STMicroelectronics BTA06-600SRG
- Part No.:
- BTA06-600SRG
- Manufacturer:
- STMicroelectronics
- Category:
- TRIACs
- Package:
- TO-220-3 Full Pack
- Datasheet:
-
BTA06-600SRG.pdf
- Description:
- TRIAC SENS GATE 600V 6A TO220AB
- Quantity:
- Payment:

- Shipping:

Inventory:126
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
BTA06-600SRG from STMicroelectronics is a 6 A, 600 V RMS snubberless logic-level triac in insulated TO-220AB package, rated for 2500 VRMS voltage isolation between tab and terminals. It supports phase control and ON/OFF switching in AC loads, with 5 mA gate trigger current (Q1), 1.3 V gate trigger voltage, and 50 A non-repetitive surge rating-used in lighting dimmers and motor speed controllers.
For engineers reviewing the BTA06-600SRG datasheet, BTA06-600SRG pinout, BTA06-600SRG application, or BTA06-600SRG equivalent, key selection criteria include gate sensitivity (5 mA), snubberless commutation performance (dV/dt ≥ 1000 V/µs), insulated tab compliance (UL E81734), and thermal resistance (Rth(j-c) = 2.7 °C/W).
Technical Context
This triac operates in three quadrants (I, II, III) with logic-level gate drive compatibility, enabling direct interfacing with microcontrollers and optocouplers without external amplification. Its snubberless design eliminates need for RC snubbers on inductive loads, supported by high dV/dt immunity (1000 V/µs at Tj = 125°C) and robust commutation margin (dI/dt ≥ 50 A/µs).
The insulated TO-220AB package integrates a ceramic pad to achieve 2500 VRMS isolation between the metal tab and internal die, satisfying UL E81734 requirements. Junction-to-case thermal resistance is 2.7 °C/W, enabling 6 A RMS conduction at Tc = 105°C with appropriate heatsinking.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| IT(RMS) | 6 A - Sustained AC load current handling capability at Tc = 105°C |
| VDRM / VRRM | 600 V - Peak repetitive off-state blocking voltage in both directions |
| IGT (Q1) | 5 mA - Minimum gate current required to trigger conduction in quadrant I |
| dV/dt (min) | 1000 V/µs - Critical rate of rise of off-state voltage before false triggering |
| Rth(j-c) | 2.7 °C/W - Thermal resistance from junction to case, defining heatsink sizing requirement |
| VTM (max) | 1.55 V - Maximum on-state voltage drop at 8.5 A pulse, determining conduction loss |
| Isolation Voltage | 2500 VRMS - Dielectric strength between tab and terminals per UL E81734 |
Pinout & Package
Package: TO-220AB insulated (ceramic-isolated tab), UL-recognized (File E81734), RoHS-compliant ECOPACK® with lead-free second-level interconnect.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| A1 (MT1) | Main Terminal 1 | Reference terminal for gate triggering; connected to load return path in phase-control circuits |
| A2 (MT2) | Main Terminal 2 | High-side AC line connection; carries full load current and defines polarity reference for gate drive |
| G | Gate | Logic-level trigger input (5 mA max); controls conduction onset in quadrants I, II, III only |
Key Features
| Feature | Design Value |
|---|---|
| Snubberless operation | Enables direct drive of inductive loads (e.g., motors, transformers) without external RC snubber networks |
| Logic-level gate sensitivity | 5 mA IGT allows direct interface with MCU GPIOs or low-power optocouplers (e.g., MOC3021) |
| Insulated tab | 2500 VRMS isolation enables safe mounting to grounded heatsinks without additional insulation hardware |
| Three-quadrant triggering | Supports gate triggering only in quadrants I, II, III-improves noise immunity vs. full 4Q devices |
Applications
| Lighting Dimmer Control | Induction Motor Starter |
|---|---|
Use Scenario: Phase-angle controlled AC power delivery to incandescent or halogen lamps. IC Role / Device Role / Timing Role: Main AC power switch triggered by zero-crossing synchronized gate pulses. Use Value: Eliminates snubber components and reduces BOM count while maintaining stable dimming across lamp aging. | Use Scenario: Soft-start circuit for single-phase induction motors in HVAC blowers or pumps. IC Role / Device Role / Timing Role: Inrush current limiter via gradual voltage ramp during startup. Use Value: Prevents contactor welding and extends motor winding life through controlled turn-on dv/dt. |
| Heating Element Regulator | Static Relay Replacement |
Use Scenario: Duty-cycle or phase-control regulation of resistive heating elements in industrial ovens. IC Role / Device Role / Timing Role: High-reliability solid-state replacement for electromechanical contactors. Use Value: Enables >1 million switching cycles with no contact wear, supporting precise temperature setpoint maintenance. | Use Scenario: Solid-state isolation in PLC output modules driving solenoids or valves. IC Role / Device Role / Timing Role: Isolated AC load switch with integrated voltage insulation and surge immunity. Use Value: Meets UL 508 requirements for industrial control panels without auxiliary isolation barriers. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar triac switching applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| BTB06-600SW | Non-insulated TO-220AB package; identical electrical specs except Rth(j-c) = 1.8 °C/W | Requires isolated mounting hardware when heatsink is grounded | Select when mechanical layout permits insulated mounting and thermal performance is prioritized over safety isolation |
| Z0106MN | 6 A/600 V triac with 10 mA IGT; non-snubberless; standard 4-quadrant triggering | Lacks dV/dt immunity (200 V/µs) and requires external snubber for inductive loads | Select only for purely resistive loads or where cost is critical and snubber components are acceptable |
Compared with BTB06-600SW and Z0106MN, BTA06-600SRG uniquely combines logic-level gate drive, snubberless inductive load capability, and certified 2500 VRMS tab isolation-making it optimal for safety-critical, space-constrained, or thermally demanding AC control designs.
Availability
BTA06-600SRG is available at Aetrix Electronics and suitable for lighting dimmers, motor starters, heating regulators, and static relays requiring stable component supply, long-term lifecycle support, and UL-certified isolation.
Supply support for BTA06-600SRG includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
STMicroelectronics is a global semiconductor leader headquartered in Geneva, Switzerland, designing and manufacturing analog, digital, and mixed-signal ICs for automotive, industrial, and consumer markets.
The BTA/BTB06 series belongs to ST's high-reliability power discrete portfolio, engineered specifically for robust AC mains switching in industrial controls, home appliances, and building automation systems.
FAQ
What is the maximum junction temperature for continuous operation?
The BTA06-600SRG has an operating junction temperature range of –40°C to +125°C. Continuous conduction at 6 A RMS requires case temperature ≤105°C, enforced by thermal design using its 2.7 °C/W junction-to-case resistance and adequate heatsinking per Figure 2 in the datasheet.
Can this triac replace a standard 4-quadrant triac in existing designs?
Yes, but only if the gate drive remains in quadrants I, II, or III. BTA06-600SRG is a 3-quadrant device-quadrant IV triggering is not supported. Designs relying on QIV triggering (e.g., certain legacy optocoupler drivers) require verification or substitution with a 4Q part like BTB06-600CW.
Is the insulated tab rated for safety isolation in medical equipment?
No. While UL E81734 certifies 2500 VRMS isolation, BTA06-600SRG is not approved to IEC 60601-1 for medical applications. It meets industrial safety standards (e.g., UL 508, EN 60730) but lacks reinforced insulation and creepage/clearance validation required for patient-connected devices.
Does "RG" in the part number indicate tape-and-reel packaging?
No. "RG" denotes tube packaging (50 units per tube), per Table 8 in the datasheet. Tape-and-reel variants use "RE" suffix (e.g., BTA06-600SRRE). Tube format supports manual assembly and low-volume prototyping, while RE enables automated SMT placement despite TO-220AB being through-hole.
BTA06-600SRG Specifications
- Product attributes
- Attribute value
- Manufacturer:
- STMicroelectronics
- Series:
- -
- Package/Case:
- TO-220-3 Full Pack
- Packaging:
- Tube
- Product Status:
- Active
- Triac Type:
- Logic - Sensitive Gate
- Voltage - Off State:
- 600 V
- Current - On State (It (RMS)) (Max):
- 6 A
- Voltage - Gate Trigger (Vgt) (Max):
- 1.5 V
- Current - Non Rep. Surge 50, 60Hz (Itsm):
- 60A, 63A
- Current - Gate Trigger (Igt) (Max):
- 10 mA
- Current - Hold (Ih) (Max):
- 25 mA
- Configuration:
- Single
- Operating Temperature:
- -40°C ~ 125°C (TJ)
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Through Hole
- Supplier Device Package:
- TO-220AB Insulated
BTA06-600SRG FAQ
1.How can I place an order for BTA06-600SRG through Aetrix?
Please submit a Request for Quotation (RFQ) for BTA06-600SRG on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for BTA06-600SRG reliable?
The price and inventory of BTA06-600SRG are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for BTA06-600SRG is usually 5 days.
3.What payment methods are accepted for BTA06-600SRG?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for BTA06-600SRG transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for BTA06-600SRG?
BTA06-600SRG orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your BTA06-600SRG order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for BTA06-600SRG?
For technical support, including BTA06-600SRG datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your BTA06-600SRG requirements.
6.How does Aetrix verify that BTA06-600SRG is sourced from the original manufacturer or authorized distributors?
All BTA06-600SRG products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that BTA06-600SRG meets industry standards.
7.What is the process for return or replacement of BTA06-600SRG?
All BTA06-600SRG units undergo pre-shipment inspection (PSI). If there is an issue with BTA06-600SRG, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The BTA06-600SRG part is unused and in its original packaging.
Return procedure for BTA06-600SRG:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
BTA06-600SRG Tags

-
Z0103NN5AA4
STMicroelectronics

-
Z0107MNT1G
Littelfuse Inc.

-
Z0103MNT1G
Littelfuse Inc.
;;2.jpg)
-
T405-800B-TR
STMicroelectronics
;;2.jpg)
-
T835-600B-TR
STMicroelectronics
-
2N6073BG
Littelfuse Inc.
-
2N6075BG
Littelfuse Inc.
-
BTA08-600CWRG
STMicroelectronics

-
T835H-6G-TR
STMicroelectronics
-
BTA16-800BRG
STMicroelectronics

-
T1210-800G-TR
STMicroelectronics

-
MAC4DHMT4G
Littelfuse Inc.
Tech Hub
A practical engineering and sourcing framework covering lifecycle verification, lifetime-buy calculations, replacement qualification, supplier checks and counterfeit-risk controls.
TTL and CMOS logic families differ in thresholds, loading, output drive, power and timing. This engineering guide compares 74HC and 74HCT, calculates noise margins and checks 3.3 V/5 V compatibility.
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…