Infineon Technologies KP276D1201XTMA1
- Part No.:
- KP276D1201XTMA1
- Manufacturer:
- Infineon Technologies
- Category:
- Pressure Sensors, Transducers
- Package:
- 8-SMD Module
- Datasheet:
-
KP276D1201XTMA1.pdf
- Description:
- SENSOR 58.02PSIA 12BIT DSOF8
- Quantity:
- Payment:

- Shipping:

Inventory:2,713
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
KP276D1201 from Infineon is a digital absolute pressure sensor IC based on capacitive sensing, featuring SENT (SAE J2716 rev. 2016) output, integrated NTC temperature interface, ±0.77% FSS pressure accuracy, real 12-bit pressure and temperature resolution, and AEC-Q100 qualification for automotive manifold air pressure (MAP) measurement.
For engineers reviewing the KP276D1201 datasheet, KP276D1201 pinout, KP276D1201 application, or KP276D1201 equivalent, this device delivers calibrated digital pressure/temperature data over SENT with built-in diagnostics, media-robust SMD packaging, and support for external NTC linearization - critical for engine control unit (ECU) integration and functional safety validation.
Technical Context
The KP276D1201 implements a monolithic BiCMOS signal conditioning circuit with dual-channel digitization: one path for internal capacitive pressure sensing (linear transfer function, clamped 1–4088 LSB), and another for external NTC voltage conditioning (12-bit digitized, calibrated via ST = 8.0 LSB/°C and offsT = 585.2 LSB). Both channels feed into a digital core supporting normal and diagnostic modes triggered at power-on.
Its SENT interface operates in enhanced serial message format with synchronization pulse, status nibble, and fast-channel transmission of full 12-bit pressure and temperature codes per frame. SPI pins (NCS/CLK/SDI/SDO) are reserved for calibration only and must be left floating in application circuits.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Pressure Range | 10–400 kPa absolute; supports full MAP range for gasoline/diesel intake manifolds. |
| Pressure Accuracy | ±0.77% FSS over −40°C to +150°C; enables high-fidelity air mass calculation in ECU models. |
| Output Resolution | Real 12-bit for both pressure and temperature; delivers 4088 distinct pressure codes (1–4088 LSB). |
| SENT Protocol | SAE J2716 rev. April 2016 compliant; supports fast-channel dual-data frames and slow-channel diagnostic nibbles. |
| NTC Interface | Dedicated NTCIN pin with internal buffer amplifier and linearization; accepts standard automotive NTCs (e.g., 10 kΩ @ 25°C). |
| Operating Temp | −40°C to +170°C ambient; qualified per AEC-Q100 Grade 0; enables under-hood deployment. |
| Supply Voltage | 4.5–5.5 V; integrated voltage regulator ensures stable analog/digital domain operation. |
Pinout & Package
Package: PG-DSOF-8-162 - green, media-robust, surface-mount housing with 8-pin SOIC footprint and exposed thermal pad (not electrically connected).
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 NCS | Not-Chip-Select (active-low) | Enables SPI communication during calibration only; must be left floating in production use. |
| 2 CLK | Serial Clock | External clock input for SPI interface; unused in SENT operational mode. |
| 3 SDI | Serial Data In | Calibration data input pin; no functional role during SENT operation. |
| 4 SDO | Serial Data Out | Tri-state SPI output; inactive when NCS is high or during normal SENT operation. |
| 5 VDD | Supply Voltage | Primary 4.5–5.5 V power rail; powers internal regulator, ADC, and SENT driver. |
| 6 SENTOUT | SENT Output | Single-wire digital output carrying synchronized pressure/temperature frames per SAE J2716. |
| 7 NTCIN | NTC Input | Analog input for external NTC sensor; includes internal bias current and buffer amplifier. |
| 8 GND | Ground | Analog/digital common reference; requires low-impedance connection to minimize noise coupling. |
Key Features
| Feature | Design Value |
|---|---|
| Integrated Diagnostic Mode | Power-on self-test verifies sensor cell integrity and signal path continuity without host intervention. |
| Media-Robust Housing | PG-DSOF-8-162 package qualified for direct exposure to aggressive automotive fluids and vibration. |
| Two-Channel Digital Output | Simultaneous 12-bit pressure and 12-bit temperature values transmitted per SENT frame for time-aligned acquisition. |
| External NTC Linearization | On-chip compensation using stored ST/offsT coefficients eliminates need for host-side lookup tables. |
| AEC-Q100 Qualified | Grade 0 (−40°C to +170°C) qualification confirms reliability for safety-critical engine management systems. |
Applications
| Engine Intake Manifold Pressure Monitoring | Boost Pressure Control in Turbocharged Systems |
|---|---|
|
Use Scenario: Real-time measurement of absolute pressure in gasoline/diesel engine intake manifolds for air mass calculation and fuel injection timing. IC Role / Device Role / Timing Role: Primary absolute pressure transducer feeding ECU with SENT-synchronized 12-bit pressure data at up to 100 Hz frame rate. Use Value: ±0.77% FSS accuracy and clamped 10–400 kPa range directly support stoichiometric combustion control across cold start to wide-open throttle conditions. |
Use Scenario: Closed-loop regulation of turbocharger wastegate or variable geometry vanes using boost pressure feedback. IC Role / Device Role / Timing Role: High-stability pressure sensor providing SENT output with <16 µs signal path latency for fast-acting boost control loops. Use Value: Dual-channel 12-bit resolution enables simultaneous pressure and intake air temperature correction, improving transient boost response accuracy by >15% vs. single-sensor solutions. |
| Industrial Vacuum System Monitoring | Medical Respiratory Equipment Sensing |
|
Use Scenario: Continuous monitoring of vacuum levels in semiconductor process tools or HVAC refrigerant recovery systems. IC Role / Device Role / Timing Role: Absolute pressure interface with diagnostic capability for predictive maintenance alerts and fault logging. Use Value: Built-in self-diagnosis (Diag1/Diag2/EEPROM check) reduces need for external watchdog circuitry and supports IEC 61508 SIL2 system compliance. |
Use Scenario: Precise airway pressure measurement in portable ventilators and anesthesia machines requiring traceable calibration. IC Role / Device Role / Timing Role: AEC-Q100-qualified sensor delivering calibrated SENT output for FDA Class II medical device BOMs. Use Value: Green SMD packaging and −40°C to +170°C operating range enable sterilizable, compact designs meeting ISO 13485 manufacturing requirements. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar absolute pressure sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MPX5700A | Analog ratiometric output (0.2–4.8 V), no SENT or NTC interface; ±2% FSS accuracy; no AEC-Q100 qualification. | Lacks digital protocol support and integrated diagnostics; requires external ADC and temperature compensation. | Select when cost-sensitive non-automotive industrial designs prioritize analog simplicity over functional safety features. |
| BMP580 | I²C/SPI digital interface, ±0.12 hPa pressure accuracy, but no SENT output, no NTC interface, and not AEC-Q100 qualified. | Targeted at consumer IoT; lacks automotive-grade robustness, media resistance, and SENT compatibility for ECU integration. | Choose for battery-powered portable devices where ultra-low power and high-resolution barometric sensing outweigh protocol and qualification needs. |
Compared with MPX5700A and BMP580, the KP276D1201 uniquely combines SENT protocol compliance, AEC-Q100 Grade 0 qualification, integrated NTC interface, and on-chip diagnostics - making it the only drop-in solution for ASIL-B–capable engine control modules requiring validated digital pressure/temperature fusion.
Availability
KP276D1201 is available at Aetrix Electronics and suitable for engine control units, turbocharger boost systems, and medical respiratory equipment requiring stable component supply, long-term lifecycle assurance, and automotive-grade traceability.
Supply support for KP276D1201 includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Infineon Technologies is a German semiconductor manufacturer specializing in power management, sensor, and automotive ICs, with global R&D and manufacturing infrastructure.
The KP276D1201 belongs to Infineon's dTurboTMAP sensor family, engineered specifically for high-accuracy, safety-compliant manifold and boost pressure measurement in modern ICE and hybrid powertrains.
FAQ
What is the SENT configuration string for KP276D1201?
The device uses SENT2016-03.0us-6dn-ppc(282.0)-esp-A.5: nominal 3.0 µs clock tick, 6 data nibbles, primary pressure code (PPC) with 282.0 kPa reference, enhanced serial protocol (ESP), and A.5 checksum variant. This matches SAE J2716 April 2016 revision for deterministic ECU decoding.
Can the KP276D1201 operate without an external NTC?
Yes - the NTCIN pin may be left unconnected or tied to GND; the device will still output valid 12-bit pressure data via SENTOUT. Temperature reporting will be disabled, but pressure accuracy and diagnostics remain fully functional per AEC-Q100 test plan.
How is pressure clamping implemented in the KP276D1201?
Internal clamping limits pressure output to 1 LSB (10 kPa) at low end and 4088 LSB (400 kPa) at high end. This prevents erroneous readings outside the calibrated range and provides explicit out-of-range indication to the host ECU via fixed-code boundaries.
Are the SPI pins required for normal operation?
No - NCS, CLK, SDI, and SDO are exclusively for factory calibration and test. Infineon recommends leaving them floating in end applications; they have no effect on SENT output, diagnostics, or NTC functionality during powered operation.
KP276D1201XTMA1 Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Infineon Technologies
- Series:
- -
- Package/Case:
- 8-SMD Module
- Packaging:
- Tape & Reel (TR)
- Product Status:
- Active
- Applications:
- -
- Pressure Type:
- Absolute
- Operating Pressure:
- 1.45 ~ 58.02PSI (10kPa ~ 400kPa)
- Output Type:
- SENT
- Output:
- 12 b
- Accuracy:
- ±0.77%
- Voltage - Supply:
- 4.5V ~ 5.5V
- Port Size:
- -
- Port Style:
- No Port
- Features:
- Temperature Compensated
- Termination Style:
- SMD (SMT) Tab
- Maximum Pressure:
- -
- Operating Temperature:
- -40°C ~ 150°C
- Grade:
- Automotive
- Qualification:
- AEC-Q100
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- PG-DSOF-8-162
KP276D1201XTMA1 FAQ
1.How can I place an order for KP276D1201XTMA1 through Aetrix?
Please submit a Request for Quotation (RFQ) for KP276D1201XTMA1 on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for KP276D1201XTMA1 reliable?
The price and inventory of KP276D1201XTMA1 are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for KP276D1201XTMA1 is usually 5 days.
3.What payment methods are accepted for KP276D1201XTMA1?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for KP276D1201XTMA1 transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for KP276D1201XTMA1?
KP276D1201XTMA1 orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your KP276D1201XTMA1 order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for KP276D1201XTMA1?
For technical support, including KP276D1201XTMA1 datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your KP276D1201XTMA1 requirements.
6.How does Aetrix verify that KP276D1201XTMA1 is sourced from the original manufacturer or authorized distributors?
All KP276D1201XTMA1 products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that KP276D1201XTMA1 meets industry standards.
7.What is the process for return or replacement of KP276D1201XTMA1?
All KP276D1201XTMA1 units undergo pre-shipment inspection (PSI). If there is an issue with KP276D1201XTMA1, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The KP276D1201XTMA1 part is unused and in its original packaging.
Return procedure for KP276D1201XTMA1:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
KP276D1201XTMA1 Tags

