishay General Semiconductor - Diodes Division
- Category:
- TVS Diodes
- Package:
- DO-214AB, SMC
- Datasheet:
-
3.0C100CA-M3/H.pdf
- Description:
- 3KW, 100V 5%,BIDIR,SMC TVS
- Quantity:
- Payment:

- Shipping:

Inventory:6,105
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
3.0C100CA-M3 from Vishay General Semiconductor is a bidirectional surface-mount Transient Voltage Suppressor (TVS) diode in SMC (DO-214AB) package, designed for high-energy surge protection with 3000 W peak pulse power (10/1000 μs), 162 V clamping voltage at 18.5 A, and 100 V stand-off voltage. It protects MOSFETs, ICs, and sensor signal lines in industrial power supplies and telecom interfaces against lightning-induced transients and inductive switching spikes.
For engineers reviewing the 3.0C100CA-M3 datasheet, 3.0C100CA-M3 pinout, 3.0C100CA-M3 application, or 3.0C100CA-M3 equivalent, this page delivers verified electrical parameters, JEDEC-compliant thermal metrics, IEC 61000-4-2 ESD immunity (30 kV contact/air), and precise SMC package mechanical data - all critical for robust overvoltage protection design validation.
Technical Context
This TVS operates as a voltage-clamped shunt device triggered by reverse-biased avalanche breakdown above its 111–123 V breakdown range. Its low incremental surge resistance and sub-nanosecond response time enable effective suppression of fast-rising transients such as 8/20 μs surges (209 V clamping at 144 A) and 10/1000 μs events (162 V at 18.5 A).
Thermal performance is defined by RthJA = 90 °C/W (JEDEC 51-2A, FR4, 2 oz Cu) and RthJM = 4.0 °C/W (JEDEC 51-14 TDIM), supporting reliable operation up to TJ = 175 °C. The -M3 suffix confirms halogen-free, RoHS-compliant construction with JESD 201 Class 2 whisker resistance and MSL Level 1 moisture sensitivity.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| VWM | 100 V - Maximum continuous reverse operating voltage before conduction begins; sets upper limit for circuit bias compatibility. |
| VBR (min/max) | 111 V / 123 V - Breakdown occurs within this range at 1 mA test current; defines turn-on threshold tolerance. |
| VC @ IPPM (10/1000 μs) | 162 V at 18.5 A - Clamped voltage during standard surge event; determines protected circuit's maximum transient exposure. |
| PPPM | 3000 W - Peak pulse power handling per 10/1000 μs waveform; quantifies single-event energy absorption capability. |
| ESD Rating | 30 kV (IEC 61000-4-2, contact & air mode) - Confirms immunity to human-body-model electrostatic discharge without degradation. |
| TJ Range | -55 °C to +175 °C - Full operational junction temperature range; supports deployment in harsh industrial and automotive under-hood environments. |
Pinout & Package
Package: SMC (DO-214AB), surface-mount, bidirectional configuration with unmarked cathode/anode terminals - polarity identification not required for symmetrical operation.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| Anode (Cathode) | Surge current return path | Both terminals function identically in bidirectional mode; connects across protected line and ground or between differential lines. |
| Cathode (Anode) | Surge current conduction path | No functional distinction; terminal symmetry enables flexible PCB layout without orientation constraints. |
Key Features
| Feature | Design Value |
|---|---|
| Bidirectional clamping | Enables symmetric protection on AC lines or ungrounded differential signals without polarity concerns. |
| 30 kW surge rating (8/20 μs) | Supports compliance with IEC 61000-4-5 Level 4 (4 kV line-to-line, 2 kV line-to-ground) surge testing. |
| Low clamping ratio (VC/VWM = 1.62) | Minimizes overvoltage stress on downstream components during transient events. |
| MSL Level 1, 260 °C reflow compatible | Permits standard lead-free SMT assembly without pre-baking or special handling. |
Applications
| Industrial Motor Drives | Telecom Power Interfaces |
|---|---|
Use Scenario: Protection of gate drivers and bus voltage sensing circuits against back-EMF spikes from relay or contactor switching. IC Role / Device Role / Timing Role: Shunt-type transient suppressor placed across DC bus or control signal inputs. Use Value: Limits transient overshoot to ≤162 V, preventing latch-up or oxide rupture in 100 V-rated MOSFETs and op-amps. | Use Scenario: Surge protection on -48 V DC power feeds and RS-485 data lines in central office equipment. IC Role / Device Role / Timing Role: Primary front-end TVS on power input and communication ports. Use Value: Withstands repeated 10/1000 μs surges up to 18.5 A while maintaining <1 μA leakage at 100 V, ensuring low standby loss. |
| Automotive Body Control Modules | Consumer Appliance Sensor Inputs |
Use Scenario: Guarding LIN bus transceivers and microcontroller I/O pins against load dump and ISO 7637-2 pulses. IC Role / Device Role / Timing Role: Secondary-level clamping device after primary LC filtering. Use Value: 175 °C max junction temperature rating allows placement near heat-generating power stages without derating. | Use Scenario: Shielding analog outputs of temperature/humidity sensors from ESD events during handling or cable coupling. IC Role / Device Role / Timing Role: Board-level ESD suppressor on sensor output traces. Use Value: 30 kV HBM ESD rating prevents field failures in unshielded consumer enclosures without added shielding cost. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar transient voltage suppression applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| SMBJ100CA | Lower PPPM (600 W), same VWM (100 V), SMB package (smaller footprint, higher RthJA) | Suitable only for lower-energy transients; not recommended for IEC 61000-4-5 Level 4 compliance. | Select when board space is constrained and surge threat level is limited to IEC 61000-4-2 ESD only. |
