Send an Inquiry

To receive a quote for your project, please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Part Number*
Quantity*
Message
Submit Inventory List

Please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Upload My List
Message

Infineon Technologies KP212F1701XTMA1

Part No.:
KP212F1701XTMA1
Manufacturer:
Infineon Technologies
Category:
Pressure Sensors, Transducers
Package:
8-SMD Module
Datasheet:
AetrixKP212F1701XTMA1.pdf
Description:
SENSOR 16.68PSIA 4.5V DSOF8
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:2,239

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

KP212F1701 from Infineon Technologies is an analog absolute pressure sensor IC based on capacitive surface micromachining and monolithic BiCMOS signal conditioning. It delivers ratiometric voltage output (0.4 V to 4.65 V) across 10–115 kPa, with ±1.4 kPa accuracy at 0–85 °C, -40 °C to 125 °C operating temperature, and integrated broken-wire detection for automotive manifold air pressure measurement.

For engineers reviewing the KP212F1701 datasheet, KP212F1701 pinout, KP212F1701 application, or KP212F1701 equivalent, this page provides verified functional context, calibrated transfer behavior, PG-DSOF-8-16 package mapping, E²PROM-based linearization parameters, and OBD-compatible clamping thresholds - all critical for engine control unit (ECU) integration and ISO 26262-compliant diagnostics.

Technical Context

The KP212F1701 implements a third-order polynomial digital linearization algorithm using factory-stored E²PROM coefficients (90+22 bit), enabling precise conversion of capacitive pressure sensing into a ratiometric analog output. Its internal clock generator (30 kHz) drives ADC (10-bit) and DAC (12-bit) stages, while temperature compensation and offset/gain correction are applied in real time.

Clamping circuitry enforces defined overvoltage/undervoltage thresholds (VDD and GND referenced), enabling robust open-bond detection without external components. The dual-GND pin layout (Pins 6 & 8) and floating TEST/CLOCK/DATA pins support automotive-grade grounding integrity and ESD-safe calibration handling.

Key Specifications

Parameter Value and Actual Design Meaning
Pressure Range 10 kPa to 115 kPa absolute - calibrated linear span for intake manifold vacuum and boost monitoring in ICE engines.
Output Voltage 0.4 V to 4.65 V ratiometric - scales directly with VDD (5 V typical), eliminating need for separate reference voltage in ECU analog front-end.
Accuracy ±1.4 kPa (0–85 °C), ±2.1 kPa (-40 °C and 125 °C) - meets ASIL-B diagnostic requirements for closed-loop air-fuel ratio control.
Operating Temp -40 °C to +125 °C - qualified per AEC-Q100 Grade 1, enabling under-hood deployment without derating.
Ratiometric Error ±0.5 % of VDD,Typ - ensures stable output scaling across supply variation in vehicle battery systems (4.5–5.5 V).
Supply Voltage 4.5 V to 5.5 V - compatible with standard automotive 5 V LDO rails and immune to transient load dump effects.
Package PG-DSOF-8-16 - "green" RoHS-compliant SMD housing with exposed thermal pad, optimized for reflow soldering and thermal stability.

Pinout & Package

Package: PG-DSOF-8-16 - 8-pin surface-mount device with dual ground terminals (Pins 6 & 8), exposed thermal pad, and lead-free "green" finish compliant with JEDEC MS-012 standards.

Pin/Terminal Circuit Role Design Meaning
1 (TEST) Digital test interface Used only during factory calibration; must remain floating in application to prevent cross-grounding via ESD diodes.
2 (CLOCK / VPROG) Serial programming clock / programming voltage input Enables post-assembly EEPROM write; inactive during normal operation - tied to VDD or left open.
3 (DATA IN) Serial data input Accepts calibration data during programming; high-impedance and unused in analog output mode.
4 (DATA OUT) Serial data output Reads stored E²PROM coefficients; not used when operating in default analog output mode.
5 (VDD) Power supply input Primary 4.5–5.5 V supply rail; powers analog signal chain, digital logic, and internal reference.
6 & 8 (GND) Circuit ground return Both pins must be connected to minimize ground loop impedance and ensure accurate ratiometric output referencing.
7 (VOUT) Analog pressure output Ratiometric voltage output (0.4–4.65 V); designed for direct connection to 12-bit ADC inputs in ECUs.

Key Features

Feature Design Value
Capacitive MEMS sensing element Surface-micromachined silicon diaphragm with integrated BiCMOS signal conditioning - enables high long-term stability and low hysteresis (<0.15 kPa).
Factory-calibrated E²PROM 90+22 bit storage for offset, gain, temperature coefficients, and third-order linearization coefficients - eliminates field calibration effort.
Broken wire detection (OBD) Clamping-driven open-circuit diagnosis - detects VDD/GND interruption by forcing VOUT to rail voltages, enabling fail-safe ECU response.
Ratiometric output architecture VOUT = VDD × (a × P + b), where a = 0.00810 1/kPa and b = −0.00095 - removes dependency on external voltage references in noisy automotive environments.
AEC-Q100 Grade 1 qualification Validated for −40 °C to +125 °C operation with lifetime reliability >15 years - suitable for powertrain and chassis control modules.

Applications

Engine Intake Manifold Monitoring Industrial Vacuum Control Systems

Use Scenario: Real-time measurement of absolute intake manifold pressure in gasoline and diesel engines for air mass calculation and torque estimation.

IC Role / Device Role / Timing Role: Primary analog pressure transducer feeding ECU ADC; output updated at ≥1 kHz sampling rate with <10 µs propagation delay.

Use Value: Enables closed-loop stoichiometric combustion control with ±1.4 kPa accuracy, reducing NOx emissions and improving fuel economy.

Use Scenario: Monitoring vacuum level in semiconductor process chambers and HVAC refrigerant recovery units.

IC Role / Device Role / Timing Role: Absolute pressure feedback sensor interfacing with industrial PLC analog inputs; operates continuously across wide ambient temperature swings.

Use Value: Delivers stable ratiometric output unaffected by supply ripple, eliminating need for isolated signal conditioners in factory automation I/O modules.

Medical Respiratory Equipment Two-Wheeler Engine Management

Use Scenario: Pressure sensing in portable ventilators and anesthesia machines for breath-by-breath tidal volume and PEEP control.

IC Role / Device Role / Timing Role: Safety-critical analog sensor with clamping-based fault detection - supports ISO 80601-2-12 compliance for medical device alarms.

Use Value: Integrated OBD and EEPROM-stored calibration ensure traceable accuracy over device lifetime, reducing recalibration frequency in field-deployed equipment.

Use Scenario: Manifold pressure acquisition in 125–500 cc motorcycle ECUs where space and thermal constraints limit sensor selection.

IC Role / Device Role / Timing Role: Compact SMD pressure sensor mounted directly on ECU PCB; PG-DSOF-8-16 footprint minimizes board area vs. through-hole alternatives.

Use Value: "Green" packaging and AEC-Q100 qualification enable single-source procurement for global two-wheeler OEMs without requalification overhead.

Equivalent & Alternatives

The following parts are listed as comparable options for similar absolute pressure sensing applications.

Alternative Part Technical Difference Application Difference Selection Advice
Bosch BMP388 Digital I²C/SPI output; 0.08 Pa RMS noise; no ratiometric analog output; requires external ADC and firmware integration. Targets IoT and consumer wearables; lacks automotive qualification and OBD features. Select if digital interface, ultra-low noise, and software-defined calibration are prioritized over plug-and-play analog integration.
TE Connectivity MS5837-02BA 24-bit digital output; waterproof stainless steel housing; 0.2 mbar resolution; requires external voltage regulator and level-shifting. Designed for underwater depth sensing; not AEC-Q100 qualified; no clamping or broken-wire detection. Select for submersible or high-resolution barometric applications where automotive diagnostics are irrelevant.

Compared with BMP388 and MS5837-02BA, the KP212F1701 uniquely combines AEC-Q100 qualification, ratiometric analog output, integrated OBD, and factory-trimmed E²PROM - making it the only drop-in solution for production automotive ECU designs requiring zero firmware modification and ISO 26262-aligned diagnostics.

Availability

KP212F1701 is available at Aetrix Electronics and suitable for engine control units, industrial vacuum controllers, medical respiratory devices, and two-wheeler powertrain systems requiring stable component supply, long-lifecycle support, and automotive-grade reliability.

Supply support for KP212F1701 includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

Infineon Technologies is a German semiconductor manufacturer specializing in power management, automotive microcontrollers, and intelligent sensors - with leadership in AEC-Q100-qualified analog and MEMS devices.

The KP212F1701 belongs to Infineon's KP family of analog pressure sensors, engineered specifically for high-accuracy, safety-critical automotive intake air measurement - balancing precision, diagnostics, and system-level integration simplicity.

FAQ

What is the maximum allowable supply voltage for KP212F1701?

The absolute maximum supply voltage is 6.0 V, but continuous operation must remain within 4.5 V to 5.5 V per datasheet Section 2.2. Exceeding 5.5 V risks permanent damage to the internal BiCMOS signal chain and E²PROM memory cells - no overvoltage protection is integrated beyond clamping on VOUT.

Does KP212F1701 require external calibration after soldering?

No. All calibration coefficients - including offset, gain, temperature coefficients, and third-order linearization parameters - are factory-programmed into on-chip E²PROM and applied automatically during operation. No external calibration or trimming is needed, even after reflow soldering or thermal cycling.

How does broken wire detection work without external circuitry?

Internal JFET-based clamping pulls VOUT to VDD if GND is disconnected, or to GND if VDD fails. The ECU monitors VOUT against programmable thresholds (e.g., <0.3 V or >4.8 V) to detect open-circuit faults - eliminating need for external comparators or watchdog circuits in ASIL-B designs.

Can KP212F1701 be used for differential pressure measurement?

No. The KP212F1701 is an absolute pressure sensor with a sealed reference cavity. It measures pressure relative to vacuum, not between two ports. For differential applications, Infineon's KP210 or KP220 series - which feature dual-port MEMS structures - must be selected instead.

KP212F1701XTMA1 Specifications

Product attributes
Attribute value
Manufacturer:
Infineon Technologies
Series:
-
Package/Case:
8-SMD Module
Packaging:
Tape & Reel (TR)
Product Status:
Active
Applications:
-
Pressure Type:
Absolute
Operating Pressure:
2.18PSI ~ 16.68PSI (15kPa ~ 115kPa)
Output Type:
Analog Voltage
Output:
0.5 V ~ 4.5 V
Accuracy:
±0.29PSI (±2kPa)
Voltage - Supply:
4.5V ~ 5.5V
Port Size:
-
Port Style:
No Port
Features:
Amplified Output, Temperature Compensated
Termination Style:
SMD (SMT) Tab
Maximum Pressure:
21.76PSI (150kPa)
Operating Temperature:
-40°C ~ 125°C (TA)
Grade:
Automotive
Qualification:
AEC-Q100
Mounting Type:
Surface Mount
Supplier Device Package:
PG-DSOF-8-16

KP212F1701XTMA1 FAQ

1.How can I place an order for KP212F1701XTMA1 through Aetrix?

Please submit a Request for Quotation (RFQ) for KP212F1701XTMA1 on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for KP212F1701XTMA1 reliable?

The price and inventory of KP212F1701XTMA1 are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for KP212F1701XTMA1 is usually 5 days.

3.What payment methods are accepted for KP212F1701XTMA1?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for KP212F1701XTMA1 transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for KP212F1701XTMA1?

KP212F1701XTMA1 orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your KP212F1701XTMA1 order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for KP212F1701XTMA1?

For technical support, including KP212F1701XTMA1 datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your KP212F1701XTMA1 requirements.

6.How does Aetrix verify that KP212F1701XTMA1 is sourced from the original manufacturer or authorized distributors?

All KP212F1701XTMA1 products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that KP212F1701XTMA1 meets industry standards.

7.What is the process for return or replacement of KP212F1701XTMA1?

All KP212F1701XTMA1 units undergo pre-shipment inspection (PSI). If there is an issue with KP212F1701XTMA1, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The KP212F1701XTMA1 part is unused and in its original packaging.

Return procedure for KP212F1701XTMA1:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

KP212F1701XTMA1 Tags

  • KP212F1701XTMA1
  • KP212F1701XTMA1 PDF
  • KP212F1701XTMA1 Datasheet
  • KP212F1701XTMA1 Specifications
  • KP212F1701XTMA1 Images
  • Infineon Technologies
  • Infineon Technologies KP212F1701XTMA1
  • Buy KP212F1701XTMA1
  • KP212F1701XTMA1 Price
  • KP212F1701XTMA1 Distributor
  • KP212F1701XTMA1 Supplier
  • KP212F1701XTMA1 Wholesale
Related Products
DPS368XTSA1
DPS368XTSA1

Infineon Technologies

DPS310XTSA1
DPS310XTSA1

Infineon Technologies

LPS22HHTR
LPS22HHTR

STMicroelectronics

ICP-20100
ICP-20100

TDK InvenSense

ICP-10110
ICP-10110

TDK InvenSense

LPS22DFTR
LPS22DFTR

STMicroelectronics

LPS22HBTR
LPS22HBTR

STMicroelectronics

BMP390
BMP390

Bosch Sensortec

BMP581
BMP581

Bosch Sensortec

BMP384
BMP384

Bosch Sensortec

2511020213301
2511020213301

Würth Elektronik

ILPS22QSTR
ILPS22QSTR

STMicroelectronics

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER