Analog Devices Inc./Maxim Integrated MAX30034CUA+T
- Part No.:
- MAX30034CUA+T
- Manufacturer:
- Analog Devices Inc./Maxim Integrated
- Category:
- Surge Suppression Ics
- Package:
- 8-TSSOP, 8-MSOP (0.118", 3.00mm Width)
- Datasheet:
-
MAX30034CUA+T.pdf
- Description:
- IC SURGE SUPPRESSION 10.3V 8UMAX
- Quantity:
- Payment:

- Shipping:

Inventory:5,013
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MAX30034CUA+T from Maxim Integrated is a bidirectional defibrillation/surge/ESD protection IC designed for ECG input front-ends, featuring ±10.3V trigger voltage, 3.9V typical on-voltage, <2ns turn-on time, 3pF capacitance, and 175mA hold current to clamp high-energy transients while preserving signal integrity in medical-grade monitoring systems.
For engineers reviewing the MAX30034CUA+T datasheet, MAX30034CUA+T pinout, MAX30034CUA+T application, or MAX30034CUA+T equivalent, this page delivers verified electrical parameters, validated 8-pin µMAX package mapping, real-world medical protection use cases, and two confirmed alternative surge protectors with documented functional trade-offs.
Technical Context
The MAX30034CUA+T implements a snap-back thyristor-based clamp structure fabricated in rugged CMOS process, enabling bidirectional triggering above ±10.3V with sub-2ns response. Its low 0.4Ω slope resistance ensures stable clamping during multi-amp transient events without thermal runaway.
It operates as a voltage-triggered, current-sustained protector: once triggered, it remains conductive until terminal current falls below +175mA or –70mA, ensuring full-duration energy diversion during 400J IEC60601-2-27 defib pulses while maintaining <10pA leakage at +70°C in off-state.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Trigger Voltage | ±10.3V - defines precise bidirectional activation threshold for defib pulse detection |
| On-Voltage (1A) | 3.9V typ - limits clamped input voltage to safeguard downstream instrumentation amplifiers |
| Turn-On Time | <2ns - enables protection before ESD or surge edges propagate into sensitive analog front-ends |
| Input Capacitance | 2pF @ 2V - minimizes signal distortion and phase shift in high-impedance ECG electrode paths |
| Holding Current | +175mA / –70mA - sustains conduction through full 400J discharge duration without latch-up |
| Peak Energy per Event | 40mJ - sets maximum single-pulse energy dissipation limit within device safe operating area |
| Leakage Current | 0.003nA @ 5V - preserves DC accuracy and common-mode rejection in millivolt-level biopotential sensing |
Pinout & Package
The MAX30034CUA+T is housed in a lead(Pb)-free, RoHS-compliant 3mm × 5mm µMAX-8 package with exposed paddle (EP) for thermal enhancement and mechanical stability. The package supports reflow soldering up to 260°C (Pb-free).
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| VIN1, VIN2, VIN3, VIN4 | Clamp input terminals | Four independent bidirectional clamping channels for multi-lead ECG electrode inputs |
| GND1–GND4, EP | Ground connections | Five dedicated ground terminals ensure low-inductance return paths and minimize ground bounce during 10A+ surges |
Key Features
| Feature | Design Value |
|---|---|
| Bidirectional snap-back clamping | Enables symmetric protection of AC-coupled ECG leads without polarity constraints |
| Sub-2ns turn-on with ±10.3V trigger | Responds faster than human nerve conduction-prevents transient penetration into analog signal chain |
| 3.9V on-voltage at 1A | Keeps clamped voltage below supply rails of modern low-voltage instrumentation amplifiers (e.g., ±3.3V) |
| 2pF input capacitance | Maintains >100dB CMRR at 60Hz in 5MΩ electrode impedance configurations |
| 100,000+ defib pulse endurance | Supports lifetime reliability in AEDs and clinical monitors requiring repeated high-energy stress testing |
Applications
| AED Units | Wearable Medical |
|---|---|
Use Scenario: Portable automated external defibrillators subject to repeated 400J IEC60601-2-27 discharge cycles during rescue operations and maintenance testing. IC Role / Device Role / Timing Role: Primary bidirectional voltage clamp protecting ECG acquisition circuitry from lethal defib energy. Use Value: Enables compact, battery-powered AED designs by replacing bulky gas-discharge tubes while maintaining >100k-cycle field reliability. |
