Product details
Overview
BTA06-600CRG from STMicroelectronics is a 6 A, 600 V RMS snubberless triac in insulated TO-220AB package, designed for AC phase control and ON/OFF switching in inductive loads. It features 25 mA gate trigger current (QI–QIII), 1.3 V max gate trigger voltage, and 2500 VRMS voltage-isolated tab compliant with UL E81734. Used in motor speed controllers and heating regulation circuits.
For engineers reviewing the BTA06-600CRG datasheet, BTA06-600CRG pinout, BTA06-600CRG application, or BTA06-600CRG equivalent, key selection criteria include commutation robustness on inductive loads, insulated tab safety rating, gate sensitivity class (C = 25 mA), and snubberless operation at 125°C junction temperature.
Technical Context
The BTA06-600CRG is a three-quadrant snubberless triac optimized for reliable commutation on inductive loads without external snubbers. Its design incorporates an internal ceramic pad enabling 2500 VRMS isolation between MT2 and tab, meeting UL insulation requirements.
It operates across quadrants I, II, and III with guaranteed 25 mA max IGT (QI–QIII), 10 mA max holding current (IH), and 400 V/µs minimum dV/dt immunity at 125°C - critical for noise-immune triggering in motor drive and dimmer applications.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| IT(RMS) | 6 A - continuous AC load current handling capability at Tc = 105°C |
| VDRM / VRRM | 600 V - peak repetitive off-state blocking voltage in both directions |
| IGT (QI–QIII) | 25 mA max - low gate drive requirement compatible with microcontroller GPIO |
| dV/dt (min) | 400 V/µs at 125°C - high noise immunity prevents false triggering in noisy industrial environments |
| Rth(j-c) | 2.7 °C/W - thermal resistance from junction to insulated case, enabling 6 A operation with modest heatsinking |
| VTM (max) | 1.55 V at 8.5 A - low conduction loss reduces power dissipation and heatsink size |
| Isolation Rating | 2500 VRMS - reinforced insulation between MT2 and tab per UL E81734 |
Pinout & Package
Package: TO-220AB Insulated - thermally conductive but electrically isolated metal tab rated for 2500 VRMS; mounting screw must not short tab to heatsink ground.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| A1 (MT1) | Main Terminal 1 | AC line or load return path; referenced as common for gate trigger circuit |
| A2 (MT2) | Main Terminal 2 | AC line or load hot connection; electrically isolated from tab |
| G | Gate | Trigger input; requires ≥25 mA pulse to initiate conduction in QI/QII/QIII |
Key Features
| Feature | Design Value |
|---|---|
| Snubberless operation | Eliminates need for RC snubber network on inductive loads, reducing BOM count and board space |
| UL-certified insulated tab | 2500 VRMS isolation enables safe mounting to grounded heatsinks in Class I appliances |
| Three-quadrant triggering | Supports gate triggering only in QI, QII, QIII - improves noise immunity vs. 4Q standard triacs |
| High commutation robustness | (dV/dt)c ≥ 400 V/µs at 125°C ensures reliable turn-off under fast voltage transients |
Applications
| Motor Speed Control | Heating Regulation |
|---|---|
Use Scenario: Variable-speed control of single-phase induction motors in fans, pumps, and compressors. IC Role / Device Role / Timing Role: Main AC power switch modulating RMS voltage via phase-angle control. Use Value: Snubberless operation prevents false turn-on during motor back-EMF spikes; 400 V/µs dV/dt immunity sustains stable commutation. | Use Scenario: Precise temperature maintenance in resistive heating elements of ovens, water heaters, and soldering stations. IC Role / Device Role / Timing Role: Zero-crossing or phase-controlled ON/OFF switch regulating average power delivery. Use Value: 6 A IT(RMS) supports up to ~1.3 kW at 230 VAC; insulated tab simplifies safety-compliant enclosure design. |
| Light Dimming | Static Relay Replacement |
Use Scenario: Leading-edge dimming of incandescent and halogen lamps in residential and commercial lighting. IC Role / Device Role / Timing Role: Bidirectional AC switch triggered synchronously with AC zero-crossing for smooth brightness adjustment. Use Value: 25 mA IGT allows direct drive from MCU GPIO; 1.55 V VTM minimizes conduction loss and self-heating. | Use Scenario: Solid-state replacement of electromechanical relays in PLC output modules and HVAC control panels. IC Role / Device Role / Timing Role: Fail-safe AC load switch with galvanic isolation and surge tolerance. Use Value: 60 A non-repetitive surge rating (50 Hz, 20 ms) handles inrush currents of solenoids and transformers. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar triac switching applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| BTA06-600BW | 50 mA IGT (vs. 25 mA); same 600 V, snubberless, insulated TO-220AB | Higher gate drive requirement; less suitable for low-power MCU outputs | Select when gate driver has ≥50 mA sourcing capability and cost optimization is prioritized |
| BTB06-600CRG | Non-insulated TO-220AB package; identical electrical specs except tab isolation | Requires insulated mounting hardware; unsuitable for UL Class I designs requiring reinforced isolation | Select only where heatsink is floating or system-level isolation is implemented elsewhere |
Compared with BTA06-600BW and BTB06-600CRG, the BTA06-600CRG uniquely balances low gate drive (25 mA), snubberless reliability on inductors, and certified 2500 VRMS tab isolation - making it optimal for safety-critical, space-constrained, and microcontroller-driven AC control systems.
Availability
