Diodes Incorporated MBR10200CTF-G1
- Part No.:
- MBR10200CTF-G1
- Manufacturer:
- Diodes Incorporated
- Category:
- Diode Arrays
- Package:
- TO-220-3 Full Pack
- Datasheet:
-
MBR10200CTF-G1.pdf
- Description:
- DIODE ARR SCHOT 200V 5A TO220F3
- Quantity:
- Payment:

- Shipping:

Inventory:50
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MBR10200CTF-G1 from Diodes Incorporated is a high-voltage dual common-cathode Schottky rectifier in TO-220F-3 package, rated for 200 V reverse voltage, 5 A average forward current per diode leg, and 0.95 V max forward voltage at 5 A and +25°C. It delivers low switching losses and low noise in high-frequency SMPS output rectification, power management, and instrumentation.
For engineers reviewing the MBR10200CTF-G1 datasheet, MBR10200CTF-G1 pinout, MBR10200CTF-G1 application, or MBR10200CTF-G1 equivalent, key selection criteria include its dual-diode configuration with common cathode, thermal resistance of 4.5 °C/W (junction-to-case), 100 A non-repetitive surge rating, +150°C junction temperature limit, and RoHS-compliant green packaging.
Technical Context
This dual Schottky rectifier integrates two independent anode terminals (A1, A2) sharing a single cathode (K), enabling synchronous or interleaved rectification topologies. Its guard-ring structure enhances ruggedness against transient stress, while the low VF and ultra-low IR (0.15 mA @ 25°C) reduce conduction loss and leakage-related inefficiency in medium-voltage DC-DC converters.
Designed for high-frequency operation up to 20 kHz square-wave peak current, it supports fast recovery with no minority-carrier storage delay. The TO-220F-3 package provides enhanced thermal performance over standard TO-220-3 via insulated mounting flange, critical for thermally constrained industrial power supplies.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| VRRM | 200 V - Withstands repetitive reverse voltage up to 200 V without breakdown in SMPS secondary-side applications. |
| IF(AV) per leg | 5 A - Supports continuous 5 A DC output current per diode in regulated power supply outputs. |
| VF (max) | 0.95 V @ 5 A, 25°C - Minimizes conduction loss and heat generation at nominal load in high-efficiency designs. |
| IR (max) | 0.15 mA @ 25°C - Limits standby power loss and improves light-load efficiency in always-on systems. |
| TJ(max) | +150°C - Enables reliable operation in enclosed, high-ambient-temperature environments like industrial enclosures. |
| RθJC | 4.5 °C/W - Allows direct heatsink mounting with predictable thermal rise for thermal design margining. |
| IFSM | 100 A - Withstands short-duration inrush and fault currents during startup or overload conditions. |
Pinout & Package
MBR10200CTF-G1 uses the TO-220F-3 (insulated flange) package with three leads: Pin 1 = Anode 1 (A1), Pin 2 = Cathode (K), Pin 3 = Anode 2 (A2). The insulated flange enables direct mounting to heatsinks without electrical isolation hardware.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 (A1) | Anode of first Schottky diode | Connects to transformer secondary or switching node for independent rectification path. |
| 2 (K) | Common cathode | Shared output node for dual-leg configuration; connects to output filter capacitor and load return. |
| 3 (A2) | Anode of second Schottky diode | Enables dual-output or interleaved rectification; electrically isolated from A1. |
Key Features
| Feature | Design Value |
|---|---|
| Low forward voltage | 0.95 V max at 5 A ensures <1.5 W conduction loss per leg at full load, reducing heatsink requirements. |
| Guard-ring protection | Prevents edge breakdown under high dv/dt (10,000 V/µs), improving reliability in fast-switching flyback and LLC converters. |
| +150°C junction rating | Permits operation in sealed enclosures or high-ambient industrial settings without derating below 5 A. |
| Lead-free & halogen-free | RoHS 3 and "Green" compliant (Br+Cl <1500 ppm, Sb <1000 ppm), meeting global environmental compliance mandates. |
Applications
| Server Power Supply Rectification | Industrial DC-DC Converter Output |
|---|---|
Use Scenario: High-density 48 V input / 12 V output server PSU with dual-phase synchronous rectification. IC Role / Device Role / Timing Role: Dual-anode Schottky rectifier providing low-loss secondary-side conduction path with shared cathode return. Use Value: Reduces total conduction loss by ~35% vs. single-diode solutions, enabling higher power density and lower thermal footprint. | Use Scenario: 24 V industrial PLC power module requiring stable 5 V/3.3 V auxiliary rails. IC Role / Device Role / Timing Role: Output rectifier in isolated flyback converter delivering dual regulated outputs. Use Value: Common-cathode topology simplifies PCB layout and reduces component count versus discrete dual-diode implementation. |
| Test Equipment Power Management | Medical Diagnostic Power Stage |
Use Scenario: Bench power supply with programmable 0–30 V / 0–10 A output using linear + switching hybrid regulation. IC Role / Device Role / Timing Role: Main rectifier in high-frequency resonant converter stage feeding bulk capacitor bank. Use Value: Low noise and absence of reverse recovery charge prevent EMI coupling into sensitive analog measurement circuitry. | Use Scenario: Portable ultrasound system with battery-backed 12 V main rail and isolated 5 V sensor interface. IC Role / Device Role / Timing Role: Isolated secondary-side rectifier in compact, fanless AC/DC adapter module. Use Value: TO-220F-3 insulation eliminates need for isolating thermal pads, saving board space and assembly cost. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar dual Schottky rectifier applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| Vishay VS-MBR10200CTPBF | TO-220-3 (non-insulated flange); RθJC = 3.0 °C/W; same VRRM/IF ratings. | Requires insulating washer when mounted to grounded heatsink; better thermal performance in open-frame designs. | Select when mechanical mounting allows direct heatsink contact and thermal priority outweighs isolation needs. |
| ON Semiconductor MBR10200CT | TO-220-3 package; RoHS-compliant but not "Green" (halogen content unspecified); identical electrical specs. | Lacks halogen-free certification; may not meet strict environmental compliance for EU medical exports. | Choose for cost-sensitive industrial applications where full RoHS 3 + Green compliance is not mandated. |
Compared with VS-MBR10200CTPBF and MBR10200CT, MBR10200CTF-G1 uniquely combines insulated flange mounting, verified halogen/antimony-free composition, and guaranteed 4.5 °C/W thermal resistance-making it optimal for compact, safety-certified, and environmentally regulated power modules.
Availability
MBR10200CTF-G1 is available at Aetrix Electronics and suitable for server power supply rectification, industrial DC-DC converter output stages, and test equipment power management requiring stable component supply and long-term lifecycle support.
Supply support for MBR10200CTF-G1 includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Diodes Incorporated is a global manufacturer of discrete semiconductors and analog ICs, specializing in high-performance power management, signal integrity, and protection devices.
MBR10200CTF-G1 belongs to Diodes' high-voltage Schottky rectifier product line, engineered specifically for high-frequency, medium-voltage power conversion where low VF, low IR, and rugged transient handling are essential.
FAQ
What is the maximum case temperature for continuous operation?
The device supports continuous operation up to TC = +140°C, as specified in the Absolute Maximum Ratings table. At this case temperature, the average forward current remains rated at 5 A per diode leg, provided thermal resistance to ambient is maintained within design limits and heatsink mounting meets Diodes' recommended pad layout.
Is MBR10200CTF-G1 suitable for use in automotive applications?
MBR10200CTF-G1 is not AEC-Q101 qualified and lacks automotive-specific qualification testing (e.g., HTOL, temperature cycling). While its +150°C junction rating and robust surge capability align with some under-hood thermal conditions, it is intended for industrial, computing, and instrumentation applications-not automotive safety-critical systems.
How does the TO-220F-3 package differ electrically from TO-220-3?
The TO-220F-3 package features an electrically insulated flange, allowing direct mounting to a grounded heatsink without additional isolation hardware. Electrically, the die and leadframe characteristics are identical to TO-220-3 versions-only thermal resistance (RθJC = 4.5 °C/W vs. 3.0 °C/W) and mounting interface differ.
Can MBR10200CTF-G1 replace a single 10 A Schottky diode?
No-it is a dual 5 A common-cathode device, not a single 10 A diode. Its internal structure contains two independent 5 A Schottky junctions sharing one cathode. Replacing a true 10 A single-diode requires verifying that both anodes are driven identically and that layout accommodates separate input paths.
MBR10200CTF-G1 Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Diodes Incorporated
- Series:
- -
- Package/Case:
- TO-220-3 Full Pack
- Packaging:
- Tube
- Product Status:
- Active
- Diode Configuration:
- 1 Pair Common Cathode
- Technology:
- Schottky
- Voltage - DC Reverse (Vr) (Max):
- 200 V
- Current - Average Rectified (Io) (per Diode):
- 5A
- Voltage - Forward (Vf) (Max) @ If:
- 950 mV @ 5 A
- Speed:
- Fast Recovery =< 500ns, > 200mA (Io)
- Reverse Recovery Time (trr):
- -
- Current - Reverse Leakage @ Vr:
- 150 µA @ 200 V
- Operating Temperature - Junction:
- 150°C (Max)
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Through Hole
- Supplier Device Package:
- TO-220F-3
MBR10200CTF-G1 FAQ
1.How can I place an order for MBR10200CTF-G1 through Aetrix?
Please submit a Request for Quotation (RFQ) for MBR10200CTF-G1 on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MBR10200CTF-G1 reliable?
The price and inventory of MBR10200CTF-G1 are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MBR10200CTF-G1 is usually 5 days.
3.What payment methods are accepted for MBR10200CTF-G1?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MBR10200CTF-G1 transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MBR10200CTF-G1?
MBR10200CTF-G1 orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MBR10200CTF-G1 order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MBR10200CTF-G1?
For technical support, including MBR10200CTF-G1 datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MBR10200CTF-G1 requirements.
6.How does Aetrix verify that MBR10200CTF-G1 is sourced from the original manufacturer or authorized distributors?
All MBR10200CTF-G1 products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MBR10200CTF-G1 meets industry standards.
7.What is the process for return or replacement of MBR10200CTF-G1?
All MBR10200CTF-G1 units undergo pre-shipment inspection (PSI). If there is an issue with MBR10200CTF-G1, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MBR10200CTF-G1 part is unused and in its original packaging.
Return procedure for MBR10200CTF-G1:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MBR10200CTF-G1 Tags

-
BAV99-7-F
Diodes Incorporated

-
BAT54C-7-F
Diodes Incorporated

-
BAV99,215
Nexperia USA Inc.

-
BAT54SLT1G
onsemi

-
BAV70LT1G
onsemi

-
BAT54CLT1G
onsemi

-
BAT54S-7-F
Diodes Incorporated

-
BAV99LT1G
onsemi

-
BAT54S,215
Nexperia USA Inc.

-
BAS40-04LT1G
onsemi

-
MMBD1503-TP
Micro Commercial Co

-
BAV99WT1G
onsemi
Tech Hub
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…
LDO regulator guide covering low dropout voltage, power dissipation, thermal design, PSRR, output noise, capacitor stability, adjustable LDO circuits, LDO vs buck converter and datasheet selection chec…
Conditional Access Module guide covering CAM meaning, CI/CI+ interface, smart card authorization, DVB security workflow, TV and set-top box compatibility, internal electronics, ESD protection, connecto…
Guide to electronic component obsolescence covering EOL risk, PCN/PDN notices, last-time buy planning, replacement options, form-fit-function validation, counterfeit risk and BOM lifecycle management.
18650 battery guide covering lithium-ion cell basics, 3.6V/3.7V voltage, 4.2V charging, mAh and Wh capacity, protected cells, chargers, BMS, series-parallel packs, holders, welding and sourcing checks.…
Hall effect sensor guide covering working principle, linear and digital sensors, Arduino circuits, current sensing, speed detection, automotive applications, A3144 examples, signal filtering and datash…
Product Change Notification guide for electronic components, covering PCN meaning, PCN vs PDN/EOL, common change types, risk levels, form-fit-function review, engineering validation, BOM control, LTB/L…
A practical guide to blend door actuators, covering HVAC function, symptoms, location, AC and heater issues, reset and calibration, replacement cost, electrical diagnosis, compatibility checks, and rep…