Overview
KP212F1701 from Infineon Technologies is an analog absolute pressure sensor IC based on capacitive surface micromachining and monolithic BiCMOS signal conditioning. It delivers ratiometric voltage output (0.4 V to 4.65 V) across 10–115 kPa, with ±1.4 kPa accuracy at 0–85 °C, -40 °C to 125 °C operating temperature, and integrated broken-wire detection for automotive manifold air pressure measurement.
For engineers reviewing the KP212F1701 datasheet, KP212F1701 pinout, KP212F1701 application, or KP212F1701 equivalent, this page provides verified functional context, calibrated transfer behavior, PG-DSOF-8-16 package mapping, E²PROM-based linearization parameters, and OBD-compatible clamping thresholds - all critical for engine control unit (ECU) integration and ISO 26262-compliant diagnostics.
Technical Context
The KP212F1701 implements a third-order polynomial digital linearization algorithm using factory-stored E²PROM coefficients (90+22 bit), enabling precise conversion of capacitive pressure sensing into a ratiometric analog output. Its internal clock generator (30 kHz) drives ADC (10-bit) and DAC (12-bit) stages, while temperature compensation and offset/gain correction are applied in real time.
Clamping circuitry enforces defined overvoltage/undervoltage thresholds (VDD and GND referenced), enabling robust open-bond detection without external components. The dual-GND pin layout (Pins 6 & 8) and floating TEST/CLOCK/DATA pins support automotive-grade grounding integrity and ESD-safe calibration handling.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Pressure Range | 10 kPa to 115 kPa absolute - calibrated linear span for intake manifold vacuum and boost monitoring in ICE engines. |
| Output Voltage | 0.4 V to 4.65 V ratiometric - scales directly with VDD (5 V typical), eliminating need for separate reference voltage in ECU analog front-end. |
| Accuracy | ±1.4 kPa (0–85 °C), ±2.1 kPa (-40 °C and 125 °C) - meets ASIL-B diagnostic requirements for closed-loop air-fuel ratio control. |
| Operating Temp | -40 °C to +125 °C - qualified per AEC-Q100 Grade 1, enabling under-hood deployment without derating. |
| Ratiometric Error | ±0.5 % of VDD,Typ - ensures stable output scaling across supply variation in vehicle battery systems (4.5–5.5 V). |
| Supply Voltage | 4.5 V to 5.5 V - compatible with standard automotive 5 V LDO rails and immune to transient load dump effects. |
| Package | PG-DSOF-8-16 - "green" RoHS-compliant SMD housing with exposed thermal pad, optimized for reflow soldering and thermal stability. |
Pinout & Package
Package: PG-DSOF-8-16 - 8-pin surface-mount device with dual ground terminals (Pins 6 & 8), exposed thermal pad, and lead-free "green" finish compliant with JEDEC MS-012 standards.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 (TEST) | Digital test interface | Used only during factory calibration; must remain floating in application to prevent cross-grounding via ESD diodes. |
| 2 (CLOCK / VPROG) | Serial programming clock / programming voltage input | Enables post-assembly EEPROM write; inactive during normal operation - tied to VDD or left open. |
| 3 (DATA IN) | Serial data input | Accepts calibration data during programming; high-impedance and unused in analog output mode. |
| 4 (DATA OUT) | Serial data output | Reads stored E²PROM coefficients; not used when operating in default analog output mode. |
| 5 (VDD) | Power supply input | Primary 4.5–5.5 V supply rail; powers analog signal chain, digital logic, and internal reference. |
| 6 & 8 (GND) | Circuit ground return | Both pins must be connected to minimize ground loop impedance and ensure accurate ratiometric output referencing. |
| 7 (VOUT) | Analog pressure output | Ratiometric voltage output (0.4–4.65 V); designed for direct connection to 12-bit ADC inputs in ECUs. |
Key Features
| Feature | Design Value |
|---|---|
| Capacitive MEMS sensing element | Surface-micromachined silicon diaphragm with integrated BiCMOS signal conditioning - enables high long-term stability and low hysteresis (<0.15 kPa). |
| Factory-calibrated E²PROM | 90+22 bit storage for offset, gain, temperature coefficients, and third-order linearization coefficients - eliminates field calibration effort. |
| Broken wire detection (OBD) | Clamping-driven open-circuit diagnosis - detects VDD/GND interruption by forcing VOUT to rail voltages, enabling fail-safe ECU response. |
| Ratiometric output architecture | VOUT = VDD × (a × P + b), where a = 0.00810 1/kPa and b = −0.00095 - removes dependency on external voltage references in noisy automotive environments. |
| AEC-Q100 Grade 1 qualification | Validated for −40 °C to +125 °C operation with lifetime reliability >15 years - suitable for powertrain and chassis control modules. |
Applications
| Engine Intake Manifold Monitoring | Industrial Vacuum Control Systems |
|---|---|
|
Use Scenario: Real-time measurement of absolute intake manifold pressure in gasoline and diesel engines for air mass calculation and torque estimation. IC Role / Device Role / Timing Role: Primary analog pressure transducer feeding ECU ADC; output updated at ≥1 kHz sampling rate with <10 µs propagation delay. Use Value: Enables closed-loop stoichiometric combustion control with ±1.4 kPa accuracy, reducing NOx emissions and improving fuel economy. |
Use Scenario: Monitoring vacuum level in semiconductor process chambers and HVAC refrigerant recovery units. IC Role / Device Role / Timing Role: Absolute pressure feedback sensor interfacing with industrial PLC analog inputs; operates continuously across wide ambient temperature swings. Use Value: Delivers stable ratiometric output unaffected by supply ripple, eliminating need for isolated signal conditioners in factory automation I/O modules. |
| Medical Respiratory Equipment | Two-Wheeler Engine Management |
|
Use Scenario: Pressure sensing in portable ventilators and anesthesia machines for breath-by-breath tidal volume and PEEP control. IC Role / Device Role / Timing Role: Safety-critical analog sensor with clamping-based fault detection - supports ISO 80601-2-12 compliance for medical device alarms. Use Value: Integrated OBD and EEPROM-stored calibration ensure traceable accuracy over device lifetime, reducing recalibration frequency in field-deployed equipment. |