-
DPS368XTSA1
Infineon Technologies

-
DPS310XTSA1
Infineon Technologies

-
LPS22HHTR
STMicroelectronics

-
ICP-20100
TDK InvenSense

-
ICP-10110
TDK InvenSense

-
LPS22DFTR
STMicroelectronics

-
LPS22HBTR
STMicroelectronics

-
BMP390
Bosch Sensortec

-
BMP581
Bosch Sensortec

-
BMP384
Bosch Sensortec

-
2511020213301
Würth Elektronik

-
ILPS22QSTR
STMicroelectronics
Tech Hub
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…
LDO regulator guide covering low dropout voltage, power dissipation, thermal design, PSRR, output noise, capacitor stability, adjustable LDO circuits, LDO vs buck converter and datasheet selection chec…
Conditional Access Module guide covering CAM meaning, CI/CI+ interface, smart card authorization, DVB security workflow, TV and set-top box compatibility, internal electronics, ESD protection, connecto…
Guide to electronic component obsolescence covering EOL risk, PCN/PDN notices, last-time buy planning, replacement options, form-fit-function validation, counterfeit risk and BOM lifecycle management.
18650 battery guide covering lithium-ion cell basics, 3.6V/3.7V voltage, 4.2V charging, mAh and Wh capacity, protected cells, chargers, BMS, series-parallel packs, holders, welding and sourcing checks.…
Hall effect sensor guide covering working principle, linear and digital sensors, Arduino circuits, current sensing, speed detection, automotive applications, A3144 examples, signal filtering and datash…
Product Change Notification guide for electronic components, covering PCN meaning, PCN vs PDN/EOL, common change types, risk levels, form-fit-function review, engineering validation, BOM control, LTB/L…
A practical guide to blend door actuators, covering HVAC function, symptoms, location, AC and heater issues, reset and calibration, replacement cost, electrical diagnosis, compatibility checks, and rep…