BTA06-600CRG is available at Aetrix Electronics and suitable for motor speed controllers, heating regulation systems, light dimmers, and static relay replacements requiring stable component supply and long-term industrial availability.
Supply support for BTA06-600CRG includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
STMicroelectronics is a global semiconductor leader headquartered in Geneva, Switzerland, specializing in power management, analog, MEMS, and microcontrollers for industrial, automotive, and consumer markets.
The BTA/BTB06 series belongs to ST's high-reliability AC power switching portfolio, engineered specifically for robust phase-control and ON/OFF switching in inductive and resistive AC loads under harsh thermal and electrical conditions.
FAQ
What is the maximum junction temperature for continuous operation?
The BTA06-600CRG has a maximum operating junction temperature of +125°C. At this temperature, its RMS on-state current rating drops to 6 A only when case temperature is maintained at ≤105°C using appropriate heatsinking - verified by Rth(j-c) = 2.7 °C/W and derating curves in Figure 2 of the datasheet.
Can this triac be driven directly from a 3.3 V microcontroller GPIO?
Yes - with proper current limiting. The BTA06-600CRG requires ≤25 mA gate trigger current and ≤1.3 V gate trigger voltage. A 3.3 V GPIO can drive it via a 100 Ω series resistor (delivering ~30 mA peak), provided the MCU pin supports ≥30 mA sink/source and the pulse width exceeds 10 µs per the datasheet's gate trigger timing requirements.
Does the insulated tab require thermal compound when mounted to a heatsink?
Yes - thermal interface material (TIM) is required. Although the tab is electrically insulated, its thermal path relies on physical contact with the heatsink. ST specifies that the 2.7 °C/W Rth(j-c) assumes use of standard thermal grease or pad; omitting TIM increases thermal resistance significantly and risks thermal runaway at full 6 A load.
How does "snubberless" operation improve reliability in motor control?
Snubberless operation means the triac maintains reliable commutation during rapid voltage transients (e.g., motor back-EMF) without external RC networks. The BTA06-600CRG achieves this via enhanced dV/dt immunity (400 V/µs at 125°C) and optimized internal structure - eliminating snubber component failure points and reducing PCB area and cost in motor starter circuits.
BTA06-600CRG Specifications
- Product attributes
- Attribute value
- Manufacturer:
- STMicroelectronics
- Series:
- -
- Package/Case:
- TO-220-3
- Packaging:
- Tube
- Product Status:
- Active
- Triac Type:
- Standard
- Voltage - Off State:
- 600 V
- Current - On State (It (RMS)) (Max):
- 6 A
- Voltage - Gate Trigger (Vgt) (Max):
- 1.3 V
- Current - Non Rep. Surge 50, 60Hz (Itsm):
- 60A, 63A
- Current - Gate Trigger (Igt) (Max):
- 25 mA
- Current - Hold (Ih) (Max):
- 25 mA
- Configuration:
- Single
- Operating Temperature:
- -40°C ~ 125°C (TJ)
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Through Hole
- Supplier Device Package:
- TO-220
BTA06-600CRG FAQ
1.How can I place an order for BTA06-600CRG through Aetrix?
Please submit a Request for Quotation (RFQ) for BTA06-600CRG on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for BTA06-600CRG reliable?
The price and inventory of BTA06-600CRG are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for BTA06-600CRG is usually 5 days.
3.What payment methods are accepted for BTA06-600CRG?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for BTA06-600CRG transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for BTA06-600CRG?
BTA06-600CRG orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your BTA06-600CRG order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for BTA06-600CRG?
For technical support, including BTA06-600CRG datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your BTA06-600CRG requirements.
6.How does Aetrix verify that BTA06-600CRG is sourced from the original manufacturer or authorized distributors?
All BTA06-600CRG products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that BTA06-600CRG meets industry standards.
7.What is the process for return or replacement of BTA06-600CRG?
All BTA06-600CRG units undergo pre-shipment inspection (PSI). If there is an issue with BTA06-600CRG, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The BTA06-600CRG part is unused and in its original packaging.
Return procedure for BTA06-600CRG:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
BTA06-600CRG Tags

-
Z0103NN5AA4
STMicroelectronics

-
Z0107MNT1G
Littelfuse Inc.

-
Z0103MNT1G
Littelfuse Inc.
;;2.jpg)
-
T405-800B-TR
STMicroelectronics
;;2.jpg)
-
T835-600B-TR
STMicroelectronics
-
2N6073BG
Littelfuse Inc.
-
2N6075BG
Littelfuse Inc.
-
BTA08-600CWRG
STMicroelectronics

-
T835H-6G-TR
STMicroelectronics
-
BTA16-800BRG
STMicroelectronics

-
T1210-800G-TR
STMicroelectronics

-
MAC4DHMT4G
Littelfuse Inc.
Tech Hub
Counterfeit components can hide behind convincing markings and passing basic function tests. This engineering reference covers source traceability, external inspection, X-ray, XRF, electrical testing, …
A practical engineering and sourcing framework covering lifecycle verification, lifetime-buy calculations, replacement qualification, supplier checks and counterfeit-risk controls.
TTL and CMOS logic families differ in thresholds, loading, output drive, power and timing. This engineering guide compares 74HC and 74HCT, calculates noise margins and checks 3.3 V/5 V compatibility.
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…