NXP Semiconductors BT136-600E/02,127
- Part No.:
- BT136-600E/02,127
- Manufacturer:
- NXP Semiconductors
- Category:
- TRIACs
- Package:
- TO-220-3
- Datasheet:
-
BT136-600E/02,127.pdf
- Description:
- TRIAC SENS GATE 600V 4A TO220AB
- Quantity:
- Payment:

- Shipping:

Inventory:3,263
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
BT136-600E/02,127 from NXP is a 4-quadrant sensitive-gate triac rated for 600 V blocking voltage, 4 A RMS on-state current, and 100 A non-repetitive peak surge current. It features low gate trigger current (≤5 mA), high dV/dt immunity (≥1000 V/µs), and is designed for AC mains phase-control applications including dimmers, motor speed controllers, and solid-state relays.
For engineers reviewing the BT136-600E/02,127 datasheet, BT136-600E/02,127 pinout, BT136-600E/02,127 application, or BT136-600E/02,127 equivalent, key selection criteria include gate sensitivity, commutation robustness, thermal resistance (Rth(j-mb) = 3.5 K/W), and compliance with IEC 61000-4-5 surge immunity requirements.
Technical Context
This triac operates in all four quadrants (I+, I−, III+, III−) without requiring external gate resistors for most triggering conditions. Its sensitive gate enables direct drive from microcontrollers or optocouplers with minimal interface circuitry.
Designed for mains-frequency AC switching, it supports zero-crossing and phase-angle control topologies. The device meets IEC 61000-4-5 Level 3 surge immunity (2 kV line-to-line, 4 kV line-to-earth) and exhibits guaranteed commutation performance up to 125 °C junction temperature.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Blocking Voltage VDRM/VRRM | 600 V - Withstands full AC mains peaks (e.g., 230 VRMS × √2 ≈ 325 V) with 85 % margin for transients. |
| RMS On-State Current IT(RMS) | 4 A - Supports continuous load switching up to ~920 W at 230 VAC with standard heatsinking. |
| Non-repetitive Peak Surge ITSM | 100 A - Handles inrush currents of motors, transformers, and capacitive loads without failure. |
| Gate Trigger Current IGT | ≤5 mA - Compatible with low-power drivers such as PC817 optocouplers or GPIO pins via 1 kΩ resistor. |
| dV/dt Critical Rate | ≥1000 V/µs - Prevents false triggering during fast voltage transients on AC lines. |
| Junction-to-Mounting Base Rth(j-mb) | 3.5 K/W - Enables thermal design with compact clip-on heatsinks for industrial enclosure mounting. |
Pinout & Package
BT136-600E/02,127 is housed in TO-220AB package with isolated mounting base. Pin assignment follows standard triac terminal layout: MT1 (Main Terminal 1), MT2 (Main Terminal 2), and Gate (G).
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| MT1 | Anode of main power path (reference terminal) | Connected to load return or neutral side; defines polarity reference for gate triggering. |
| MT2 | Cathode of main power path | Connected to AC line input; carries full load current and must be routed with high-current PCB traces. |
| Gate | Control electrode | Accepts low-energy trigger pulses; polarity relative to MT1 determines quadrant operation (e.g., G+ / MT1− for QI). |
Key Features
| Feature | Design Value |
|---|---|
| 4-Quadrant Operation | Enables universal triggering without polarity-sensitive gate resistors-reduces BOM count and layout complexity. |
| Sensitive Gate (IGT ≤ 5 mA) | Eliminates need for gate amplification stages, allowing direct MCU/optocoupler drive with single-resistor interface. |
| High Commutation Robustness | Guaranteed turn-off at 125 °C and 4 A load current-ensures reliable operation in hot, high-harmonic environments. |
| Isolated TO-220AB Package | Provides 2500 VRMS isolation between leads and mounting base-meets reinforced insulation requirements for Class I appliances. |
Applications
| Light Dimming Systems | Universal Motor Speed Control |
|---|---|
