UMW BTA16-600BWRG
- Part No.:
- BTA16-600BWRG
- Manufacturer:
- UMW
- Category:
- TRIACs
- Package:
- TO-220-3
- Datasheet:
-
BTA16-600BWRG.pdf
- Description:
- TRIAC ALTERNISTOR 600V 16A TO220
- Quantity:
- Payment:

- Shipping:

Inventory:950
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
BTA16-600BWRG from STMicroelectronics is a 16 A, 600 V RMS insulated triac in TO-220AB Ins. package, designed for snubberless AC phase control and switching in inductive mains-powered loads. It features 50 mA gate trigger current (IGT), 2500 VRMS insulated tab, and high commutation capability (dV/dt ≥ 1000 V/µs, dI/dt ≥ 14 A/ms) at 125 °C - enabling reliable operation in motor speed controllers and static relays without external snubbers.
For engineers reviewing the BTA16-600BWRG datasheet, BTA16-600BWRG pinout, BTA16-600BWRG application, or BTA16-600BWRG equivalent, key selection criteria include insulated tab voltage rating, snubberless commutation performance under inductive load stress, thermal resistance (Rth(j-c) = 2.1 °C/W), and gate sensitivity compatibility with microcontroller-driven zero-crossing or phase-angle drivers.
Technical Context
This triac operates in three quadrants (I, III, IV) with logic-compatible gate drive and is optimized for high-noise industrial environments where rapid voltage transients occur across inductive loads. Its internal ceramic insulation enables safe mounting to grounded heatsinks while maintaining 2500 VRMS isolation between MT2 and case.
The device delivers stable latching (IL ≤ 70 mA) and holding (IH ≤ 50 mA) behavior over –40 to +125 °C junction temperature, with on-state voltage as low as 0.85 V at 125 °C and dynamic resistance of 25 mΩ - minimizing conduction losses in continuous-duty applications like HVAC fan control and appliance heating regulation.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| IT(RMS) | 16 A - supports continuous AC load current up to 16 A at Tc = 86 °C with standard heatsinking |
| VDRM / VRRM | 600 V - blocks 600 V peak reverse/repetitive off-state voltage, suitable for 230 VAC mains with safety margin |
| IGT (Snubberless) | 50 mA - gate trigger current required to initiate conduction; compatible with standard optocoupler drivers (e.g., MOC3041) |
| (dV/dt)c | 1000 V/µs - critical rate of rise of off-state voltage before false triggering; eliminates need for RC snubber on inductive loads |
| Rth(j-c) | 2.1 °C/W - junction-to-case thermal resistance enables efficient heat transfer to heatsink in insulated TO-220AB package |
| Insulation Rating | 2500 VRMS - certified isolated tab allows direct mounting to grounded metal chassis without additional insulation |
| UL Certification | UL1557 file E81734 - validates reinforced insulation system for safety-critical AC power control applications |
Pinout & Package
Package: TO-220AB Insulated - epoxy-encapsulated, UL94 V0 rated, with insulated metal tab (MT2) electrically isolated from semiconductor die. Mounting torque: 0.55 N·m (recommended), max 0.70 N·m.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| A1 (MT1) | Main Terminal 1 | Reference terminal for gate trigger; connected to load return or neutral side in typical AC switch configuration |
| A2 (MT2) | Main Terminal 2 | High-side AC line connection; electrically isolated tab enables safe heatsink mounting at chassis ground potential |
| G | Gate | Control input requiring ≥50 mA pulse (12 V, 30 Ω load) to trigger conduction in quadrants I, III, IV; negative-going pulses not required |
Key Features
| Feature | Design Value |
|---|---|
| Snubberless™ Commutation | 1000 V/µs dV/dt immunity at 125 °C enables direct drive of inductive loads (e.g., universal motors) without external RC networks |
| Insulated Tab | 2500 VRMS isolation between MT2 and heatsink meets reinforced insulation requirements for Class I appliances and industrial controls |
| Low Thermal Resistance | 2.1 °C/W junction-to-case enables 16 A RMS operation with modest heatsinking - reduces system size vs. non-insulated alternatives |
| UL1557 Certification | File E81734 confirms compliance with safety standards for solid-state relays and AC power controllers in end equipment |
| RoHS Compliant | Meets EU Directive 2002/95/EC; lead-free terminations and halogen-free molding compound support environmentally regulated manufacturing |
Applications
| Industrial Motor Control | Smart Appliance Power Regulation |
|---|---|
|
Use Scenario: Variable-speed control of single-phase induction motors in HVAC blowers and pump systems operating from 230 VAC mains. IC Role / Device Role / Timing Role: Snubberless triac acting as phase-angle controlled AC power switch, triggered by zero-crossing detector and MCU PWM timing logic. Use Value: Eliminates snubber components and associated PCB space/cost while sustaining >100,000-cycle reliability under full-load inductive switching stress. |
Use Scenario: Power modulation for heating elements and brushless DC fan drives in premium ovens and washing machines. IC Role / Device Role / Timing Role: Isolated AC switch enabling microcontroller-safe control of 230 VAC loads via optocoupled gate driver. Use Value: 2500 VRMS insulated tab permits direct mounting to grounded appliance chassis - simplifying mechanical design and reducing EMI filter complexity. |
| Static Relay Replacement | Lighting Dimmer Module |
|
Use Scenario: Solid-state replacement for electromechanical relays in programmable logic controller (PLC) output modules handling 16 A resistive/inductive loads. IC Role / Device Role / Timing Role: High-reliability AC switching element with fast turn-off and high dI/dt immunity to prevent contact welding failure modes. Use Value: 14 A/ms critical rate of decrease of main current ensures clean commutation during zero-crossing interruption - extending service life beyond 1 million operations. |
Use Scenario: Leading-edge dimmer circuit for LED-compatible incandescent/halogen lamps in residential smart lighting systems. IC Role / Device Role / Timing Role: Phase-controlled AC switch synchronized to line voltage zero crossings, driven by analog or digital dimming signal. Use Value: 50 mA gate sensitivity ensures robust triggering even with aging optocouplers; low VT(ON) (0.85 V @ 125 °C) minimizes self-heating at partial conduction angles. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar snubberless triac applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| BTA16-600CW | 35 mA IGT (vs. 50 mA); same package, insulation, and voltage rating | Lower gate drive requirement suits weak-output microcontrollers or high-impedance optocouplers (e.g., MOC3021) | Select when gate drive current budget is constrained; verify latching margin with actual load characteristics |
| T1650-600G | D²PAK surface-mount package; 50 mA IGT; Rth(j-c) = 1.2 °C/W; no insulated tab | Requires PCB-level isolation and heatsink design; higher power density but no chassis-ground mounting option | Choose for automated assembly and compact designs where chassis grounding is handled elsewhere in system layout |
Compared with BTA16-600CW, the BTA16-600BWRG offers higher gate drive margin for noisy environments; compared with T1650-600G, it provides certified insulation for direct chassis mounting - making it preferred for safety-critical, manually assembled industrial controls.
Availability
BTA16-600BWRG is available at Aetrix Electronics and suitable for industrial motor control, smart appliance power regulation, static relay replacement, and lighting dimmer modules requiring stable component supply, long-term lifecycle support, and certified insulation integrity.
Supply support for BTA16-600BWRG includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
STMicroelectronics is a global semiconductor leader headquartered in Geneva, Switzerland, specializing in power management, analog, MEMS, and microcontroller technologies for industrial, automotive, and consumer markets.
The BTA16 series belongs to ST's high-reliability AC power switching portfolio, engineered specifically for snubberless operation in inductive load environments - emphasizing safety certification, thermal efficiency, and long-term manufacturability in industrial controls.
FAQ
What does the 'BW' suffix indicate in BTA16-600BWRG?
The 'BW' suffix denotes a Snubberless™ triac with 50 mA gate trigger current (IGT) and insulated TO-220AB package. It confirms compliance with high commutation performance (dV/dt ≥ 1000 V/µs at 125 °C) and 2500 VRMS isolation - distinguishing it from standard ('B') or lower-sensitivity ('C', 'SW', 'CW') variants in the same voltage/current class.
Can BTA16-600BWRG be used without a heatsink?
No - at 16 A RMS, the device dissipates significant power (VT × IT ≈ 1.2 W minimum, up to >10 W depending on conduction angle). With Rth(j-c) = 2.1 °C/W and max Tj = 125 °C, even at ambient 25 °C, junction temperature would exceed limits without a heatsink. A minimum 10 cm² aluminum heatsink is recommended for continuous operation.
Is the insulated tab rated for continuous 2500 VRMS or only for dielectric testing?
The 2500 VRMS rating is a continuous working voltage per UL1557 certification (file E81734), not just a test value. It defines the maximum RMS voltage that may be sustained between MT2 (tab) and any conductive surface - enabling safe mounting to grounded metal enclosures in Class I equipment without additional insulating hardware.
How does BTA16-600BWRG differ from BTB16-600BWRG?
BTA16-600BWRG uses an insulated TO-220AB package (2500 VRMS tab isolation), while BTB16-600BWRG uses a non-insulated TO-220AB package. Both share identical electrical specs (16 A, 600 V, 50 mA IGT, Snubberless™), but only the BTA variant permits direct mounting to grounded heatsinks - critical for safety-compliant industrial designs.
BTA16-600BWRG Specifications
- Product attributes
- Attribute value
- Manufacturer:
- UMW
- Series:
- -
- Package/Case:
- TO-220-3
- Packaging:
- Tube
- Product Status:
- Active
- Triac Type:
- Standard
- Voltage - Off State:
- 600 V
- Current - On State (It (RMS)) (Max):
- 16 A
- Voltage - Gate Trigger (Vgt) (Max):
- 1.5 V
- Current - Non Rep. Surge 50, 60Hz (Itsm):
- 160A @ 50Hz
- Current - Gate Trigger (Igt) (Max):
- 35 mA
- Current - Hold (Ih) (Max):
- 60 mA
- Configuration:
- Single
- Operating Temperature:
- -40°C ~ 150°C (TJ)
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Through Hole
- Supplier Device Package:
- TO-220A
BTA16-600BWRG FAQ
1.How can I place an order for BTA16-600BWRG through Aetrix?
Please submit a Request for Quotation (RFQ) for BTA16-600BWRG on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for BTA16-600BWRG reliable?
The price and inventory of BTA16-600BWRG are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for BTA16-600BWRG is usually 5 days.
3.What payment methods are accepted for BTA16-600BWRG?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for BTA16-600BWRG transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for BTA16-600BWRG?
BTA16-600BWRG orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your BTA16-600BWRG order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for BTA16-600BWRG?
For technical support, including BTA16-600BWRG datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your BTA16-600BWRG requirements.
6.How does Aetrix verify that BTA16-600BWRG is sourced from the original manufacturer or authorized distributors?
All BTA16-600BWRG products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that BTA16-600BWRG meets industry standards.
7.What is the process for return or replacement of BTA16-600BWRG?
All BTA16-600BWRG units undergo pre-shipment inspection (PSI). If there is an issue with BTA16-600BWRG, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The BTA16-600BWRG part is unused and in its original packaging.
Return procedure for BTA16-600BWRG:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
BTA16-600BWRG Tags

-
Z0103NN5AA4
STMicroelectronics

-
Z0107MNT1G
Littelfuse Inc.

-
Z0103MNT1G
Littelfuse Inc.
;;2.jpg)
-
T405-800B-TR
STMicroelectronics
;;2.jpg)
-
T835-600B-TR
STMicroelectronics
-
2N6073BG
Littelfuse Inc.
-
2N6075BG
Littelfuse Inc.
-
BTA08-600CWRG
STMicroelectronics

-
T835H-6G-TR
STMicroelectronics
-
BTA16-800BRG
STMicroelectronics

-
T1210-800G-TR
STMicroelectronics

-
MAC4DHMT4G
Littelfuse Inc.
Tech Hub
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…
LDO regulator guide covering low dropout voltage, power dissipation, thermal design, PSRR, output noise, capacitor stability, adjustable LDO circuits, LDO vs buck converter and datasheet selection chec…
Conditional Access Module guide covering CAM meaning, CI/CI+ interface, smart card authorization, DVB security workflow, TV and set-top box compatibility, internal electronics, ESD protection, connecto…
Guide to electronic component obsolescence covering EOL risk, PCN/PDN notices, last-time buy planning, replacement options, form-fit-function validation, counterfeit risk and BOM lifecycle management.
18650 battery guide covering lithium-ion cell basics, 3.6V/3.7V voltage, 4.2V charging, mAh and Wh capacity, protected cells, chargers, BMS, series-parallel packs, holders, welding and sourcing checks.…
Hall effect sensor guide covering working principle, linear and digital sensors, Arduino circuits, current sensing, speed detection, automotive applications, A3144 examples, signal filtering and datash…
Product Change Notification guide for electronic components, covering PCN meaning, PCN vs PDN/EOL, common change types, risk levels, form-fit-function review, engineering validation, BOM control, LTB/L…
A practical guide to blend door actuators, covering HVAC function, symptoms, location, AC and heater issues, reset and calibration, replacement cost, electrical diagnosis, compatibility checks, and rep…