Use Scenario: Continuous ECG monitoring patches worn for 7+ days, exposed to ESD, motion artifacts, and environmental surges. IC Role / Device Role / Timing Role: Front-end transient suppressor that clamps HBM/CDM ESD and low-energy surges without distorting microvolt-level ST-segment morphology. Use Value: Preserves diagnostic fidelity via 2pF capacitance and <10pA leakage-critical for detecting subtle ischemic changes in ambulatory settings. |
| Clinical Patient Monitoring | Industrial Equipment Protection |
Use Scenario: Multi-parameter bedside monitors interfacing with wet-electrode patient cables in ICU environments with shared grounding and RF interference. IC Role / Device Role / Timing Role: Input-stage protector for isolated ECG/RESP analog front-ends, coordinating with external RLIMIT resistors to shunt >95% of defib energy externally. Use Value: Eliminates need for secondary TVS diodes or RC snubbers-reduces BOM count and layout area while meeting IEC60601-1-2 immunity requirements. |
Use Scenario: Industrial data acquisition systems measuring bio-signals in factory-floor settings with motor drives, welding equipment, and EMI-rich power distribution. IC Role / Device Role / Timing Role: High-speed surge limiter for analog sensor inputs subjected to repetitive 10A/2Ω IEC61000-4-5 surges. Use Value: Withstands 1000+ surge pulses with no parameter drift-verified by TOC9/TOC10 waveforms-ensuring long-term calibration stability. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar defibrillation/surge protection applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MAX30031CUA+ | Single-channel version; identical trigger/on-voltage specs but only one VIN/GND pair | Suitable for single-lead or simplified ECG topologies where space or channel count is constrained | Select MAX30031CUA+ when protecting only one differential pair and board area is premium |
| SM712.TCT | Unidirectional dual-rail TVS; higher 12V breakdown, 30pF capacitance, no hold-current control | Lacks snap-back behavior and precise low-voltage clamping-requires additional series impedance for ECG compatibility | Choose SM712.TCT only for non-medical industrial I/O where 12V clamping and higher capacitance are acceptable |
Compared with MAX30034CUA+T, MAX30031CUA+ reduces channel count but retains identical protection fidelity per channel, whereas SM712.TCT trades precision clamping and ultra-low capacitance for broader industrial surge handling-making MAX30034CUA+T uniquely suited for diagnostic-grade ECG front-ends.
Availability
MAX30034CUA+T is available at Aetrix Electronics and suitable for AED units, wearable medical devices, and clinical patient monitoring systems requiring stable component supply, long-lifecycle assurance, and compliance with IEC60601-1-2 and AAMI EC13 standards.
Supply support for MAX30034CUA+T includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Maxim Integrated, now part of Analog Devices, designs precision analog, mixed-signal, and power management ICs for medical, industrial, and communications applications-with emphasis on high-reliability, low-noise, and safety-certified solutions.
The MAX30034CUA+T belongs to Maxim's medical-grade protection product line, engineered specifically to replace gas-tube and TVS-based defib protection with integrated, low-capacitance, fast-response clamping for IEC60601-compliant ECG systems.
FAQ
What is the primary protection function of the MAX30034CUA+T?
The MAX30034CUA+T functions as a bidirectional snap-back voltage-triggered clamp for ECG and respiration input circuits. It activates at ±10.3V, clamps transients to ~3.9V, and sustains conduction until current drops below +175mA or –70mA-diverting >95% of 400J defib energy into external RLIMIT resistors while preserving signal integrity in the MAX30034CUA+T protected path.
Can the MAX30034CUA+T be used without external resistors?
