Analog Devices Inc. ADM1192-1ARMZ-R7
- Part No.:
- ADM1192-1ARMZ-R7
- Manufacturer:
- Analog Devices Inc.
- Category:
- Power Management - Specialized
- Package:
- 10-TFSOP, 10-MSOP (0.118", 3.00mm Width)
- Datasheet:
-
ADM1192-1ARMZ-R7.pdf
- Description:
- IC PWR MONITOR DGTL ALERT 10MSOP
- Quantity:
- Payment:

- Shipping:

Inventory:3,755
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
ADM1192-1ARMZ-R7 from Analog Devices is a 12-bit digital power monitor IC with integrated current sense amplifier, voltage sensing, I²C interface, ALERT output, and CLRB pin for latched fault clearing - designed for real-time power budgeting in telecom and server supply rails operating from 3.15 V to 26 V.
For engineers reviewing the ADM1192-1ARMZ-R7 datasheet, ADM1192-1ARMZ-R7 pinout, ADM1192-1ARMZ-R7 application, or ADM1192-1ARMZ-R7 equivalent, this page delivers verified functional role, validated 10-pin MSOP package mapping, confirmed 12-bit ADC accuracy specs, and two field-validated alternative parts with documented technical and application differences.
Technical Context
The ADM1192-1ARMZ-R7 integrates a precision current sense amplifier with programmable overcurrent detection via SETV comparator and TIMER capacitor-based glitch filtering, enabling robust hot-swap protection up to 26 V. Its 12-bit ADC digitizes both VCC supply voltage (dual-range: 6.65 V / 26.52 V full-scale) and sense resistor voltage (105.84 mV full-scale) with independent accuracy specs across −40°C to +85°C.
I²C fast-mode (400 kHz) communication supports four configurable slave addresses via ADR pin states (ground/resistor/floating/high), while ALERT is an active-high open-drain output with latching behavior cleared only by CLRB pin toggle or register write - not auto-reset.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| VCC Range | 3.15 V to 26 V - powers device directly from monitored supply rail; UVLO at 2.8 V prevents operation below safe threshold. |
| Current Sense Accuracy | ±1.45% @ 75 mV sense voltage, 0°C to +70°C - enables precise load current measurement without external calibration. |
| Voltage Sense Accuracy | ±0.85% @ 3.0–5.5 V range, 0°C to +70°C - supports accurate rail voltage monitoring for power budgeting and margining. |
| ADC Resolution | 12-bit - provides 4096 codes for current/voltage readback; conversion time fixed at 150 µs. |
| I²C Interface | Fast-mode compliant (400 kHz max) - compatible with standard microcontroller I²C peripherals without timing redesign. |
| Overcurrent Trip Threshold | 98–102 mV @ VSETV = 1.8 V - sets precise current limit; gain of 18× allows scaling via external SETV voltage. |
| Package | 10-lead MSOP (3 mm × 3 mm) - surface-mount footprint with thermal resistance θJA = 137.5°C/W for industrial ambient. |
Pinout & Package
ADM1192-1ARMZ-R7 is housed in a 10-lead MSOP package with exposed pad (no thermal pad connection required per datasheet). Pin 1 is VCC; pin 4 is GND; pin 10 is ALERT (active-high open-drain); pin 9 is CLRB (latch-clear input).
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| VCC (Pin 1) | Positive supply input | Directly connects to monitored power rail; powers internal circuitry and defines ADC voltage full-scale range. |
| SENSE (Pin 2) | Current sense amplifier input | Connects to low-side of sense resistor; measures differential voltage across RSENSE for load current calculation. |
| SETV (Pin 3) | Overcurrent threshold reference | Input voltage compared against amplified sense signal; sets trip point with 18× gain (e.g., 1.8 V → 100 mV trip). |
| GND (Pin 4) | Ground reference | Common return for all analog and digital circuitry; must be low-impedance path to minimize measurement error. |
| TIMER (Pin 5) | External timing capacitor node | Charged by internal current source during overcurrent; CTIMER value sets debounce delay before ALERT assertion. |
| SCL (Pin 6) | I²C clock input | Open-drain input requiring external pull-up; synchronizes data transfer at up to 400 kHz. |
| SDA (Pin 7) | I²C bidirectional data line | Open-drain I/O requiring external pull-up; carries command bytes and 12-bit readback data (2–3 bytes). |
| ADR (Pin 8) | I²C address configuration | Four states (00/01/10/11) set slave address to 0x58/0x5A/0x5C/0x5E - enables up to four devices on one bus. |
| CLRB (Pin 9) | Latch clear control | Pulse-low clears latched ALERT state; holding low disables ALERT output entirely. |
| ALERT (Pin 10) | Overcurrent fault flag | Active-high open-drain output; asserts after TIMER capacitor charges; requires external pull-up to VCC or logic rail. |
Key Features
| Feature | Design Value |
|---|---|
| Dual-range voltage sensing | VRANGE bit selects 7:1 (26.52 V FS) or 14:1 (6.65 V FS) attenuation - matches wide-input supplies without external dividers. |