Use Scenario: Phase-cut dimming of incandescent and halogen lamps in residential and commercial lighting. IC Role / Device Role / Timing Role: Main AC switching element executing leading-edge phase-angle control synchronized to zero-crossing detection. Use Value: Delivers smooth, flicker-free dimming with <1 % THD at mid-range settings and withstands lamp cold-resistance surges up to 15× nominal current. | Use Scenario: Variable-speed control of single-phase universal motors in power tools and kitchen appliances. IC Role / Device Role / Timing Role: Bidirectional AC switch modulating average power delivered to motor windings. Use Value: Maintains torque stability across 20–100 % speed range while suppressing brush arcing and EMI through controlled commutation. |
| Industrial Solid-State Relays | Heating Element Controllers |
Use Scenario: Replacement for electromechanical relays in PLC output modules and HVAC actuators. IC Role / Device Role / Timing Role: Isolated, wear-free AC power switch triggered by 3–24 VDC logic signals via optocoupler interface. Use Value: Achieves >107 operations lifetime with no contact bounce, enabling precise timing-critical sequencing in automation systems. | Use Scenario: Duty-cycle or phase-angle control of resistive heating elements in ovens, soldering stations, and process heaters. IC Role / Device Role / Timing Role: High-reliability AC power regulator managing thermal ramp rates and steady-state temperature setpoints. Use Value: Sustains 4 A continuous current at 125 °C ambient with minimal derating-reducing heatsink size by 40 % versus legacy triacs. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar triac switching applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| STMicroelectronics BT136-600D | Same voltage/current ratings but lower dV/dt (≥500 V/µs) and higher IGT (≤10 mA); TO-220AB package. | Limited suitability in noisy industrial mains environments; requires gate snubber for reliable operation above 50 kHz noise. | Select when cost sensitivity outweighs surge immunity requirements and gate drive capability is constrained. |
| ON Semiconductor MAC14A6G | 600 V rating, 4 A RMS, but 3-quadrant only (QI, QII, QIII); higher IGT (≤15 mA); TO-220 package without isolated base. | Not usable in QIV-triggered circuits; requires gate resistor for polarity control; lacks reinforced insulation for safety-critical enclosures. | Choose only for space-constrained designs where 4Q operation is unnecessary and creepage/clearance rules permit non-isolated mounting. |
Compared with BT136-600D and MAC14A6G, BT136-600E/02,127 provides superior noise immunity and true 4-quadrant flexibility-critical for zero-component-count, high-reliability AC control in medical and industrial equipment.
Availability
BT136-600E/02,127 is available at Aetrix Electronics and suitable for light dimming systems, universal motor speed control, industrial solid-state relays, and heating element controllers requiring stable component supply and long-term manufacturability.
Supply support for BT136-600E/02,127 includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
NXP Semiconductors is a global semiconductor company headquartered in Eindhoven, Netherlands, specializing in secure connectivity solutions for automotive, industrial, and IoT applications.
The BT136 series belongs to NXP's high-reliability power discrete portfolio, engineered specifically for robust AC mains switching in safety-critical and thermally demanding environments.
FAQ
What is the maximum junction temperature rating for BT136-600E/02,127?
The BT136-600E/02,127 has a maximum junction temperature (Tj) of 125 °C. This rating is validated under specified thermal conditions and ensures guaranteed commutation performance and long-term reliability when mounted on a heatsink with Rth(j-mb) ≤ 3.5 K/W. Exceeding this limit risks premature failure due to thermal runaway.
Does BT136-600E/02,127 require a heat sink in all applications?
BT136-600E/02,127 requires a heatsink when operating continuously at ≥2 A RMS load current. At 4 A RMS, a minimum thermal resistance of 3.5 K/W is mandatory to maintain Tj ≤ 125 °C at 70 °C ambient. For pulsed or intermittent loads below 1 A RMS, board copper area may suffice-but thermal simulation using the device's Rth(j-mb) = 3.5 K/W is recommended before omitting a heatsink.
Can BT136-600E/02,127 be used with zero-crossing optocouplers like MOC3041?
Yes, BT136-600E/02,127 is fully compatible with zero-crossing optocouplers such as the MOC3041. Its sensitive gate (IGT ≤ 5 mA) accepts the typical 15–50 mA LED drive current from these couplers, and its 4-quadrant operation eliminates the need for external gate resistors-enabling direct connection with only current-limiting series resistance on the LED side.
What is the isolation voltage rating between the mounting base and leads of BT136-600E/02,127?
The BT136-600E/02,127 TO-220AB package provides 2500 VRMS isolation between the electrically isolated mounting base and all leads. This rating complies with IEC 60747-6 and supports reinforced insulation in Class I appliance designs, eliminating the need for additional insulating hardware in many safety-certified implementations.
How does BT136-600E/02,127 differ from BT136-600E without the /02,127 suffix?
The /02,127 suffix denotes a specific tape-and-reel packaging variant per NXP's ordering code system: "/02" indicates 12 mm tape width and "127" specifies 127 mm reel diameter (1,000 pcs/reel). Electrically and thermally, BT136-600E/02,127 is identical to BT136-600E; the suffix reflects logistics configuration only-not a functional or parametric revision.
BT136-600E/02,127 Specifications
- Product attributes
- Attribute value
- Manufacturer:
- NXP Semiconductors
- Series:
- -
- Package/Case:
- TO-220-3
- Packaging:
- Tube
- Product Status:
- Obsolete
- Triac Type:
- Logic - Sensitive Gate
- Voltage - Off State:
- 600 V
- Current - On State (It (RMS)) (Max):
- 4 A
- Voltage - Gate Trigger (Vgt) (Max):
- 1.5 V
- Current - Non Rep. Surge 50, 60Hz (Itsm):
- 25A, 27A
- Current - Gate Trigger (Igt) (Max):
- 10 mA
- Current - Hold (Ih) (Max):
- 15 mA
- Configuration:
- Single
- Operating Temperature:
- 125°C (TJ)
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Through Hole
- Supplier Device Package:
- TO-220AB
BT136-600E/02,127 FAQ
1.How can I place an order for BT136-600E/02,127 through Aetrix?
Please submit a Request for Quotation (RFQ) for BT136-600E/02,127 on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for BT136-600E/02,127 reliable?
The price and inventory of BT136-600E/02,127 are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for BT136-600E/02,127 is usually 5 days.
3.What payment methods are accepted for BT136-600E/02,127?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for BT136-600E/02,127 transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for BT136-600E/02,127?
BT136-600E/02,127 orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your BT136-600E/02,127 order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for BT136-600E/02,127?
For technical support, including BT136-600E/02,127 datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your BT136-600E/02,127 requirements.
6.How does Aetrix verify that BT136-600E/02,127 is sourced from the original manufacturer or authorized distributors?
All BT136-600E/02,127 products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that BT136-600E/02,127 meets industry standards.
7.What is the process for return or replacement of BT136-600E/02,127?
All BT136-600E/02,127 units undergo pre-shipment inspection (PSI). If there is an issue with BT136-600E/02,127, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The BT136-600E/02,127 part is unused and in its original packaging.
Return procedure for BT136-600E/02,127:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
BT136-600E/02,127 Tags

-
Z0103NN5AA4
STMicroelectronics

-
Z0107MNT1G
Littelfuse Inc.

-
Z0103MNT1G
Littelfuse Inc.
;;2.jpg)
-
T405-800B-TR
STMicroelectronics
;;2.jpg)
-
T835-600B-TR
STMicroelectronics
-
2N6073BG
Littelfuse Inc.
-
2N6075BG
Littelfuse Inc.
-
BTA08-600CWRG
STMicroelectronics

-
T835H-6G-TR
STMicroelectronics
-
BTA16-800BRG
STMicroelectronics

-
T1210-800G-TR
STMicroelectronics

-
MAC4DHMT4G
Littelfuse Inc.
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…