STMicroelectronics BTA10-600CRG
- Part No.:
- BTA10-600CRG
- Manufacturer:
- STMicroelectronics
- Category:
- TRIACs
- Package:
- TO-220-3
- Datasheet:
-
BTA10-600CRG.pdf
- Description:
- TRIAC 600V 10A TO220
- Quantity:
- Payment:

- Shipping:

Inventory:1,293
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
BTA10-600CRG from STMicroelectronics is a 10 A, 600 V RMS insulated triac in TO-220AB package, designed for AC mains switching in phase-control and ON/OFF applications. It features Snubberless™ 3-quadrant operation, 50 mA gate trigger current (IGT), 1000 V/µs dV/dt immunity at 125 °C, and UL1557-certified 2500 VRMS isolation. Used in heating regulation and motor speed control with inductive loads.
For engineers reviewing the BTA10-600CRG datasheet, BTA10-600CRG pinout, BTA10-600CRG application, or BTA10-600CRG equivalent, key selection criteria include insulated tab rating, commutation robustness on inductive loads, gate sensitivity (25 mA IGT), thermal resistance (Rth(j-c) = 2.4 °C/W), and Snubberless™ 3Q vs standard 4Q operational mode.
Technical Context
This triac operates in three quadrants (I, II, III) with gate-triggered turn-on and natural commutation at current zero-crossing. Its internal ceramic insulation enables 2500 VRMS isolation between tab and MT1/MT2, meeting UL1557 (file E81734). The Snubberless™ design eliminates external snubbers for inductive loads by guaranteeing ≥1000 V/µs dV/dt and ≥9 A/ms (dI/dt)c at 125 °C.
It supports logic-level triggering (VGT ≤ 1.3 V) and maintains stable latching (IL ≤ 70 mA) and holding (IH ≤ 50 mA) currents across –40 to +125 °C junction temperature. Thermal performance is defined by Rth(j-c) = 2.4 °C/W (insulated TO-220AB) and IT(RMS) = 10 A at Tc = 95 °C.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| IT(RMS) | 10 A - Continuous RMS load current capability at case temperature ≤95 °C |
| VDRM / VRRM | 600 V - Peak repetitive off-state voltage blocking in both directions |
| IGT (max) | 25 mA - Maximum gate trigger current required for reliable turn-on at 25 °C |
| dV/dt (min) | 1000 V/µs - Minimum rate of rise of off-state voltage before false triggering at 125 °C |
| (dI/dt)c (min) | 9 A/ms - Minimum critical rate of decrease of on-state current to ensure commutation on inductive loads |
| Rth(j-c) | 2.4 °C/W - Junction-to-case thermal resistance enabling 10 A operation with heatsink at Tc = 95 °C |
| Isolation Rating | 2500 VRMS - Reinforced insulation between metal tab and main terminals per UL1557 |
Pinout & Package
Package: TO-220AB Insulated - molded plastic housing with electrically isolated metal tab rated at 2500 VRMS. Tab serves as MT2 terminal and provides mechanical mounting and thermal path.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| MT1 (A1) | Main Terminal 1 | Anode 1 - Primary current entry point; referenced to gate for triggering in Quadrants I/II/III |
| MT2 (A2) | Main Terminal 2 | Anode 2 - Current exit path; electrically isolated tab (2500 VRMS) functions as MT2 |
| G | Gate | Control input - triggers conduction when IGT ≥ 25 mA applied between G and MT1 |
Key Features
| Feature | Design Value |
|---|---|
| Snubberless™ 3Q operation | Enables direct drive of inductive loads (e.g., motors, solenoids) without external RC snubber networks |
| UL1557-certified insulation | 2500 VRMS reinforced isolation between tab (MT2) and MT1/G, supporting safety-critical AC mains designs |
| Low IGT (25 mA) | Compatible with microcontroller GPIO or low-power driver ICs without external amplification |
| High dV/dt immunity (1000 V/µs) | Prevents false triggering from voltage transients in noisy industrial AC environments |
| RoHS-compliant ECOPACK® | Meets EU Directive 2002/95/EC; lead-free termination and halogen-free molding compound |
Applications
| Heating Regulation | Induction Motor Starting |
|---|---|
|
Use Scenario: Solid-state replacement for electromechanical relays in electric water heaters and HVAC zone controls. IC Role / Device Role / Timing Role: Bidirectional AC switch controlling power delivery to resistive heating elements via phase-angle or burst-fire modulation. Use Value: Enables precise temperature setpoint control with zero-crossing synchronization and >10⁵ cycle lifetime versus relay wear-out. |
Use Scenario: Soft-start circuit for single-phase induction motors in washing machines and air conditioners. IC Role / Device Role / Timing Role: Triac-based phase-controlled voltage ramp during motor startup to limit inrush current. Use Value: Eliminates need for separate snubber components due to Snubberless™ 3Q architecture and 9 A/ms (dI/dt)c rating. |
| Light Dimming | Appliance Speed Control |
|
Use Scenario: Leading-edge dimmer modules for incandescent and halogen lamps in residential lighting systems. IC Role / Device Role / Timing Role: Main switching element triggered synchronously with AC zero-crossing to adjust conduction angle per half-cycle. Use Value: Delivers smooth dimming down to 5% brightness with minimal EMI due to controlled dV/dt and gate-trigger precision. |
Use Scenario: Variable-speed control for universal motors in vacuum cleaners and power tools. IC Role / Device Role / Timing Role: AC power modulator regulating average torque/speed via phase-cutting in line-frequency AC supply. Use Value: Supports compact PCB layout with integrated 2500 VRMS isolation-no creepage/clearance spacing required between MT2 tab and PCB ground. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar triac-based AC switching applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| BTA10-600BW | Same package and voltage rating, but 50 mA IGT (vs 25 mA); standard 4-quadrant operation (not Snubberless™) | Lacks 3Q commutation robustness; requires external snubber for inductive loads | Select only if gate drive strength exceeds 50 mA and load is resistive or lightly inductive |