| SMCJ100CA | Identical PPPM (3000 W), VWM (100 V), and SMC package; differs in VBR min/max (111–123 V vs. 111–125 V) and VC (162 V vs. 165 V) | Functionally interchangeable in most designs; minor clamping variation requires verification for margin-critical 100 V rail protection. | Preferred for drop-in replacement where Vishay SMCJ series is already qualified in production. |
Compared with SMBJ100CA and SMCJ100CA, the 3.0C100CA-M3 offers identical surge robustness to SMCJ100CA but with tighter VC tolerance and confirmed 30 kV ESD rating - making it optimal for high-reliability industrial systems requiring validated immunity and consistent clamping performance.
Availability
3.0C100CA-M3 is available at Aetrix Electronics and suitable for industrial motor drives, telecom power interfaces, automotive body control modules, and consumer appliance sensor inputs requiring stable component supply and full IEC/EN compliance documentation.
Supply support for 3.0C100CA-M3 includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Vishay General Semiconductor is a global leader in discrete semiconductors, specializing in diodes, rectifiers, MOSFETs, and protection devices with emphasis on reliability, power efficiency, and AEC-Q200 qualification.
The 3.0C100CA-M3 belongs to Vishay's TRANSZORB® SMC family, engineered specifically for high-power transient suppression in space-constrained industrial and telecom infrastructure where consistent clamping, low leakage, and extended thermal endurance are mandatory.
FAQ
What is the clamping voltage of the 3.0C100CA-M3 under a 10/1000 μs surge?
The 3.0C100CA-M3 clamps to a maximum of 162 V at 18.5 A under a 10/1000 μs waveform, as specified in the Vishay datasheet (Document Number 98266). This value ensures protected circuits remain below critical overvoltage thresholds during standardized surge events. The 3.0C100CA-M3 maintains this clamping performance across its full operating temperature range.
Does the 3.0C100CA-M3 meet RoHS and halogen-free requirements?
Yes, the 3.0C100CA-M3 carries the -M3 suffix, which certifies halogen-free, RoHS-compliant construction and industrial-grade reliability per Vishay's material categorization standard. It also passes JESD 201 Class 2 whisker testing and meets UL 94 V-0 flammability requirements for the molding compound.
What is the maximum junction temperature rating for the 3.0C100CA-M3?
The 3.0C100CA-M3 has a maximum junction temperature (TJ) rating of +175 °C, enabling operation in high-ambient environments such as industrial motor controls and automotive under-hood applications. Its thermal resistance values - RthJA = 90 °C/W and RthJM = 4.0 °C/W - support thermal design validation per JEDEC standards.
Is the 3.0C100CA-M3 bidirectional or unidirectional?
The 3.0C100CA-M3 is a bidirectional TVS diode, meaning it provides symmetrical clamping for both positive and negative transients without polarity marking on the SMC (DO-214AB) package. This makes it ideal for AC line protection, differential data lines, and floating signal paths where voltage polarity reversal may occur.
What packaging format is used for the 3.0C100CA-M3/H variant?
The 3.0C100CA-M3/H variant ships in 7-inch diameter plastic tape and reel packaging, with a base quantity of 850 units per reel. This format is optimized for automated SMT placement and complies with industry-standard handling protocols for moisture-sensitive devices (MSL Level 1).
3.0C100CA-M3/H Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Vishay General Semiconductor - Diodes Division
- Package/Case:
- DO-214AB, SMC
- Series:
- TransZorb®
- Packaging:
- Bulk
- Product Status:
- Active
- Type:
- Zener
- Unidirectional Channels:
- -
- Bidirectional Channels:
- 1
- Voltage - Reverse Standoff (Typ):
- 100V
- Voltage - Breakdown (Min):
- 111V
- Voltage - Clamping (Max) @ Ipp:
- 162V
- Current - Peak Pulse (10/1000µs):
- 18.5A
- Power - Peak Pulse:
- 3000W (3kW)
- Power Line Protection:
- No
- Applications:
- Telecom
- Capacitance @ Frequency:
- -
- Operating Temperature:
- -55°C ~ 175°C (TJ)
- Grade:
- Automotive
- Qualification:
- -
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- DO-214AB (SMC)
3.0C100CA-M3/H FAQ
1.How can I place an order for 3.0C100CA-M3/H through Aetrix?
Please submit a Request for Quotation (RFQ) for 3.0C100CA-M3/H on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for 3.0C100CA-M3/H reliable?
The price and inventory of 3.0C100CA-M3/H are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for 3.0C100CA-M3/H is usually 5 days.
3.What payment methods are accepted for 3.0C100CA-M3/H?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for 3.0C100CA-M3/H transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for 3.0C100CA-M3/H?
3.0C100CA-M3/H orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your 3.0C100CA-M3/H order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for 3.0C100CA-M3/H?
For technical support, including 3.0C100CA-M3/H datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your 3.0C100CA-M3/H requirements.
6.How does Aetrix verify that 3.0C100CA-M3/H is sourced from the original manufacturer or authorized distributors?
All 3.0C100CA-M3/H products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that 3.0C100CA-M3/H meets industry standards.
7.What is the process for return or replacement of 3.0C100CA-M3/H?
All 3.0C100CA-M3/H units undergo pre-shipment inspection (PSI). If there is an issue with 3.0C100CA-M3/H, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The 3.0C100CA-M3/H part is unused and in its original packaging.
Return procedure for 3.0C100CA-M3/H:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
3.0C100CA-M3/H Tags