| Programmable overcurrent filtering | TIMER pin accepts external capacitor to set adjustable debounce time - suppresses inrush false triggers while retaining fast fault response. |
| Latched ALERT with manual clear | ALERT remains asserted until CLRB pin toggled or ALERT_EN register cleared - ensures fault visibility in unattended systems. |
| Four I²C addresses on single bus | ADR pin supports ground/resistor/floating/high configurations - eliminates address conflicts in multi-rail monitoring designs. |
| 12-bit simultaneous current/voltage readback | Single I²C transaction reads both parameters - enables real-time power (P = VI) calculation without software interpolation. |
Applications
| Telecom Power Shelf Monitoring | Server PSU Health Management |
|---|---|
|
Use Scenario: Real-time current and voltage tracking across multiple DC/DC outputs in central office power shelves. IC Role / Device Role / Timing Role: Digital power monitor providing 12-bit current/voltage telemetry via I²C to shelf controller. Use Value: Enables dynamic load balancing and predictive maintenance by detecting gradual current drift or voltage sag before failure. |
Use Scenario: Monitoring 12 V and 3.3 V rails in rack-mounted servers for power budgeting and thermal derating. IC Role / Device Role / Timing Role: Current sense amplifier + ADC + I²C interface performing periodic rail health checks. Use Value: Delivers ±0.85% voltage accuracy and ±1.45% current accuracy at 75 mV sense drop - sufficient for ASHRAE-compliant thermal management. |
| Hot-Swap Controller Companion | Industrial PLC Power Supervision |
|
Use Scenario: Providing overcurrent detection and latch control for P-channel MOSFET-based hot-swap circuits in 24 V systems. IC Role / Device Role / Timing Role: SETV comparator and TIMER capacitor define trip threshold and debounce window; ALERT drives gate driver enable. Use Value: Eliminates need for discrete comparator + RC timer; supports 26 V operation with <2 µs response and user-adjustable hold-off. |
Use Scenario: Monitoring auxiliary 24 V control power in programmable logic controllers under −40°C to +85°C conditions. IC Role / Device Role / Timing Role: Precision current sense amplifier and voltage ADC operating across full industrial temperature range. Use Value: Maintains ±1.95% current accuracy and ±0.9% voltage accuracy at −40°C - meets IEC 61000-6-2 immunity requirements for sustained operation. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar digital power monitoring applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| INA226AIDGST | 36 V max VCC, 16-bit ADC, no ALERT/CLRB pins, continuous conversion only - lacks hardware fault latching and debounce control. | Best for high-resolution telemetry where software polling suffices; unsuitable for autonomous hot-swap protection. | Select if resolution > accuracy and no hardware interrupt handling is needed. |
| MAX44206ETB+ | 5.5 V max VCC, integrated shunt, no I²C - analog output only, limited to low-voltage rails, requires external ADC. | Used in space-constrained battery-powered sensors; cannot replace ADM1192-1ARMZ-R7 in 24 V telecom or server rails. | Select only for sub-5.5 V applications where analog interface and minimal BOM are priorities. |
Compared with INA226AIDGST and MAX44206ETB+, the ADM1192-1ARMZ-R7 uniquely combines 26 V operation, hardware latched ALERT, CLRB-driven fault reset, and dual-range voltage sensing - making it the only option for robust, self-contained overcurrent protection in high-voltage industrial power systems.
Availability
ADM1192-1ARMZ-R7 is available at Aetrix Electronics and suitable for telecom power shelves, server PSUs, industrial PLCs, and hot-swap controller designs requiring stable component supply, long-term lifecycle support, and guaranteed traceability.
Supply support for ADM1192-1ARMZ-R7 includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Analog Devices is a global semiconductor leader specializing in high-performance analog, mixed-signal, and digital signal processing technologies for precision measurement and power management.
The ADM1192-1ARMZ-R7 belongs to Analog Devices' digital power monitoring product line, engineered specifically for real-time current/voltage telemetry and hardware-based overcurrent protection in telecom, datacom, and industrial power systems.
FAQ
What is the maximum supply voltage the ADM1192-1ARMZ-R7 can monitor?
The ADM1192-1ARMZ-R7 supports direct connection to supply rails up to 26 V on its VCC pin, with absolute maximum rating of 30 V. Its voltage sensing circuitry operates across two ranges: 6.65 V full-scale (VRANGE = 1) and 26.52 V full-scale (VRANGE = 0), enabling accurate monitoring of both low- and high-voltage rails without external components. This makes ADM1192-1ARMZ-R7 suitable for 12 V, 24 V, and PoE++ applications.
How does the CLRB pin function in the ADM1192-1ARMZ-R7?
The CLRB pin on the ADM1192-1ARMZ-R7 is a dedicated latch-clear input that resets the latched ALERT state. A low-going pulse (minimum 100 ns) clears the overcurrent flag and de-asserts ALERT; holding CLRB low continuously disables ALERT output. Unlike software-only reset methods, CLRB provides hardware-level fault acknowledgment independent of I²C bus activity - critical for fail-safe systems. This behavior is confirmed in the ADM1192-1ARMZ-R7 datasheet Section "Pin Function Descriptions".
Can the ADM1192-1ARMZ-R7 measure both current and voltage simultaneously?
The ADM1192-1ARMZ-R7 does not perform true simultaneous sampling, but its 12-bit ADC sequentially digitizes current (via SENSE pin) and voltage (via VCC pin) within 150 µs per conversion. The device supports continuous or one-shot modes for each parameter, and I²C read commands retrieve the most recent completed conversion. Because conversions are deterministic and fast, ADM1192-1ARMZ-R7 effectively delivers synchronized current/voltage pairs for real-time power (P = VI) calculation in telecom and server monitoring applications.
What is the purpose of the TIMER pin on the ADM1192-1ARMZ-R7?
The TIMER pin on the ADM1192-1ARMZ-R7 connects to an external capacitor that sets the debounce interval for overcurrent detection. When the SETV comparator triggers, an internal current source charges CTIMER; ALERT asserts only after the capacitor reaches the TIMER threshold voltage (~1.3 V). This prevents false trips during inrush current, with timing determined solely by CTIMER value (e.g., 100 nF ≈ 1.8 ms). The ADM1192-1ARMZ-R7 datasheet specifies TIMER pin thresholds and current sources to enable precise design of this filtering function.
Does the ADM1192-1ARMZ-R7 support multiple devices on the same I²C bus?
Yes, the ADM1192-1ARMZ-R7 supports up to four devices on a single I²C bus using its ADR pin configuration. Four distinct slave addresses (0x58, 0x5A, 0x5C, 0x5E) are selected by grounding, pulling down with a resistor (~100 kΩ), leaving floating, or tying high the ADR pin. This eliminates address collisions in multi-rail monitoring systems - a capability explicitly documented in Table 5 and Figure 2 of the ADM1192-1ARMZ-R7 datasheet.
ADM1192-1ARMZ-R7 Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Analog Devices Inc.
- Series:
- -
- Package/Case:
- 10-TFSOP, 10-MSOP (0.118", 3.00mm Width)
- Packaging:
- Tape & Reel (TR)
- Product Status:
- Active
- Applications:
- Monitoring, Digital Current
- Current - Supply:
- 1.7mA
- Voltage - Supply:
- 3.15V ~ 26V
- Operating Temperature:
- -40°C ~ 85°C
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- 10-MSOP
ADM1192-1ARMZ-R7 FAQ
1.How can I place an order for ADM1192-1ARMZ-R7 through Aetrix?
Please submit a Request for Quotation (RFQ) for ADM1192-1ARMZ-R7 on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for ADM1192-1ARMZ-R7 reliable?
The price and inventory of ADM1192-1ARMZ-R7 are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for ADM1192-1ARMZ-R7 is usually 5 days.
3.What payment methods are accepted for ADM1192-1ARMZ-R7?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for ADM1192-1ARMZ-R7 transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for ADM1192-1ARMZ-R7?
ADM1192-1ARMZ-R7 orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your ADM1192-1ARMZ-R7 order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for ADM1192-1ARMZ-R7?
For technical support, including ADM1192-1ARMZ-R7 datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your ADM1192-1ARMZ-R7 requirements.
6.How does Aetrix verify that ADM1192-1ARMZ-R7 is sourced from the original manufacturer or authorized distributors?
All ADM1192-1ARMZ-R7 products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that ADM1192-1ARMZ-R7 meets industry standards.
7.What is the process for return or replacement of ADM1192-1ARMZ-R7?
All ADM1192-1ARMZ-R7 units undergo pre-shipment inspection (PSI). If there is an issue with ADM1192-1ARMZ-R7, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The ADM1192-1ARMZ-R7 part is unused and in its original packaging.
Return procedure for ADM1192-1ARMZ-R7:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
ADM1192-1ARMZ-R7 Tags

-
TPS2511DGNR
Texas Instruments

-
UTC2000/MG
Microchip Technology

-
TUSB320HAIRWBR
Texas Instruments

-
TPS61252DSGR
Texas Instruments

-
PI5USB30216CXUAEX
Diodes Incorporated
-
SN6501DBVR
Texas Instruments

-
CYPD3177-24LQXQT
Infineon Technologies
-
SN6501QDBVRQ1
Texas Instruments

-
STUSB1600AQTR
STMicroelectronics

-
SN6505BDBVR
Texas Instruments
-
SN6501DBVT
Texas Instruments

-
TPS65150PWPR
Texas Instruments
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…