| T1035-6G | D²PAK surface-mount package; 35 mA IGT; same Snubberless™ 3Q spec; Rth(j-c) = 1.5 °C/W | No insulated tab; requires PCB isolation design; better thermal performance but no 2500 VRMS certification | Choose for space-constrained SMT designs where UL-rated isolation is handled at system level |
Compared with BTA10-600BW, the CRG variant offers lower gate drive demand and superior inductive-load commutation; versus T1035-6G, it trades SMT compatibility for certified reinforced isolation and through-hole mechanical robustness in high-vibration environments.
Availability
BTA10-600CRG is available at Aetrix Electronics and suitable for heating regulation, motor starting, light dimming, and appliance speed control requiring stable component supply, long-lifecycle support, and UL-certified isolation.
Supply support for BTA10-600CRG includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
STMicroelectronics is a global semiconductor leader headquartered in Geneva, Switzerland, designing and manufacturing analog, power, MCU, and sensor solutions for industrial, automotive, and consumer markets.
BTA10-600CRG belongs to ST's high-reliability AC power switching portfolio, engineered specifically for robust, isolated, snubberless triac control in mains-powered appliances and industrial equipment.
FAQ
What is the maximum allowable case temperature for continuous 10 A operation?
The BTA10-600CRG supports 10 A RMS continuous current at a maximum case temperature (Tc) of 95 °C, as specified in Table 1 of DS3165 Rev 9. Exceeding this temperature reduces safe operating current per the derating curve in Figure 3. Thermal design must ensure heatsink interface resistance and ambient conditions maintain Tc ≤ 95 °C under full load.
Does the insulated tab require electrical connection to circuit ground?
No-the insulated tab is electrically isolated (2500 VRMS) and serves solely as MT2 and thermal interface. It may be mounted directly to a grounded heatsink without creating a safety hazard or short circuit. This allows simplified mechanical mounting while maintaining reinforced insulation between mains-side terminals and chassis ground.
Can BTA10-600CRG replace a standard 4-quadrant triac in existing designs?
Yes, but only if the application uses Quadrants I, II, or III-and avoids Quadrant IV triggering. The CRG variant is optimized for 3Q operation; its gate sensitivity and commutation specs are guaranteed only in those quadrants. For legacy 4Q circuits requiring IV quadrant turn-on, BTA10-600BW is the appropriate drop-in alternative.
What is the minimum gate pulse width required for reliable triggering?
A minimum gate pulse width of 20 µs is required to ensure turn-on, based on the IGM (peak gate current) test condition in Table 1 (tp = 20 µs). Shorter pulses risk incomplete triggering, especially at elevated junction temperatures. Gate drivers should deliver ≥4 A peak current for ≥20 µs into the 25 mA IGT-rated device.
BTA10-600CRG Specifications
- Product attributes
- Attribute value
- Manufacturer:
- STMicroelectronics
- Series:
- -
- Package/Case:
- TO-220-3
- Packaging:
- Tube
- Product Status:
- Active
- Triac Type:
- Standard
- Voltage - Off State:
- 600 V
- Current - On State (It (RMS)) (Max):
- 10 A
- Voltage - Gate Trigger (Vgt) (Max):
- 1.3 V
- Current - Non Rep. Surge 50, 60Hz (Itsm):
- 100A, 105A
- Current - Gate Trigger (Igt) (Max):
- 25 mA
- Current - Hold (Ih) (Max):
- 25 mA
- Configuration:
- Single
- Operating Temperature:
- -40°C ~ 125°C (TJ)
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Through Hole
- Supplier Device Package:
- TO-220
BTA10-600CRG FAQ
1.How can I place an order for BTA10-600CRG through Aetrix?
Please submit a Request for Quotation (RFQ) for BTA10-600CRG on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for BTA10-600CRG reliable?
The price and inventory of BTA10-600CRG are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for BTA10-600CRG is usually 5 days.
3.What payment methods are accepted for BTA10-600CRG?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for BTA10-600CRG transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for BTA10-600CRG?
BTA10-600CRG orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your BTA10-600CRG order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for BTA10-600CRG?
For technical support, including BTA10-600CRG datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your BTA10-600CRG requirements.
6.How does Aetrix verify that BTA10-600CRG is sourced from the original manufacturer or authorized distributors?
All BTA10-600CRG products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that BTA10-600CRG meets industry standards.
7.What is the process for return or replacement of BTA10-600CRG?
All BTA10-600CRG units undergo pre-shipment inspection (PSI). If there is an issue with BTA10-600CRG, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The BTA10-600CRG part is unused and in its original packaging.
Return procedure for BTA10-600CRG:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
BTA10-600CRG Tags