-
ESD9B5.0ST5G
onsemi

-
DESD3V3E1BL-7B
Diodes Incorporated

-
ESD5Z3.3T1G
onsemi

-
D5V0H1B2LP-7B
Diodes Incorporated

-
D5V0P1B2LP-7B
Diodes Incorporated

-
DESD5V0U1BA-7
Diodes Incorporated

-
ESD5Z5.0T1G
onsemi

-
DESD5V0U1BB-7
Diodes Incorporated

-
D12V0L1B2LP-7B
Diodes Incorporated

-
PESD2V0Y1BSFYL
Nexperia USA Inc.

-
DF2S5M4CT,L3F
Toshiba Semiconductor and Storage

-
D5V0L1B2WS-7
Diodes Incorporated
Tech Hub
Comparator circuit design covering voltage thresholds, input limits, open-collector outputs, LM393 wiring, op-amp differences, hysteresis, timing, window detection and practical fault diagnosis.
Schmitt triggers use separate rising and falling thresholds to stabilize slow or noisy signals. This guide covers hysteresis, 74HC14 and 74HCT14 selection, comparator calculations, RC oscillators and p…
Counterfeit components can hide behind convincing markings and passing basic function tests. This engineering reference covers source traceability, external inspection, X-ray, XRF, electrical testing, …
A practical engineering and sourcing framework covering lifecycle verification, lifetime-buy calculations, replacement qualification, supplier checks and counterfeit-risk controls.
TTL and CMOS logic families differ in thresholds, loading, output drive, power and timing. This engineering guide compares 74HC and 74HCT, calculates noise margins and checks 3.3 V/5 V compatibility.
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …