BTA316-600BT,127 from WeEn Semiconductors is a 4-quadrant logic-level sensitive triac rated for 600 V blocking voltage and 16 A RMS on-state current, designed for AC power control in mains-connected appliances such as induction cooktops and washing machine motor drives. It features low gate trigger current (IGT ≤ 15 mA), high commutation robustness (dI/dt ≥ 20 A/μs), and meets IEC 61000-4-4 EFT immunity requirements.
For engineers reviewing the BTA316-600BT,127 datasheet, BTA316-600BT,127 pinout, BTA316-600BT,127 application, or BTA316-600BT,127 equivalent, key selection criteria include its snubberless operation capability, 125 °C maximum junction temperature, and compatibility with zero-crossing and phase-angle dimming control topologies in 230 V AC systems.
Technical Context
This triac operates in all four quadrants (I+, I−, III+, III−) without requiring external snubbers due to built-in overvoltage clamping and enhanced dv/dt immunity (≥ 1000 V/μs). Its gate sensitivity enables direct drive from microcontrollers or optocouplers without amplification.
The device uses planar passivation technology for stable performance across temperature and lifetime, supporting reliable switching in high-humidity and thermally cycling environments typical of white goods and industrial controls.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| VDRM/VRWM | 600 V - Sustains peak line voltage in 230 V AC mains with safety margin |
| IT(RMS) | 16 A - Supports continuous load current for 3.5 kW resistive heating elements |
| IGT | ≤15 mA - Enables direct MCU GPIO or low-power optocoupler (e.g., MOC3021) drive |
| dI/dt (crit) | ≥20 A/μs - Prevents false turn-on during fast current transients in inductive motor loads |
| Tj(max) | 125 °C - Allows operation in sealed enclosures with limited airflow |
| dv/dt (crit) | ≥1000 V/μs - Eliminates need for external snubber networks in most applications |
Pinout & Package
Package: TO-220AB (3-pin, straight lead, insulated tab). Mounting requires thermal interface material and mechanical isolation per IEC 61800-5-1.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| MT1 | Main Terminal 1 | Anode-side current path; connected to load return or neutral in AC circuits |
| MT2 | Main Terminal 2 | Cathode-side current path; connected to AC line or hot side in standard configuration |
| G | Gate | Control input; triggers conduction when referenced to MT1 with ≥15 mA pulse |
Key Features
| Feature | Design Value |
|---|---|
| Snubberless operation | Validated for 230 V AC resistive and inductive loads without RC snubber network |
| High dv/dt immunity | 1000 V/μs minimum ensures no spurious triggering from EMI or switching noise |
| Logic-level gate drive | IGT ≤15 mA allows direct interface with 3.3 V/5 V MCUs and standard optocouplers |
| Enhanced surge rating | IFSM = 160 A (50 Hz half-sine) supports repeated inrush currents in motor start-up |
Applications
| Induction Cooking Control | Washing Machine Motor Drive |
|---|---|
Use Scenario: Precise power regulation of resonant LC tank in domestic induction hobs using phase-angle control. IC Role / Device Role / Timing Role: Main AC power switch enabling bidirectional current flow and zero-voltage switching transitions. Use Value: Enables 12-bit power resolution with <1% output drift over 10,000 cycles at 125 °C junction temperature. | Use Scenario: Speed and direction control of universal brushed motors in drum washers via AC phase-cutting. IC Role / Device Role / Timing Role: Bidirectional AC switch synchronized to zero-crossing detection for EMI reduction. Use Value: Reduces conducted emissions by 15 dB compared to mechanical relays while maintaining >100,000 cycle lifetime. |
| Smart Meter Load Switching | Industrial HVAC Fan Control |
Use Scenario: Remote-controlled disconnection of tariff-based loads in Class 0.5S smart electricity meters. IC Role / Device Role / Timing Role: Isolated mains disconnect switch triggered by microcontroller via optocoupler. Use Value: Meets IEC 62053-21 leakage current limits (<0.5 mA) and withstands 10 kV impulse tests. | Use Scenario: Variable-speed control of 3-phase fan motors in air handling units using single-phase triac pre-control. IC Role / Device Role / Timing Role: Pre-regulator stage limiting inrush before full SCR bridge activation. Use Value: Cuts startup current surge by 65%, extending contactor life and reducing transformer stress. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar triac-based AC power control applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| STMicroelectronics BTB16-600BW | Same 16 A/600 V rating but higher IGT (≤25 mA); TO-220 insulated package | Requires gate driver buffer for 3.3 V MCU interfaces; lower dI/dt (10 A/μs) | Prefer when legacy ST ecosystem integration or AEC-Q101 qualification is required |
| Littelfuse Q6016LH4 | 16 A/600 V, logic-level (IGT ≤10 mA), but non-insulated TO-220 package | Needs heatsink isolation; higher dv/dt (1500 V/μs) but no EFT certification | Choose for cost-sensitive industrial controls where thermal management permits non-insulated mounting |
Compared with BTB16-600BW and Q6016LH4, the BTA316-600BT,127 delivers superior EFT immunity and snubberless reliability in humid environments, making it preferred for consumer appliance certifications requiring IEC 60335-1 Annex G compliance.
Availability
BTA316-600BT,127 is available at Aetrix Electronics and suitable for induction cooking, smart meter load switching, and washing machine motor control requiring stable component supply across multi-year production programs.
Supply support for BTA316-600BT,127 includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
WeEn Semiconductors is a professional power device supplier spun off from NXP, with over 50 years' experience in power semiconductors and 8000+ global customers.
The BTA316-600BT,127 belongs to WeEn's 4Q Standard Triacs product line, engineered specifically for high-reliability AC power control in consumer white goods and industrial equipment operating up to 125 °C ambient.
FAQ
What is the maximum junction temperature rating for the BTA316-600BT,127?
The BTA316-600BT,127 has a maximum junction temperature (Tj(max)) of 125 °C, validated under steady-state and transient thermal conditions per JEDEC JESD51 standards. This rating enables use in sealed enclosures with limited airflow, provided PCB copper area and heatsink design maintain θJA ≤ 35 °C/W. Derating curves in the official BTA316-600BT,127 datasheet specify safe operating area limits above 100 °C ambient.
Does the BTA316-600BT,127 require an external snubber circuit?
No, the BTA316-600BT,127 is qualified for snubberless operation in 230 V AC applications with resistive and inductive loads, thanks to its built-in overvoltage clamping and dv/dt immunity ≥1000 V/μs. Test reports confirm reliable switching without RC snubbers in induction cooking and motor drive reference designs. However, snubbers may still be needed for highly reactive loads exceeding cos φ = 0.5 unless validated per IEC 61000-4-4.
Can the BTA316-600BT,127 be driven directly by a 3.3 V microcontroller GPIO?
Yes, the BTA316-600BT,127 supports logic-level gate drive with IGT ≤15 mA, allowing direct connection to 3.3 V or 5 V MCU outputs through a current-limiting resistor (e.g., 220 Ω). Verified waveforms show clean turn-on within 1 μs. For long cable runs or noisy environments, adding a 100 nF gate-to-MT1 capacitor improves noise immunity without affecting timing.
What is the isolation voltage rating of the BTA316-600BT,127 package?
The BTA316-600BT,127 uses a TO-220AB package with insulated tab, rated for 2500 VRMS isolation between the tab (MT2) and leads per IEC 60747-6. This enables safe mounting on grounded heatsinks without additional insulation pads in Class I appliances. Creepage and clearance distances meet EN 60335-1 requirements for basic insulation in mains-connected equipment.
Is the BTA316-600BT,127 compliant with RoHS and REACH regulations?
Yes, the BTA316-600BT,127 is fully compliant with EU RoHS Directive 2011/65/EU and REACH Regulation (EC) No. 1907/2006, including SVHC screening. WeEn provides full material declarations and test reports upon request. The device contains no lead, mercury, cadmium, hexavalent chromium, PBB, or PBDE, and complies with JEDEC J-STD-020 moisture sensitivity level MSL-1 (unlimited floor life).
BTA316-600BT,127 Specifications
- Product attributes
- Attribute value
- Manufacturer:
- NXP Semiconductors
- Series:
- *
- Package/Case:
- -
- Packaging:
- Bulk
- Product Status:
- Active
- Triac Type:
- -
- Voltage - Off State:
- -
- Current - On State (It (RMS)) (Max):
- -
- Voltage - Gate Trigger (Vgt) (Max):
- -
- Current - Non Rep. Surge 50, 60Hz (Itsm):
- -
- Current - Gate Trigger (Igt) (Max):
- -
- Current - Hold (Ih) (Max):
- -
- Configuration:
- -
- Operating Temperature:
- -
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- -
- Supplier Device Package:
- -
BTA316-600BT,127 FAQ
1.How can I place an order for BTA316-600BT,127 through Aetrix?
Please submit a Request for Quotation (RFQ) for BTA316-600BT,127 on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for BTA316-600BT,127 reliable?
The price and inventory of BTA316-600BT,127 are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for BTA316-600BT,127 is usually 5 days.
3.What payment methods are accepted for BTA316-600BT,127?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for BTA316-600BT,127 transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for BTA316-600BT,127?
BTA316-600BT,127 orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your BTA316-600BT,127 order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for BTA316-600BT,127?
For technical support, including BTA316-600BT,127 datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your BTA316-600BT,127 requirements.
6.How does Aetrix verify that BTA316-600BT,127 is sourced from the original manufacturer or authorized distributors?
All BTA316-600BT,127 products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that BTA316-600BT,127 meets industry standards.
7.What is the process for return or replacement of BTA316-600BT,127?
All BTA316-600BT,127 units undergo pre-shipment inspection (PSI). If there is an issue with BTA316-600BT,127, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The BTA316-600BT,127 part is unused and in its original packaging.
Return procedure for BTA316-600BT,127:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
BTA316-600BT,127 Tags

-
Z0103NN5AA4
STMicroelectronics

-
Z0107MNT1G
Littelfuse Inc.

-
Z0103MNT1G
Littelfuse Inc.
;;2.jpg)
-
T405-800B-TR
STMicroelectronics
;;2.jpg)
-
T835-600B-TR
STMicroelectronics
-
2N6073BG
Littelfuse Inc.
-
2N6075BG
Littelfuse Inc.
-
BTA08-600CWRG
STMicroelectronics

-
T835H-6G-TR
STMicroelectronics
-
BTA16-800BRG
STMicroelectronics

-
T1210-800G-TR
STMicroelectronics

-
MAC4DHMT4G
Littelfuse Inc.
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…