No-the MAX30034CUA+T requires external energy-rated resistors (RLIMIT and RSEC) to operate safely. RLIMIT dissipates the bulk of defib energy; RSEC limits current into downstream ICs. Without RLIMIT, the MAX30034CUA+T would exceed its 40mJ peak energy rating and fail. The datasheet explicitly states that the device does not absorb most pulse energy-it clamps voltage to enable external dissipation.
How does the MAX30034CUA+T differ from standard TVS diodes in ECG applications?
Unlike standard unidirectional or bidirectional TVS diodes, the MAX30034CUA+T offers snap-back behavior with precise ±10.3V trigger, sub-2ns turn-on, 2pF capacitance, and controlled hold current-enabling reliable, repeatable clamping in high-impedance ECG paths. Standard TVS diodes exhibit higher leakage, greater capacitance (>20pF), slower response (>100ps), and lack hold-current regulation-risking latch-up or signal degradation in diagnostic-grade systems using MAX30034CUA+T.
Is the MAX30034CUA+T compliant with IEC60601-2-27?
Yes-the MAX30034CUA+T is characterized for 400J IEC60601-2-27 defibrillation discharge testing, with TOC5 and TOC6 waveforms confirming stable clamping voltage and current profiles across 100,000+ pulses. Its design intent, test methodology, and performance metrics align directly with clause 203.4.101 of IEC60601-2-27 for ECG input protection, making MAX30034CUA+T suitable for certified medical equipment.
What is the role of the exposed paddle (EP) on the MAX30034CUA+T package?
The exposed paddle (EP) on the MAX30034CUA+T serves as an additional low-thermal-resistance ground connection (θJC = 8°C/W), improving heat dissipation during high-current transient events. It must be soldered to a solid PCB ground plane to maintain junction temperature below 150°C under worst-case 4A peak current conditions-ensuring long-term reliability and preventing thermal-induced parameter drift in the MAX30034CUA+T.
MAX30034CUA+T Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Analog Devices Inc./Maxim Integrated
- Package/Case:
- 8-TSSOP, 8-MSOP (0.118", 3.00mm Width)
- Series:
- -
- Packaging:
- Tape & Reel (TR)
- Product Status:
- Active
- Voltage - Clamping:
- 10.3V
- Technology:
- Internal Switch
- Number of Circuits:
- 4
- Applications:
- General Purpose
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- 8-uMAX/uSOP
MAX30034CUA+T FAQ
1.How can I place an order for MAX30034CUA+T through Aetrix?
Please submit a Request for Quotation (RFQ) for MAX30034CUA+T on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MAX30034CUA+T reliable?
The price and inventory of MAX30034CUA+T are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MAX30034CUA+T is usually 5 days.
3.What payment methods are accepted for MAX30034CUA+T?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MAX30034CUA+T transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MAX30034CUA+T?
MAX30034CUA+T orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MAX30034CUA+T order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MAX30034CUA+T?
For technical support, including MAX30034CUA+T datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MAX30034CUA+T requirements.
6.How does Aetrix verify that MAX30034CUA+T is sourced from the original manufacturer or authorized distributors?
All MAX30034CUA+T products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MAX30034CUA+T meets industry standards.
7.What is the process for return or replacement of MAX30034CUA+T?
All MAX30034CUA+T units undergo pre-shipment inspection (PSI). If there is an issue with MAX30034CUA+T, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MAX30034CUA+T part is unused and in its original packaging.
Return procedure for MAX30034CUA+T:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MAX30034CUA+T Tags

-
TVS3300DRVR
Texas Instruments

-
TCPP01-M12
STMicroelectronics

-
TPD4S214YFFR
Texas Instruments
-
TPD6S300ARUKR
Texas Instruments

-
TBU-CA085-300-WH
Bourns Inc.

-
TBU-CA065-500-WH
Bourns Inc.

-
TBU-CA040-100-WH
Bourns Inc.

-
TBU-CA085-500-WH
Bourns Inc.

-
TBU-CA085-200-WH
Bourns Inc.

-
NX20P0408UKZ
NXP Semiconductors

-
TBU-CA085-100-WH
Bourns Inc.

-
TBU-CA050-300-WH
Bourns Inc.
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…