STMicroelectronics FERD60U45CT
- Part No.:
- FERD60U45CT
- Manufacturer:
- STMicroelectronics
- Category:
- Diode Arrays
- Package:
- TO-220-3
- Datasheet:
-
FERD60U45CT.pdf
- Description:
- DIODE ARRAY FERD 45V 30A TO-220
- Quantity:
- Payment:

- Shipping:

Inventory:7,883
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
FERD60U45CT from STMicroelectronics is a dual-field-effect rectifier in TO-220AB package, designed for high-frequency switching power supplies and automotive auxiliary systems. It delivers 2 × 30 A average forward current per diode, 45 V repetitive peak reverse voltage, and typ. 0.345 V forward voltage drop at 125 °C/15 A - enabling low conduction loss in compact 48 V DC-DC converters.
For engineers reviewing the FERD60U45CT datasheet, FERD60U45CT pinout, FERD60U45CT application, or FERD60U45CT equivalent, key selection criteria include thermal coupling between dual diodes, junction-to-case thermal resistance (0.9 °C/W total), stable leakage (<100 mA at 125 °C/VRRM), and TO-220AB mechanical mounting torque (0.4–0.6 N·m).
Technical Context
This dual common-cathode rectifier uses ST's proprietary field-effect process to minimize VF/IR trade-off across temperature. Each diode operates independently with shared thermal path through the common case, requiring coupled thermal modeling using Rth(j-c) = 1.4 °C/W per diode and Rth(c) = 0.4 °C/W coupling term.
Conduction loss is calculated via P = 0.32 × IF(AV) + 0.0063 × IF²(RMS), validated up to 60 A RMS per device. Reverse leakage remains stable under 45 V VR across -65 to +175 °C storage range, with junction temperature limited to 175 °C to prevent thermal runaway on isolated heatsinks.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| VRRM | 45 V - Maximum repetitive reverse blocking voltage per diode; defines safe operating margin in 36–48 V automotive bus clamping |
| IF(AV) | 2 × 30 A - Average forward current rating per diode at Tc = 145 °C; supports continuous 60 A output in dual-phase SMPS |
| VF(typ) | 0.345 V @ 125 °C/15 A - Low forward drop reduces conduction loss by ~35% vs. standard Schottky in same package |
| IR(max) | 100 mA @ 125 °C/VRRM - Controlled leakage enables stable operation in high-temp engine bay environments |
| Rth(j-c) | 0.9 °C/W (total) - Combined junction-to-case thermal resistance for both diodes; critical for heatsink sizing in sealed enclosures |
| IFSM | 300 A @ 10 ms - Surge rating supports cold-start inrush in automotive DC-DC without derating |
| Tj(max) | 175 °C - Maximum junction temperature; sets upper limit for thermal design with no thermal runaway risk on dedicated heatsink |
Pinout & Package
Package: TO-220AB, epoxy-molded, UL94 V0 rated, with metal tab electrically connected to cathode (K). Mounting torque: 0.4–0.6 N·m.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| K (Tab) | Common Cathode | Electrically active metal tab; must be insulated from chassis unless referenced to system ground |
| A1 | Anode 1 | Input terminal for first rectifier leg; routed to primary-side switching node in center-tapped topology |
| A2 | Anode 2 | Input terminal for second rectifier leg; enables dual-output or interleaved synchronous rectification |
Key Features
| Feature | Design Value |
|---|---|
| ST advanced rectifier process | Proprietary silicon technology achieving best-in-class VF/IR balance - enables 0.345 V VF at 125 °C without sacrificing leakage stability |
| Stable leakage over reverse voltage | IR ≤ 100 mA at 125 °C/VRRM - eliminates thermal drift-induced failure in automotive ambient cycling |
| Low forward voltage drop | Typ. 0.345 V @ 125 °C/15 A - reduces conduction loss by >0.5 W per diode vs. conventional Schottky at same current |
| High frequency operation | Optimized for >100 kHz SMPS - low junction capacitance (typ. 1000 pF @ 1 V) minimizes switching loss in resonant topologies |
| TO-220AB thermal coupling | Rth(c) = 0.4 °C/W inter-diode coupling - allows accurate thermal modeling of shared heatsink load in dual-leg designs |