-
Z0103NN5AA4
STMicroelectronics

-
Z0107MNT1G
Littelfuse Inc.

-
Z0103MNT1G
Littelfuse Inc.
;;2.jpg)
-
T405-800B-TR
STMicroelectronics
;;2.jpg)
-
T835-600B-TR
STMicroelectronics
-
2N6073BG
Littelfuse Inc.
-
2N6075BG
Littelfuse Inc.
-
BTA08-600CWRG
STMicroelectronics

-
T835H-6G-TR
STMicroelectronics
-
BTA16-800BRG
STMicroelectronics

-
T1210-800G-TR
STMicroelectronics

-
MAC4DHMT4G
Littelfuse Inc.
Tech Hub
Schmitt triggers use separate rising and falling thresholds to stabilize slow or noisy signals. This guide covers hysteresis, 74HC14 and 74HCT14 selection, comparator calculations, RC oscillators and p…
Counterfeit components can hide behind convincing markings and passing basic function tests. This engineering reference covers source traceability, external inspection, X-ray, XRF, electrical testing, …
A practical engineering and sourcing framework covering lifecycle verification, lifetime-buy calculations, replacement qualification, supplier checks and counterfeit-risk controls.
TTL and CMOS logic families differ in thresholds, loading, output drive, power and timing. This engineering guide compares 74HC and 74HCT, calculates noise margins and checks 3.3 V/5 V compatibility.
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…