Use Scenario: Manifold pressure acquisition in 125–500 cc motorcycle ECUs where space and thermal constraints limit sensor selection. IC Role / Device Role / Timing Role: Compact SMD pressure sensor mounted directly on ECU PCB; PG-DSOF-8-16 footprint minimizes board area vs. through-hole alternatives. Use Value: "Green" packaging and AEC-Q100 qualification enable single-source procurement for global two-wheeler OEMs without requalification overhead. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar absolute pressure sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| Bosch BMP388 | Digital I²C/SPI output; 0.08 Pa RMS noise; no ratiometric analog output; requires external ADC and firmware integration. | Targets IoT and consumer wearables; lacks automotive qualification and OBD features. | Select if digital interface, ultra-low noise, and software-defined calibration are prioritized over plug-and-play analog integration. |
| TE Connectivity MS5837-02BA | 24-bit digital output; waterproof stainless steel housing; 0.2 mbar resolution; requires external voltage regulator and level-shifting. | Designed for underwater depth sensing; not AEC-Q100 qualified; no clamping or broken-wire detection. | Select for submersible or high-resolution barometric applications where automotive diagnostics are irrelevant. |
Compared with BMP388 and MS5837-02BA, the KP212F1701 uniquely combines AEC-Q100 qualification, ratiometric analog output, integrated OBD, and factory-trimmed E²PROM - making it the only drop-in solution for production automotive ECU designs requiring zero firmware modification and ISO 26262-aligned diagnostics.
Availability
KP212F1701 is available at Aetrix Electronics and suitable for engine control units, industrial vacuum controllers, medical respiratory devices, and two-wheeler powertrain systems requiring stable component supply, long-lifecycle support, and automotive-grade reliability.
Supply support for KP212F1701 includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Infineon Technologies is a German semiconductor manufacturer specializing in power management, automotive microcontrollers, and intelligent sensors - with leadership in AEC-Q100-qualified analog and MEMS devices.
The KP212F1701 belongs to Infineon's KP family of analog pressure sensors, engineered specifically for high-accuracy, safety-critical automotive intake air measurement - balancing precision, diagnostics, and system-level integration simplicity.
FAQ
What is the maximum allowable supply voltage for KP212F1701?
The absolute maximum supply voltage is 6.0 V, but continuous operation must remain within 4.5 V to 5.5 V per datasheet Section 2.2. Exceeding 5.5 V risks permanent damage to the internal BiCMOS signal chain and E²PROM memory cells - no overvoltage protection is integrated beyond clamping on VOUT.
Does KP212F1701 require external calibration after soldering?
No. All calibration coefficients - including offset, gain, temperature coefficients, and third-order linearization parameters - are factory-programmed into on-chip E²PROM and applied automatically during operation. No external calibration or trimming is needed, even after reflow soldering or thermal cycling.
How does broken wire detection work without external circuitry?
Internal JFET-based clamping pulls VOUT to VDD if GND is disconnected, or to GND if VDD fails. The ECU monitors VOUT against programmable thresholds (e.g., <0.3 V or >4.8 V) to detect open-circuit faults - eliminating need for external comparators or watchdog circuits in ASIL-B designs.
Can KP212F1701 be used for differential pressure measurement?
No. The KP212F1701 is an absolute pressure sensor with a sealed reference cavity. It measures pressure relative to vacuum, not between two ports. For differential applications, Infineon's KP210 or KP220 series - which feature dual-port MEMS structures - must be selected instead.
KP212F1701XTMA1 Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Infineon Technologies
- Series:
- -
- Package/Case:
- 8-SMD Module
- Packaging:
- Tape & Reel (TR)
- Product Status:
- Active
- Applications:
- -
- Pressure Type:
- Absolute
- Operating Pressure:
- 2.18PSI ~ 16.68PSI (15kPa ~ 115kPa)
- Output Type:
- Analog Voltage
- Output:
- 0.5 V ~ 4.5 V
- Accuracy:
- ±0.29PSI (±2kPa)
- Voltage - Supply:
- 4.5V ~ 5.5V
- Port Size:
- -
- Port Style:
- No Port
- Features:
- Amplified Output, Temperature Compensated
- Termination Style:
- SMD (SMT) Tab
- Maximum Pressure:
- 21.76PSI (150kPa)
- Operating Temperature:
- -40°C ~ 125°C (TA)
- Grade:
- Automotive
- Qualification:
- AEC-Q100
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- PG-DSOF-8-16
KP212F1701XTMA1 FAQ
1.How can I place an order for KP212F1701XTMA1 through Aetrix?
Please submit a Request for Quotation (RFQ) for KP212F1701XTMA1 on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for KP212F1701XTMA1 reliable?
The price and inventory of KP212F1701XTMA1 are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for KP212F1701XTMA1 is usually 5 days.
3.What payment methods are accepted for KP212F1701XTMA1?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for KP212F1701XTMA1 transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for KP212F1701XTMA1?
KP212F1701XTMA1 orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your KP212F1701XTMA1 order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for KP212F1701XTMA1?
For technical support, including KP212F1701XTMA1 datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your KP212F1701XTMA1 requirements.
6.How does Aetrix verify that KP212F1701XTMA1 is sourced from the original manufacturer or authorized distributors?
All KP212F1701XTMA1 products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that KP212F1701XTMA1 meets industry standards.
7.What is the process for return or replacement of KP212F1701XTMA1?
All KP212F1701XTMA1 units undergo pre-shipment inspection (PSI). If there is an issue with KP212F1701XTMA1, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The KP212F1701XTMA1 part is unused and in its original packaging.
Return procedure for KP212F1701XTMA1:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
KP212F1701XTMA1 Tags

-
DPS368XTSA1
Infineon Technologies

-
DPS310XTSA1
Infineon Technologies

-
LPS22HHTR
STMicroelectronics

-
ICP-20100
TDK InvenSense

-
ICP-10110
TDK InvenSense

-
LPS22DFTR
STMicroelectronics

-
LPS22HBTR
STMicroelectronics

-
BMP390
Bosch Sensortec

-
BMP581
Bosch Sensortec

-
BMP384
Bosch Sensortec

-
2511020213301
Würth Elektronik

-
ILPS22QSTR
STMicroelectronics
Tech Hub
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…
LDO regulator guide covering low dropout voltage, power dissipation, thermal design, PSRR, output noise, capacitor stability, adjustable LDO circuits, LDO vs buck converter and datasheet selection chec…
Conditional Access Module guide covering CAM meaning, CI/CI+ interface, smart card authorization, DVB security workflow, TV and set-top box compatibility, internal electronics, ESD protection, connecto…
Guide to electronic component obsolescence covering EOL risk, PCN/PDN notices, last-time buy planning, replacement options, form-fit-function validation, counterfeit risk and BOM lifecycle management.
18650 battery guide covering lithium-ion cell basics, 3.6V/3.7V voltage, 4.2V charging, mAh and Wh capacity, protected cells, chargers, BMS, series-parallel packs, holders, welding and sourcing checks.…
Hall effect sensor guide covering working principle, linear and digital sensors, Arduino circuits, current sensing, speed detection, automotive applications, A3144 examples, signal filtering and datash…
Product Change Notification guide for electronic components, covering PCN meaning, PCN vs PDN/EOL, common change types, risk levels, form-fit-function review, engineering validation, BOM control, LTB/L…
A practical guide to blend door actuators, covering HVAC function, symptoms, location, AC and heater issues, reset and calibration, replacement cost, electrical diagnosis, compatibility checks, and rep…
Engineering guide to Raspberry Pi alternatives, covering chip-level differences, Orange Pi, ROCK, Jetson, Banana Pi, NanoPi, Compute Module, Pico, GPIO, camera, HAT compatibility, and replacement risks…