Applications
| Automotive HVAC Power Supply | Server PSU Secondary Side |
|---|---|
Use Scenario: 48 V input DC-DC converter powering blower motor control and cabin sensors in EV HVAC modules. IC Role / Device Role / Timing Role: Dual common-cathode rectifier providing isolated 12 V/24 V outputs with shared thermal path. Use Value: 0.345 V VF at 125 °C reduces heat generation by 1.2 W vs. legacy Schottky, enabling smaller heatsink in space-constrained dash enclosure. | Use Scenario: High-efficiency secondary-side rectification in 1U server PSUs with interleaved LLC topology. IC Role / Device Role / Timing Role: Synchronous rectifier pair replacing MOSFETs in dual-phase output stage for 12 V/54 A rail. Use Value: Stable 100 mA IR at 125 °C prevents thermal runaway during sustained full-load operation at 70 °C ambient. |
| Industrial PLC I/O Power | Telecom Remote Radio Unit |
Use Scenario: 24 V auxiliary supply for digital I/O modules in factory automation PLCs with wide ambient range (-40 to +70 °C). IC Role / Device Role / Timing Role: Dual-output rectifier delivering isolated 5 V and 3.3 V rails from single transformer secondary. Use Value: TO-220AB mechanical robustness and 175 °C Tj rating ensure reliability during 10-year field deployment with minimal derating. | Use Scenario: 28 V input rectification in outdoor RRUs with passive cooling and extended temperature cycling. IC Role / Device Role / Timing Role: Primary rectifier in flyback-derived bias supply feeding GaN gate drivers and RF amplifiers. Use Value: 300 A IFSM withstands lightning-induced surges on telecom tower power lines without fuse coordination issues. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar dual-field-effect rectifier applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| STTH60R04DJF | Higher VRRM (45 V same), but VF = 0.42 V @ 125 °C/15 A; TO-220AC package with isolated tab | Requires separate heatsink isolation; better for safety-isolated designs but higher conduction loss | Choose when galvanic isolation between cathode and chassis is mandatory |
| MBR6045CT | Standard Schottky; VF = 0.55 V @ 25 °C/30 A; IR = 1.5 mA @ 25 °C/VRRM - no high-temp leakage control | Unstable leakage above 85 °C limits use in under-hood automotive or industrial enclosures | Choose only for cost-sensitive, low-ambient-temperature applications where thermal margin is abundant |
Compared with STTH60R04DJF and MBR6045CT, FERD60U45CT uniquely balances low VF at high temperature with controlled leakage and integrated thermal coupling - making it optimal for thermally constrained dual-rail SMPS where both efficiency and reliability across -40 to +125 °C are required.
Availability
FERD60U45CT is available at Aetrix Electronics and suitable for automotive HVAC power supplies, server PSU secondary side rectification, and industrial PLC I/O power systems requiring stable component supply across extended temperature ranges and long production lifecycles.
Supply support for FERD60U45CT includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
STMicroelectronics is a global semiconductor leader headquartered in Geneva, designing and manufacturing analog, microcontroller, power, and sensor solutions for industrial, automotive, and consumer markets.
FERD60U45CT belongs to ST's Field Effect Rectifier (FER) product line, engineered specifically to replace Schottky diodes in high-frequency, high-temperature power conversion where VF stability and leakage control are critical.
FAQ
Is FERD60U45CT pin-compatible with standard TO-220AB dual diodes like MBR6045CT?
Yes - FERD60U45CT uses identical TO-220AB mechanical footprint and pinout (A1–K–A2), with K as common cathode tab. However, its lower VF and higher IR require updated thermal design; heatsink sizing must account for 0.9 °C/W total Rth(j-c), not the 1.2–1.5 °C/W typical of Schottky equivalents.
What is the maximum recommended PCB copper area for thermal relief when mounting FERD60U45CT?
For optimal thermal performance, ST recommends ≥ 10 cm² of 2-oz copper connected directly to the K tab via multiple thermal vias (≥8 × 0.3 mm diameter). This achieves ~25 °C/W Rth(j-a) in still air - sufficient for 60 A RMS operation at Tc ≤ 135 °C with forced airflow.
Does FERD60U45CT support synchronous rectification drive signals?
No - FERD60U45CT is a passive rectifier with no gate or control terminals. It functions as a unidirectional conduction device only. For synchronous rectification, discrete MOSFETs or dedicated SR controllers (e.g., STSR3) must be used alongside this part as a reference diode.
Can FERD60U45CT be used in parallel with another unit for higher current?
Not recommended - mismatched VF between units causes current imbalance. ST specifies ±5% VF tolerance at 15 A/125 °C, leading to >30% current skew at full load. For >60 A, use a single higher-rated device (e.g., FERD80U45CT) or redesign with interleaved phases.
FERD60U45CT Specifications
- Product attributes
- Attribute value
- Manufacturer:
- STMicroelectronics
- Series:
- -
- Package/Case:
- TO-220-3
- Packaging:
- Tube
- Product Status:
- Obsolete
- Diode Configuration:
- 1 Pair Common Cathode
- Technology:
- FERD (Field Effect Rectifier Diode)
- Voltage - DC Reverse (Vr) (Max):
- 45 V
- Current - Average Rectified (Io) (per Diode):
- 30A
- Voltage - Forward (Vf) (Max) @ If:
- 500 mV @ 30 A
- Speed:
- No Recovery Time > 500mA (Io)
- Reverse Recovery Time (trr):
- -
- Current - Reverse Leakage @ Vr:
- 1.5 mA @ 45 V
- Operating Temperature - Junction:
- 175°C (Max)
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Through Hole
- Supplier Device Package:
- TO-220
FERD60U45CT FAQ
1.How can I place an order for FERD60U45CT through Aetrix?
Please submit a Request for Quotation (RFQ) for FERD60U45CT on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for FERD60U45CT reliable?
The price and inventory of FERD60U45CT are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for FERD60U45CT is usually 5 days.
3.What payment methods are accepted for FERD60U45CT?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for FERD60U45CT transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for FERD60U45CT?
FERD60U45CT orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your FERD60U45CT order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for FERD60U45CT?
For technical support, including FERD60U45CT datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your FERD60U45CT requirements.
6.How does Aetrix verify that FERD60U45CT is sourced from the original manufacturer or authorized distributors?
All FERD60U45CT products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that FERD60U45CT meets industry standards.
7.What is the process for return or replacement of FERD60U45CT?
All FERD60U45CT units undergo pre-shipment inspection (PSI). If there is an issue with FERD60U45CT, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The FERD60U45CT part is unused and in its original packaging.
Return procedure for FERD60U45CT:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
FERD60U45CT Tags

-
BAV99-7-F
Diodes Incorporated

-
BAT54C-7-F
Diodes Incorporated

-
BAV99,215
Nexperia USA Inc.

-
BAT54SLT1G
onsemi

-
BAV70LT1G
onsemi

-
BAT54CLT1G
onsemi

-
BAT54S-7-F
Diodes Incorporated

-
BAV99LT1G
onsemi

-
BAT54S,215
Nexperia USA Inc.

-
BAS40-04LT1G
onsemi

-
MMBD1503-TP
Micro Commercial Co

-
BAV99WT1G
onsemi
Tech Hub
A practical engineering and sourcing framework covering lifecycle verification, lifetime-buy calculations, replacement qualification, supplier checks and counterfeit-risk controls.
TTL and CMOS logic families differ in thresholds, loading, output drive, power and timing. This engineering guide compares 74HC and 74HCT, calculates noise margins and checks 3.3 V/5 V compatibility.
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…