STMicroelectronics BTA10-600CRG

Part No.:
BTA10-600CRG
Manufacturer:
STMicroelectronics
Category:
TRIACs
Package:
TO-220-3
Datasheet:
AetrixBTA10-600CRG.pdf
Description:
TRIAC 600V 10A TO220
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:1,293

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

BTA10-600CRG from STMicroelectronics is a 10 A, 600 V RMS insulated triac in TO-220AB package, designed for AC mains switching in phase-control and ON/OFF applications. It features Snubberless™ 3-quadrant operation, 50 mA gate trigger current (IGT), 1000 V/µs dV/dt immunity at 125 °C, and UL1557-certified 2500 VRMS isolation. Used in heating regulation and motor speed control with inductive loads.

For engineers reviewing the BTA10-600CRG datasheet, BTA10-600CRG pinout, BTA10-600CRG application, or BTA10-600CRG equivalent, key selection criteria include insulated tab rating, commutation robustness on inductive loads, gate sensitivity (25 mA IGT), thermal resistance (Rth(j-c) = 2.4 °C/W), and Snubberless™ 3Q vs standard 4Q operational mode.

Technical Context

This triac operates in three quadrants (I, II, III) with gate-triggered turn-on and natural commutation at current zero-crossing. Its internal ceramic insulation enables 2500 VRMS isolation between tab and MT1/MT2, meeting UL1557 (file E81734). The Snubberless™ design eliminates external snubbers for inductive loads by guaranteeing ≥1000 V/µs dV/dt and ≥9 A/ms (dI/dt)c at 125 °C.

It supports logic-level triggering (VGT ≤ 1.3 V) and maintains stable latching (IL ≤ 70 mA) and holding (IH ≤ 50 mA) currents across –40 to +125 °C junction temperature. Thermal performance is defined by Rth(j-c) = 2.4 °C/W (insulated TO-220AB) and IT(RMS) = 10 A at Tc = 95 °C.

Key Specifications

Parameter Value and Actual Design Meaning
IT(RMS) 10 A - Continuous RMS load current capability at case temperature ≤95 °C
VDRM / VRRM 600 V - Peak repetitive off-state voltage blocking in both directions
IGT (max) 25 mA - Maximum gate trigger current required for reliable turn-on at 25 °C
dV/dt (min) 1000 V/µs - Minimum rate of rise of off-state voltage before false triggering at 125 °C
(dI/dt)c (min) 9 A/ms - Minimum critical rate of decrease of on-state current to ensure commutation on inductive loads
Rth(j-c) 2.4 °C/W - Junction-to-case thermal resistance enabling 10 A operation with heatsink at Tc = 95 °C
Isolation Rating 2500 VRMS - Reinforced insulation between metal tab and main terminals per UL1557

Pinout & Package

Package: TO-220AB Insulated - molded plastic housing with electrically isolated metal tab rated at 2500 VRMS. Tab serves as MT2 terminal and provides mechanical mounting and thermal path.

Pin/Terminal Circuit Role Design Meaning
MT1 (A1) Main Terminal 1 Anode 1 - Primary current entry point; referenced to gate for triggering in Quadrants I/II/III
MT2 (A2) Main Terminal 2 Anode 2 - Current exit path; electrically isolated tab (2500 VRMS) functions as MT2
G Gate Control input - triggers conduction when IGT ≥ 25 mA applied between G and MT1

Key Features

Feature Design Value
Snubberless™ 3Q operation Enables direct drive of inductive loads (e.g., motors, solenoids) without external RC snubber networks
UL1557-certified insulation 2500 VRMS reinforced isolation between tab (MT2) and MT1/G, supporting safety-critical AC mains designs
Low IGT (25 mA) Compatible with microcontroller GPIO or low-power driver ICs without external amplification
High dV/dt immunity (1000 V/µs) Prevents false triggering from voltage transients in noisy industrial AC environments
RoHS-compliant ECOPACK® Meets EU Directive 2002/95/EC; lead-free termination and halogen-free molding compound

Applications

Heating Regulation Induction Motor Starting

Use Scenario: Solid-state replacement for electromechanical relays in electric water heaters and HVAC zone controls.

IC Role / Device Role / Timing Role: Bidirectional AC switch controlling power delivery to resistive heating elements via phase-angle or burst-fire modulation.

Use Value: Enables precise temperature setpoint control with zero-crossing synchronization and >10⁵ cycle lifetime versus relay wear-out.

Use Scenario: Soft-start circuit for single-phase induction motors in washing machines and air conditioners.

IC Role / Device Role / Timing Role: Triac-based phase-controlled voltage ramp during motor startup to limit inrush current.

Use Value: Eliminates need for separate snubber components due to Snubberless™ 3Q architecture and 9 A/ms (dI/dt)c rating.

Light Dimming Appliance Speed Control

Use Scenario: Leading-edge dimmer modules for incandescent and halogen lamps in residential lighting systems.

IC Role / Device Role / Timing Role: Main switching element triggered synchronously with AC zero-crossing to adjust conduction angle per half-cycle.

Use Value: Delivers smooth dimming down to 5% brightness with minimal EMI due to controlled dV/dt and gate-trigger precision.

Use Scenario: Variable-speed control for universal motors in vacuum cleaners and power tools.

IC Role / Device Role / Timing Role: AC power modulator regulating average torque/speed via phase-cutting in line-frequency AC supply.

Use Value: Supports compact PCB layout with integrated 2500 VRMS isolation-no creepage/clearance spacing required between MT2 tab and PCB ground.

Equivalent & Alternatives

The following parts are listed as comparable options for similar triac-based AC switching applications.

Alternative Part Technical Difference Application Difference Selection Advice
BTA10-600BW Same package and voltage rating, but 50 mA IGT (vs 25 mA); standard 4-quadrant operation (not Snubberless™) Lacks 3Q commutation robustness; requires external snubber for inductive loads Select only if gate drive strength exceeds 50 mA and load is resistive or lightly inductive
T1035-6G D²PAK surface-mount package; 35 mA IGT; same Snubberless™ 3Q spec; Rth(j-c) = 1.5 °C/W No insulated tab; requires PCB isolation design; better thermal performance but no 2500 VRMS certification Choose for space-constrained SMT designs where UL-rated isolation is handled at system level

Compared with BTA10-600BW, the CRG variant offers lower gate drive demand and superior inductive-load commutation; versus T1035-6G, it trades SMT compatibility for certified reinforced isolation and through-hole mechanical robustness in high-vibration environments.

Availability

BTA10-600CRG is available at Aetrix Electronics and suitable for heating regulation, motor starting, light dimming, and appliance speed control requiring stable component supply, long-lifecycle support, and UL-certified isolation.

Supply support for BTA10-600CRG includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

STMicroelectronics is a global semiconductor leader headquartered in Geneva, Switzerland, designing and manufacturing analog, power, MCU, and sensor solutions for industrial, automotive, and consumer markets.

BTA10-600CRG belongs to ST's high-reliability AC power switching portfolio, engineered specifically for robust, isolated, snubberless triac control in mains-powered appliances and industrial equipment.

FAQ

What is the maximum allowable case temperature for continuous 10 A operation?

The BTA10-600CRG supports 10 A RMS continuous current at a maximum case temperature (Tc) of 95 °C, as specified in Table 1 of DS3165 Rev 9. Exceeding this temperature reduces safe operating current per the derating curve in Figure 3. Thermal design must ensure heatsink interface resistance and ambient conditions maintain Tc ≤ 95 °C under full load.

Does the insulated tab require electrical connection to circuit ground?

No-the insulated tab is electrically isolated (2500 VRMS) and serves solely as MT2 and thermal interface. It may be mounted directly to a grounded heatsink without creating a safety hazard or short circuit. This allows simplified mechanical mounting while maintaining reinforced insulation between mains-side terminals and chassis ground.

Can BTA10-600CRG replace a standard 4-quadrant triac in existing designs?

Yes, but only if the application uses Quadrants I, II, or III-and avoids Quadrant IV triggering. The CRG variant is optimized for 3Q operation; its gate sensitivity and commutation specs are guaranteed only in those quadrants. For legacy 4Q circuits requiring IV quadrant turn-on, BTA10-600BW is the appropriate drop-in alternative.

What is the minimum gate pulse width required for reliable triggering?

A minimum gate pulse width of 20 µs is required to ensure turn-on, based on the IGM (peak gate current) test condition in Table 1 (tp = 20 µs). Shorter pulses risk incomplete triggering, especially at elevated junction temperatures. Gate drivers should deliver ≥4 A peak current for ≥20 µs into the 25 mA IGT-rated device.

BTA10-600CRG Specifications

Product attributes
Attribute value
Manufacturer:
STMicroelectronics
Series:
-
Package/Case:
TO-220-3
Packaging:
Tube
Product Status:
Active
Triac Type:
Standard
Voltage - Off State:
600 V
Current - On State (It (RMS)) (Max):
10 A
Voltage - Gate Trigger (Vgt) (Max):
1.3 V
Current - Non Rep. Surge 50, 60Hz (Itsm):
100A, 105A
Current - Gate Trigger (Igt) (Max):
25 mA
Current - Hold (Ih) (Max):
25 mA
Configuration:
Single
Operating Temperature:
-40°C ~ 125°C (TJ)
Grade:
-
Qualification:
-
Mounting Type:
Through Hole
Supplier Device Package:
TO-220

BTA10-600CRG FAQ

1.How can I place an order for BTA10-600CRG through Aetrix?

Please submit a Request for Quotation (RFQ) for BTA10-600CRG on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for BTA10-600CRG reliable?

The price and inventory of BTA10-600CRG are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for BTA10-600CRG is usually 5 days.

3.What payment methods are accepted for BTA10-600CRG?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for BTA10-600CRG transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for BTA10-600CRG?

BTA10-600CRG orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your BTA10-600CRG order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for BTA10-600CRG?

For technical support, including BTA10-600CRG datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your BTA10-600CRG requirements.

6.How does Aetrix verify that BTA10-600CRG is sourced from the original manufacturer or authorized distributors?

All BTA10-600CRG products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that BTA10-600CRG meets industry standards.

7.What is the process for return or replacement of BTA10-600CRG?

All BTA10-600CRG units undergo pre-shipment inspection (PSI). If there is an issue with BTA10-600CRG, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The BTA10-600CRG part is unused and in its original packaging.

Return procedure for BTA10-600CRG:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

BTA10-600CRG Tags

  • BTA10-600CRG
  • BTA10-600CRG PDF
  • BTA10-600CRG Datasheet
  • BTA10-600CRG Specifications
  • BTA10-600CRG Images
  • STMicroelectronics
  • STMicroelectronics BTA10-600CRG
  • Buy BTA10-600CRG
  • BTA10-600CRG Price
  • BTA10-600CRG Distributor
  • BTA10-600CRG Supplier
  • BTA10-600CRG Wholesale
Related Products
Z0103NN5AA4
Z0103NN5AA4

STMicroelectronics

Z0107MNT1G
Z0107MNT1G

Littelfuse Inc.

Z0103MNT1G
Z0103MNT1G

Littelfuse Inc.

T405-800B-TR
T405-800B-TR

STMicroelectronics

T835-600B-TR
T835-600B-TR

STMicroelectronics

2N6073BG
2N6073BG

Littelfuse Inc.

2N6075BG
2N6075BG

Littelfuse Inc.

BTA08-600CWRG
BTA08-600CWRG

STMicroelectronics

T835H-6G-TR
T835H-6G-TR

STMicroelectronics

BTA16-800BRG
BTA16-800BRG

STMicroelectronics

T1210-800G-TR
T1210-800G-TR

STMicroelectronics

MAC4DHMT4G
MAC4DHMT4G

Littelfuse Inc.

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER